2016 Workbook for Architects and Planners Version from: 4 November 2015 Subjecttochangesanderrors. 01 Workbook for Architects and Planners 2016 This handbook is a guide for architects and planners as well as for professionals involved in construction work such as builders and structural carpenters. The handbook explains the strengths of KIELSTEG elements and how they should be used. It is very important to us to make sure you have professional support at all stages of your projects and we want to give you the best possible service in the form of this technical handbook and our consulting. Kielstegis the proud holder of: Schweighofer Preis 2013 Innovationspreis für die europäische Forst-und Holzwirtschaft Inventum2014 The prize of the Austrian Patent Office for the best patent of the year 2013 materialPREIS2015 First prizein thecategory‘woodand woodmaterials’, awardedbythe materialsagencyraumPROBE. 02 Contents 1. General Consulting, supportanddesign..………………….5 Certificates…………………………………………………….6 Product……………………………………………………….. 7 USP‘s….……………………………………………………….. 9 Cost-effectiveness………………………………………..11 Production………………………………………………….. 13 Surface…….…………...……………………………………. 15 2. Designing Planningcriteria………….………………………………. 17 Design steps…….…………………………………………. 19 Sample layoutofa KIELSTEG roof………………. 21 Fasteningprinciples……….……………………………..23 Pad configurations….……………………………….... 25 Cross sections………………………………………………..27 3. Statics Statics…………………………………………………………….37 Productoverview.…………………………………........39 Load diagrams…….……………………………………... 40 Support foropenings…………………………………….4..3... Small penetrations…………………………………………4…5.... Bracing-general principles………………..………….47 Screwfastening…………………………………….........55 4. Building physics Wood………………………………………………………….. 60 Fireprotection……………………………………………….6..1 Thermal insulationU-values……………………………63..... Structuralfloor…………………………………………… 65 Roof….……………………………………………………...... 69 5. Details Suggestedconstructions…………………………….. 75 Kielstegon woodenframeworkwall…………….…83…………... Kielstegon CLT wall…………………………………………87….………. Kielstegon gluelambeam………………………………9…1…….…... Kielstegon masonryorconcretewall……………9…5………….. Kielstegon steelbeam………………………..…………1…0…3……..... 6. Contact Sample box andcontact…………………………….. 107 03 General 04 la r e n e G Foreword KIELSTEGisasystemofflatwoodenstructuralelementsintendedforuseas load-bearingroofsandstructuralfloors.Byplacingthewoodexactlywhere it contributes the most to static performance, KIELSTEG elements can be used economicallyforspans of5m andupwards.Our technologyisnotin competition with established glued wood products such as glulam beams butexpandsthespectrumofpossibilitiesofbuildinginwood. 05 Consulting, support and design KIELSTEGcomesbackedupbyourexpertadviceandservice.Wearecommittedtogiving youallthesupportyouneed.Ourexperiencedexpertsinstructuralengineeringwillhelp youwithallaspectsofstaticsanddesign,buildingphysicsandfireprotection.Wewillhelp you develop building concepts using KIELSTEG and also with the dimensioning of the KIELSTEGelements. o Individual project consulting on the KIELSTEG elements, their applications and dimensioning o Consulting and evaluation in terms of statics, building physics and fire protection o Consulting on other materials to use with KIELSTEG: including structural, sealing and fastening systems o Product-specific support for compiling bills of quantities o Design and construction planning on state-of-the-art CAD-CAM systems o Detailedplanning o Coordination of trades and site supervision 06 la r e n e G Certificates The DIBt (Deutsches Institut für Bautechnik) is the German approval body for construction products and types of construction. The national technical approval (allgemeine bauaufsichtliche Zulassung) regulates the manufacturing and useofKIELSTEGelements. PEFC PEFC,theProgramfortheEndorsementofForestCertification Schemes, is a certification and labelling program for products derived from ecologically, economically and socially sustainable forestry. When customers buy products with the PEFC label, they can be sure that their purchase supports the use of wood produced under environmentally friendly conditions. 07 Product KIELSTEG elements are lightweight and strong KIELSTEG elements are usually used in buildings wooden construction elements without cross- withlargeclearspans,tocreateroofsorstructural lamination,withan internalstructurerunning inone floors.Theabilitytobridgelargespansmaximizes direction. They use strips of timber to form top and the flexibility of how the enclosed space is used. bottomflanges,whichareconnectedbycurvedwebs Thismeetstheimportantarchitecturaldemandto of plywood or OSB. The characteristic curve of the be able to rearrange interior layouts throughout webs, which resembles the keel of a boat, gives the thelifetimeofabuilding. KIELSTEGitsname. Use: Structural floors and roofs Internal structure: Repeating cellular structure with upper and lower flanges of spruce timber connected by webs of plywood or OSBt aus Wood: Spruce Surface: Industrial quality/Visible quality (one side); planed and untreated Dimensions: Width: 1,200 mm Laid width: 1,165 mm Thickness: 228 mm to800 mm Length: 5.00 m to 35.00 m Fireresistanceclass: Fire retarding REI 30 is the standard fire resistance class for all KIELSTEG Highly fire retardant/REI 60 is possible from KSE 280 upwards Long edges: Edges are rebated to overlap/join neighbouring KIELSTEG elements Service class: Service classes 1 and 2 Bonding: MUF glue of emissions class E1 Moisturecontent: On delivery: 12±3% Dimensional changes: (humidity-dependet) Longitudinal: 0.01% per 1% change in wood moisture content Lateral: 0.25% per 1% change in wood moisture content Thickness: insignificant 08 la r e n e G Our Raw Materials KIELSTEGisalightweight,strong wooden composite system which efficiently combines natural timber and processed wood. In this way it involves value creation out of different forms of wood. The system achieves its unique character- isticsbyconcentratingthewood mass exactly where its strength isneeded. Spruce Plywood OSB For the zones of the element Webs of 3-ply, 4 mm spruce and OSB3sheetsofthicknesses 8mm, under compression and tension, pine plywood form the interior 10 mm and 12 mm form the finger-jointed spruce timber of cellular structure of the elements interior cellular structure of the thestrengthclassC24isused. ofthicknesses228mmto380mm. elements of thicknesses 485 mm to800mm. 09 USPs Wide spans for roofs and structural floors Creation of low-profile load-bearing structures spanning spaces up to 27 metres as single-span beam structure and up to 35 metres as continuous beam structure. Cambered single-span elements KIELSTEG elements can be made optionally cambered upwards along their length, with corresponding effects ontheserviceabilitylimitstate. Cantilevered projections Projecting roofs are frequently demanded for industrial and commercial buildings. KIELSTEG can be used to make cantilevered projecting roofs up to ten metres deep.
Description: