Volume IV Appendix U - Appendix Z Oahu Community Correctional Center October 27, 2017 THIS PAGE INTENTIONALLY LEFT BLANK Volume IV Appendices Appendix U: Preliminary Engineering Report Appendix V: Electrical and Telecommunications Utility Systems Appendix W: Airport Surface Evaluation Appendix X: Community Partnering: A Path Forward Appendix Y: Public Engagement and Public Outreach Summary Appendix Z: EISPN Scoping Meeting Summary THIS PAGE INTENTIONALLY LEFT BLANK Appendix U: Preliminary Engineering Report Oahu Community Correctional Center October 27, 2017 Prepared for: State of Hawaii Department of Accounting and General Services Department of Public Safety Prepared by: Oahu Community Correctional Center October 2017 TABLE OF CONTENTS Page 1 Introduction ........................................................................................................................................ 1-1 1.1 Background ............................................................................................................................ 1-1 1.2 Purpose .................................................................................................................................. 1-9 2 Oahu Community Correctional Center ............................................................................................... 2-1 2.1 Roadway, Parking, and Access ............................................................................................. 2-1 2.1.1 Existing Conditions ................................................................................................... 2-1 2.2 Site Grading and Flood Hazard .............................................................................................. 2-3 2.2.1 Existing Conditions ................................................................................................... 2-3 2.2.2 Proposed Improvements .......................................................................................... 2-3 2.3 Storm Drainage System ......................................................................................................... 2-5 2.3.1 Existing Conditions ................................................................................................... 2-5 2.3.2 Project Requirements ............................................................................................... 2-5 2.3.3 Proposed Improvements .......................................................................................... 2-6 2.4 Water Supply System ............................................................................................................. 2-6 2.4.1 Existing Conditions ................................................................................................... 2-6 2.4.2 Connection to the Board of Water Supply System ................................................... 2-6 2.5 Wastewater Collection System .............................................................................................. 2-7 2.5.1 Existing Conditions ................................................................................................... 2-7 2.5.2 Connection to the City Sewer System...................................................................... 2-7 2.5.3 Proposed Improvements .......................................................................................... 2-8 2.6 Natural Gas ............................................................................................................................ 2-8 2.6.1 Existing Conditions ................................................................................................... 2-8 2.6.2 Proposed Improvements .......................................................................................... 2-8 3 Animal Quarantine Station ................................................................................................................. 3-1 3.1 Roadway, Parking, and Access ............................................................................................. 3-1 3.1.1 Existing Conditions ................................................................................................... 3-1 3.1.2 Proposed Improvements .......................................................................................... 3-1 3.2 Site Grading and Flood Hazard .............................................................................................. 3-3 3.2.1 Existing Conditions ................................................................................................... 3-3 3.2.2 Proposed Improvements .......................................................................................... 3-3 3.3 Storm Drainage System ......................................................................................................... 3-5 3.3.1 Existing Conditions ................................................................................................... 3-5 3.3.2 Project Requirements ............................................................................................... 3-5 3.3.3 Proposed Improvements .......................................................................................... 3-6 3.4 Water Supply System ............................................................................................................. 3-6 3.4.1 Existing Conditions ................................................................................................... 3-6 3.4.2 Connection to the Board of Water Supply System ................................................... 3-7 3.4.3 Proposed Improvements .......................................................................................... 3-7 3.5 Wastewater Collection System .............................................................................................. 3-7 3.5.1 Existing Conditions ................................................................................................... 3-7 3.5.2 Connection to the City Sewer System...................................................................... 3-8 3.5.3 Proposed Improvements .......................................................................................... 3-8 3.6 Natural Gas ............................................................................................................................ 3-9 3.6.1 Existing Conditions ................................................................................................... 3-9 3.6.2 Proposed Improvements .......................................................................................... 3-9 4 Halawa Correctional Facility .............................................................................................................. 4-1 4.1 Roadway, Parking, and Access ............................................................................................. 4-1 Proposed OCCC – Preliminary Engineering Report i Oahu Community Correctional Center October 2017 TABLE OF CONTENTS (continued) Page 4.1.1 Existing Conditions ................................................................................................... 4-1 4.1.2 Proposed Improvements .......................................................................................... 4-1 4.2 Site Grading and Flood Hazard .............................................................................................. 4-3 4.2.1 Existing Conditions ................................................................................................... 4-3 4.2.2 Proposed Improvements .......................................................................................... 4-3 4.3 Storm Drainage System ......................................................................................................... 4-5 4.3.1 Existing Conditions ................................................................................................... 4-5 4.3.2 Project Requirements ............................................................................................... 4-5 4.3.3 Proposed Improvements .......................................................................................... 4-6 4.4 Water Supply System ............................................................................................................. 4-6 4.4.1 Existing Conditions ................................................................................................... 4-6 4.4.2 Connection to the Board of Water Supply System ................................................... 4-6 4.4.3 Proposed Improvements .......................................................................................... 4-7 4.5 Wastewater Collection System .............................................................................................. 4-7 4.5.1 Existing Conditions ................................................................................................... 4-7 4.5.2 Connection to the City Sewer System...................................................................... 4-7 4.5.3 Proposed Improvements .......................................................................................... 4-7 4.6 Natural Gas ............................................................................................................................ 4-8 4.6.1 Existing Conditions ................................................................................................... 4-8 4.6.2 Proposed Improvements .......................................................................................... 4-8 5 Mililani Technology Park – Lot 17 ...................................................................................................... 5-1 5.1 Roadway, Parking, and Access ............................................................................................. 5-1 5.1.1 Existing Conditions ................................................................................................... 5-1 5.1.2 Proposed Improvements .......................................................................................... 5-1 5.2 Site Grading and Flood Hazard .............................................................................................. 5-3 5.2.1 Existing Conditions ................................................................................................... 5-3 5.2.2 Proposed Improvements .......................................................................................... 5-3 5.3 Storm Drainage System ......................................................................................................... 5-5 5.3.1 Existing Conditions ................................................................................................... 5-5 5.3.2 Project Requirements ............................................................................................... 5-5 5.3.3 Proposed Improvements .......................................................................................... 5-5 5.4 Water Supply System ............................................................................................................. 5-6 5.4.1 Existing Conditions ................................................................................................... 5-6 5.4.2 Connection to the Board of Water Supply System ................................................... 5-6 5.4.3 Proposed Improvements .......................................................................................... 5-6 5.5 Wastewater Collection System .............................................................................................. 5-7 5.5.1 Existing Conditions ................................................................................................... 5-7 5.5.2 Connection to the City Sewer System...................................................................... 5-7 5.5.3 Proposed Improvements .......................................................................................... 5-7 5.6 Natural Gas ............................................................................................................................ 5-8 5.6.1 Existing Conditions ................................................................................................... 5-8 5.6.2 Proposed Improvements .......................................................................................... 5-8 6 Women’s Community Correctional Center ........................................................................................ 6-1 6.1 Roadway, Parking, and Access ............................................................................................. 6-1 6.1.1 Existing Conditions ................................................................................................... 6-1 6.1.2 Proposed Improvements .......................................................................................... 6-1 6.2 Site Grading and Flood Hazard .............................................................................................. 6-3 6.2.1 Existing Conditions ................................................................................................... 6-3 6.2.2 Proposed Improvements .......................................................................................... 6-3 Proposed OCCC – Preliminary Engineering Report ii Oahu Community Correctional Center October 2017 TABLE OF CONTENTS (continued) Page 6.3 Storm Drainage System ......................................................................................................... 6-5 6.3.1 Existing Conditions ................................................................................................... 6-5 6.3.2 Project Requirements ............................................................................................... 6-5 6.3.3 Proposed Improvements .......................................................................................... 6-6 6.4 Water Supply System ............................................................................................................. 6-6 6.4.1 Existing Conditions ................................................................................................... 6-6 6.4.2 Connection to the Board of Water Supply System ................................................... 6-7 6.4.3 Proposed Improvements .......................................................................................... 6-7 6.5 Wastewater Collection System .............................................................................................. 6-7 6.5.1 Existing Conditions ................................................................................................... 6-7 6.5.2 Connection to the City Sewer System...................................................................... 6-8 6.5.3 Proposed Improvements .......................................................................................... 6-8 6.6 Natural Gas ............................................................................................................................ 6-8 6.6.1 Existing Conditions ................................................................................................... 6-8 6.6.2 Proposed Improvements .......................................................................................... 6-8 7 References ......................................................................................................................................... 7-1 LIST of FIGURES Page Figure 1-1 Vicinity Map ...................................................................................................................... 1-3 Figure 1-2 OCCC – TMK Map ........................................................................................................... 1-4 Figure 1-3 Animal Quarantine Station – TMK Map ........................................................................... 1-5 Figure 1-4 Halawa Correctional Facility – TMK Map ......................................................................... 1-6 Figure 1-5 Mililani Technology Park Lot 17 – TMK Map ................................................................... 1-7 Figure 1-6 Women’s Community Correctional Center – TMK Map ................................................... 1-8 Figure 2-1 OCCC – Existing Roadway System ................................................................................. 2-2 Figure 2-2 OCCC – Flood Insurance Rate Map ................................................................................ 2-4 Figure 2-3 OCCC – Proposed Improvements ................................................................................... 2-9 Figure 3-1 Animal Quarantine Station – Existing Roadway System ................................................. 3-2 Figure 3-2 Animal Quarantine Station – Flood Insurance Rate Map ................................................ 3-4 Figure 3-3 Animal Quarantine Station – Proposed Improvements .................................................. 3-10 Figure 4-1 Halawa Correctional Facility – Existing Roadway System............................................... 4-2 Figure 4-2 Halawa Correctional Facility – Flood Insurance Rate Map .............................................. 4-4 Figure 4-3 Halawa Correctional Facility – Proposed Improvements ................................................. 4-9 Figure 5-1 Mililani Technology Park Lot 17 – Existing Roadway System ......................................... 5-2 Figure 5-2 Mililani Technology Park Lot 17 – Flood Insurance Rate Map ........................................ 5-4 Figure 5-3 Mililani Technology Park Lot 17 – Proposed Improvements ........................................... 5-9 Figure 6-1 Women’s Community Correctional Center – Existing Roadway System ......................... 6-2 Figure 6-2 Women’s Community Correctional Center – Flood Insurance Rate Map ........................ 6-4 Figure 6-3 Women’s Community Correctional Center – Proposed Improvements ........................... 6-9 Proposed OCCC – Preliminary Engineering Report iii Oahu Community Correctional Center October 2017 APPENDICES Appendix A Oahu Community Correctional Center Appendix B Animal Quarantine Station Appendix C Halawa Correctional Facility Appendix D Mililani Technology Park Lot 17 Appendix E Women’s Community Correctional Center Proposed OCCC – Preliminary Engineering Report iv Oahu Community Correctional Center October 2017 EXECUTIVE SUMMARY The State of Hawaii Department of Public Safety (PSD) is responsible to provide a safe, secure, and humane environment for the care and custody of adult male and female offenders originating from the Island of Oahu. The current Oahu Community Correctional Center (OCCC) is out of date, inefficient and no longer meets the needs of PSD. On behalf of PSD, the State of Hawaii Department of Accounting and General Services (DAGS) is proposing to develop a replacement facility for the existing OCCC facility in Kalihi, Oahu, Hawaii. Four (4) alternative sites on Oahu are under consideration for replacement of the existing OCCC, identified as follows. - Existing OCCC site in Kalihi; - Animal Quarantine Station in Halawa; - Halawa Correctional Facility in Halawa; and - Mililani Technology Park Lot 17 in Mililani Each alternative would include relocating female inmates currently housed at OCCC to the existing Women‘s Community Correctional Center (WCCC) in Kailua. This preliminary engineering assessment was conducted to provide a detailed evaluation of four (4) alternative sites related to the civil infrastructure and utility systems for the replacement of the OCCC. The objective of the report is to review the existing site infrastructure improvements, determine the project requirements related to the roadway and parking facilities, site grading, storm drainage system, sanitary sewer system and water system, and, based on the project requirements, determine required improvements, and identify possible opportunities and constraints for the OCCC replacement facility. An Environmental Impact Statement is being prepared to assess each alternative site and determine which site is most feasible for development of the replacement for the existing OCCC facility. Proposed OCCC – Preliminary Engineering Report v
Description: