Short-circuit, Protective Device Coordination & Arc Flash Analysis PDF

154 Pages·2010·3.8 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Short-circuit, Protective Device Coordination & Arc Flash Analysis

Short-circuit, Protective Device Coordination & Arc Flash Analysis By Albert Marroquin Operation Technology, Inc. Agenda • Short-circuit Calculations for Arc Flash Analysis • Protection and Coordination Principles • Arc Flash Analysis and Mitigation • Upcoming Arc Flash Analysis Standards/Guidelines Changes • DC Arc Flash Analysis • Transient Arc Flash Analysis for Generators Short-Circuit Analysis Types of SC Faults •Three-Phase Ungrounded Fault •Three-Phase Grounded Fault •Phase to Phase Ungrounded Fault •Phase to Phase Grounded Fault •Phase to Ground Fault Fault Current •I can range in utility systems from a few percent to L-G possibly 115 % ( if X < X ) of I (85% of all o 1 3-phase faults). •In industrial systems the situation I > I is rare. L-G 3-phase Typically I ≅ .87 * I L-G 3-phase •In an industrial system, the three-phase fault condition is frequently the only one considered, since this type of fault generally results in Maximum current. Purpose of Short-Circuit Studies • A Short-Circuit Study can be used to determine any or all of the following: (cid:190) Verify protective device close and latch capability (cid:190) Verify protective device Interrupting capability (cid:190) Protect equipment from large mechanical forces (maximum fault kA) (cid:190) I2t protection for equipment (thermal stress) (cid:190) Selecting ratings or settings for relay coordination System Components Involved in SC Calculations • Power Company Supply • In-Plant Generators • Transformers • Reactors • Feeder Cables / Cable Trays and Bus Duct Systems System Components Involved in SC Calculations • Overhead Lines • Synchronous Motors • Induction Motors • Protective Devices • Y from Static Load and Line Cable 0 Short-Circuit Phenomenon i(t) v(t) v(t)=Vm∗Sin(ωt +θ) v(t) i(t) di v(t) = Ri + L = Vm×Sin(ωt + θ) (1) dt Solving equation 1 yields the following expression R Vm Vm e- t i(t) = ×sin(ωt + θ - φ) + ×sin(θ - φ)× L Z Z 144424443 14444244443 Steady State Transient (DC Offset) AC Current (Symmetrical) with No AC Decay DC Current ©1996-2009 Operation Technology, Inc. –Workshop Notes: Short-Circuit ANSI Slide 9 AC Fault Current Including the DC Offset (No AC Decay) ©1996-2009 Operation Technology, Inc. –Workshop Notes: Short-Circuit ANSI Slide 10

Description:
Short-Circuit Analysis Types of SC Faults •Three-Phase Ungrounded Fault •Three-Phase Grounded Fault •Phase to Phase Ungrounded Fault •Phase to Phase Grounded
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.