Quality Control Testing of GE Digital Mammography Systems John M. Sandrik, Ph.D. GE Healthcare Milwaukee, WI [email protected] GE Healthcare 2007 Day 2: Overview General considerations • The QC tests • Tests also done by Rad. Tech. – Flat Field and Phantom Image Quality • MTF and CNR • AOP and SNR • Tests that need no introduction – kVp Accuracy and Reproducibility • Beam Quality Assessment (HVL) • Radiation Output • Mammo. Unit Assembly Evaluation • GE Healthcare 2007 Day 2: Overview (cont’d.) The QC tests • FFDM-specific, FFDM-modified tests – Collimation Assessment / “Film-less” • Evaluation of Focal Spot Performance • Sub-system MTF • Ent. Exposure, Avg. Glandular Dose • Artifact Eval., Flat Field Uniformity • View Conditions Check and Setting • Monitor Calibration • Image Quality–SMPTE Pattern • Display Screen Uniformity • GE Healthcare 2007 General Considerations GE Healthcare 2007 Protecting the Detector Repeated imaging of a stationary • object may lead to formation of “ghost” image. (2.5 mm thick) E.g., HVL, kVp tests. – Cover detector with • steel & lead plate 235 mm (provided) when images not needed. 233 mm GE Healthcare 2007 Order of Performing Tests 1. Flat Field test (RT Test, Chap. 1) but not Phantom IQ tests. – 2. Artifact Evaluation; Flat Field Uniformity (MP Test, Chap. 2) 3. Remaining tests including Phantom IQ tests, Chap. 1 – Minimize artifacts caused by testing. GE Healthcare 2007 Analyzing Images Images displayed after acquisition • are in logarithmic format. Labeled “Proces” in Browser. – Quantitative tests must be performed • on “Raw” images. CNR Test – MTF Measurements – AOP Mode and SNR Check – Automatic image selection for RT Tests on Seno DS and Essential GE Healthcare 2007 Raw or Processed Image? Annotation Level “Full” or “Partial” Processing Description • “PROC_0,” “PROC_1,” etc., then Processed • None, then Raw GE Healthcare 2007 Seno DS & Essential: FineView From the QC Manual: “… a physicist’s measurements (e.g. MTF and noise) performed using methods other than those described in this manual can be affected when FineView processing is applied.” • FineView compensates for the detector MTF. • With FineView enabled, measurement procedures differing from the QC Manual or QAP Tool may give unexpected results. • Disable Fine View for Sub-system MTF. Check FineView before doing independent tests. GE Healthcare 2007 The QC Tests Tests also done by Rad. Tech. GE Healthcare 2007

Description:
– AOP Mode and SNR Check Automatic image selection for RT Tests on Seno DS and Essential. GE Healthcare 2007 Raw or Processed Image? Annotation Level Sub-System MTF
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.