ebook img

Phase V status report no. 7 and remedial monitoring report no. 22 : 50 Tufts Street, Somerville, Massachusetts / submitted to: UniFirst Corp. ; submitted by: GEI Consultants, Inc PDF

2015·19.9 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Phase V status report no. 7 and remedial monitoring report no. 22 : 50 Tufts Street, Somerville, Massachusetts / submitted to: UniFirst Corp. ; submitted by: GEI Consultants, Inc

fMIl i« a /> jy 140 Geotechnical Environmental Water Resources Ecological MassDEP RTN 3-23246 Phase V Status Report No. 7 and Remedial Monitoring Report No. 22 50 Tufts Street, Somerville, Massachusetts Submitted to: UniFirst Corporation 68 Jonspin Road Wilmington, MA 01887 fter Submitted by: GEI Consultants, Inc. 400 Unicorn Park Drive Woburn, MA 01801 && 781-721-4000 1 February 2, 2015 Project 04516-3 Ileen S. Gladstone, P.E., LSP, LEED AP Senior Principal MassDEP RTN 3-23246 Phase V Status Report No. 7 and Remedial Monitoring Report No. 22 50 Tufts Street, Somerville, Massachusetts UniFirst Corporation February 2, 2015 Table of Contents Acronyms and Abbreviations V vii Executive Summary 1. Introduction 1 1.1 Contact Information 1 1.2 Background 2 1.3 Purpose and Scope 4 1.4 Public Involvement (310 CMR 40.1400) 5 Data Collection 6 2. 2.1 Kleinfelder Investigation 6 2.2 GEI Manhole Sampling 6 2.3 Groundwater Sampling 6 6 2.3.1 GEI 2.3.2 Revised Extent of GW-2 Exceedance for PCE 7 2.3.3 Groundwater Plume Stability 7 2.4 Indoor Air Sampling 7 2.5 Indoor Air Sampling - Checklists and Methods 8 2.6 Meteorological Conditions 8 3. Capuano Center Phase IV Activities 9 9 3.1 Background 9 3.2 Remedial Objectives 3.3 Inspection and Monitoring 9 3.4 Performance Efficiency and Effectiveness 10 3.5 Management of Waste Materials 10 10 3.6 System Modifications 10 3.7 Future Phase V Activities 3.7.1 Impact of 2014 MCP Amendments for Active EPMMs 11 4. Residential and Commercial Properties Phase IV Activities 12 12 4.1 EPMM Installation 4.1.1 Remedial Objectives 13 13 4.2 Option 1 EPMMs 14 4.2.1 Operation and Monitoring 4.2.2 Impact of 2014 MCP Amendments for Active EPMMs 15 4.2.3 Efficiency and Effectiveness 17 4.2.4 System Maintenance and Modifications 17 4.2.5 Management of Waste Materials 17 GEI Consultants, Inc. ii . MassDEP RTN 3-23246 Phase V Status Report No. 7 and Remedial Monitoring Report No. 22 50 Tufts Street, Somerville, Massachusetts UniFirst Corporation February 2, 2015 4.3 Option 2 and 3 EPMMs 17 4.3.1 Operation and Monitoring 18 4.3.2 Efficiency and Effectiveness 19 4.3.3 System Maintenance and Modifications 20 4.3.4 Management of Waste Materials 20 4.4 Activity and Use Limitations 20 4.5 Permanent Solution Statements 20 4.5.1 Permanent Solution without Conditions 21 4.5.2 Permanent Solution with Conditions 21 4.6 Future Phase V Activities 22 4.6.1 EPMM Operation and Monitoring 22 4.6.2 EPMM Modifications 22 4.6.3 EPMM Closure Sampling 22 4.6.4 Installation of New EPMMs 22 4.6.5 AULs and Permanent Solutions 22 5. 60 Tufts Street 24 5.1 Background 24 5.2 Remedial Objectives 24 5.3 Inspection and Monitoring 24 5.4 Performance Efficiency and Effectiveness 25 5.5 Management of Waste Materials 25 5.6 System Modifications 25 5.7 Future Phase V Activities 25 5.7.1 Impact of 2014 MCP Amendments for Active EPMMs 25 6. 50 Tufts Street Property 27 6.1 Background 27 6.2 Remedial Objectives 27 6.3 Inspection and Monitoring 27 6.4 Performance Efficiency and Effectiveness 28 6.5 Management of Waste Materials 28 6.6 System Modifications 29 6.7 Future Phase V Activities 29 6.7.1 Impact of 2014 MCP Amendments for Active EPMMs 29 7. Monitored Natural Attenuation 30 7.1 MNA Program Objectives 30 7.2 MNA Activities 30 8. Remedial Monitoring Report No. 22 32 9. References 33 GEI Consultants, Inc. in MassDEP RTN 3-23246 Phase V Status Report No. 7 and Remedial Monitoring Report No. 22 50 Tufts Street, Somerville, Massachusetts UniFirst Corporation February 2, 2015 Tables_ 2-1 Summary of Groundwater Sampling Activities 2-2 Chemical Testing Results - Groundwater 2-3 Chemical Testing Results - Indoor Air - 29 Knowlton 2-4 Chemical Testing Results - Post-EPMM Indoor Air - 34 Knowlton 2-5 Chemical Testing Results - Post-EPMM Indoor Air - 13 Morton 2- 6 Summary of Meteorological Data During Air Sampling Events 3- 1 Summary of SSDS Monitoring Events - Capuano Center 3- 2 Chemical Testing Results - Indoor and Outdoor Air - Capuano Center 4- 1 Exposure Pathway Mitigation Measure (EPMM) Status 4- 2 Indoor Air Sampling and EPMM Monitoring June 16 through December 15, 2014 5- 1 Summary of SSDS Monitoring Events - 60 Tufts Street 6- 1 Summary of SSDS Monitoring Events - 50 Tufts Street 7- 1 Groundwater Elevations Figures 1-1 Site Location Map • 1- 2 Disposal Site Map and Site Boundary 2- 1 Monitoring Well Locations 2-2 Sub-Slab Soil Vapor and Indoor Air Sampling Locations 4-1 EPMM Installation Progress 4-2 EPMM Mitigation Flow Chart 4-3 Permanent Solution Status 6-1 Combined Influent VOC Concentrations and Cumulative VOC Removal Appendices X MassDEP Transmittal Forms (BWSC-108, BWSC-108As, and BWSC-108Bs) B. Property Owner Notification Letters C. Laboratory Testing Reports D. Pre-Sampling Checklists, Air Sampling Checklists, and Photo Logs E. Field Monitoring Forms and Inspection Logs F. EPMM Inspection Forms MLK/CMM/JDR/ISG:csh N:\04516\15.0 Report Original\15.105 Phase V SR #7 & RMR #22 RTN 3-23246 (Feb 2015)\Phase V SR 7 RMR 22.docx GEI Consultants, Inc. IV *

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.