C427etukansi.kesken.fm Page 1 Thursday, August 16, 2012 11:41 AM C OULU 2012 4 C 427 2 7 UNIVERSITY OF OULU P.O.B. 7500 FI-90014 UNIVERSITY OF OULU FINLAND AACCTTAA A UUNNIIVVEERRSSIITTAATTIISS OOUULLUUEENNSSIISS A C T A U N I V E R S I T A T I S O U L U E N S I S C T A CC S E R I E S E D I T O R S TTEECCHHNNIICCAA Tapani Koivukangas A SCIENTIAE RERUM NATURALIUM T METHODS FOR a B Senior Assistant Jorma Arhippainen p a n DETERMINATION OF HUMANIORA i K o C Lecturer Santeri Palviainen iv THE ACCURACY OF SURGICAL u TECHNICA k a n GUIDANCE DEVICES D Professor Hannu Heusala g a s MEDICA A STUDY IN THE REGION OF NEUROSURGICAL E Professor Olli Vuolteenaho INTEREST SCIENTIAE RERUM SOCIALIUM F Senior Researcher Eila Estola SCRIPTA ACADEMICA G Director Sinikka Eskelinen OECONOMICA Professor Jari Juga EDITOR IN CHIEF Professor Olli Vuolteenaho PUBLICATIONS EDITOR Publications Editor Kirsti Nurkkala UNIVERSITY OF OULU GRADUATE SCHOOL; UNIVERSITY OF OULU, FACULTY OF TECHNOLOGY, DEPARTMENT OF MECHANICAL ENGINEERING; ISBN 978-951-42-9903-2 (Paperback) FACULTY OF MEDICINE, INSTITUTE OF CLINICAL MEDICINE, DEPARTMENT OF NEUROSURGERY ISBN 978-951-42-9904-9 (PDF) ISSN 0355-3213 (Print) ISSN 1796-2226 (Online) ACTA UNIVERSITATIS OULUENSIS C Technica 427 TAPANI KOIVUKANGAS METHODS FOR DETERMINATION OF THE ACCURACY OF SURGICAL GUIDANCE DEVICES A study in the region of neurosurgical interest Academic dissertation to be presented with the assent of the Doctoral Training Committee of Technology and Natural Sciences of the University of Oulu for public defence in OP-sali (Auditorium L10), Linnanmaa, on 21 September 2012, at 12 noon UNIVERSITY OF OULU, OULU 2012 Copyright © 2012 Acta Univ. Oul. C 427, 2012 Supervised by Professor Kalervo Nevala Reviewed by Doctor Erkki Vahala Doctor Jani Virtanen ISBN 978-951-42-9903-2 (Paperback) ISBN 978-951-42-9904-9 (PDF) ISSN 0355-3213 (Printed) ISSN 1796-2226 (Online) Cover Design Raimo Ahonen JUVENES PRINT TAMPERE 2012 Koivukangas, Tapani, Methods for determination of the accuracy of surgical guidance devices. A study in the region of neurosurgical interest University of Oulu Graduate School; University of Oulu, Faculty of Technology, Department of Mechanical Engineering; Faculty of Medicine, Institute of Clinical Medicine, Department of Neurosurgery, P.O. Box 5000, FI-90014 University of Oulu, Finland Acta Univ. Oul. C 427, 2012 Oulu, Finland Abstract Minimally invasive surgery (MIS) techniques have seen rapid growth as methods for improved operational procedures. The main technology of MIS is based on image guided surgery (IGS) devices, namely surgical navigators, surgical robotics and image scanners. With their widespread use in various fields of surgery, methods and tools that may be used routinely in the hospital setting for “real world” assessment of the accuracy of these devices are lacking. In this thesis the concept of accuracy testing was developed to meet the needs of quality assurance of navigators and robots in a hospital environment. Thus, accuracy was defined as the difference between actual and measured distances from an origin, also including determination of directional accuracy within a specific volume. Two precision engineered accuracy assessment phantoms with assessment protocols were developed as advanced materials and methods for the community. The phantoms were designed to include a common region of surgical interest (ROSI) that was determined to roughly mimic the size of the human head. These tools and methods were utilized in accuracy assessment of two commercial navigators, both enabling the two most widely used tracking modalities, namely the optical tracking system (OTS) and the electromagnetic tracking system (EMTS). Also a study of the accuracy and repeatability of a prototype surgical interactive robot (SIRO) was done. Finally, the phantoms were utilized in spatial accuracy assessment of a commercial surgical 3D CT scanner, the O-Arm. The experimental results indicate that the proposed definitions, tools and methods fulfill the requirements of quality assurance of IGS devices in the hospital setting. The OTS and EMTS tracking modalities were nearly identical in overall accuracy but had unique error trends. Also, the accuracy of the prototype robot SIRO was in the range recommended in the IGS community. Finally, the image quality of the O-Arm could be analyzed using the developed phantoms. Based on the accuracy assessment results, suggestions were made when setting up each IGS device for surgical procedures and for new applications in minimally invasive surgery. Keywords: accuracy assessment phantom, accuracy assessment protocol, image-guided surgery, medical imaging, region of surgical interest (ROSI), surgical navigation, surgical robotics Koivukangas, Tapani, Kirurgisten paikannuslaitteiden tarkkuudenmääritys- menetelmiä. Tutkimus neurokirurgisessa kohdealueessa Oulun yliopiston tutkijakoulu; Oulun yliopisto, Teknillinen tiedekunta, Konetekniikan osasto; Lääketieteellinen tiedekunta, Kliinisen lääketieteen laitos, Neurokirurgia, PL 5000, 90014 Oulun yliopisto Acta Univ. Oul. C 427, 2012 Oulu Tiivistelmä Mini-invasiivisen eli täsmäkirurgian tekniikoita ja teknologioita on alettu hyödyntää viime aikoi- na yhä enemmän. Tavoitteena on ollut parantaa kirurgisten operaatioiden tarkkuutta ja turvalli- suutta. Täsmäkirurgiassa käytetyt teknologiat pohjautuvat kuvaohjattuihin kirurgisiin paikannus- laitteisiin. Kuvaohjattuihin laitteisiin kuuluvat navigaattorit, kirurgiset robotit ja kuvantalaitteet. Näiden laitteistojen kehittyminen on mahdollistanut tekniikoiden hyödyntämisen monialaisessa kirurgiassa. Paikannuslaitteistojen ja robottien yleistyminen on kuitenkin nostanut sairaaloissa esiin yleisen ongelman paikannustarkkuuden määrittämisessä käytännön olosuhteissa. Tässä väitöskirjassa esitetään kirurgisten yksiköiden käyttöön menetelmä sekä kaksi uutta fantomia ja protokollaa käytössä olevien paikannuslaitteistojen tarkkuuden määrittämiseen. Fan- tomit suunniteltiin sisältämään ennalta määritetty kirurginen kohdealue, mikä rajattiin käsittä- mään ihmisen kallon tilavuus. Fantomeita ja protokollaa hyödynnettiin kahden kaupallisen pai- kannuslaitteen tarkkuuden määrityksessä. Navigaattorit käyttivät optiseen ja elektromagneetti- seen paikannukseen perustuvaa tekniikkaa. Lisäksi työssä kehitetyillä menetelmillä tutkittiin prototyyppivaiheessa olevan kirurgisen robotin paikannus- ja toistotarkkuutta sekä tietokoneto- mografialaitteen O-kaaren kuvan tarkkuuden määritystä. Kokeellisten tulosten perusteella työssä kehitetyt fantomit ja protokollat ovat luotettavia ja tarkkoja menetelmiä kirurgisten paikannuslaitteistojen tarkkuuden määrittämiseen sairaalaolois- sa. Kirurgisten navigaattoreiden tarkkuuden määritystulokset osoittivat optisen ja elektromag- neettisen paikannustekniikan olevan lähes yhtä tarkkoja. Prototyyppirobotin tarkkuus oli tulos- ten perusteella kirjallisuudessa esitettyjen suosituksien mukainen. Lisäksi O-kaaren kuvanlaatua voitiin tutkia kehitetyillä fantomeilla. Tarkkuudenmääritystulosten perusteella työssä ehdotetaan menetelmiä laitteistojen optimaalisesta käytöstä leikkaussalissa sekä laajennetaan niiden käyttö- mahdollisuuksia. Tuloksia voidaan hyödyntää myös paikannuslaitteistojen kehittämistyössä. Asiasanat: kirurginen kohdealue, kirurginen navigointi, kirurginen robotiikka, kuvaohjattu kirurgia, lääketieteellinen kuvantaminen, tarkkuudenmääritysfantomi, tarkkuudenmääritysprotokolla To my family 8
Description: