ProtoNode RER and ProtoNode LER Startup Guide For Interfacing Product: Lochinvar’s Armor®, SYNC™/Armor X2, Knight®/Knight XL®, Crest®, Copper-Fin II ® boilers To Building Automation Systems Utilizing: Protocols: BACnet MS/TP, BACnet IP, Modbus TCP, and LonWorks APPLICABILITY & EFFECTIVITY Explains the ProtoNode RER and LER hardware and how to install it. The instructions are effective for the above as of November 2012 Document Revision: 5 INS70085 Lochinvar Startup Guide Page 2 of 38 Technical Support: Thank you for purchasing the ProtoNode for Lochnivar Boilers. Please call Lochinvar for Technical support of the ProtoNode product. FieldServer will not field the first phone call. If the call needs escalating, Lochinvar bring FieldServer in to help solve problem. Lochnivar’s contact information: Lochinvar, LLC 300 Maddox Simpson Pkwy. Lebanon, TN 37090 Phone: 1-800-722-2101 Technical Service email: [email protected] www.lochinvar.com ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected] INS70085 Lochinvar Startup Guide Page 3 of 38 TABLE OF CONTENTS 1 Introduction ................................................................................................................................................... 5 1.1 BTL Mark – BACnet Testing Laboratory........................................................................................................ 5 1.2 LonMark3 Certification ................................................................................................................................. 5 2 BACnet/LonWorks Setup through ProtoCessor ProtoNode RER/LER .............................................................. 6 2.1 Installation steps for the customer .............................................................................................................. 6 2.2 Record Identification Data ........................................................................................................................... 6 2.3 Setting Modbus RTU Settings on Lochinvar’s Modbus COM Board ............................................................. 7 2.4 Configure the DIP Switches .......................................................................................................................... 7 2.4.1 Setting the Node/ID Device Instance (DIP Switch A0 – A7) for BACnet MS/TP & BACnet/IP ................... 7 2.4.2 Setting the Serial Baud Rate (DIP Switch B0 – B3) for BACnet MS/TP ..................................................... 8 2.4.3 Using S0 – S3 bank of DIP Switches to select and load Configuration Files ............................................. 8 3 Interfacing the ProtoNode to Lochinvar boilers ............................................................................................ 10 3.1 ProtoNode RER and LER component layout with the cover removed ....................................................... 10 3.2 Wiring Connections to ProtoNode RER and LER ........................................................................................ 10 3.2.1 Lochinvar’s Armor, SYNC/Armor X2, Knight/Knight XL, Crest, and Copper-Fin II Low Voltage Modbus RTU Connection Wiring to the ProtoNode: .......................................................................................................... 12 3.3 Wiring the ProtoNode RER to RS-485 Field Protocol ................................................................................. 13 3.4 Wiring the ProtoNode LER Field Port to a LonWorks network .................................................................. 14 3.5 Power-Up the ProtoNode RER or LER ........................................................................................................ 14 4 Commissioning the ProtoNode LER on a LonWorks network ........................................................................ 15 4.1 Commissioning the ProtoNode LER on a LonWorks network .................................................................... 15 4.1.1 Instructions to Upload XIF File From the ProtoNode LER Using FS GUI Web Server .............................. 15 5 Connect the ProtoNode’s Web GUI to Setup IP Address for BACnet/IP ........................................................ 17 5.1 Connect the PC to the ProtoNode via the Ethernet port ........................................................................... 17 5.2 Use the ProtoNode Web GUI to Connect to the ProtoNode ..................................................................... 18 5.3 Set IP Address for BACnet/IP TCP via GUI .................................................................................................. 18 6 Chipkin Automation’s CAS BACnet Explorer for validating the ProtoNode in the field on a BACnet MS/TP or BACnet/IP network .............................................................................................................................................. 20 6.1 Downloading Chipkin Automation’s CAS Explorer and Requesting an Activation Key .............................. 20 6.2 CAS BACnet Setup ...................................................................................................................................... 21 6.2.1 CAS BACnet MS/TP Setup ....................................................................................................................... 21 6.2.2 CAS BACnet BACnet/IP Setup ................................................................................................................. 21 Appendix A. Troubleshooting Tips ....................................................................................................................... 22 Appendix A.1. Check Wiring and Settings ................................................................................................................ 22 Appendix A.2. Take Log With Our FieldServer Utilities............................................................................................ 22 Appendix A.3. LED Diagnostics for Modbus RTU Communications between the ProtoNode and the Lochinvar Controller’s .............................................................................................................................................................. 25 A.3.1 ProtoNode RER and LER LEDs .................................................................................................................... 25 Appendix A.4. Sync Modbus RTU Mappings to BACnet MS/TP, BACnet IP, and LonWorks .................................... 25 Appendix A.5. Knight Modbus RTU Mappings to BACnet MS/TP, BACnet IP, and LonWorks ................................. 27 Appendix A.6. Crest Modbus RTU Mappings to BACnet MS/TP, BACnet IP, and LonWorks ................................... 28 Appendix A.7. Copper-Fin II Modbus RTU Mappings to BACnet MS/TP, BACnet IP, and LonWorks ..................... 29 Appendix B. Reference ........................................................................................................................................ 31 Appendix B.1. Specifications .................................................................................................................................... 31 ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected] INS70085 Lochinvar Startup Guide Page 4 of 38 Appendix B.1.1. Compliance with UL Regulations ............................................................................................ 31 Appendix B.2. Address DIP Switch Settings ............................................................................................................. 32 Appendix C. Limited 2 year Warranty .................................................................................................................. 38 LIST OF FIGURES Figure 1: Lochinvar’s Modbus RTU settings for all of their boilers ................................................................................ 7 Figure 2: Lochinvar’s Modbus COM board showing serial DIP switches ....................................................................... 7 Figure 3: A0 – A7 DIP Switches for setting Device Instance/MAC Address ................................................................... 8 Figure 4: B0 – B3 DIP Switches for setting the baud rate on BACnet MS/TP................................................................. 8 Figure 5: S0 – S3 DIP Switches for selecting the proper configuration for each of Lochinvar’s Boilers ........................ 8 Figure 6: ProtoNode component layout ...................................................................................................................... 10 Figure 7: Pin outs for the Lochinvar’s Modbus RS-485 port and power to the ProtoNode ......................................... 11 Figure 8: Connection from ProtoNode to RS-485 Field Protocol –BACnet MS/TP ...................................................... 13 Figure 9: End-of-line termination on from ProtoNode to RS-485 BMS Field Protocol ................................................ 13 Figure 10: ProtoNode LER LonWorks FFT-10 2 wire screw terminal ........................................................................... 14 Figure 11: ProtoNode power pin outs ......................................................................................................................... 14 Figure 12: Sample of Fserver.XIF file being generated ................................................................................................ 16 Figure 13: Ethernet port location of ProtoNode ......................................................................................................... 17 Figure 14: FST Web GUI screen ................................................................................................................................... 18 Figure 15: FST Web GUI IP Address settings screen .................................................................................................... 19 ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected] INS70085 Lochinvar Startup Guide Page 5 of 38 1 INTRODUCTION ProtoNode is an external, high performance Building Automation multi-protocol gateway that has been preprogrammed for Lochinvar’s Armor®, SYNC™/Armor X2, Knight®/Knight XL®, Crest® and Copper-Fin II ® boilers to support BACnet®1MS/TP, BACnet/IP and LonWorks®2. Configurations for the various protocols are stored within the ProtoNode and are selectable via DIP switches for fast and easy installation. It is not necessary to download any configuration files to support the required applications. This document provides the necessary information to facilitate installation of the ProtoNode. 1.1 BTL Mark – BACnet Testing Laboratory The BTL Mark on the ProtoNode RER is a symbol that indicates that a product has passed a series of rigorous tests conducted by an independent laboratory which verifies that the product correctly implements the BACnet features claimed in the listing. The mark is a symbol of a high-quality BACnet product. Go to http://www.bacnetinternational.net/btl/ for more information about the BACnet Testing Laboratory. 1.2 LonMark3 Certification LonMark International is the recognized authority for certification, education, and promotion of interoperability standards for the benefit of manufacturers, integrators and end users. LonMark International has developed extensive product certification standards and tests to provide the integrator and user with confidence that products from multiple manufacturers utilizing LonMark devices work together. FieldServer Technologies has more LonMark Certified gateways than any other gateway manufacturer, including the ProtoCessor, ProtoCarrier and ProtoNode for OEM applications and the full featured, configurable gateways. 1 BACnet is a registered trademark of ASHRAE 2 LonWorks is a registered trademark of Echelon Corporation 3 LonMark is a registered trademark of LonMark International ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected] INS70085 Lochinvar Startup Guide Page 6 of 38 2 BACNET/LONWORKS SETUP THROUGH PROTOCESSOR PROTONODE RER/LER 2.1 Installation steps for the customer 1. Record the information about the unit. See Section 2.2 2. Set the Modbus RTU COM settings on the Lochinvar Boiler via DIP switches locate on the Modbus RTU card. See Section 2.3 or the Lochinvar manual 3. Set the A, B, and S DIP Switch banks for field protocol baud rate, Node-ID/Device Instance, and proper configuration. See Section 2.4 4. Connect the ProtoNode to the Field protocol port and Lochinvar’s Armor, SYNC/Armor X2, Knight/Knight XL, Crest, and Copper-Fin II port to the ProtoNode’s RS-485 interface. See Section 3 5. Power up the ProtoNode RER and LER. See Section 3.6 6. Commission the ProtoNode on the LonWorks Network. This needs to be done by the LonWorks administrator use a LonWorks Commissioning tool. See Section 4 7. If the Field protocol is BACnet/IP; run the ProtoNode web GUI to change IP. See Section 5 2.2 Record Identification Data Each ProtoNode has a unique part number located on the underside of the unit. The numbers are as follows: Part number FPC-N34-103-126-0614: o Supports Lochinvar’s Armor®, SYNC™/Armor X2, Knight®/Knight XL®, Crest® and Copper-Fin II ® boilers to BACnet MS/TP and BACnet/IP. Part number FPC-N35-103-401-0615: o Supports Lochinvar’s Armor®, SYNC™/Armor X2, Knight®/Knight XL®, Crest® and Copper-Fin II ® boilers to LonWorks. These numbers should be recorded, as they may be required for technical support. ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected] INS70085 Lochinvar Startup Guide Page 7 of 38 2.3 Setting Modbus RTU Settings on Lochinvar’s Modbus COM Board The ProtoNode’s Modbus RTU port has been preprogrammed to support 9600 baud rate, 8 data bit, 2 stop bits, no parity and to look for a Modbus Node-ID of 1 on the Lochinvar boilers. Set the Lochinvar’s Modbus RTU COM setting to match Figure 1 via the DIP switches on the Lochinvar Modbus card. Set the DIP switch 1 to ON and 2-10 to OFF position on the Modbus COM board. This will set the Lochinvar boiler for 9600, 8, 2, N, and Node-ID of 1. Serial Port Setting Armor SYNC/Armor X2 Knight/Knight XL Crest Copper-Fin II Baud Rate 9600 9600 9600 9600 9600 Data Bits 8 8 8 8 8 Stop Bits 2 2 2 2 2 Parity None None None None None Node_ID 1 1 1 1 1 Figure 1: Lochinvar’s Modbus RTU settings for all of their boilers Figure 2: Lochinvar’s Modbus COM board showing serial DIP switches 2.4 Configure the DIP Switches 2.4.1 Setting the Node/ID Device Instance (DIP Switch A0 – A7) for BACnet MS/TP & BACnet/IP The A Bank DIP switches on the ProtoNode RER allow users to set the Node-ID/Device Instance on the Field RS-485. DIP switches A0 – A7 can also be used to set the MAC Address for BACnet MS/TP and BACnet/IP. ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected] INS70085 Lochinvar Startup Guide Page 8 of 38 Figure 3: A0 – A7 DIP Switches for setting Device Instance/MAC Address Please refer to Appendix B.2 for the full range of addresses to set Node-ID/Device Instance. NOTE: When setting DIP Switches, please ensure that power to the board is OFF. 2.4.2 Setting the Serial Baud Rate (DIP Switch B0 – B3) for BACnet MS/TP DIP Switches B0 – B3 can be used to set the serial baud rate to match the baud rate provided by the Building Management System for BACnet MS/TP. B0 B1 B2 B3 Figure 4: B0 – B3 DIP Switches for setting the baud rate on BACnet MS/TP 2.4.2.1 Baud Rate DIP Switch Selection Baud B0 B1 B2 B3 9600 On On On Off 19200 Off Off Off On 38400 On On Off On 57600 Off Off On On 76800 On Off On On 2.4.3 Using S0 – S3 bank of DIP Switches to select and load Configuration Files The S bank of DIP switches, S0 - S3 is used to select and load a configuration file from a group of pretested/preloaded configuration files which are stored in the ProtoNode RER (BACnet MS/TP & BACnet/IP) and LER (LonWorks). S0 S1 S2 S3 Figure 5: S0 – S3 DIP Switches for selecting the proper configuration for each of Lochinvar’s Boilers 2.4.3.1 S0 – S3 DIP Switch Configuration Settings S Bank DIP Switches ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected] INS70085 Lochinvar Startup Guide Page 9 of 38 A. BACnet MS/TP and BACnet IP The following chart describes S0 - S3 DIP Switch settings for Lochinvar’s SYNC/Armor X2, Knight, Crest, and Cooper- fin II boilers to support BACnet MS/TP and BACnet/IP (FPC-N34). ProtoNode RER FPC-N34-103-126-0614 S0 S1 S2 S3 BACnet IP/BACnet MSTP/Modbus TCP SYNC/ Armor X2 Off Off Off Off Deg_C BACnet IP/BACnet MSTP/Modbus TCP Knight/Knight On Off Off Off XL/Armor/Wall Mount/Wall Hung Deg_C BACnet IP/BACnet MSTP/Modbus TCP Crest Deg_C Off On Off Off BACnet IP/BACnet MSTP/Modbus TCP Copper-Fin II Deg_C On On Off Off BACnet IP/BACnet MSTP/Modbus TCP SYNC/Armor X2 Deg_F O f f Off On Off BACnet IP/BACnet MSTP/Modbus TCP Knight/Knight On Off On Off XL/Armor/Wall Mount/Wall Hung Deg_F BACnet IP/BACnet MSTP/Modbus TCP Crest Deg_F Off On On Off BACnet IP/BACnet MSTP/Modbus TCP Copper-Fin II Deg_F On On On Off B. LonWorks The following chart describes S0 – S3 DIP Switch configuration settings for Lochinvar’s Armor, SYNC, Knight/Knight XL, Crest, and Cooper-fin II boilers to support LonWorks on a ProtoNode LER (FPC-N35). S0 S1 S2 S3 ProtoNode LER FPC-N35-103-401-0615 LonWorks SYNC/Armor X2 Off Off Off Off LonWorks Knight/Knight XL/Armor/Wall Mount/Wall Hung On Off Off Off LonWorks Crest Off On Off Off LonWorks Copper-Fin II On On Off Off NOTE: When setting DIP Switches, please ensure that power to the board is OFF. ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected] INS70085 Lochinvar Startup Guide Page 10 of 38 3 INTERFACING THE PROTONODE TO LOCHINVAR BOILERS 3.1 ProtoNode RER and LER component layout with the cover removed Figure 6: ProtoNode component layout 3.2 Wiring Connections to ProtoNode RER and LER ProtoNode 6 Pin Phoenix connector – Pinouts ProtoCessor 1991 Tarob Court Milpitas, California 95035 USA Web: www.protocessor.com Tel: (408) 964 4444 Fax: (408) 964 4425 Toll Free: (800) 317 8319 x141 email: [email protected]
Description: