ebook img

IS 16030: Roasted Ground Coffee - Determination of Moisture Content - Method By Determination of Loss in Mass at 103 Degrees C (Routine Method) PDF

2012·1.1 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview IS 16030: Roasted Ground Coffee - Determination of Moisture Content - Method By Determination of Loss in Mass at 103 Degrees C (Routine Method)

इंटरनेट मानक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. “जान1 का अ+धकार, जी1 का अ+धकार” “प0रा1 को छोड न’ 5 तरफ” Mazdoor Kisan Shakti Sangathan Jawaharlal Nehru “The Right to Information, The Right to Live” “Step Out From the Old to the New” IS 16030 (2012): Roasted Ground Coffee - Determination of Moisture Content - Method By Determination of Loss in Mass at 103 Degrees C (Routine Method) [FAD 6: Stimulant Foods] “!ान $ एक न’ भारत का +नम-ण” Satyanarayan Gangaram Pitroda ““IInnvveenntt aa NNeeww IInnddiiaa UUssiinngg KKnnoowwlleeddggee”” “!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता हहहहै””ै” Bhartṛhari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 16030 : 2012 ISO 11294 : 1994 Hkkjrh; ekud Hkquh filh dkWiQh ueh dh ek=kk Kkr djuk — — lsaVhxzsM ij æO;eku esa {kfr Kkr djus dh i¼fr o 103 (lkekU; i¼fr) Indian Standard ROASTED GROUND COFFEE — DETERMINATION OF MOISTURE CONTENT — METHOD BY DETERMINATION OF LOSS IN MASS AT 103oC (ROUTINE METHOD) ICS 67.140.10 © BIS 2012 B U R E A U O F I N D I A N S T A N D A R D S MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002 December 2012 Price Group 2 Stimulant Foods Sectional Committee, FAD 6 NATIONAL FOREWORD This Indian Standard which is identical with ISO 11294 : 1994 ‘Roasted ground coffee — Determination of moisture content — Method by determination of loss in mass at 103oC (Routine method)’ issued by the International Organization for Standardization (ISO) was adopted by the Bureau of Indian Standards on the recommendation of the Stimulant Foods Sectional Committee and approval of the Food and Agriculture Division Council. The text of ISO Standard has been approved as suitable for publication as an Indian Standard without deviations. Certain conventions are, however, not identical to those used in Indian Standards. Attention is particularly drawn to the following: a) Wherever the words ‘International Standard’ appear referring to this standard, they should be read as ‘Indian Standard’. b) Comma (,) has been used as a decimal marker while in Indian Standards, the current practice is to use a point (.) as the decimal marker. In reporting the result of a test or analysis made in accordance with this standard, if the final value, observed or calculated is to be rounded off, it shall be done in accordance with IS 2 : 1960 ‘Rules for rounding off numerical values (revised)’. INTERNATIONAL STANDARD 0 ISO ISO 11294:1994(E) IS 16030 : 2012 ISO 11294 : 1994 Indian Standard ROASTED GROUND COFFEE — DETERMINATION OF MOISTURE CONTENT — METHOD BY RoastedD EgTroEuRndM INcAofTfeIeO N- OFD eLtOerSmSin aINtio Mn ASSof AmTo 1is0tu3roeC content - Method (RbyO UdeTteINrmEin MatiEonT HODof) loss in mass at 103 “C (Routine method) 1 Scope 4.1 Oven, electrically heated, capable of being op- erated at 103 “C -+ 1 “C. This International Standard specifies a routine method for the determination of loss in mass at 103 “C of 4.2 Dish, made of corrosion-resistant metal or of roasted ground coffee. glass, with lid and an effective surface area of at least 18 cm2 (for example, 50 mm minimum diameter and NOTE 1 This method has been shown to give very similar 25 mm to 30 mm deep). results on average to those obtained by the method given in ISO 11817:-, Roasted ground coffee - Determination of mois ture con ten t - Karl Fischer method (Reference 4.3 Desiccator, containing an effective desiccant. me thod). This method is most suited to degassed roasted 4.4 Analytical balance, capable of weighing to ground coffee, because of the presence of volatile 0,i mg. matter, especially carbon dioxide, in variable quanti- ties in roasted coffee. 5 Sampling 2 Definition lt is important that the laboratoty receive a Sample which is truly representative and has not been dam- For the purposes of this International Standard, the aged or changed during transport or storage. following definition applies. 2.1 loss in mass at 103 “C: Loss in mass caused 6 Preparation of test Sample principally by water and volatile matter (carbon diox- ide, volatile acids, etc.) which are vaporized under the Mix thoroughly the laboratory Sample. conditions specified in this International Standard. Loss in mass is expressed as a percentage by mass. 7 Procedure 3 Principle 7.1 Preparation of the dish Heating a test Portion at 103 “C -+ 1 “C for 2 h at at- Dry the dish (4.2) and its lid for 1 h in the oven (4.1) mospheric pressure. set at 103 “C. Remove the dish and its lid from the oven and allow 4 Apparatus them to cool to room temperature in the desiccator (4.3). Usual laboratory apparatus and, in particular, the fol- lowing. Weigh the dish and its lid to the nearest 0,l mg. 1 ISO 11294:1994(E) 0 ISO IS 16030 : 2012 ISO 11294 : 1994 7.2 Test Portion 9.1 Repeatability Place approximately 5 g of the test Sample The absolute differente between two independent (clause 6) in the prepared dish (7.1). test results, obtained using the same method on identical test material in the Same laboratory by the Cover the dish with its lid and weigh the dish, lid and Same Operator using the Same equipment within a contents to the nearest 0,l mg. short interval of time, should not be greater than 0,i %. 7.3 Determination 9.2 Reproducibility Place the dish containing the test Portion, with the lid removed but alongside or beneath the dish, in the The absolute differente between two Single test re- oven (4.1) set at 103 “C, and dry for 2 h +- 0,i h. sults, obtained using the same method on identical test material in different laboratories with different Remove the dish, fit the lid and place them in the Operators using different equipment, should not be desiccator (4.3). Allow the dish, lid and contents to greater than 0,5 %. cool to room temperature and then weigh them to the nearest 0,l mg. NOTE 2 The reproducibility of the test method is such that the method is less suitable for rokted ground coffees 8 Expression of test results with low moisture contents (below approx. 2 % moisture). The loss in mass at 103 “C, expressed as percentage by mass of the Sample, is calculated according to the 10 Test report following formula: The test report shall specify (m , -5) x 100 m1 -mo - the method used, where - the test result obtained, and Q is the mass, in grams, of the dish and lid - if the repeatability has been checked, the final (see 7.1); quoted result obtained. m1 is the mass, in grams, of the dish, test lt shall also mention any operating details not speci- Portion and lid before drying (see 7.2); fied in this International Standard, or regarded as op- 9 is the mass, in grams, of the dish, test tional, as well as any circumstances that may have Portion and lid after drying (see 7.3). influenced the result. The test report shall include all information required 9 Precision for the complete identification of the Sample. Results of an interlaboratory test are given in annex A. 2 ISO 11294:1994(E) IS 16030 : 2012 ISO 11294 : 1994 Annex A (informative) Results of interlaboratory test An interlaboratory test carried out in 1989, in which 15 laboratories participated, each of which carried out three determinations on each Sample, gave the statistical results (evaluated in accordance with ISO 5725’)) shown in tableA.l. In the same interlaboratory test, the same laboratories determined the true moisture content by the Karl Fischer method of ISO 11817. TableA.2 Shows the comparison of mean values obtained for each Sample by the two methods. Table A.l - Determination of loss in mass for roasted ground coffee Sample A B C D E Number of laboratories retained after eliminating outliers 15 15 14 15 15 Mean loss in mass, % (m/m) 4,98 4,54 3,20 1,56 1,50 Standard deviation of repeatability, sr 0,031 0,011 0,027 0,027 0,021 Coefficient of Variation of repeatability, % 0,6 03 03 lt7 114 Repeatability 2,83s, 0,09 0,12 0,08 0,08 0,06 Standard deviation of reproducibility, sR 0,187 0,168 0,281 0,187 0,154 Coefficient of Variation of reproducibility, % Reproducibility 2,83s, Table A.2 - Comparison of loss in mass values with moisture content values determined by the Karl Fischer method Sample A B C D E Mean loss in mass, % (m/m) 4,98 4,54 3,20 1,56 1,50 Mean moisture content, % (m/m) 5,07 4,64 3,32 1,51 1,44 1) ISO 5725:1986, Precision of test methods - Determination of repeatability and reproducibility for a Standard test method by in ter-labora tory tes ts. 3 Bureau of Indian Standards BIS is a statutory institution established under the Bureau of Indian Standards Act, 1986 to promote harmonious development of the activities of standardization, marking and quality certification of goods and attending to connected matters in the country. Copyright BIS has the copyright of all its publications. No part of these publications may be reproduced in any form without the prior permission in writing of BIS. This does not preclude the free use, in course of imple- menting the standard, of necessary details, such as symbols and sizes, type or grade designations. Enquiries relating to copyright be addressed to the Director (Publications), BIS. Review of Indian Standards Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of ‘BIS Catalogue’ and ‘Standards: Monthly Additions’. This Indian Standard has been developed from Doc No.: FAD 6 (2028). Amendments Issued Since Publication ______________________________________________________________________________________ Amendment No. Date of Issue Text Affected ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ BUREAU OF INDIAN STANDARDS Headquarters: Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002 Telephones: 2323 0131, 2323 3375, 2323 9402 Website: www.bis.org.in Regional Offices: Telephones Central : Manak Bhavan, 9 Bahadur Shah Zafar Marg {2323 7617 NEW DELHI110002 2323 3841 Eastern : 1/14, C.I.T. Scheme VII M, V.I.P. Road, Kankurgachi {2337 8499, 2337 8561 KOLKATA700054 2337 8626, 2337 9120 Northern : SCO 335-336, Sector 34-A, CHANDIGARH160022 {260 3843 260 9285 Southern : C.I.T. Campus, IV Cross Road, CHENNAI600113 {2254 1216, 2254 1442 2254 2519, 2254 2315 Western : Manakalaya, E9 MIDC, Marol, Andheri (East) {2832 9295, 2832 7858 MUMBAI400093 2832 7891, 2832 7892 Branches:AHMEDABAD. BANGALORE. BHOPAL. BHUBANESHWAR. COIMBATORE. DEHRADUN. FARIDABAD. GHAZIABAD. GUW AHATI. HYDERABAD. JAIPUR. KANPUR. LUCKNOW. NAGPUR.PARWANOO.PATNA.PUNE.RAJKOT.THIRUVANATHAPURAM.VISAKHAPATNAM. Published by BIS, New Delhi

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.