ebook img

IS 15785: Code of practice for Installation and maintenance of lift without conventional machine rooms PDF

2007·6.1 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview IS 15785: Code of practice for Installation and maintenance of lift without conventional machine rooms

इंटरनेट मानक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. “जान1 का अ+धकार, जी1 का अ+धकार” “प0रा1 को छोड न’ 5 तरफ” Mazdoor Kisan Shakti Sangathan Jawaharlal Nehru “The Right to Information, The Right to Live” “Step Out From the Old to the New” IS 15785 (2007): Code of practice for Installation and maintenance of lift without conventional machine rooms [ETD 25: Lift and Escalators] “!ान $ एक न’ भारत का +नम-ण” Satyanarayan Gangaram Pitroda ““IInnvveenntt aa NNeeww IInnddiiaa UUssiinngg KKnnoowwlleeddggee”” “!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता हहहहै””ै” Bhartṛhari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 15785 : 2007 ~cpan®~~~ (f~~-~-~~ Indian Standard INSTALLATION AND MAINTENANCE OF LIFT WITHOUT CONVENTIONAL MACHINE ROOMS CODE OF PRACTICE res 91.140.90 © BIS2007 BUREAU OF INDIAN STANDARDS MANAK BHAVAN. 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002 September 2007 PriceGroup5 LiftsandEscalators Sectional Committee,ET25 FOREWORD ThisIndianStandard wasadopted by the Bureau ofIndian Standards, after the draftfinalized by the Liftsand EscalatorsSectionalCommitteehad beenapproved by the Electrotechnical DivisionCouncil. Conventionalliftrequiresseparate machineroomandspecialpulleyrooms,whereverneeded. Modem technology showsthatmachinesandassociated partscan belocated inthewell,onthecar orincabinets.Need hastherefore beenfelttoprepare thisCode toregulate theinstallation andfor safe workingof'Liftswithoutmachine room'. IntheformulationofthisCode, assistance hasbeenderived from the following : a) EN81-l / PrA2 - 2000 Safety rules for the construction and installation of lifts - Part 1:Electric lifts- A2;Lifts without machine room; RefCEN TCIOdated2000-0I secretariatAFNOR,and b) European Parliament andCouncil Directive 95116IECof29June 1995. Thisstandarddoes notcoveroutline dimension ofliftswells,lift pitsandotherlayoutdimensionsnecessaryfor liftinstallations.These arecovered inIS 14665(Part I):2000. Thisstandard isoneofaseriesofIndian Standards on lifts. Otherstandards published inthisseries are: ISNo. Title 14665(Partl) :2000 Electrictractionlifts: Guidelines foroutline dimensions of passenger,goods, service and hospital lifts (Part2/See Iand2):2000 Code of practice for installation, Section I Passenger and goods lifts; Section2Servicelifts (Part3/Sec Iand2):2000 Safetyrules,Section IPassenger andgoods lifts;Section 2Service lifts Forthepurposeofdeciding whether aparticular requirementofthisstandardiscomplied with. the final value. observedorcalculated.expressingtheresultofatestoranalysis.shallberoundedoffinaccordance withIS2:1960 'Rulesforroundingoffnumerical values(revised)'. Thenumber ofsignificantplaces retainedintheroundedoff valueshouldbethesame as thatof thespecified valueinthisstandard. AMENDMENT NO. 1 JUNE 2011 TO IS 15785 : 2007 INSTALLATION AND MAINTENANCE OF LIFT WITHOUT CONVENTIONAL MACHINE ROOMS — CODE OF PRACTICE (Page 2, clause 4.4.5, Title) — Substitute ‘Suspension Media’ for the existing. (Page 2, clause 4.4.5, para 4) — Substitute the following for the existing: ‘Coated Steel Belts (CSB) used shall comply with Annex B. Ratio of sheave diameter to steel cord shall remain 40 : 1 and minimum factor of safety on CSB breaking strength shall be 12. Minimum 2 CSB's shall be used. Each Lift shall be provided with detection device or mechanism which will bring elevator to stop in case of elongation of belt or breakage of one belt. The device shall not be of automatic reset type and shall require intervention of competent person to reset the same.’ (Page 9, Annex B, clause B-7.2.2.7) — Add the following new clause: ‘B-7.3 Visual Check and Replacement Criteria CSB's shall be inspected visually. If any of the following defects are observed in visual inspection, all the CSB's shall be replaced: - Visual damage such as a kink in CSB, exposed cords, excessive elastomeric coating wear, etc - Steel cords, strands or wires breaking through its elastomeric coating - Piercing of CSB by foreign object - Damaged CSB edge where outermost cord is visible.’ (ET 25) Reprography Unit, BIS, New Delhi, India IS15785:2007 Indian Standard INSTALLATIONAND MAINTENANCE OF LIFT WITHOUT CONVENTIONAL MACHINE ROOMS CODE OF PRACTICE 1SCOPE 4 CONSTRUCTION, INSTALLATION, PRO TECTION AND MAINTENANCE OF LIFTS Thisstandarddealswithspeciallifts,wherethehoisting WITHOUTMACHINE ROOM machine is kept inside the shaft itself, thereby eliminating the conventional machine room. This 4.1Everyliftandpartthereofshallbeofsoundmaterial standard is intended to help the potential users, of sufficient rating and construction and sufficient manufacturerand the regulatory authorities who are mechanical strength for the purpose for which it is already familiar with electric lifts complying with intendedandshallbeinstalled,protected,operatedand existingstandards [seeIS 14665 (Part 2/Sec I and 2) maintained insuch mannersoastopreventdanger. and IS 14665(Part3/Sec I and 2)] fortraction lifts. 4.2 Protection isdefinedas preventing damage tothe personnel using theelevatorand maintaining thelift. 2REFERENCES 4.3Allmaterialsusedinliftsshallconformtothelatest Thefollowing standardsarenecessaryadjunctstothis standards,whereverapplicable. standard: ISNo. TItle 4.4Construction 1356(Part I): Electrical equipment of machine 4.4.1 liftMachine 1972 tools:Part I Electrical equipmentof machines for general use (second Each elevatorshould havea machine ofitsown.The revision) liftmachinecan beoperatedbyanelectric motor.The 8216: 1976 Guideforinspectionofliftwireropes speed reduction/control can be either by mechanical 14665 Electrictraction lifts: gears orbyelectrical means. (Part2/Sec I Code of practice for installation, 4.4.2Braking System and2):2000 operationandmaintenance,SectionI Passengerand goods lifts; Section2 4.4.2.1 Generalprovisions Servicelifts a) The lift shall be provided with a braking (Part3/Sec I Safetyrules,Section IPassengerand system whichoperatesautomatically: and2):2000 goodslifts;Section 2Service lifts I) in the event ofloss of the mains power (Part41Sec1-9): Components supply;and 2001 2) in the event ofthe loss of the supply to 3TERMINOLOGY controlcircuits. Forthepurpose ofthisstandard,thedefinitionsgiven b) The braking system shall have an electro inIS 14665(Part 2/Sec I)shall generallyapply. mechanical brake (friction type), butmay,in addition, have other braking means (for 3.1NoMachineRoom- This special elevatordoes example,electric). notneedaseparatemachine room. 4.4.2.2 Electro-mechanicalbrake 3.2 Machinery- Equipmenttraditionally placed in a) This brake on its own shall be capable of the machine room. Cabinet(s) for control and drive stopping the machine when the car is system, lift machine, main switch(es), governor and travelling downward atrated speedand with means foremergency operations. the rated load plus 25 percent. In these 3.3MachinerySpace- Space(s)insideoroutsideof conditionstheretardationofthecarshallnot thewell wherethe machineryasawholeorinpartsis exceed that resulting from the operation of placed. thesafety gear orstopping on thebuffer. Allthe mechanicalcomponentsofthebrake 3.4PulleySpace- Space(s) inside or outside ofthe which take part in the application of the wellwhere pulleysare placed. braking action on the drum or discshall be IS15785:2007 installedintwosets.Ifoneofthecomponents notapply,ifthefollowingthreeconditionsarefulfilled: is not working a sufficient braking effort to a) Tripping of the over speed governor is slowdown thecar, travellingdownwardsat effectedbymeansofaremotecontrol,except ratedspeedandwithratedloadshallcontinue cableless, from outside the well whereby an tobeexercised. involuntary tripping is not affected and the Any solenoid plunger is considered to be a actuation device is not accessible to mechanicalpart,any solenoidcoil isnot. unauthorized persons; b) Thecomponenton which the brake operates b) Over speed governor is accessible for shallbecoupledtothetractionsheaveordrum inspection and maintenancefrom the roofof orsprocketbydirectandpositivemechanical thecar or from the pit;and means. c) After tripping automatically, the over speed c) A continuous flow ofcurrent is required to governorreturnsinto the normal position,as hold offthe brake when the li!t is in normal thecar, is moved in the upward direction. use. Howevertheelectricalparts mayreturnintothenormal d) The interruption of this current shall be positionbyremotecontrolfrom theoutsideofthewell effectedbyatleasttwoindependentelectrical which shall not influence the normal function ofthe devices, whether or not integral with those, over speed governor. which cause interruption of the current feeding the lift machine. If, whilstthe lift is 4.4.5 Suspension Ropes stationary, one of the contactors has not Round steel wirerope orsyntheticropeorcoatedsteel openedthemaincontacts,furthermovement belts can be allowed for suspension of the car and of the car shall be prevented at the latest at counterweight. the nextchangein thedirectionofmotion. e) Whenthemotoroftheliftislikelytofunction Steel wire ropes shall conform to IS 14665 (Part 4/ asagenerator,itshall notbepossibleforthe Sec 8). electric device operating the brake to befed SyntheticropesusedshallcomplywithAnnexA.Ratio bythedriving motor. of sheave diameter to diameter of rope shall be t) Braking shall become effective without minimum25:I and minimum factorofsafety on rope supplementary delay after opening of the breakingstrengthwill be 16. brake release circuit. Coatedsteelbelts(CSB) usedshallcomply withAnnex NaTE- The useofa diode orcapacitorconnected directly to the terminals of the brake coil is not B.Ratio ofsheavediametertosteel chordwillremain consideredasameansofdelay. 40:I and minimum factor ofsafety onCSB breaking g) Anymachinefittedwithamanual emergency strengthwill be 12. operatingdevice(see 5.1.1)shall becapable 4.4.6 Guide RailsandGuide Shoes of having the brake released by hand and require a constant effort to keep the brake Guide rails and guide shoes shall generally conform open. toIS 14665 (Part 4/Sec 2). h) The brake shoe or pad pressure shall be 4.4.7 CarDoors,LandingDoorsandLockingDevices exerted by guided compression springs or weights. The requirementsspecifiedin IS 14665(Part4/Sec6) j) Band brakesshall not beused. shall apply. k) Brake linings shall be incombustible. 4.4.8 TerminalStoppingandFinalLimit Switch 4.4.3Lift Car Every liftshall beprovidedwith upperandlowerfinal The liftcarsand frames whereverprovidedshall meet limit switches arranged tostop the car automatically the requirementsspecifiedinIS 14665(Part 4/Sec 3). within the limits oftop car clearance and bottom car run by from any speed attained in normal operation. Thecarframemaybeintegrated withthecarenclosure. Such limit switches shall act independent of normal 4.4.4 OverSpeed Governor(OSG) limit switches,whereverprovided. The requirementspecified in IS 14665 (Part 4/Sec 4) 4.4.9 Main Switch shall apply. Eachliftshallbeprovidedwithamainswitchandshall The over speed governor shall be accessible and conform toIS 14665 (Part2JSee I). reachablefromoutsidethewell.Thisrequirementdoes 2 IS15785:2007 Thisswitch shall be located: necessary and, if need be, manual emergency operation. a} in the cabinet for control. except if this is mounted inthe well. or b} The clear height for movement shall not be lessthan 1.80m. b} attheemergencyand test panel(s) whenthe cabinetforcontrol ismountedinthewell.If c} There shall be a clear vertical distance ofat theemergencypanel isseparatefromthetest least 0.30m above rotating parts of the panel. the switch shall be at the emergency machine. Thisrequirementdoes notapply if panel. thesepartsaredirectly locatedbelowthewell ceiling. If the main switch is not easily accessible from the cabinetforcontrol, then thecabinetshall beprovided 4.5.2.3 Workingareasinthecaroronthecarroof withan isolatingswitch. a} If maintenance/inspection work on the 4.5Installationand Maintenance machineryistobecarried outfrominsidethe carorfromthecarroof,thefollowingapplies: 4.5.1Access I} Anykindofuncontrolledandunexpected Access to the interior ofthe machinery and pulley car movement resulting from spaces shall be, maintenance/inspection that can be dangerous to persons carrying out a} capableofbeingproperly litbyapermanent maintenance/inspection work shall be electriclight fixture(s}:and prevented by a mechanical device and b} easy to use in complete safety in all electricaldevice. circumstanceswithoutnecessitatingentryinto 2} When the car is blocked against all private premises. movementitshallbepossibletoleavethe 4.5.2Machinery Inside the Well working area easily andsafely. 4.5.2.1Generalprovisions b} Any necessary devices for emergency operationandfordynamictests(suchasbrake a} Machineryspacesinside the wellshall beso tests, traction tests, safety gear tests, buffer constructedtowithstandtheloadsand forces tests or tests of ascending car over speed theyare intendedtobesubjected. protection means) shall be arranged so that b} In the case of wells partially enclosedat the theycanbeoperated fromoutsideofthewell. exteriorofbuildings the machinery shall be suitably protected against environmental 4.5.2.4 Ventilation influences. Themachineryspacesshallbesuitablyventilated.The c} Provision should be given to access the electricequipmentofthemachineryshallbeprotected machineformaintenancepurposeeitherfrom asfarasitisreasonably practicablefromdust.harmful cartoporotherwise. fumes andhumidity. 4.5.2.2 Dimensionsofworking areasinsidethe well 45.2.5Lighting andsocket outlets a} The dimensions ofworking areas inside the The working area and machinery spaces shall be wellshallbesufficienttopermiteasyandsafe provided with permanently installed electric lighting working on equipment, especially the onthe basisofatleast 200 luxatfloor level. electricalequipment. 4.5.2.6 Handling ofequipment I} A clear horizontal area in front of the control panelsandthecabinets.Thisarea One or more metal supports or hooks with the isdefined asfollows: indicationofthesafe working load,asappropriate, are i} Depth, measured from the external provided in the machinery spaces, conveniently surface of the enclosures, at least positioned topermit thehoisting ofheavyequipment. 0.70 m;and 4.5.3Machinery Outside oftheWell ii} Width, the greater of the following values :0.50 mor the full width of 4.5.3.1 Generalprovisions thecabinetorpanel. Machinery spaces outside of the well shall be so 2} Aclearhorizontalareaofatleast0.50 m constructed towithstand theloadsandforcestowhich x0.60 mformaintenanceandinspec tion theyareintendedtobesubjected. of moving parts at points where this is 3 IS15785:2007 4.5.3.2Machinery cabinet ofminimum0.50m x 0.60 m withaminimumheight of 2 m, shall be available for emergency and tests a) The machinery shall be located inside a operations. cabinet;and 4.5.4.5 Control panel b) The machinery cabinet shall consist of imperforate walls, floor. roof and lockable a) Thecontrolpanelshouldbeinstallednearthe door(s). hoistingequipmenteither inside the shaftor outside; 4.5.3.3 Workingarea b) Thecontrol panel should be accessiblefrom Theworkingareainfront ofamachinerycabinetshall the landing for maintenance purposes; complywith therequirementsaccordingto4.5.2.2. c) Adequatesafetymeasuresshouldbeprovided 4.5.3.4Ventilation tocontrol unauthorizedaccess; The,machinerycabinetshallbe suitablyventilated.It d) Adequateilluminationshouldbeprovidedfor shall besuch that the machineryisprotectedasfar as the control panel for easy maintenance. itisreasonably practicablefrom dust. harmful fumes Illumination should be available even when and humidity. . thereisno powersupply.Minimumof50lux illumination should be provided for the 4.5.3.5 Lightingandsocket outlets control panel;and The inside ofthemachinerycabinetshallbeprovided e) Therequirementsspecifiedin IS 14665 (Part withpermanentlyinstalledelectriclightingonthebasis 4/Sec9) shallgenerally apply. ofat least 200 luxat floor level. 4.5.5 Over SpeedGovernor(OSG) The switch placed inside close to the door(s), at an The overspeed governor should be installed without appropriateheight, shallcontrollightingofthecabinet. hindrance tothe movementofthecar. 4.5.4DevicesforEmergency and Tests For maintenance purposes the over speed governor 4.5.4.1 In the case ofmachinery inside the well, the should be accessible from the cartop or otherwise. necessary devices for emergency and tests shall be providedon a panel(s)suitablefor carryingout from 5OPERATINGAND SAFETYDEVICES outsideofthe well all emergency operationsand any 5.1 EmergencyOperation necessarydynamictests ofthelift.Thesedevicesshall beinaccessibleto unauthorizedpersons. 5.1.1 Ifthe manual effort required to move the car in theupwarddirectionwith itsratedloaddoesnotexceed If the emergency and tests devices are not protected 400 N the machine shall be provided with a manual insideamachinerycabinet.theyshallbeenclosedwith meansofemergency operation allowing the car tobe asuitablelockablecover. moved to a landing. If the means for moving the car 4.5.4.2The panel(s)shall, can be driven by the lift moving. then it shall be a smooth.spokeless wheel. a) includethe emergencyoperationdevices; 5.1.2 Ifthe means is removable. it shall be locatedin b) haveequipmentwhichenablesdynamictests an easily accessible place in the machinery space. It tobecarriedout; and shallbesuitablymarkedifthereisanyriskofconfusion c) be provided with an opening for a direct as to the machine for which it is intended. observationoftheliftmachineorwithdisplay devices, which informabout: If the meansis removableor can be disengaged from I) Direction ofmovements; themachine,anelectricsafetydeviceshall beactuated, 2) Reaching ofan unlocking zone; and at the latest when the means is coupled with the machine. 3) Speedofthelift,exceptitisautomatically limited up to0.63 mls. 5.1.3 It shall be possible to check easily whether the 4.5.4.3 The panel(s) shall be lit by a permanently carisinan unlocking zone.Thischeckmay be made, installedelectriclightingon thebasisofatleast50lux for example,by meansofmarkson the suspensionor on the level ofthe panel(s). governorropes(see also 4.5.4.2). Aswitchplacedinsideorclosetothepanel shallcontrol 5.1.4Iftheeffortdefinedin5.1.1isgreaterthan400N. lightingofthe panel(s). a means of electrical emergency operation shall be provided inaccordance with 5.2. 4.5.4.4 Infront ofthe panel(s)afree horizontalarea 4

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.