Preview Installing the ONS 15454 M12 (ANSI and ETSI) Shelf

Installing the ONS 15454 M12 (ANSI and ETSI) Shelf ThischapterexplainshowtoinstalltheONS15454(ANSIandETSI)shelf. Note Unlessotherwisespecified,“ONS15454”referstobothANSIandETSIM12shelfassemblies. Note Duetomemorylimitations,TCC2/TCC2Pcardsarenotsupportedasthenodecontrollerinmulti-shelf configurationfromR10.5.2.6.Hence,itisrecommendedtouseTCC3cardasthenodecontrollerinmulti-shelf configuration.TheTCC2Pcardcanbeusedasacontrolcardinasubtendedshelfwherethenodecontroller isTCC3cardonONS15454chassisorTNC/TNCE/TNCS/TNCS-OcardsonONS15454M6orNCS20015 chassis.TheTCC2Pcardcanalsobeusedasanodecontrollerinastand-aloneconfiguration. •ONS15454ANSIRackInstallation,onpage2 •ONS15454ETSIRackInstallation,onpage5 •NTP-G306InstalltheONS15454Shelf,onpage9 •FrontDoor,onpage23 •ONS15454ANSIBackplaneCovers,onpage31 •NTP-G3OpenandRemovetheFrontDoor,onpage34 •NTP-G4OpenandRemovetheFMECCover(ETSIOnly),onpage38 •NTP-G5RemovetheBackplaneCovers(ANSIOnly),onpage41 •ONS15454ETSIFrontMountElectricalConnection,onpage43 •NTP-G6InstalltheMIC-A/PandMIC-T/C/PFMECs(ETSIOnly),onpage43 •PowerandGroundDescription,onpage45 •NTP-G7InstallthePowerandGround,onpage45 •ShelfVoltageandTemperature,onpage53 •NTP-G230ViewShelfVoltageandTemperature,onpage54 •Fan-TrayAssembly,onpage54 •NTP-G8InstalltheFan-TrayAssembly,onpage60 •ONS15454ANSIAlarmExpansionPanel,onpage63 •NTP-G9InstalltheAlarmExpansionPanel(ANSIOnly),onpage69 •ONS15454ANSIAlarm,Timing,LAN,andCraftPinConnections,onpage72 InstallingtheONS15454M12(ANSIandETSI)Shelf 1 InstallingtheONS15454M12(ANSIandETSI)Shelf ONS15454ANSIRackInstallation •NTP-G10AttachWirestoAlarm,Timing,LAN,andCraftPinConnections,onpage78 •NTP-G11InstallanExternalWire-WrapPanelontheAEP(ANSIOnly),onpage90 •NTP-G12InstallandClosetheFMECCover(ETSIOnly),onpage95 •NTP-G13InstalltheRearCover(ANSIOnly),onpage96 •TypicalDWDMRackLayouts,onpage98 •NTP-G14InstallDWDMEquipment,onpage101 •MultishelfManagement,onpage115 •NTP-G301ConnecttheONS15454MultishelfNodeandSubtendingShelvestoanMS-ISC-100TCard, onpage116 •NTP-G304ConfiguretheMS-ISC-100TCardforaONS15454MultishelfNodeforNon-DefaultPublic andPrivateVLANIDs,onpage119 •NTP-G307PerformtheONS15454ShelfInstallationAcceptanceTest,onpage121 •NTP-G295ConnecttheONS15454MultishelfNodeandSubtendingShelvestoaCatalyst2950or Catalyst3560,onpage124 •NTP-G296UpgradetheONS15454MultishelfwithMS-ISCCardConfigurationUsingtheCatalyst 3560,onpage126 •NTP-G297UpgradetheONS15454MultishelfwithCatalyst2950ConfigurationUsingtheCatalyst 3560,onpage128 •NTP-G298ConfigureaCiscoCatalyst2950orCatalyst3560(ActiveandStandby)foraONS15454 MultishelfNode,onpage130 •EthernetAdapterPanel,onpage132 •FillerandBlankCards,onpage134 •CableRoutingandManagement,onpage135 ONS 15454 ANSI Rack Installation TheONS15454ANSIshelfismountedina19-or23-in.(482.6-or584.2-mm)equipmentrack.Theshelf projectsfiveinches(127mm)fromthefrontoftherack.ItmountsinbothElectronicIndustriesAlliance (EIA)standardandTelcordia-standardracks.Theshelfisatotalof17inches(431.8mm)widewithno mountingearsattached.RingrunsarenotprovidedbyCiscoandmighthinderside-by-sideinstallationof shelveswherespaceislimited. TheONS15454ANSIassemblymeasures18.5inches(469.9mm)high,19or23inches(482.6or584.2mm) wide(dependingonwhichwaythemountingearsareattached),and12inches(304.8mm)deep.Youcan installuptofourONS15454ANSIsinaseven-foot(2133.6mm)equipmentrack.TheONS15454ANSI musthaveoneinch(25.4mm)ofairspacebelowtheinstalledshelftoallowairflowtothefanintake.Ifa secondONS15454ANSIisinstalledunderneaththeshelf,theairrampontopofthelowershelfprovidesthe airspacingneededandshouldnotbemodifiedinanyway.Thefollowingfigureshowsthedimensionsofthe ONS15454ANSI. Note A10-Gbps-compatibleshelf(15454-SA-ANSIor15454-SA-HD)andfan-trayassembly(15454-FTA3, 15454-FTA3-T,or15454-CC-FTA)arerequiredifONS15454ANSI10-GbpsCross-Connect(XC10G)cards areinstalledintheshelf. InstallingtheONS15454M12(ANSIandETSI)Shelf 2 InstallingtheONS15454M12(ANSIandETSI)Shelf ReversibleMountingBracket Figure1:ONS15454ANSIShelfDimensions Reversible Mounting Bracket Caution UseonlythefasteninghardwareprovidedwiththeONS15454ANSIshelftopreventloosening,deterioration, andelectromechanicalcorrosionofthehardwareandjoinedmaterial. Caution WhenmountingtheONS15454ANSIshelfinaframewithanonconductivecoating(suchaspaint,lacquer, orenamel)eitherusethethread-formingscrewsprovidedwiththeONS15454ANSIshippingkit,orremove thecoatingfromthethreadstoensureelectricalcontinuity. Theshelfcomespresetforinstallationina23-inch(584.2mm)rack,butyoucanreversethemountingbracket tofitthesmaller19-inch(482.6mm)rack. InstallingtheONS15454M12(ANSIandETSI)Shelf 3 InstallingtheONS15454M12(ANSIandETSI)Shelf MountingaSingleNode Mounting a Single Node MountingtheONS15454ANSIshelfinarackrequiresaminimumof18.5inches(469.9mm)ofvertical rackspaceandoneadditionalinch(25.4mm)forairflow.Toensurethemountingissecure,usetwotofour #12-24mountingscrewsforeachsideoftheshelf.Thefollowingfigureshowstherackmountingposition fortheONS15454ANSIshelf. Figure2:MountinganONS15454ANSIShelfinaRack Twopeopleshouldinstalltheshelf;however,onepersoncaninstallitusingthetemporarysetscrewsincluded. Theshelfshouldbeemptyforeasierlifting.Thefrontdoorcanalsoberemovedtolightentheshelf. Mounting Multiple Nodes Moststandard(TelcordiaGR-63-CORE,19-inch[482.6-mm]or23-inch[584.2-mm])seven-foot(2.133-m) rackscanholdfourONS15454ANSIshelvesandafuseandalarmpanel.However,unequalflangeracksare limitedtothreeONS15454ANSIshelvesandafuseandalarmpanel,orfourONS15454ANSIshelvesusing afuseandalarmpanelfromanadjacentrack. Ifyouareusingtheexternal(bottom)bracketstoinstallthefan-trayairfilter,youcaninstallthreeshelf assembliesinastandardseven-foot(2.133-m)rack.Ifyouarenotusingtheexternal(bottom)brackets,you caninstallfourshelfassembliesinarack.Theadvantageofusingthebottombracketsisthatyoucanreplace thefilterwithoutremovingthefan-tray. ONS 15454 ANSI Bay Assembly TheCiscoONS15454ANSIbayassemblysimplifiesorderingandinstallingtheONS15454ANSIshelf becauseitallowsyoutoordershelfassembliespreinstalledinaseven-foot(2,133mm)rack.Thebayassembly InstallingtheONS15454M12(ANSIandETSI)Shelf 4 InstallingtheONS15454M12(ANSIandETSI)Shelf ONS15454ETSIRackInstallation isavailableinathree-orfour-shelfconfiguration.Thethree-shelfconfigurationincludesthreeONS15454 ANSIshelfassemblies,aprewiredfuseandalarmpanel,andtwofiber-storagetrays.Thefour-shelf configurationincludesfourONS15454ANSIshelfassembliesandaprewiredfuseandalarmpanel.Youcan orderoptionalfiberchannelswitheitherconfiguration.InstallationproceduresareincludedintheUnpacking andInstallingtheCiscoONS15454Four-ShelfandZero-ShelfBayAssemblydocumentthatshipswiththe bayassembly. ONS 15454 ETSI Rack Installation TheONS15454ETSIshelf(15454-SA-ETSI)ismountedina600x600-mm(23-inch)or600x300-mm (11.8-inch)equipmentcabinet/rack.Theshelfprojects240mm(9.45inches)fromthefrontoftherack.It mountsinETSI-standardracks.Theshelfisatotalof435mm(17.35inches)widewithnomountingears attached.RingrunsarenotprovidedbyCiscoandmighthinderside-by-sideinstallationofshelveswhere spaceislimited. TheONS15454ETSIshelfmeasures616.5mm(24.27inches)high,535mm(21.06inches)wide,and280 mm(11.02inches)deep.YoucaninstalluptothreeONS15454ETSIshelvesinaseven-foot(2133.6mm) equipmentrack.TheONS15454ETSImusthaveoneinch(25.4mm)ofairspacebelowtheinstalledshelf toallowairflowtothefanintake.IfasecondONS15454ETSIisinstalledbelowthefirstshelf,anETSIair rampunitmustbeassembledbetweenthetwoshelvestoensureadequateairflow. ThefollowingfigureprovidesthedimensionsoftheONS15454ETSIshelf. Caution ThestandardETSIrackscanholdthreeONS15454ETSIshelfassembliesandtwoairramps.Whenmounting ashelfinapartiallyfilledrack,loadtherackfromthebottomtothetopwiththeheaviestcomponentatthe bottomoftherack.Iftherackisprovidedwithstabilizingdevices,installthestabilizersbeforemountingor servicingtheunitintherack. Caution TheONS15454ETSImusthave1inch(25.4mm)ofairspacebelowtheinstalledshelftoallowairflowto thefanintake.Theairramp(theangledpieceofsheetmetalontopoftheshelf)providesthisspacingand shouldnotbemodifiedinanyway. InstallingtheONS15454M12(ANSIandETSI)Shelf 5 InstallingtheONS15454M12(ANSIandETSI)Shelf MountingaSingleNode Figure3:ONS15454ETSIShelfDimensions Mounting a Single Node TheONS15454ETSIrequires616.5mm(24.24inch)minimumofverticalrackspaceand25mm(1inch) belowtheinstalledshelftoallowairflowtothefanintake.IfasecondONS15454ETSIisinstalledabove ashelf,theairrampbetweentheshelvesprovidesspaceforairflow.Toensurethemountingissecure,use twotofourM6mountingscrewsforeachsideoftheshelf.Ashelfshouldbemountedatthebottomofthe rackifitistheonlyunitintherack. ThefollowingfigureshowstherackmountingpositionfortheONS15454ETSIshelf. InstallingtheONS15454M12(ANSIandETSI)Shelf 6 InstallingtheONS15454M12(ANSIandETSI)Shelf MountingMultipleNodes Figure4:MountinganONS15454ETSIShelfinaRack Twopeopleshouldinstalltheshelf;however,onepersoncaninstallitusingthetemporarysetscrewsincluded. Theshelfshouldbeemptyforeasierlifting.Thefrontdoorcanalsoberemovedtolightentheshelf. Mounting Multiple Nodes Moststandard(TelcordiaGR-63-CORE,23-inch[584.2mm])seven-foot(2,133mm)rackscanholdthree ONS15454ETSIshelves,twoairramps,andafuseandalarmpanel.Thefollowingfigureshowsathree-shelf ONS15454ETSIbayassembly. InstallingtheONS15454M12(ANSIandETSI)Shelf 7 InstallingtheONS15454M12(ANSIandETSI)Shelf MountingMultipleNodes Figure5:Three-ShelfONS15454ETSIBayAssembly Warning Stabilityhazard.Therackstabilizingmechanismmustbeinplace,ortherackmustbeboltedtothe floorbeforeyouslidetheunitoutforservicing.Failuretostabilizetherackcancausetheracktotip over.Statement1048 Warning Thisproductrequiresshort-circuit(overcurrent)protection,tobeprovidedaspartofthebuilding installation.Installonlyinaccordancewithnationalandlocalwiringregulations.Statement1045 Warning Thisproductreliesonthebuilding'sinstallationforshort-circuit(overcurrent)protection.Ensurethat theprotectivedeviceisratednotgreaterthan:10A-20A,100-240VAC~.Statement1005 Warning Topreventthesystemfromoverheating,donotoperateitinanareathatexceedsthemaximum recommendedambienttemperatureof:45degreesC(113degreesF).Statement1047 Warning Takecarewhenconnectingunitstothesupplycircuitsothatwiringisnotoverloaded.Statement1018 InstallingtheONS15454M12(ANSIandETSI)Shelf 8 InstallingtheONS15454M12(ANSIandETSI)Shelf NTP-G306InstalltheONS15454Shelf Warning Iftherackisprovidedwithstabilizingdevices,installthestabilizersbeforemountingorservicingthe unitintherack.Statement1006 Warning Topreventbodilyinjurywhenmountingorservicingthisunitinarack,youmusttakespecialprecautionsto ensurethatthesystemremainsstable.Thefollowingguidelinesareprovidedtoensureyoursafety: •Thisunitshouldbemountedatthebottomoftherackifitistheonlyunitintherack. •Whenmountingthisunitinapartiallyfilledrack,loadtherackfromthebottomtothetopwith theheaviestcomponentatthebottomoftherack. •Iftherackisprovidedwithstabilizingdevices,installthestabilizersbeforemountingorservicing theunitintherack.Statement1006 Warning Topreventairflowrestriction,allowclearancearoundtheventilationopeningstobeatleast:1inch (25.4mm)Statement1076 Warning TheONS15454musthave1inch(25.4mm)ofairspacebelowtheinstalledshelfassemblytoallowair flowtothefanintake.Theairramp(theangledpieceofsheetmetalontopoftheshelfassembly) providesthisspacingandshouldnotbemodifiedinanyway.Statement385 Warning VoltagesthatpresentashockhazardmayexistonPoweroverEthernet(PoE)circuitsifinterconnections aremadeusinguninsulatedexposedmetalcontacts,conductors,orterminals.Avoidusingsuch interconnectionmethods,unlesstheexposedmetalpartsarelocatedwithinarestrictedaccesslocation andusersandservicepeoplewhoareauthorizedwithintherestrictedaccesslocationaremadeaware ofthehazard.Arestrictedaccessareacanbeaccessedonlythroughtheuseofaspecialtool,lockand keyorothermeansofsecurity.Statement1072 NTP-G306 Install the ONS 15454 Shelf Purpose Thisprocedurereversesthemountingbracketandmountsshelfassembliesina rack. InstallingtheONS15454M12(ANSIandETSI)Shelf 9 InstallingtheONS15454M12(ANSIandETSI)Shelf NTP-G306InstalltheONS15454Shelf Tools/Equipment #2PhillipsDynamometricscrewdriver Mediumslot-headscrewdriver Smallslot-headscrewdriver Pinnedhexkey ETSIonly: •TwoM6x20socketsetscrews •EightM6x20pan-headPhillipsmountingscrews ANSIonly: •Two#12-24x3/4setscrews(48-1003-XX) •Eight#12-24x3/4pan-headPhillipsmountingscrews(48-1004-XX, 48-1007-XX) PrerequisiteProcedures NTP-G305UnpackandInspecttheONS15454,ONS15454M2,andONS15454 M6Shelves Required/AsNeeded Required Onsite/Remote Onsite SecurityLevel None Note Theshelf,theairramp,andtheE1-75/120conversionpanelshipwiththeETSImountingbracketsinstalled asneededforinstallationinanETSIrack.Ifyouwanttoinstallthenodeina19-inch(482.6-mm)rack,the ETSImountingbracketsoftheshelfandtheairrampneedtobereplacedwiththe19-inch(482.6-mm) mountingbracketsthatshippedintheshipkit. Procedure Step1 (ANSIshelvesonly)CompletetheDLP-G3ReversetheMountingBrackettoFita19-inch(482.6-mm)Rack (ANSIOnly),onpage11ifyouneedtoconvertfroma23-inch(584.2mm)toa19-inch(482.6mm)rack. Step2 (ANSIshelvesonly)Toinstalltheairfilteronthebottomoftheshelfratherthanbelowthefan-trayassembly, completetheDLP-G4InstalltheExternalBracketsandAirFilter(ANSIOnly),onpage12. Step3 Completethenecessaryrackmounttaskasapplicable: •DLP-G678MounttheONS15454ShelfinaRack(OnePerson),onpage14 •DLP-G679MounttheONS15454ShelfinaRack(TwoPeople),onpage15 •DLP-G680MountMultipleONS15454ShelfAssembliesinaRack,onpage17 •DLP-G8InstalltheAirRamp,onpage20 Step4 ContinuewiththeNTP-G3OpenandRemovetheFrontDoor,onpage34. InstallingtheONS15454M12(ANSIandETSI)Shelf 10

Description:
Cisco ONS 15454 Hardware Installation Guide -Installing the ONS 15454 M12 (ANSI and ETSI) Shelf. NTP-G10 Attach Wires to Alarm, Timing, LAN, and Craft Pin Connections , page 85 NTP-G301 Connect the ONS 15454 Multishelf Node and Subtending Shelves to an MS-ISC-100T Card,.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.