ebook img

Installation Guide - ALC Lighting Controls PDF

62 Pages·2011·5.36 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Installation Guide - ALC Lighting Controls

Installation Guide Spectrum System Dual Fix Pluggable Lighting Control Module 358 61 250 35 66 45/46 Fixing Size Maximum M8 300 320 No.14 1/2 Turn Fixing Mains Comms Output Connector Wiring Order Code: AX-OPGST18 Alternative: Wieland 34.362.0211.1 Switched Live Earth Neutral Maintained Live Dimming 0V L Dimming Line E Input Connector Wiring N OAlrtdeernr aCtiovdee: :R ASX 1-I8P9B-6L0432 0V In2/Off/LS In1/On/PD +V For Switches requiring 2 wires connect between 0V & Off For Switches requiring 3 wires connect between 0V,On & Off P1 AXPL98ATDH Document AID1001 Iss 3 SCN - + N L1 N L1 Installation Guide Spectrum System Dual Fix Pluggable Lighting Control Module LCM Installation 1/2 Turn Fixing Pluggable Sensors Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com 20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796 Watford, Herts, WD18 8JA, UK. Email: Installation Guide Spectrum System Single Fix Pluggable Lighting Control Module 288 270 Fixing Size Maximum M6 248 179 No.14 Pluggable Sensors Output to Modular Input from Modular Wiring Infrastructure Wiring Infrastructure Output Connector Wiring Input Connector Wiring Order Code: AX-OPGST18 Order Code: AX-IPBL4 Alternative: Wieland 34.362.0211.1 Alternative: RS 189-6032 Switched Live 0V Earth In2/Off/LS Neutral In1/On/PD Maintained Live +V Dimming 0V Dimming Line For Switches requiring 2 wires connect between 0V & Off For Switches requiring 3 wires connect between 0V,On & Off Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com 20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796 Watford, Herts, WD18 8JA, UK. Email: Installation Guide Spectrum System Hard Wired Lighting Control Module Mechanical Fixing 61 380 32 320 Fixing Size Maximum M8 300 335 No.14 30 62 Preferred Cabling Positions for Mains, Input and Communications Wiring Mains Mains Input/Output Input/Output and Looping EARTH NEUTRAL LIVE and Looping B A SPARE OUTPUT 1 Eme Orugtepnuctsy Test OUTPUT 2 OUTPUT 3 Commu Bnuiscations OUTPUT 4 Override Override Inputs Inputs P1 AXHW48ATDH Document AID1003 Iss 5 Installation Guide Spectrum System Hard Wired Lighting Control Module Wiring Output Connector Wiring Input Connector Wiring Live In 0V Live In In2/Off/LS Fused Live Out (Un-switched) In1/On/PD Fused Live Out (Switched) +V Dimming 0V (See Note) For Switches requiring 2 wires connect between 0V & Off Dimming Line For Switches requiring 3 wires connect between 0V,On & Off Four additional Inputs are available using Plug In RJ12 Connectors/Leads. Care should be taken not to damage the leads Note: when replacing the enclosure lid. The dimming 0V is internally connected between each output connector. Output Configurations Example allows for 4 separate Live feeds giving a Example allows for a single Live feed giving a maximum load per Output of 8 Amps maximum load between all four Outputs of 16 Amps (Note: Single Phase Only) (Note: Maximum Load on any 1 output is 8 Amps) Live Feeds Live In Live In Live Out Live Out Loop Terminal Facility NOT used LIVE LIVE FUSE FUSE Live In 1 Live Out 1 Live Out 1 RELAY CONTACT RELAY CONTACT FUSE FUSE Live In 2 Live Out 2 Live Out 2 RELAY CONTACT RELAY CONTACT FUSE FUSE Live In 3 Live Out 3 Live Out 3 RELAY CONTACT RELAY CONTACT FUSE FUSE Live In 4 Live Out 4 Live Out 4 RELAY CONTACT RELAY CONTACT Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com 20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796 Watford, Herts, WD18 8JA, UK. Email: Installation Guide Spectrum System Din Rail Lighting Control Module P1 AXDN22ATDH Document AID1004 Iss 4 Installation Guide Spectrum System Din Rail Lighting Control Module Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com 20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796 Watford, Herts, WD18 8JA, UK. Email: Installation Guide Spectrum System Input Module Mechanical Fixing Black Tab C - + SEN8SOR SEN7SOR SEN6SOR SEN5SOR SEN4SOR SEN3SOR SEN2SOR SEN1SOR STATUS LED POWER LED COMMS LED 0V 2 1 2 1 2 1 +V +V 0V 0V 2 1 2 1 2 1 2 1 White Tabs Din Rail Fixing 160 C - + SEN8SOR SEN7SOR SEN6SOR SEN5SOR SEN4SOR SEN3SOR SEN2SOR SEN1SOR 90 STATUS LED 100 POWER LED COMMS LED 0V 2 1 2 1 2 1 +V +V 0V 0V 2 1 2 1 2 1 2 1 Fixing Size (3 Per LCM) Panel Mounting 114 Maximum M3.5/No.6 Adaptable Box 350 85 30 200 140 20 310 Fixing Size (4 Per Box) Maximum M4/No.10 P1 AXDN08SH Document AID1005 Iss 4 Installation Guide Spectrum System Input Module Wiring Pluggable Sensors Inputs Wiring Order +V 0V 2/Off/LS 1/On/PD For Switches requiring 2 wires connect between 0V & Off For Switches requiring 3 wires connect between 0V,On & Off Note: Wireable Inputs and Sensor Inputs are connected internally e.g. Wireable Input 1 is connected to Sensor Input 1. This means that only a combination up to 8 different numbered Inputs can be used either Wireable or Sensor. An exception to this would be if two Input devices were required to control the same output e.g. two Presence Detectors in one room. Cooper Controls Ltd Tel: +44 (0)1923 495495 www.coopercontrol.com 20 Greenhill Crescent, Watford Business Park, Fax: +44 (0)1923 228796 Watford, Herts, WD18 8JA, UK. Email:

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.