ebook img

DTIC ADA506679: Demonstration and Validation of a Regenerated-Cellulose Dialysis Membrane Diffusion Sampler for Monitoring Ground Water Quality and Remediation Progress at DoD Sites PDF

0.95 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview DTIC ADA506679: Demonstration and Validation of a Regenerated-Cellulose Dialysis Membrane Diffusion Sampler for Monitoring Ground Water Quality and Remediation Progress at DoD Sites

ENGINEERING SERVICE CENTER Port Hueneme, California 93043-4370 T R ECHNICAL EPORT TR-2280-ENV Protocol Report DEMONSTRATION AND VALIDATION OF A REGENERATED CELLULOSE DIALYSIS MEMBRANE DIFFUSION SAMPLER FOR MONITORING GROUND WATER QUALITY AND REMEDIATION PROGRESS AT DoD SITES (ER-0313) by Thomas E. Imbrigiotta, U.S. Geological Survey, Trenton, New Jersey Joseph S. Trotsky, Naval Facilities Engineering Service Center, Port Hueneme, California Matthew C. Place, Battelle, Columbus, Ohio January 2007 Approved for public release; distribution is unlimited. Printed on recycled paper Form Approved REPORT DOCUMENTATION PAGE OMB No. 0704-0811 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information, it if does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From – To) JANUARY 2007 TECHNICAL REPORT - FINAL 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER PROTOCOL REPORT DEMONSTRATION AND VALIDATION OF A REGENERATED 5b. GRANT NUMBER CELLULOSE DIALYSIS MEMBRANE DIFFUSION SAMPLER FOR MONITORING GROUND WATER QUALITY AND 5c. PROGRAM ELEMENT NUMBER REMEDIATION PROGRESS AT DOD SITES (ER-0313) 6. AUTHOR(S) 5d. PROJECT NUMBER Thomas E. Imbrigiotta, U.S. Geological Survey, Trenton, NJ Joseph S. Trotsky, Naval Facilities Engineering Service Center, 5e. TASK NUMBER Port Hueneme, California 5f. WORK UNIT NUMBER Matthew C. Place, Battelle, Columbus, Ohio 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESSES 8. PERFORMING ORGANIZATION REPORT NUMBER Commanding Officer US Geological Survey TR-2280-ENV Naval Facilities Engineering Service Center 810 Bear Tavern Road, 1100 23rd Ave Suite 206 Port Hueneme, CA 93043-4370 West Trenton, NJ 08628 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITORS ACRONYM(S) Environmental Security Technology Certification Program ESTCP 901 North Stuart Street, Suite 303 Arlington, VA 22203 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution is unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT This protocol report provides guidance and procedures for successfully using regenerated cellulose dialysis membrane samplers (dialysis samplers). Development of the protocol was funded under project ER-0313 by the Environmental Security Technology Certification Program (ESTCP). The objectives of this protocol report or user’s guide are (1) to discuss the principle of operation of membrane diffusion samplers, (2) to present the basic design and steps in construction of dialysis samplers, (3) to discuss the considerations that must be taken into account before deciding to use a dialysis sampler, (4) to present the steps that must be taken in properly deploying, retrieving, and sampling a dialysis sampler, (5) to discuss the interpretation of field results obtained with dialysis samplers compared to other sampling methodologies, and to discuss how results may vary depending on the hydrologic and chemical variation over a well screen or open interval, and (6) to discuss quality assurance/quality control (QA/QC) samples that should be collected when using dialysis samplers. This report is primarily concerned with the use of dialysis samplers for collection of ground-water samples from wells, but also discusses briefly the use of dialysis samplers for collection of pore water samples from stream or lake sediments. Findings from a number of recent field comparison case studies in which regenerated cellulose dialysis membrane sampler results are compared to other sampling techniques are reviewed. 15. SUBJECT TERMS Environmental Security Technology Certification Program (ESTCP); regenerated cellulose dialysis membrane samplers; dialysis samplers; protocol; diffusion sampling; ER-0313 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF 18. NUMBER OF 19a. NAME OF RESPONSIBLE PERSON a. REPORT b. ABSTRACT c. THIS PAGE ABSTRACT PAGES U U U 19b. TELEPHONE NUMBER (include area code) Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 Protocol for Use of Regenerated-Cellulose Dialysis Membrane Diffusion Samplers for ESTCP Project ER-0313, Demonstration and Validation of a Regenerated-Cellulose Dialysis Membrane Diffusion Sampler for Monitoring Ground Water Quality and Remediation Progress at DoD Sites by Thomas E. Imbrigiotta U.S. Geological Survey 810 Bear Tavern Road, Suite 206 West Trenton, NJ 08628 Joseph S. Trotsky Naval Facilities Engineering Service Center 1100 23rd Avenue Port Hueneme, CA 93043-4370 Matthew C. Place Battelle 505 King Avenue Columbus, OH 43201 February 6, 2007 CONTENTS Abbreviations and Acronyms.....................................................................................................iv Acknowledgements.......................................................................................................................v Executive Summary.....................................................................................................................vi 1.0 Introduction.............................................................................................................................1 1.1 Diffusion Principle................................................................................................................1 1.2 Background of Dialysis Sampler Development....................................................................3 2.0 Sampler Design and Construction.........................................................................................6 2.1 Basic Sampler Design...........................................................................................................6 2.2 Regenerated-Cellulose Dialysis Membrane Availability......................................................6 2.3 Sampler Construction............................................................................................................7 2.4 Sampler Assembly.................................................................................................................8 2.5 Sampler Storage Prior to Deployment................................................................................10 2.6 Filling Samplers for Anoxic Wells......................................................................................11 2.7 Suspension Line..................................................................................................................11 3.0 Considerations Prior to Use of Dialysis Samplers.............................................................12 3.1 Use and Application of Dialysis Samplers..........................................................................12 3.2 Trips to the Field.................................................................................................................12 3.3 Well Construction...............................................................................................................12 3.4 Deployment Depth and Vertical Profiling..........................................................................13 3.5 Sampler Volume and Length...............................................................................................14 3.6 Analyte Permeability and Equilibration Times...................................................................15 3.7 Biodegradation of Dialysis Membrane...............................................................................15 3.8 Volume Loss Due to Dialysis Process................................................................................17 4.0 Sampler Deployment, Recovery, Sample Collection.........................................................19 4.1 Transporting Samplers to the Field.....................................................................................19 4.2 Initial Well Measurements..................................................................................................19 4.3 Installation...........................................................................................................................19 4.4 Deployment Period..............................................................................................................19 4.5 Sampler Recovery and Sample Collection..........................................................................20 4.6 Disposal and Decontamination............................................................................................20 5.0 Data Interpretation...............................................................................................................21 5.1 Tools Used in Data Comparisons........................................................................................21 5.2 Field Comparison Case Studies...........................................................................................24 5.3 Potential Reasons for Differences Between Field Comparison Results.............................28 5.3.1 Field Comparison Test Design.....................................................................................28 5.3.2 Well Construction.........................................................................................................28 5.3.3 Sampling Mechanisms..................................................................................................29 5.3.4 Acceptance Criteria......................................................................................................29 5.3.5 Chemical Stratification and Hydraulic Heterogeneity..................................................29 6.0 Quality Assurance and Quality Control.............................................................................31 6.1 Quality Assurance/Quality Control Samples......................................................................31 6.2 Potential Sources of Variation Between Replicate Samplers..............................................31 6.2.1 Construction Materials.................................................................................................31 ii 6.2.2 Handling and Storage...................................................................................................32 6.2.3 Deployment and Sampling...........................................................................................32 7.0 Summary................................................................................................................................33 7.1 Situational Use of Dialysis Samplers..................................................................................35 7.2 Approved Regulatory Use of Dialysis Samplers.................................................................33 7.3 Conclusions.........................................................................................................................33 8.0 References Cited....................................................................................................................36 FIGURES Figure 1-1. Diffusion Across a Membrane (Fick’s Law of Diffusion) (Modified from ITRC, 2002)....................................................................................................................................2 Figure 2-1. Regenerated-Cellulose Dialysis Membrane Sampler (2.5 inches in diameter by 24 inches long)..........................................................................................................................6 Figure 2-2. Component Parts of a Regenerated-Cellulose Dialysis Membrane Sampler Before Assembly..............................................................................................................................8 Figure 2-3. Partially Assembled Regenerated Cellulose Dialysis Membrane Sampler Before Filling with Deionized Water with External Supports Installed in the Protective Mesh ...9 Figure 2-4. Fully Assembled Regenerated-Cellulose Dialysis Membrane Sampler with Supports External to the Dialysis Membrane (2.5 inches in diameter by 15 inches long).................9 Figure 2-5. Regenerated-Cellulose Dialysis Membrane Sampler with Rigid Internal Support Made of (a) Perforated PVC and (b) LDPE Mesh.............................................................10 Figure 2-6. Example of a Dialysis Sampler with a Plastic-Coated Stainless-Steel Suspension Line (2.5 inches in diameter by 36 inches long)................................................................11 Figure 5-1. Example of a 1:1 Correspondence Plot of Dialysis Sampler vs. Low-Flow Purging Results for Manganese (from Imbrigiotta et al., 2007) (LRL, lower reporting limit; 1/2MDL, one half minimum detection limit; μg/L, micrograms per liter)........................22 Figure 5-2. Example of a 1:1 Correspondence Plot of Dialysis Sampler vs. Low-Flow Purging Results for Chloride (from Imbrigiotta et al., 2007) (LRL, lower reporting limit; 1/2MDL, one half minimum detection limit; mg/L, milligrams per liter).........................................22 TABLES Table 1-1. Dialysis Sampler Advantages and Limitations.............................................................5 Table 2-1. Dialysis Membrane Widths, Filled Diameters, and Filled Volumes............................7 Table 3-1. Analytes Tested in the Laboratory for Permeability and Equilibration Times Through Regenerated-Cellulose Dialysis Membranes.....................................................................16 Table 5-1. Water-Quality Parameters Tested in Field Comparison Studies................................27 iii ABBREVIATIONS AND ACRONYMS BTEX Benzene, toluene, ethylbenzene, and xylenes COC Contaminant of concern DMLS Dialysis multi-level sampler DoD Department of Defense GC-MS Gas chromatography-mass spectrometry HMX Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine ICP-MS Inductively coupled plasma – mass spectrometry LRL Laboratory reporting level LDPE Low-density polyethylene MDL Minimum detection limit MNA Monitored natural attenuation MTBE Methyl tertiary-butyl ether NAES Naval Air Engineering Station NAWC Naval Air Warfare Center NBVC Naval Base Venture County NFESC Naval Facilities Engineering Service Center NTU Nephelometric Turbidity Units PAH Polycyclic aromatic hydrocarbons PCB Polychlorinated biphenyls PDB Polyethylene diffusion bag PVC Polyvinyl chloride QA/QC Quality assurance/quality control RC Regenerated-cellulose RCDM Regenerated-cellulose Dialysis Membrane RDX Hexahydro-1,3,5-trinitro-1,3,5-triazine USEPA U.S. Environmental Protection Agency USGS U.S. Geological Survey VOC Volatile organic compound iv ACKNOWLEDGEMENTS Thomas Imbrigiotta of USGS, Joey Trotsky of NFESC, and Matt Place of Battelle all contributed to the writing of this report. Jeff Dale of the US Navy was instrumental in encouraging and supporting the initial work on dialysis samplers at the NAWC West Trenton, NJ site that eventually led to this demonstration. Theodore Ehlke of USGS and Ron Hoeppel of NFESC were instrumental in conceiving, proposing, and obtaining funding for this project. The authors appreciate the careful review and comments offered on this manuscript by Don Vroblesky and Tim Wilson of USGS. v

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.