ebook img

validação dos métodos de análise por ativação do laboratório de análise por ativação neutrônica ... PDF

261 Pages·2015·5.38 MB·Portuguese
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview validação dos métodos de análise por ativação do laboratório de análise por ativação neutrônica ...

AUTARQUIA ASSOCIADA À UNIVERSIDADE DE SÃO PAULO VALIDAÇÃO DOS MÉTODOS DE ANÁLISE POR ATIVAÇÃO DO LABORATÓRIO DE ANÁLISE POR ATIVAÇÃO NEUTRÔNICA DO IPEN - CNEN/SP VISANDO A PRODUÇÃO DE MATERIAIS DE REFERÊNCIA CERTIFICADOS Robson Petroni Dissertação apresentada como parte dos requisitos para obtenção do Grau de Mestre em Ciências na Área de Tecnologia Nuclear - Aplicações Orientador: Prof. Dr. Edson Gonçalves Moreira São Paulo 22001154 INSTITUTO DE PESQUISAS ENERGÉTICAS E NUCLEARES Autarquia associada à Universidade de São Paulo Validação dos métodos de análise por ativação do laboratório de Análise por Ativação Neutronica do IPEN - CNEN/SP visando a produção de materiais de referência certificados Robson Petroni Dissertação apresentada como parte dos requisitos para obtenção do Grau de Mestre em Ciências na Área de Tecnologia Nuclear - Aplicações Orientador: Prof. Dr. Edson Gonçalves Moreira Versão Corrigida São Paulo 22001154 Dedico aos meus pais, irmãos e familiares Aurora do Mundo**************** Quem teve os amores que tive na vida É gente entendida na mágoa e na dor E sabe por certo que um doce carinho Às vezes é espinho em forma de flor Estando sofrendo aqui na cidade A louca saudade de um certo amor Busquei o remédio pra mente saudosa Na vida gostosa do interior Cruzei os cerrados, chapadas e serras Pro lado das terras de Minas Gerais Vi campos floridos e belos cenários Ouvi os canários nos macaubais Fumaça distante no azul do horizonte Na encosta do monte, formando espirais Vi tudo que amo na tranquilidade Mas minha saudade ainda era mais Passei uma noite no Rancho Amizade E vi na saudade o começo do fim A chuva caía naquele tugúrio Num triste murmúrio por sobre o capim A noite avançava e eu não dormia Agora sabia que amar era assim Por fim entreguei-me ao sono profundo E a aurora do mundo caiu sobre mim Voltei pra cidade, fiquei na agonia Até que um dia meu bem reencontrei Beijei a menina com todo carinho E aquele rostinho acariciei Cantando seguiu-me na linha da vida Na estrada florida que eu lhe mostrei Porque ela sabe que agora é só minha És minha rainha eu sou o seu rei (Goiá) #momentopoetico Tempestade Quando o mais frio dos ventos sul interpola a quente brisa do mar os sentimentos se confundem, histórias são relembradas... O amor a uma pessoa não é medido pelo espaço que ela ocupa em nosso coração. Mas pelo vazio que ela nos deixa, quando está distante. A saudade é como o vento... castiga, destrói, maltrata, ... e passa ... só então o ínfimo mar se acalma. E a quente brisa, enfim volta a soprar! (Robson Petroni) AGRADECIMENTOS Agradeço primeiramente a Deus, por minha saúde, alegria e pelo dom da vida. Agradeço aos meus pais Dona Luzia e Sr. José e aos meus irmãos Rodrigo e Ricardo por todo incentivo e apoio para a realização de mais este projeto. Amo vocês. Agradeço ao grande amigo, incentivador e super-orientador Dr. Edson Gonçalves Moreira por ter me aceitado como seu primeiro aluno de mestrado e por ter me ajudado muito durante a elaboração do plano de trabalho, artigos, publicação, apresentações e por ter viabilizado minha participação em vários congressos. Muito obrigado mesmo! Agradeço ao grande amigo, pessoa que admiro muito e que sem dúvidas é o maior incentivador de minha carreira acadêmica, M. Sc. Francisco Jorge Ferreira, gerente do ELAI da CETESB. Agradeço a todos os membros da banca de defesa, Dra. Mitiko Saiki (IPEN – CNEN/SP), Dr. Silvio Miranda Prada (UNIFIEO), Dr. Olívio Pereira de Oliveira Júnior (SRC), Dr. José Eduardo Bevilacqua (CETESB) e Dr. Paulo Sérgio Cardoso da Silva (IPEN – CNEN/SP) por aceitarem meu convite e pela valiosa contribuição. Agradeço aos amigos feitos durante o mestrado os quais vivenciaram e fizeram parte do meu dia-a-dia nestes últimos três anos. Agradeço aos pesquisadores, funcionários e colaboradores do LAN, por toda amizade, colaboração e apoio para a realização deste estudo. Agradeço a Dra. Deborah Inês Teixeira Favaro por ter me apresentado ao Dr. Edson Gonçalves Moreira, na época, ainda enquanto eu era candidato a aluno de mestrado. Agradeço a gerência do CRPq pela abertura das portas do Centro para a realização deste trabalho de mestrado. Agradeço a Comissão de Pós Graduação do IPEN – CNEN/SP pela oportunidade de realização deste trabalho de mestrado. Agradeço a Secretaria de Pós Graduação, em especial a Ana Claudia Martinelli Feher por toda atenção, cordialidade e pela ajuda nas questões burocráticas relacionadas a Pós Graduação. Agradeço ao Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) pela bolsa de estudos concedida para a realização deste trabalho de mestrado e pela verba referente a auxílios para participação e apresentação de trabalhos em dois congressos. RESUMO Validação dos métodos de análise por ativação do laboratório de análise por ativação neutrônica do IPEN - CNEN/SP visando a produção de materiais de referência certificados Robson Petroni Este trabalho de mestrado teve como objetivo realizar a validação formal para quatro métodos de medição do Laboratório de Ativação Neutrônica (LAN) do IPEN - CNEN/SP por Análise por Ativação com Nêutrons Instrumental (INAA). Os mensurandos foram a concentração total de As em tecido de mexilhão (método-BIO-1), a concentração total de Co, Cr, Fe, Rb, Sc, Se e Zn em tecido de mexilhão (método-BIO-2), a concentração total de As e Sb em sedimento marinho (método-GEO-1) e a concentração total Co, Cr, Fe, Sc e Zn em sedimento marinho (método-GEO-2). Em um primeiro momento, foi realizado um estudo univariado para investigar a influência causada ao resultado final em diferentes configurações no preparo dos padrões sintéticos e no tempo de medição da atividade do mensurando no padrão sintético. Outras variáveis, como o tempo de medição da atividade do mensurando na amostra, distância entre amostra e detector e tempo de decaimento para medição da amostra foram estudadas em um processo multivariado, por meio da realização de um Planejamento Fatorial 23 completo (DOE). Os parâmetros de desempenho estudados para a validação dos métodos de medição em INAA foram: seletividade, exatidão (precisão e veracidade), linearidade, faixa de trabalho, seletividade, limite de detecção, limite de quantificação, robustez e incerteza de medição. Os métodos foram validados de acordo com as recomendações do Guia de validação do INMETRO DOQ-CGCRE-008. A estimativa das fontes de incertezas foi realizada de acordo com as recomendações do Guia para a expressão da incerteza de medição (ISO GUM) com o uso do método simulado. Palavras-chave: INAA, MRC, validação, planejamento fatorial, ABNT ISO 17025 ABSTRACT Validation of the Neutron Activation Analysis methods of the Neutron Activation Laboratory at IPEN-CNEN/SP aiming the production of certified reference materials Robson Petroni The objective of this study was the validation of four measurement methods by Instrumental Neutron Activation Analysis (INAA) at the Neutron Activation Laboratory (LAN) of IPEN - CNEN/SP. The measurands were: mass fraction of As in biological matrix sample (método-BIO-1), mass fraction of Co, Cr, Fe, Rb, Sc, Se and Zn in biological matrix sample (método-BIO-2), mass fraction of As and Sb in geological matrix sample (método-GEO-1) and mass fraction of Co, Cr, Fe, Sc and Zn in geological matrix sample (método-GEO-2). First, a univariate method optimization was performed to investigate the influence of the the preparation of synthetic standard (monoelemental standard and/or multielemental standard) and standard measurement times. In a second step, a multivariate method optimization was carried to verify the influence of sample measurement time, sample decay time and sample distance to detector by means of a 23 full factorial design (DOE). Investigated method performance characteristics were: selectivity, accuracy (trueness and precision), linearity, work range, selectivity, limit of detection, limit of quantification, robustness and measurement uncertainty. The methods were validated according to recommendations of INMETRO DOQ-CGCRE-008 Validation Guide. The estimate of uncertainty sources was carried out according to recommendations of Guide to the expression of uncertainty in measurement (ISO GUM) using the simulated method. key-words: INAA, CRM, method validation, experimental design, ISO/IEC 17025 SUMÁRIO 1. INTRODUÇÃO........................................................................................... 19 2. SISTEMA DE GESTÃO DA QUALIDADE................................................ 21 2.1. Termos e definições relacionadas à Qualidade........................................... 22 2.2. A série de normas ABNT NBR ISO 9000................................................. 23 2.3. A norma ABNT NBR ISO/IEC 17025..................................................... 25 2.4. BPL: Boas Práticas para Laboratório........................................................ 27 2.5. Metodologias auxiliares ao Sistema de Gestão da Qualidade..................... 28 2.6. O Sistema de Gestão da Qualidade no LAN............................................. 30 2.7. Garantia da Qualidade para resultados de medição..................................... 32 3. OBJETIVOS.............................................................................................. 35 4. VALIDAÇÃO DOS MÉTODOS DE MEDIÇÃO........................................ 36 4.1. Validação pelo método de avaliação indireta............................................ 37 4.1.1. Exatidão....................................................................................... 38 4.1.2. Precisão..................................................................................... 40 4.1.3. Veracidade.................................................................................... 43 4.1.4. Seletividade................................................................................. 43 4.1.5. Limite de detecção e limite de quantificação................................... 44 4.1.6. Robustez..................................................................................... 46 4.1.7. Linearidade...................................................................................... 46 4.1.8. Faixa de trabalho........................................................................ 47 4.1.9. Incerteza de medição.................................................................... 47 4.2. Validação pelo método de avaliação direta................................................ 52 4.2.1. Análise de material de referência certificado.................................. 53 4.2.2. Estudo de comparação interlaboratorial......................................... 54 4.2.3. Ensaio de recuperação................................................................. 55 5. PLANEJAMENTO FATORIAL.................................................................... 57 6. ANÁLISE POR ATIVAÇÃO COM NÊUTRONS........................................ 64 6.1. Principais aplicações do método comparativo de INAA............................. 75 7. PARTE EXPERIMENTAL............................................................................. 77 7.1. Delineamento dos mensurandos e matrizes................................................. 77 7.2. Delineamento dos métodos de medição...................................................... 78 7.3. Delineamento dos MRCs............................................................................ 78 7.4. Ensaios preliminares................................................................................ 79 7.4.1. Verificação da calibração dos balões volumétricos........................ 79 7.4.2. Verificação da calibração de micropipetas..................................... 81 7.5. Preparo das amostras e padrões sintéticos................................................... 82 7.5.1. Lavagem e confecção dos invólucros de polietileno........................ 82 7.5.2. Preparo das amostras..................................................................... 83 7.5.3. Preparo dos padrões sintéticos........................................................ 84 7.6. Montagem do experimento para irradiação................................................ 87 7.7. Montagem das amostras após a irradiação.................................................. 88 7.8. Otimização dos métodos de medição......................................................... 90 7.8.1. Otimização univariada na medição dos padrões sintéticos..................................................................................... 90 7.8.2. Otimização multivariada para os parâmetros de detecção (Planejamento Fatorial, DOE)....................................................... 91 7.9. Validação dos métodos de medição........................................................ 93 7.9.1. Delineamentos importantes para o processo de validação dos métodos de medição....................................................................... 93 7.9.2. Pico analítico de cada mensurando para a medição de raios gama........................................................................................... 94 7.9.3. Precisão...................................................................................... 94 7.9.4. Veracidade................................................................................... 95 7.9.5. Seletividade.................................................................................. 95 7.9.6. Limite de detecção e limite de quantificação................................... 95 7.9.7. Robustez............................................................................................ 95 7.9.8. Linearidade................................................................................... 95 7.9.9. Faixa de trabalho............................................................................. 96 7.9.10. Incerteza de medição....................................................................... 96

Description:
OECD - Organização para a Cooperação e Desenvolvimento Econômico. PDCA - sigla para os .. validação dos métodos de medição trata-se de uma entre uma série de ações à serem tomadas .. arranjos experimentais para realização de pesquisas em física nuclear, física de nêutrons e físi
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.