ACCESSORY CATALOGUE UK and Ireland Issue 2 www.trylon.com ABOUT US Anixter is a leading global supplier of communications and security products and electrical and electronic wire and cable. We help our customers specify solutions and make informed purchasing decisions around technology, applications and relevant standards. Throughout the world, we provide innovative supply chain management solutions to reduce our customers’ total cost of production and implementation. “ Anixter’s value to customers can be summed up in the depth and breadth of our inventory, application-specific technical and product knowledge, and a wide array of inventive Supply Chain Solutions mapped to our customers’ specific requirements.” Bob Eck, President & CEO ANIXTER IS A PROUD DISTRIBUTOR OF TRYLON PRODUCTS. UNITED KINGDOM AND IRELAND INDUSTRIAL Aberdeen Oil and Gas Tel: +44 (0)1224 275680 Birmingham Construction Tel: +44 (0)121 322 7140 Dublin Construction Tel: +353 1 257 2000 Glasgow Construction Tel: +44 (0)1698 503810 Uxbridge Construction Tel: +44 (0)845 604 1301 Warrington Construction Tel: +44 (0)1925 810121 Warrington Rail Tel: +44 (0)870 242 2822 anixter.co.uk anixter.ie OEM Barrow-in-Furness Tel: +44 (0)1229 825871 Chesterfield Tel: +44 (0)1246 451600 Coventry Tel: +44 (0)24 7646 5829 Diss Tel: +44 (0)1379 643506 Glasgow Tel: +44 (0)141 445 2193 Leeds Tel: +44 (0)113 244 0321 Liverpool Tel: +44 (0)151 355 2211 Luton Tel: +44 (0)1582 498900 Newcastle Tel: +44 (0)191 482 7660 Plymouth Tel: +44 (0)1752 341100 Portsmouth Tel: +44 (0)23 9286 5469 Sheffield Tel: +44 (0)1142 709300 Warrington Marine and Defence Tel: +44 (0)1925 816166 anixter.co.uk FOR FURTHER INFORMATION CONTACT YOUR LOCAL ANIXTER REPRESENTATIVE. GLOBAL REACH. LOCAL ADVANTAGE. With Anixter, you get a true local partner around the world. No other distributor of our kind can claim an in-country presence in more than 50 countries and 300 cities. We do business in more than 35 currencies and 30 languages, which means we are uniquely positioned to help facilitate your project in the local environment, reduce risks and keep costs down. CORPORATE SNAPSHOT 5OV0ER 270 NUMBER OF APPROXIMATELY 1YEAR9 FO5UND7ED EMPLOYEES 100,000 APPROXIMATELY WAREHOUSES/ 9,100 COUNTRIES CUSTOMERS BRANCHES IN APPROXIMATELY 300 STOACKX SYEMBOL 500,000 5F0OR0TUNE $$1.1 BILLION PRODUCTS LIST CITIES INVENTORY DIFFERENT WAYS TO BUY FROM ANIXTER eAnixter.com PHONE, FAX, B2B INTEGRATION EPROCUREMENT ANIXTER.COM EMAIL WITH (E.G., EDI, JIT, ERP PUNCHOUT CATALOG (RETAIL PRICING) SALES REP SYSTEMS) (E.G., ARIBA, SCIQUEST) EANIXTER.COM CUSTOM CATALOG (CONTRACT PRICING) (E.G., INTELLIBID, ACCUBID) CUSTOMER BRANDED PHYSICAL STORES ELECTRONIC INVOICES AUTOMATED ORDER E-COMMERCE WEBSITE AND PAYMENTS CONFIRMATION AND (CONTRACT PRICING) CONSOLIDATED INVOICE SHIPMENT NOTIFICATION STATEMENTS Major enhancements coming soon. Anixter Inc. World Headquarters Wire & Cable EMEA Headquarters 2301 Patriot Boulevard Unit A, The Beacons Glenview, Illinois 60026 Birchwood Park 224.521.8000 Birchwood, Warrington Cheshire, WA3 6GP +44 (0) 1925 838658 TABLE OF CONTENTS Table of Contents CE Product Cer(cid:415) fi ca(cid:415) on Example ....................6 2-Way RRU Mount ........................................30 Mount Calcula(cid:415) on Example ............................7 3-Way RRU Mount ........................................31 Antenna/MW Standoff Mounts ......................8 4-Way RRU Mount ........................................32 Yoke Bracket Mount .......................................9 Installa(cid:415) on Drawings ....................................33 Antenna/MW Standoff Mount Installa(cid:415) on ..............................33 Light Duty Wall Mount Assembly ..................10 Yoke Bracket Mount Installa(cid:415) on ...............................................36 Yoke Bracket Mount Without Pipe Installa(cid:415) on .........................37 Wall Mount Assembly ..................................11 Light Wall Mount Installa(cid:415) on ...................................................38 Wall Mount Installa(cid:415) on ............................................................39 Corner Mount Assembly ...............................12 Corner Mount Installa(cid:415) on ........................................................40 Pipe Extension Assembly Installa(cid:415) on .......................................41 Pipe Extension Assembly ..............................13 3-Pipe 3-Sector Spine Mount Installa(cid:415) on .................................42 3-Pipe 3-Sector Spine Mount Without Pipe Installa(cid:415) on ...........43 3-Pipe 3-Sector Spine Mount ........................14 6-Pipe 3-Sector Spine Mount Installa(cid:415) on .................................44 6-Pipe 3-Sector Spine Mount Without Pipe Installa(cid:415) on ...........45 6-Pipe 3-Sector Spine Mount ........................15 Pole Ring Standoff Installa(cid:415) on ..................................................46 Pole Ring Standoff Without Pipe Installa(cid:415) on ...........................47 Pole Ring Standoff ........................................16 2-Level Pole Ring Standoff Installa(cid:415) on .....................................48 2L 6P Pole Ring Standoff Installa(cid:415) on ........................................49 Light Duty Roof Ballast Mount Installa(cid:415) on ...............................50 2-Level Pole Ring Standoff ............................17 Single Pipe Roof Ballast Mount Installa(cid:415) on ..............................51 Double Pipe Roof Ballast Mount Installa(cid:415) on ............................52 2L 6P Pole Ring Standoff ...............................18 4-Hole Feeder Bracket Installa(cid:415) on ...........................................54 6-Hole Feeder Bracket Installa(cid:415) on ...........................................55 Bulk Pipe ......................................................19 Gantry poles Installa(cid:415) on ..........................................................56 Fixed Cross Over Assemblies Installa(cid:415) on..................................57 Light Duty Roo(cid:332) op Ballast Mount .................20 Universal Fixed Cross Over Assemblies Installa(cid:415) on ..................59 2-Way RRU Mount Installa(cid:415) on .................................................60 Single Pipe Roof Ballast Mount .....................21 3-Way RRU Mount Installa(cid:415) on .................................................61 4-Way RRU Mount Installa(cid:415) on .................................................62 Double Pipe Roof Ballast Mount ...................22 Trylon Also Off ers .........................................64 Step Bolt Assembly .......................................24 4-Hole Feeder Bracket ..................................25 6-Hole Feeder Bracket ..................................26 Gantry Poles .................................................27 Fixed Crossover Assembly .............................28 Universal Fixed Crossover Assembly .............29 [email protected] www.trylon.com 4 CE PRODUCT CERTIFICATION EXAMPLE Identification No. 1381 of Notified Body Trylon TSF 21 South Field Drive Elmira, Ontario Canada N2B 0A6 14 Kit Part #4.927.0103.001 Essential Characteristics Declared Performance Harmonized Technical Specification Tolerances on dimensions and In accordance with EN 1090-2 EN 1090-1:2009 shape Weldability Based in S355JR Material, Max CEV % is 0.543 Fracture toughness / brittle As per EN 10025:2004 strength requirements for S275JR & S355JR steel - 27 J at 20° C Impact resistance See Above. Load bearing capacity As per EN-1993-3-1 (2007), Minimum capacity is 4.2kN Deformation at serviceability As per EN-1993-3-1 (2007), limit state Maximum deflection is 0.6mm Fatigue strength NPD Resistance to fire As per EN-13501-1, REI 180 Reaction to fire As per EN-13501-2, A1 Release of Cadmium and its NPD compounds Emission of Radioactivity NPD Durability All products Galvanized to European EN ISO 1461 [email protected] www.trylon.com 5 CE PRODUCT CERTIFICATION EXAMPLE Declaration of Performance (according to REGULATION (EU) No 305/2011) Kit Description: MW Standoff Mount (1m Pipe) Kit Part Number: 4.927.0103.001 DoP Number: 4.927.0103.001 Applicable Harmonized Standard: EN 1090-1:2009 Intended Usage: Antenna Support Mount Manufacturer Information: Trylon TSF 21 South Field Drive Elmira, Ontario Canada N2B 0A6 Tel: (519) 669 – 5421 Website: www.Trylon.com CE Marking Notified Body: SGS Italia S.p.A. Via G. Gozzi 1/a Milan, 20129 Italy Tel: +39 02 73 931 Website: www.sgsgroup.it/ System of assessment and verification of constancy of performance of the product: EXC2 Notified factory production control certification body No. 1381 performed the initial inspection of the manufacturing plant and of factory production control and the continuous surveillance, assessment, and evaluation of factory production control and issued the certificate of conformity of the factory production control Stephanie Berry Date: June 29, 2015 Director of Product Operations Trylon [email protected] www.trylon.com 6 MOUNT CALCULATION EXAMPLE Antenna/MW Standoff Mount (0.5m Pipe) With Medium Backings Kit # 4.927.0108.001 21 South Field Drive, PO Box 186 Design Code: BS8100 Elmira, Ontario, Canada N3B 2Z6 519-669-5421 (ph), 519-669-8912 (fx) INPUT VALUES 1) SITE AND TOWER PARAMETERS Wind Speed* 24.0 m/s Tower Height 60.0 m Antenna Elevation* 60.0 m Site Altitude 100 m 2) ANTENNA Antenna Type* r (Flat,Round) Height of Antenna* 1.50 m Width of Antenna* 0.50 m Weight of Antenna* 50.0 kg 3) MOUNT OPTIONS Number of Mounting Angles* 1 (1 or 2) OK! Length of Horizontal Pipe* 0.5 m (0.5, 1, 2 or 3) Backing* Medium (Medium, Small) 4) MAX ALLOWABLE ANTENNA DEFLECTION PLAN VIEW Relative to tower/wall* 5.00 mm ELEVATION VIEW SUMMARY of RESULTS DESIGNED TO: 24M/S WIND SPEED (1) 1.5M x0.5M ANTENNA Results Capacity Vertical Pipe Bend Check 500mm LONG x 76mm OD x 6mm THK [345MPa] 21.71 MPa 310.28 MPa PASS[1.7%] Horizontal Angle Bend Check 64mm x 64mm x 6mm, 613mm LONG [300MPa] 228.79 MPa 273.04 MPa PASS[83.8%] Backing Channel Bend Check 260mm LONG x 44mm WIDE x 57mm DEEP x 5mm THK [300MPa] 111.15 MPa 273.04 MPa PASS[40.7%] Backing Rod Combined Shear & Tension Check PASS[8.2%] Tower Leg Reactions Per Backing Horizontal 1.35 kN Vertical 0.63 kN Torsional Moment 0.52 kN.m Total mount Deflection 0.55 mm PASS APPROX. MOUNT WEIGHT: 0.60 kN (Antenna and tower connection included) Assumptions: - Areas calculated usings BS8100 guidelines - Quality Class: A - Design based on 50 year return basic wind speed - Terrain Category: III (Typ UK farmland) - Environment Conditions: Adjacent to Main Road - Checked Design for Member Stresses - Usage: Broadcasting - S values are calculated using std tables/formulas - Antenna centrally located on vertical Pipe - Atmospheric environment assumed to by Type (a) as per BS8100, cl. 3.1.1 [email protected] www.trylon.com 7 ANTENNA/MW STANDOFF MOUNTS Kit # Description Qty Weight (kg) 4.927.0108.001 MW Standoff Mount (76mm OD x 0.5m Pipe) Each 13.2 kg 4.927.0103.001 MW Standoff Mount (76mm OD x 1m Pipe) Each 24.5 kg 4.927.0103.002 MW Standoff Mount (76mm OD x 2m Pipe) Each 36.0 kg 4.927.0103.003 MW Standoff Mount (76mm OD x 3m Pipe) Each 47.7 kg 4.927.0103.101 MW Standoff Mount (Without Pipe) Each 14.7 kg MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS8100 30m MOUNT AGL 60m MOUNT AGL Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s Length of Pipe (0.5m) - Round / Flat 1.41 m2 1.23 m2 1.08 m2 1.26 m2 1.10 m2 0.96 m2 0.61 m2 0.52 m2 0.44 m2 0.54 m2 0.45 m2 0.39 m2 Length of Pipe (1m) - Round / Flat 3.95 m2 2.45 m2 2.15 m2 2.52 m2 2.19 m2 1.92 m2 1.24 m2 1.05 m2 0.89 m2 1.08 m2 0.91 m2 0.78 m2 Allowable Antenna Length of Pipe (2m) - Round / Flat Loading 2.74 m2 2.39 m2 2.10 m2 2.46 m2 2.14 m2 1.87 m2 1.20 m2 1.02 m2 0.87 m2 1.05 m2 0.89 m2 0.76 m2 Length of Pipe (3m) - Round / Flat 2.67 m2 2.33 m2 2.05 m2 2.40 m2 2.08 m2 1.82 m2 1.17 m2 0.99 m2 0.85 m2 1.02 m2 0.86 m2 0.74 m2 NOTES: 1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude. 2) Mount assumed at top tower. 3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.1 4) Assumed 50.0 kg antenna weight per square meter of antenna area. 5) See pages 33, 34, and 35 for Installation Drawings [email protected] www.trylon.com 8 YOKE BRACKET MOUNT Kit # Description Qty Weight (kg) 4.927.0102.001 2-Pipe Yoke Bracket Mount (60mm OD x 3m Pipe) Each 77.0 kg 4.927.0102.101 2-Pipe Yoke Bracket Mount (Without Pipe) Each 44.9 kg MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS8100 30m MOUNT AGL 60m MOUNT AGL Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s Allowable Antenna 3.93 m2 3.25 m2 2.73 m2 3.38 m2 2.79 m2 2.34 m2 Loading per Pipe NOTES: 1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude. 2) Antenna assumed at top tower. 3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.1 4) Assumed 50.0 kg antenna weight per square meter of antenna area. 5) See pages 36 and 37 for Installation Drawings [email protected] www.trylon.com 9
Description: