ebook img

Trenching and Conduit PDF

60 Pages·2012·1.14 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Trenching and Conduit

22.00 GENERAL GENERAL INFORMATION 22.00-100 22.01 TRENCHING MINIMUM CABLE COVER AND SEPARATION 22.01-101 TRENCH CONFIGURATIONS 22.01-102A TRENCH CONFIGURATIONS 22.01-102B TRENCH, BACKFILL AND COMPACTION REQUIREMENTS 22.01-104 MARKING TAPE - BURIED ELECTRICAL LINE 22.01-106 22.02 DIRECTIONAL BORING DIRECTIONAL BORING 22.02-100 22.03 CONDUIT USE USES FOR CONDUIT 22.03-100 CONDUIT USE BY TYPE 22.03-102 22.04 CONDUIT AND CONDUIT ACCESSORIES (RIGID) PVC SCHEDULE 40 CONDUIT 22.04-100 PVC COUPLING - STANDARD - WITH CENTER STOP 22.04-102 PVC SLIP COUPLING - NO CENTER STOP 22.04-104 PVC MALE TERMINAL ADAPTER 22.04-106 LOCKNUT 22.04-108 PVC FEMALE ADAPTER 22.04-110 PVC PLUG / END CAP 22.04-112 PVC END BELL 22.04-114 PVC REDUCERS 22.04-116 PVC BENDS - 90 DEGREES - SCHEDULE 40 22.04-118 PVC BENDS - 45 DEGREES - SCHEDULE 40 22.04-120 PVC BENDS - 22-1/2 DEGREES - SCHEDULE 40 22.04-122 PVC SERVICE RISER 22.04-124 PVC VENTED RISERS 22.04-128 CONDUIT SUPPORT STRAPS - WOOD POLE MOUNT 22.04-130 CELLULAR CORE PVC CONDUIT 22.04-134 HIGH DENSITY POLYETHYLENE (HDPE) CONDUIT 22.04-136 HDPE CONDUIT COUPLINGS 22.04-138 STEEL CONDUIT 22.04-140 FIBERGLASS CONDUIT 22.04-142 22.05 CONDUIT INSTALLATION AND REPAIR CUTTING AND JOINING PVC CONDUIT 22.05-100 INSTALL PREBENTS 22.05-102 JOINING 6" PVC TO 7" POLYETHYLENE PIPE 22.05-104 PVC CONDUIT AND CIC INSTALLATION PROCEDURE 22.05-106 REPAIRING EXISTING PVC CONDUIT WHEN CONDUIT CONTAINS CABLE 22.05-108 REPAIRING EXISTING PVC CONDUIT WHEN CONDUIT DOES NOT CONTAIN CABLE 22.05-110 3 DEC DEM DEP DEF SECTION 22 - TRENCHING, DIRECTIONAL BORING, 2 1 CONDUIT & DUCT BANK X 0 12/31/15 KATIGBAK EANES ADCOCK TABLE OF CONTENTS 22.00-00A REVISED BY CK'D APPR. 22.06 DUCT BANKS DUCT BANK DESIGN CRITERIA 22.06-100A DUCT BANK DESIGN CRITERIA 22.06-100B DUCT BANK CONFIGURATIONS TWO WIDE 22.06-102 DUCT BANK CONFIGURATIONS THREE WIDE 22.06-104 DUCT BANK CONFIGURATIONS STREET LIGHTING 22.06-106 DUCT BANK CONFIGURATIONS JOINT USE 22.06-108 DUCT BANK SPACERS 22.06-110 DUCT BANK GROUNDING 22.06-112A DUCT BANK GROUNDING 22.06-112B ESTIMATING CONCRETE 22.06-114 DUCT BANK INSTALLATION INSTRUCTIONS 22.06-116A DUCT BANK INSTALLATION INSTRUCTIONS 22.06-116B DUCT BANK FIELD BENDS 22.06-118 DUCT BANK JOINTS 22.06-120 DUCT BANK INSPECTION CHECKLIST 22.06-124 22.07 CABLE PULLING CABLE PULLING - GENERAL INFORMATION 22.07-100A CABLE PULLING - GENERAL INFORMATION 22.07-100B RECOMMENDED CONDUIT FILL 600V AL AND CU CABLES 22.07-102 RECOMMENDED CONDUIT FILL PRIMARY CABLES 22.07-106 CABLE PULLING LUBRICANTS 22.07-108 PULLING GRIPS FOR UNDERGROUND CABLES 22.07-112A PULLING GRIPS FOR UNDERGROUND CABLES 22.07-112B CABLE PULLING SOFTWARE DSTAR CABLE PULLING ASSISTANT (CPA) 22.07-114 3 DEC DEM DEP DEF SECTION 22 - TRENCHING, DIRECTIONAL BORING, 2 1 CONDUIT & DUCT BANK X 0 12/31/15 KATIGBAK EANES ADCOCK TABLE OF CONTENTS 22.00-00B REVISED BY CK'D APPR. DUKE ENERGY IS A "DIRECT BURIED" UTILITY. THIS MEANS THE COMPANY TYPICALLY DIRECTLY BURIES ALL 600 VOLT AND MEDIUM VOLTAGE PRIMARY CABLE IN THE GROUND WITHOUT THE USE OF CONDUIT. ONE MAJOR EXCEPTION IS THE FACILITIES INSTALLED IN OHIO AND KENTUCKY. CABLES IN THOSE STATES ARE TYPICALLY INSTALLED IN CONDUIT, MUCH OF WHICH IS PROVIDED BY THE CUSTOMER. THIS IS DONE TO COMPLY WITH STATE REGULATIONS. OTHER EXAMPLES OF SITUATIONS WHERE CABLE MAY BE INSTALLED IN CONDUIT OR AN EMPTY CONDUIT INSTALLED FOR FUTURE USE IS PROVIDED ON DWG. 22.03-100 (USES FOR CONDUIT). CONDUIT IS NOT REQUIRED FOR DIRECTIONAL BORE INSTALLATIONS EXCEPT WHEN MANDATED BY THE P ERMITTING AUTHORITY. REFER TO SECTION 36 FOR THE FOLLOWING INFORMATION: CLEARANCES JOINT USE TRENCH DESIGNS TRENCHING NEAR STRUCTURES TRENCHING/DIRECTIONAL BORING NEAR TREES 3 DEC DEM DEP DEF 2 1 GENERAL INFORMATION X X X X 0 12/31/15 FLETCHER EANES ADCOCK 22.00-100 REVISED BY CK'D APPR. TABLE 1: MINIMUM CABLE COVER CABLE OR APPLICATION MINIMUM COVER SPECIFIC NOTES JOINT TRENCH SECONDARY / SERVICE 30" SEE NOTES 2 AND 3 (cid:51)(cid:53)(cid:44)(cid:48)(cid:36)(cid:53)(cid:60)(cid:3)(cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12) 36" SEE NOTES 2 AND 3 SEE SECTION 36 X ROAD CROSSINGS (ANY VOLTAGE) 36" SEE NOTE 5 FOR JOINT TRENCH RAILROAD CROSSINGS (ANY VOLTAGE) PERMIT SPECIFIC SEE NOTE 5 CONSTRUCTION PARKING LOT CROSSINGS (ANY VOLTAGE) 36" SEE NOTES 2, 3 AND 5 TABLE 2: REQUIRED MINIMUM SEPARATION BETWEEN CABLES WHEN SEPARATION IS TO BE OBTAINED HORIZONTALLY (CABLES ARE BURIED AT THE SAME DEPTH) COLUMN 1 MINIMUM HORIZONTAL SEPARATION FROM CABLES IN COLUMN 1 PRIMARY, 200A PRIMARY, 200A PRIMARY, (cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12)(cid:3)(cid:58)(cid:43)(cid:40)(cid:49) (cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12)(cid:3)(cid:58)(cid:43)(cid:40)(cid:49) SECONDARY/ FEEDER CABLE 200A BOTH CABLES BOTH CABLES SERVICE (>200A) (cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12) ARE NOT PART OF ARE PART OF THE SAME LOOP THE SAME LOOP SECONDARY / RANDOM LAY RANDOM LAY 36" SERVICE X PRIMARY, 200A RANDOM LAY RANDOM LAY* 36" 36" (cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12) FEEDER (>200A) 36" 36" 36" *SEE NOTE 7 FOR ADDITIONAL DEC REQUIREMENT TABLE 3: REQUIRED MINIMUM SEPARATION BETWEEN CABLES WHEN SEPARATION IS TO BE OBTAINED VERTICALLY (CABLES ARE BURIED AT THE DIFFERENT DEPTHS) COLUMN 1 MINIMUM VERTICAL SEPARATION FROM CABLES IN COLUMN 1 PRIMARY, 200A PRIMARY, 200A PRIMARY, (cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12)(cid:3)(cid:58)(cid:43)(cid:40)(cid:49) (cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12)(cid:3)(cid:58)(cid:43)(cid:40)(cid:49) SECONDARY/ FEEDER CABLE 200A BOTH CABLES BOTH CABLES SERVICE (>200A) (cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12) ARE NOT PART OF ARE PART OF THE SAME LOOP THE SAME LOOP SECONDARY / RANDOM LAY RANDOM LAY 12" SERVICE X PRIMARY, 200A RANDOM LAY RANDOM LAY* 12" 12" (cid:11)(cid:20)(cid:145)(cid:3)(cid:50)(cid:53)(cid:3)(cid:22)(cid:145)(cid:12) FEEDER (>200A) 12" 12" SEE NOTE 6 *SEE NOTE 7 FOR ADDITIONAL DEC REQUIREMENT NOTES: 1. MINIMUM SEPARATION BETWEEN CABLES MAY BE OBTAINED EITHER HORIZONTALLY OR VERTICALLY. 2. IF REQUIRED MINIMUM DEPTH CANNOT BE OBTAINED, INSTALL CABLE IN SCHEDULE 40 OR GREATER CONDUIT WITH A MINIMUM OF TWO (2) INCHES OF CONCRETE ABOVE AND BESIDE THE CONDUIT AND A MINIMUM OF SIX (6) INCHES OF COVER. 3. RISER CONDUIT BENDS AND BRIDGE TRANSITIONS ARE EXCEPTIONS TO THE MINIMUM COVER REQUIREMENT. 4. REFER TO SECTION 36 FOR JOINT TRENCH INFORMATION AND CONSTRUCTION DETAILS. 5. IF PERMIT IS REQUIRED, MINIMUM DEPTH WILL BE PERMIT SPECIFIC RATHER THAN THE DEPTH LISTED, BUT NEVER LESS THAN NESC REQUIREMENTS. 6. FEEDERS (>200A) MUST BE SEPARATED HORIZONTALLY BY 36". VERTICAL SEPARATION ONLY IS NOT AN OPTION. (cid:26)(cid:17)(cid:3)(cid:39)(cid:40)(cid:38)(cid:3)(cid:53)(cid:40)(cid:52)(cid:56)(cid:44)(cid:53)(cid:40)(cid:54)(cid:3)(cid:36)(cid:3)(cid:48)(cid:44)(cid:49)(cid:44)(cid:48)(cid:56)(cid:48)(cid:3)(cid:50)(cid:41)(cid:3)(cid:20)(cid:21)(cid:5)(cid:3)(cid:57)(cid:40)(cid:53)(cid:55)(cid:44)(cid:38)(cid:36)(cid:47)(cid:3)(cid:54)(cid:40)(cid:51)(cid:36)(cid:53)(cid:36)(cid:55)(cid:44)(cid:50)(cid:49)(cid:3)(cid:37)(cid:40)(cid:55)(cid:58)(cid:40)(cid:40)(cid:49)(cid:3)(cid:20)(cid:145)(cid:3)(cid:36)(cid:49)(cid:39)(cid:3)(cid:22)(cid:145)(cid:3)(cid:38)(cid:36)(cid:37)(cid:47)(cid:40)(cid:54)(cid:3)(cid:36)(cid:49)(cid:39)(cid:3)(cid:37)(cid:40)(cid:55)(cid:58)(cid:40)(cid:40)(cid:49) (cid:54)(cid:40)(cid:38)(cid:50)(cid:49)(cid:39)(cid:36)(cid:53)(cid:60)(cid:18)(cid:54)(cid:40)(cid:53)(cid:57)(cid:44)(cid:38)(cid:40)(cid:3)(cid:36)(cid:49)(cid:39)(cid:3)(cid:22)(cid:145)(cid:3)(cid:38)(cid:36)(cid:37)(cid:47)(cid:40)(cid:54)(cid:17) 8. TABLES 2 AND 3 SPECIFY APPLICATIONS THAT REQUIRE SEPARATION BETWEEN CABLES. ALL OTHER APPLICATIONS WILL USE "RANDOM LAY" WHICH MEANS CABLES MAY BE PLACED INTO A TRENCH WITH NO REQUIRED SEPARATION. 9. EITHER ONE WIDE TRENCH OR TWO NARROW TRENCHES MAY BE USED, BASED ON ECONOMICS, TO OBTAIN REQUIRED HORIZONTAL SEPARATION. 3 DEC DEM DEP DEF 2 1 MINIMUM CABLE COVER AND SEPARATION X X X X 0 12/31/15 FLETCHER EANES ADCOCK 22.01-101 REVISED BY CK'D APPR. FINAL GRADE FINAL GRADE FIGURE 1 FIGURE 2 30" 36" 12" SECONDARY/ SERVICE WITH SECONDARY/ SERVICE WITH 200A SINGLE-PHASE PRIMARY 200A THREE-PHASE PRIMARY FINAL GRADE OPTIONAL METHODS FINAL GRADE FIGURE 3 FIGURE 4 30" 36" 6" 12" 12" SECONDARY/ SERVICE WITH SECONDARY/ SERVICE WITH TWO 200A SINGLE-PHASE PRIMARIES TWO 200A SINGLE-PHASE PRIMARIES THAT ARE BOTH PART OF THE SAME LOOP THAT ARE BOTH PART OF THE SAME LOOP FINAL GRADE FIGURE 5 36" 12" ONE 200A SINGLE-PHASE PRIMARY WITH ONE 200A THREE-PHASE PRIMARY NOTES: 1 . SEE DWG. 22.01-102B FOR NOTES. 2. THESE CONFIGURATIONS ARE REQUIRED FOR DEC ONLY. THEY ARE OPTIONAL FOR ALL OTHER LOCATIONS. 3. CABLES AT THE SAME DEPTH CAN BE RANDOM LAY. 3 DEC DEM DEP DEF 2 1 TRENCH CONFIGURATIONS X X X X 0 12/31/15 FLETCHER EANES ADCOCK 22.01-102A REVISED BY CK'D APPR. FINAL GRADE FINAL GRADE FIGURE 2 FIGURE 1 36" 36" 36" 36" TWO 200A THREE-PHASE PRIMARIES TWO SINGLE-PHASE PRIMARY CABLES BOTH PART OF THE SAME LOOP OR BOTH PART OF THE SAME LOOP 200A THREE-PHASE WITH A FEEDER (>200A) OR TWO FEEDERS (>200A) FINAL GRADE FINAL GRADE FIGURE 3 FIGURE 4 36" 36" 36" 36" SINGLE-PHASE WITH A FEEDER (>200A) SECONDARY/SERVICE WITH A FEEDER (>200A) FINAL GRADE FIGURE 5 PRIMARY: 36" MIN. COVER SECONDARY/SERVICE: 30" MIN. COVER RANDOM LAY NOTES: 1. THE TRENCH CONFIGURATIONS SHOWN ON DWG. 22.01-102A AND THIS DRAWING WITH A SPECIFIED SEPARATION BETWEEN CABLES ARE THE ONLY APPLICATIONS THAT REQUIRE SEPARATION BETWEEN CABLES. SEPARATION MAY BE OBTAINED EITHER VERTICALLY AS SHOWN ON DWG. 22.01-102A OR HORIZONTALLY AS SHOWN ON THIS DRAWING. ALL OTHER APPLICATIONS WILL USE THE RANDOM LAY CONFIGURATION SHOWN ABOVE IN FIGURE 5. RANDOM LAY ALLOWS CABLES TO BE PLACED INTO A TRENCH WITH NO REQUIRED SEPARATION. 2. EITHER ONE WIDE TRENCH OR TWO NARROW TRENCHES MAY BE USED BASED ON ECONOMICS TO OBTAIN REQUIRED HORIZONTAL CABLE SEPARATION. 3. IF REQUIRED CABLE SEPARATION CANNOT BE OBTAINED DUE TO SPACE LIMITATIONS, PROVIDE MECHANICAL PROTECTION BY INSTALLING THE CABLE IN SCHEDULE 40 OR GREATER PVC CONDUIT WITH A MINIMUM OF TWO (2) INCHES OF CONCRETE ABOVE AND BESIDE THE CONDUIT. 4. JOINT TRENCH CONFIGURATIONS ARE PROVIDED IN SECTION 35: UNDERGROUND CLEARANCES AND JOINT USE. 3 DEC DEM DEP DEF 2 1 TRENCH CONFIGURATIONS X X X X 0 12/31/15 FLETCHER EANES ADCOCK 22.01-102B REVISED BY CK'D APPR. TRENCH RIGHTS-OF-WAY/EASEMENTS AND STREETS SHALL BE CLEARED AND TO FINAL GRADE BEFORE TRENCHING BEGINS. STANDARD TRENCH DEPTHS ARE SHOWN ON DWGS. 21.01-102A AND 21.01-102B. DUKE ENERGY REQUIRES A MINIMUM COVER OF THIRTY (30) INCHES FOR 600V CABLE AND THIRTY-SIX (36) INCHES FOR MEDIUM VOLTAGE (PRIMARY) CABLE. REFER TO DWG. 22.01-101 WHEN IT IS NOT POSSIBLE TO OBTAIN THE ABOVE DEPTHS. THE BOTTOM OF THE TRENCH SHALL BE SMOOTH, UNDISTURBED EARTH, WELL-TAMPED CLEAN BACKFILL OR SAND, FREE OF ROCKS, DEBRIS OR ROOTS. WHEN EXCAVATION IS IN ROCK OR ROCKY SOIL, CABLE, CONDUITS O R CABLE-IN-CONDUIT SHALL BE LAID ON A WELL-TAMPED LAYER OF CLEAN BACKFILL AT LEAST FOUR (4) INCHES T HICK. SHORING THE PERFORMANCE OF EXCAVATION WORK INCLUDING TRENCHING, SLOPING, BENCHING, AND SHORING MUST, A T MINIMUM, MEET THE REQUIREMENTS OF OSHA 1926 SUBPART P AND ANY LOCAL JURISDICTIONAL R EQUIREMENTS. REFER TO THE TRENCHING AND EXCAVATIONS SECTION OF THE HEALTH AND SAFETY HANDBOOK FOR DUKE ENERGY REQUIREMENTS. BACKFILL BACKFILL WITHIN SIX (6) INCHES OF THE CABLE OR CONDUIT SHALL BE FREE OF ROCK OR ANY MATERIAL THAT MAY DAMAGE THE CABLE OR CONDUIT. THE REMAINING BACKFILL SHOULD BE FREE OF MATERIAL GREATER THAN FOUR (4) INCHES IN MAXIMUM DIMENSION. COMPACTION BACKFILL MUST BE ADEQUATELY COMPACTED. BACKFILL SHALL BE COMPACTED SUCH THAT WASHING AND SETTLING OF THE TRENCH SURFACE WILL NOT OCCUR. ADDITIONAL BUILDUP OF THE BACKFILL MAY BE NECESSARY TO PREVENT SETTLING. FINAL SURFACE COMPACTION SHALL LIMIT THE AMOUNT OF SETTLING TO 1/2" OR LESS. ANY REWORK OF THE TRENCH IS THE RESPONSIBILITY OF THE INSTALLER. MACHINE COMPACTION SHALL NOT BE USED WITHIN SIX (6) INCHES OF THE CABLE OR CONDUIT. WHEN MACHINE COMPACTION IS REQUIRED, TRENCHES SHALL BE BACKFILLED BY ALTERNATING FILL AND TAMPING THE FIRST 12 INCHES AND IN EACH ADDITIONAL 12 INCH INCREMENT. COMPACTION FOR STREET CROSSINGS MUST COMPLY WITH LOCAL JURISDICTIONAL REQUIREMENTS. EXTREME SLOPES OR OTHER UNUSUAL FIELD CONDITIONS MAY REQUIRE ADDITIONAL MECHANICAL TAMPING OR SODDING AT THE DISCRETION OF THE FIELD ENGINEER OR COMPANY DESIGNATED REPRESENTATIVE. 3 DEC DEM DEP DEF 2 1 TRENCH, BACKFILL AND COMPACTION REQUIREMENTS X X X X 0 12/31/15 FLETCHER EANES ADCOCK 22.01-104 REVISED BY CK'D APPR. BACKFILL 36" TYPICAL MARKING TAPE - "CAUTION ELECTRIC LINE BURIED BELOW" 12" MIN. 24" MAX. BACKFILL PRIMARY CABLE REGION COMPATIBLE UNIT ITEM NUMBER DEC 0354165, 2352, 2352INF 354165 DEM - 50086491 DEP - 21149505 DEF - 21149505 NOTES: 1. THE USE OF MARKING TAPE DOES NOT GUARANTEE A REDUCTION IN DIG-INS. AS A RESULT, IT IS NOT RECOMMENDED FOR REGULAR USAGE. HOWEVER, MARKING TAPE IS AVAILABLE FOR INSTALLATION AT THE REQUEST OF A CUSTOMER OR GOVERNMENT AGENCY. NORMAL CHARGING PRACTICES WILL APPLY. 2. CONSIDERATION SHOULD BE GIVEN TO PLACING CABLES IN CONDUIT, CONCRETE ENCASED CONDUIT, OR DUCT BANK IN ORDER TO REDUCE DIG-INS. 3. MARKING TAPE IS A 3" (6" IN DEM) WIDE RED TAPE WITH "CAUTION ELECTRIC LINE BURIED BELOW" PRINTED REPEATEDLY ALONG ITS LENGTH AND IS SUPPLIED IN 1,000 FOOT ROLLS. 4. INSTALL MARKING TAPE 12" MINIMUM TO 24" MAXIMUM ABOVE THE PRIMARY CABLE. 3 DEC DEM DEP DEF 2 1 MARKING TAPE - BURIED ELECTRICAL LINE X X X X 0 12/31/15 FLETCHER EANES ADCOCK 22.01-106 REVISED BY CK'D APPR. OVERVIEW DIRECTIONAL BORING IS A STEERABLE TRENCHLESS METHOD OF INSTALLING UNDERGROUND CABLES, CONDUITS AND PIPES ALONG A PRESCRIBED PATH BY USING A SURFACE LAUNCHED DRILLING RIG. THIS METHOD HAS MINIMAL IMPACT ON THE SURROUNDING AREA. IT IS TYPICALLY USED WHEN TRENCHING OR EXCAVATING IS NOT PRACTICAL (I.E. UNDER CONCRETE OR PAVEMENT) OR WHEN CUSTOMER SATISFACTION (I.E. CABLE REPLACEMENT) IS A MAJOR CONCERN. PROCESS THE DRILLING RIG, POSITIONED AT THE STARTING POINT, PUSHES THE DRILLING HEAD INTO THE SOIL AND PUMPS FLUID TO THE HEAD. THE FLUID, TYPICALLY BENTONITE, IS PUMPED AT HIGH PRESSURE IN FRONT OF THE DRILLING HEAD IN THE DIRECTION THE OPERATOR WANTS THE HEAD TO TRAVEL. THIS FLUID SOFTENS THE SOIL IN THAT DIRECTION AND THE HEAD MOVES IN THAT DIRECTION SINCE IT IS THE PATH OF LEAST RESISTANCE. THAT IS HOW THE OPERATOR STEERS THE DRILLING HEAD ALONG THE ROUTE TO THE RECEIVING POINT AT THE END OF THE BORE. THE FLUID ALSO COOLS THE HEAD AND HELPS TO REMOVE DISLODGED SOIL. (cid:55)(cid:43)(cid:40)(cid:3)(cid:39)(cid:53)(cid:44)(cid:47)(cid:47)(cid:44)(cid:49)(cid:42)(cid:3)(cid:43)(cid:40)(cid:36)(cid:39)(cid:3)(cid:44)(cid:54)(cid:3)(cid:38)(cid:50)(cid:49)(cid:49)(cid:40)(cid:38)(cid:55)(cid:40)(cid:39)(cid:3)(cid:55)(cid:50)(cid:3)(cid:43)(cid:44)(cid:42)(cid:43)(cid:3)(cid:54)(cid:55)(cid:53)(cid:40)(cid:49)(cid:42)(cid:55)(cid:43)(cid:3)(cid:54)(cid:55)(cid:40)(cid:40)(cid:47)(cid:3)(cid:179)(cid:53)(cid:50)(cid:39)(cid:54)(cid:180)(cid:3)(cid:55)(cid:43)(cid:36)(cid:55)(cid:3)(cid:36)(cid:53)(cid:40)(cid:3)(cid:36)(cid:51)(cid:51)(cid:53)(cid:50)(cid:59)(cid:44)(cid:48)(cid:36)(cid:55)(cid:40)(cid:47)(cid:60)(cid:3)(cid:20)(cid:19)(cid:3)(cid:55)(cid:50)(cid:3)(cid:20)(cid:24) FEET LONG. THE DRILLING CREW CONTINUES TO ADD ADDITIONAL RODS UNTIL THE DRILLING HEAD REACHES THE END OF THE BORE. ONCE THE INITIAL BORE IS COMPLETE, THE OPERATOR PULLS A REAMING HEAD BACK THROUGH THE BORE TOWARD THE DRILLING RIG. AT THE SAME TIME, CABLE, CONDUIT OR PIPE IS PULLED BACK THROUGH THE BORE. DUKE ENERGY REQUIREMENT DIRECTIONAL DRILLING EQUIPMENT CAN APPLY EXCESSIVE TENSION WHICH CAN SERIOUSLY DAMAGE CABLE BEING PULLED THROUGH A BORE. FOR THE ABOVE REASON, DUKE ENERGY REQUIRES DIRECTIONAL DRILLING CONTRACTORS TO UTILIZE A TENSION LIMITING DEVICE WHEN PULLING CABLE THROUGH A BORE. THIS CAN BE A PIECE OF BARE #6 AWG SOLID COPPER WIRE FOR 1/0 AWG MEDIUM VOLTAGE CABLE. TENSION LIMITING ATTACHMENTS (TYPICALLY BREAK-AWAY DEVICES) ARE AVAILABLE FROM VARIOUS TOOL MANUFACTURERS FOR USE WITH OTHER CABLES. MAXIMUM ALLOWABLE PULLING TENSIONS FOR ALL MEDIUM VOLTAGE CABLES ARE PROVIDED IN SECTION 23 (UNDERGROUND CABLES). DIRECTIONAL BORING NEAR TREES SEE SECTION 36, UNDERGROUND CLEARANCES AND JOINT USE, FOR DETAILS. 3 DEC DEM DEP DEF 2 1 DIRECTIONAL BORING X X X X 0 12/31/15 FLETCHER EANES ADCOCK 22.02-100 REVISED BY CK'D APPR. DUKE ENERGY TYPICALLY DIRECT BURIES ALL 600 VOLT AND MEDIUM VOLTAGE PRIMARY CABLE IN THE GROUND WITHOUT THE USE OF CONDUIT. HOWEVER, LISTED BELOW ARE SOME EXAMPLES OF SITUATIONS WHERE CABLE MAY BE INSTALLED IN CONDUIT OR SPARE (EMPTY) CONDUITS INSTALLED. FUTURE MAINTENANCE (REPLACEMENT) CONSIDERATIONS APPLICATIONS WHERE FUTURE REPLACEMENT OF CABLE WOULD NOT BE POSSIBLE USING TRENCHING OR DIRECTIONAL BORING METHODS. DIRECTIONAL BORING LIMITATIONS ARE AS FOLLOWS: BORE WOULD BE LONGER THAN MAXIMUM CABLE FOOTAGE ON A REEL BORE LENGTH EXCEEDS EQUIPMENT CAPABILITIES (TYPICALLY 500' BUT CONSULT WITH CONTRACTOR) EXCESSIVE CABLE PULLING TENSIONS THROUGH CONDUIT WOULD BE ENCOUNTERED NOT ADEQUATE "GREEN" SPACE FOR BORE PITS PROJECT TIMING CROSSINGS UNDER PAVEMENT WHERE CABLE CANNOT BE INSTALLED PRIOR TO THE PAVEMENT. EFFORT SHOULD BE MADE TO INSTALL CABLE IF TIMING AND FIELD CONDITIONS ALLOW. CUSTOMER REQUEST THE DUKE ENERGY STANDARD IS TO PROVIDE DIRECT-BURIED UNDERGROUND CABLES. CUSTOMER REQUESTS FOR A CONDUIT INSTALLATION SHOULD BE EVALUATED ON A CASE-BY-CASE BASIS AND WILL REQUIRE MANAGEMENT APPROVAL. THE CUSTOMER WILL BE RESPONSIBLE FOR PAYING ALL ADDITIONAL COSTS ASSOCIATED WITH THE REQUEST (I.E. CONDUIT, PULL BOXES, SPLICES, PULLING LABOR, ETC.) SPECIFIC REGULATIONS RAILROAD AND GAS TRANSMISSION CROSSINGS CROSSING OTHER UTILITIES WHEN CODE CLEARANCES CANNOT BE MET REQUIRED BY DOT OR OTHER GOVERNMENTAL AGENCIES SUBSTATION EXITS TO THE TERMINATION POINT FUTURE GROWTH CONDUIT MAY BE NECESSARY TO ACCOMMODATE FUTURE PROJECT EXPANSIONS OR LOAD GROWTH. FOR LONGER TERM PROJECTS, AN ECONOMIC ANALYSIS SHOULD BE PERFORMED TO DETERMINE THE BEST OPTION (I.E. INSTALL CONDUIT NOW VS BORE IN THE FUTURE). SHALLOW INSTALLATIONS CABLE SHALL BE INSTALLED IN CONCRETE-ENCASED CONDUIT WHEN MINIMUM CABLE COVER REQUIREMENTS CANNOT BE MET. SEE DWG. 22.01-101 FOR DETAILS. RADIAL PRIMARY FEEDS WHEN THE MAJORITY OF THE CABLE SUPPLYING A SINGLE RADIAL-FED TRANSFORMER IS UNDER PAVEMENT OR CONCRETE, THE CABLE CAN BE INSTALLED IN CONDUIT OR AN EMPTY CONDUIT CAN BE INSTALLED ALONG THE ENTIRE ROUTE. CABLE MAY ALSO BE INSTALLED IN CONDUIT AND EMPTY CONDUIT INSTALLED FOR FUTURE CABLE INSTALLATION WHEN IT IS SERVING A "SHORT-TERM RADIALLY-FED TRANSFORMER" (THE LOOP WILL BE COMPLETED AT SOME POINT IN THE FUTURE) WHEN IT WILL NOT BE POSSIBLE TO TRENCH AROUND THE TRANSFORMER OR DIRECTIONALLY BORE IN THE AREA TO INSTALL THE FUTURE CABLE. DUCT BANK MANY CITIES REQUIRE UTILITIES TO INSTALL THEIR FACILITIES UNDERGROUND IN DESIGNATED INNER-CITY AREAS. CABLE WOULD BE INSTALLED IN CONCRETE ENCASED DUCT BANK IN THESE DESIGNATED AREAS. SEE THE DUCT BANK PORTION OF THIS SECTION FOR DETAILS. THERE MAY ALSO BE HEAVILY CONGESTED URBAN AREAS OUTSIDE OF THE INNER-CITY AREA WHERE EITHER DUKE ENERGY CHOOSES OR THE CITY MANDATES FOR UTILITIES TO INSTALL FACILITIES UNDERGROUND. CABLE WOULD BE INSTALLED IN CONCRETE ENCASED DUCT BANK IN THESE DESIGNATED AREAS. SEE SUBSECTION 22.06 FOR DETAILS. DIRECTIONAL BORING WHEN CABLE PLACEMENT HAS TO BE DEEPER THAN 48" IF ANY OF THE ABOVE APPLICATIONS APPLY MISCELLANEOUS ROCKY SOIL ROUGH TERRAIN 3 DEC DEM DEP DEF 2 1 USES FOR CONDUIT X X X X 0 12/31/15 FLETCHER EANES ADCOCK 22.03-100 REVISED BY CK'D APPR.

Description:
SECTION 22 - TRENCHING, DIRECTIONAL BORING,. CONDUIT & DUCT BANK. TABLE OF CONTENTS. DUCT BANK DESIGN CRITERIA. 22.06-100A. 0. 1. REVISED. BY. CK'D. 2. APPR. 3. 22.06 DUCT BANKS. 22.07 CABLE PULLING. 12/31/15. KATIGBAK. EANES. ADCOCK. 22.00-00B. DEF. DEP.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.