ebook img

Three Case Studies of High Reliability Power - IEEE - Argentina PDF

107 Pages·2010·2.58 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Three Case Studies of High Reliability Power - IEEE - Argentina

TThhrreeee CCaassee SSttuuddiieess ooff HHiigghh RReelliiaabbiilliittyy PPoowweerr SSyysstteemmss KKeeeennee MM.. MMaattssuuddaa,, PP..EE.. SSeenniioorr MMeemmbbeerr IIEEEEEE IIEEEEEE//PPEESS DDiissttiinngguuiisshheedd LLeeccttuurreerr kkee..mmaattssuuddaa@@iieeeeee..oorrgg BBuueennooss AAiirreess,, AArrggeennttiinnaa JJuunnee 2255 && 2266,, 22000099 Project No. 1: H-3 Tunnel Project No. 1: H-3 Tunnel 1.6 km (1 mile) long, twin-bore (cid:132) 1.6 km (1 mile) long, twin-bore (cid:132) tunnel thru Koolau mountains tunnel thru Koolau mountains Part of 26-km highway in (cid:132) Part of 26-km highway in (cid:132) Honolulu, Hawaii Honolulu, Hawaii Tunnel connects Halawa valley to (cid:132) Tunnel connects Halawa valley to (cid:132) west and Haiku valley to east west and Haiku valley to east Cost: $1.3 billion (US) = 90% from (cid:132) Cost: $1.3 billion (US) = 90% from (cid:132) FHWA + 10% from HDOT FHWA + 10% from HDOT Photo: Haiku Portal Photo: Haiku Portal Haiku Portal - Inbound Tunnel Haiku Portal - Outbound Tunnel Photo: Haiku Cross-Over Photo: Haiku Cross-Over Haiku Cross- Over Vault 4 Sources of power 4 Sources of power For high reliability, 4 sources: (cid:132) For high reliability, 4 sources: (cid:132) 2 utility HV transmission circuits (cid:132) 2 utility HV transmission circuits (cid:132) 1-500 kW emergency generator (cid:132) 1-500 kW emergency generator (cid:132) Numerous UPS and (cid:132) Numerous UPS and (cid:132) battery/inverter units battery/inverter units Utility power source Utility power source 2-46 kV HECO transmission lines (cid:132) 2-46 kV HECO transmission lines (cid:132) for high reliability for high reliability Radial circuits terminate at portal (cid:132) Radial circuits terminate at portal (cid:132) substations: Halawa & Haiku substations: Halawa & Haiku Separate substations for (cid:132) Separate substations for (cid:132) redundancy redundancy 10 MVA, 46-12.47 kV transformer, (cid:132) 10 MVA, 46-12.47 kV transformer, (cid:132) fully sized for redundancy fully sized for redundancy Photo: Transformer Photo: Transformer HECO 46 kV Incoming Ckt Photo: Transformer Photo: Transformer HECO 10 MVA Substation Slide 8 Emergency power sources Emergency power sources Emergency diesel engine- (cid:132) Emergency diesel engine- (cid:132) generator: 500 kW, 480 V generator: 500 kW, 480 V UPS units (15 min. battery (cid:132) UPS units (15 min. battery (cid:132) capacity): computer-type loads capacity): computer-type loads Fast transfer battery/inverter units (cid:132) Fast transfer battery/inverter units (cid:132) (90 min. battery capacity): HID (90 min. battery capacity): HID lighting lighting Photo: Transformer Photo: Transformer 500 kW Emergency Generator Slide 10

Description:
10 MVA, 46-12.47 kV transformer, fully sized for Fast transfer battery/inverter units. (90 min. Power. ATS. UPS. Building Power and. Lighting Emergency. Panelboard . Energize 43COMP relay = manual . 500 kW solar photovoltaic array.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.