ebook img

Product Manual to support the Parker SSD 890SD series stand-alone AC drives PDF

578 Pages·2013·5.17 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Product Manual to support the Parker SSD 890SD series stand-alone AC drives

aerospace AC890 climate control electromechanical Frame G, H & J filtration fluid & gas handling hydraulics HA471397U003 Issue 8 Compatible with Software Version 3.7 onwards pneumatics process control Product Manual sealing & shielding ENGINEERING YOUR SUCCESS. AC890 Engineering Reference : Product Manual : Frames G, H & J HA471397U003 Issue 7 Compatible with Software Version 3.7 2012 Parker SSD Drives, a division of Parker Hannifin Ltd. All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form or by any means to persons not employed by a Parker Hannifin Manufacturing Limited company without written permission from Parker Hannifin Manufacturing Limited. Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Parker Hannifin Manufacturing Limited cannot accept responsibility for damage, injury, or expenses resulting therefrom. WARRANTY The general terms and conditions of sale of goods and/or services of Parker Hannifin Europe Sarl, Luxembourg, Switzerland Branch, Etoy, apply to this product unless otherwise agreed. The terms and conditions are available on our website www.parker.com/termsandconditions/switzerland Parker Hannifin Manufacturing Limited reserves the right to change the content and product specification without notice. FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalogue and in any other materials provided from Parker Hannifin Corporation or its subsidiaries or authorized distributors. To the extent that Parker Hannifin Corporation or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. The above disclaimer is being specifically brought to the user’s attention and is in addition to and not in substitution to the Exclusions and Limitations on Liability which are set out in the terms and conditions of sale. Safety Chapter 1 Safety Please read these important Safety notes before installing and operating this equipment. Caution WARNING CAUTION notes in the manual warn of danger WARNING notes in the manual warn of to equipment. danger to personnel. 890SD Standalone Drive - Frames G, H & J Page 1-1 Safety Requirements IMPORTANT Please read this information BEFORE installing the equipment. Intended Users This manual is to be made available to all persons who are required to install, configure or service equipment described herein, or any other associated operation. The information given is intended to highlight safety issues, and to enable the user to obtain maximum benefit from the equipment. Complete the following table for future reference detailing how the unit is to be installed and used. INSTALLATION DETAILS Model Number Where installed (see product label) (for your own information) Unit used as a:  Component  Relevant Apparatus Unit fitted:  Wall-mounted  Enclosure (refer to Certification) Application Area The equipment described is intended for industrial motor speed control utilising AC induction or AC synchronous machines. Personnel Installation, operation and maintenance of the equipment should be carried out by qualified personnel. A qualified person is someone who is technically competent and familiar with all safety information and established safety practices; with the installation process, operation and maintenance of this equipment; and with all the hazards involved. Page 1-2 890SD Standalone Drive - Frames G, H & J Safety Product Warnings Earth/Ground Caution Caution Protective Conductor Risk of electric shock Refer to documentation Terminal Hazards DANGER! - Ignoring the following may result in injury 1. This equipment can endanger life by exposure to 5. For measurements use only a meter to IEC 61010 (CAT III or rotating machinery and high voltages. higher). Always begin using the highest range. CAT I and CAT II meters must not be used on this product. 2. The equipment must be permanently earthed due to the high earth leakage current, and the drive motor must be connected to an appropriate safety earth. 6. Allow at least 5 minutes for the drive's capacitors to discharge to safe voltage levels (<50V). Use the specified meter capable 3. Ensure all incoming supplies are isolated before of measuring up to 1000V dc & ac rms to confirm that less working on the equipment. Be aware that there may than 50V is present between all power terminals and between be more than one supply connection to the drive. power terminals and earth. 4. There may still be dangerous voltages present at power terminals (motor output, supply input phases, 7. Unless otherwise stated, this product must NOT be dismantled. DC bus and the brake, where fitted) when the motor is In the event of a fault the drive must be returned. Refer to at standstill or is stopped. "Routine Maintenance and Repair". 890SD Standalone Drive - Frames G, H & J Page 1-3 Safety WARNING! - Ignoring the following may result in injury or damage to equipment SAFETY Where there is conflict between EMC and Safety requirements, personnel safety shall always take precedence. • Never perform high voltage resistance checks on the • All control and signal terminals are SELV, i.e. protected wiring without first disconnecting the drive from the by double insulation. Ensure all external wiring is rated circuit being tested. for the highest system voltage. • Whilst ensuring ventilation is sufficient, provide guarding • Thermal sensors contained within the motor must have at and /or additional safety systems to prevent injury or least basic insulation. damage to equipment. • All exposed metalwork in the Inverter is protected by • When replacing a drive in an application and before basic insulation and bonded to a safety earth. returning to use, it is essential that all user defined • RCDs are not recommended for use with this product but, parameters for the product’s operation are correctly where their use is mandatory, only Type B RCDs should installed. be used. EMC • In a domestic environment this product may cause radio • This is a product of the restricted sales distribution class interference in which case supplementary mitigation according to IEC 61800-3. It is designated as measures may be required. “professional equipment” as defined in EN61000-3-2. • This equipment contains electrostatic discharge (ESD) Permission of the supply authority shall be obtained before connection to the low voltage supply. sensitive parts. Observe static control precautions when handling, installing and servicing this product. Page 1-4 890SD Standalone Drive - Frames G, H & J Safety CAUTION! APPLICATION RISK • The specifications, processes and circuitry described herein are for guidance only and may need to be adapted to the user’s specific application. We can not guarantee the suitability of the equipment described in this Manual for individual applications. RISK ASSESSMENT Under fault conditions, power loss or unintended operating conditions, the drive may not operate as intended. In particular: • Stored energy might not discharge to safe levels as • The motor's direction of rotation might not be controlled quickly as suggested, and can still be present even though the drive appears to be switched off • The motor speed might not be controlled • The motor might be energised A drive is a component within a drive system that may influence its operation or effects under a fault condition. Consideration must be given to: • Stored energy • Supply disconnects • Sequencing logic • Unintended operation 890SD Standalone Drive - Frames G, H & J Page 1-5 Getting Started Chapter 2 Getting Started A few things you should do when you first receive the unit. ♦ How the manual is organised ♦ Inspect the unit for transit damage ♦ Initial steps ♦ Packaging and lifting 890SD (Standalone) Drive: Frame G, H & J Page 2-1 Getting Started About this Manual IMPORTANT Motors used must be suitable for Inverter duty. Note Do not attempt to control motors whose rated current is less than 25% of the drive rated current. Poor motor control problems may occur if you do. This manual is intended for use by the installer, user and programmer of the 890 drive. It assumes a reasonable level of understanding in these three disciplines. Note Please read all Safety information before proceeding with the installation and operation of this unit. It is important that you pass this manual on to any new user of this unit. How the Manual is Organised This Engineering Reference manual is organised into chapters, indicated by the numbering on the edge of each page. The manual is more detailed than the relevant QuickStart manual, and so is of use to the unfamiliar as well as the high-end user. Page 2-2 890SD (Standalone) Drive: Frame G, H & J

Description:
Note Metal surfaces such as eloxized or yellow chromed (e.g. cable mounting or 35mm DIN rails, screws and bolts) have Having turned the motor for the first time, now learn about the various ways you can start and stop the drive. Re-connect 4-way op-station cable to LED PCB (see figure 10.1). 7.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.