85 Plasma arc cutting systems Operator Manual – 806650 Revision 1 Register your new Hypertherm system Register your product on-line at www.hypertherm.com/registration for easier technical and warranty support. You can also receive updates on new Hypertherm products and a free gift as a token of our appreciation. For your records Serial number: ______________________________________________________ Purchase date: ______________________________________________________ Distributor: ______________________________________________________ ___________________________________________________________________ ___________________________________________________________________ Maintenance notes: ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ powermax 65 powermax 85 Operator Manual (P/N 806650) Revision 1 – November 2010 Hypertherm, Inc. Hanover, NH USA www.hypertherm.com email: [email protected] © Copyright 2010 Hypertherm, Inc. All Rights Reserved Hypertherm and Powermax are trademarks of Hypertherm, Inc. and may be registered in the United States and/or other countries. Hypertherm, Inc. Hypertherm Europe B.V. Etna Road, P.O. Box 5010 Vaartveld 9 Hanover, NH 03755 USA 4704 SE 603-643-3441 Tel (Main Office) Roosendaal, Nederland 603-643-5352 Fax (All Departments) 31 165 596907 Tel [email protected] (Main Office Email) 31 165 596901 Fax 800-643-9878 Tel (Technical Service) 31 165 596908 Tel (Marketing) [email protected] (Technical Service Email) 31 165 596900 Tel (Technical Service) 800-737-2978 Tel (Customer Service) 00 800 4973 7843 Tel (Technical Service) [email protected] (Customer Service Email) Hypertherm Japan Ltd. Hypertherm Automation Level 9, Edobori Center Building 5 Technology Drive, Suite 300 2-1-1 Edobori, Nishi-ku West Lebanon, NH 03784 USA Osaka 550-0002 Japan 603-298-7970 Tel 81 6 6225 1183 Tel 603-298-7977 Fax 81 6 6225 1184 Fax Hypertherm Plasmatechnik GmbH Hypertherm Brasil Ltda. Technologiepark Hanau Avenida Doutor Renato de Rodenbacher Chaussee 6 Andrade Maia 350 D-63457 Hanau-Wolfgang, Deutschland Parque Renato Maia 49 6181 58 2100 Tel CEP 07114-000 49 6181 58 2134 Fax Guarulhos, SP Brasil 49 6181 58 2123 (Technical Service) 55 11 2409 2636 Tel 55 11 2408 0462 Fax Hypertherm (S) Pte Ltd. 82 Genting Lane Hypertherm México, S.A. de C.V. Media Centre Avenida Toluca No. 444, Anexo 1, Annexe Block #A01-01 Colonia Olivar de los Padres Singapore 349567, Republic of Singapore Delegación Álvaro Obregón 65 6841 2489 Tel México, D.F. C.P. 01780 65 6841 2490 Fax 52 55 5681 8109 Tel 65 6841 2489 (Technical Service) 52 55 5683 2127 Fax Hypertherm (Shanghai) Trading Co., Ltd. Unit A, 5th Floor, Careri Building 432 West Huai Hai Road Shanghai, 200052 PR China 86-21 5258 3330/1 Tel 86-21 5258 3332 Fax 12/17/09 ELECTROMAGNETIC COMPATIBILITY (EMC) EMC Introduction b. Radio and television transmitters and receivers. Hypertherm’s CE-marked equipment is built in c. Computer and other control equipm ent. compliance with standard EN60974-10. The equipment should be in stalled and used in d. Safety critical equipment, for example accordance with the information be low to guarding of industrial equipment. achieve elect ro mag net ic com pat i bili ty. e. Health of the people around, for example the use of pacemakers and heari ng aids. The limits required by EN60974-10 may not beadequate to com plete ly eliminate in ter fer - f. Equipment used for calibration or ence whenthe affected equipm ent is in close measurement. proximity orhas a high degree of sens i tivity. g. Immunity of other equipment in the Insuch cases itmay be nec es sary to use other environment. User shall ensure that other mea sures to furtherre duce interference. equipment being used in the environment is com pat i ble. This may require ad di tion al This cutting equipment is designed for use protection measures. onlyin an in dus tri al environment. h. Time of day that cutting or other act iv i ties are to be carried out. Installation and use The user is responsible for installing and The size of the surr ound ing area to be con- usingtheplasma equipment according to the sidered will depend on the structure of the manufacturer’s instructions. If elect ro mag net ic building and other activities that are tak ing disturbances are de tect ed then it shall be the place. The surrounding area may ext end respon si bili ty of the user to res olve the beyond the bound aries of the prem ises. situation withthe technical as sist ance of the man u fac tur er. Insome cases this remedial Methods of reducing action may be as sim ple as earthing the emissions cuttingcircuit, see Earthingof Workpiece. Inother cas es it could involve constructing an Mains supply electromag net ic screen enclosing the powe r Cutting equipment must be conn ect ed to the source and the work complete with associated mains supply according to the manu fac tur er’s input filters. In all cases elect ro mag net ic recom men da tions. If in ter fer ence occurs, it may disturbance s must be reduced to the point be necessary to take addit ional precautions where they are no longer troub le some. such as filt er ing of the mains supply. Consideration should be given to shieldi ng the Assessment of area supply cable of perm a nent ly installed cutting Before installing the equipment the user shall equipm ent, in metallic conduit or equiva lent. make an assessment of po ten tial electro- Shielding should beelec tri cal ly continuous magnet ic problems in the surr ound ing area. through out its length. The shielding should The following shall be taken into account: becon nect ed to the cutting mains supply so that good electrical contact is maintained a. Other supply cables, control cables, between the conduit and the cutting powe r signalling and telephone cab les; above, source enclosure. below and adjacent to the cutting equipment. powermax65/85 Operator Manual i Hypertherm i 4-08 TEALbECleTR OOFM CAOGNNTEeTNICTS COMPATIBILITY (EMC) Maintenance of cutting equipment workpiece to earth should be made by a direct connection to the work piece, but in some The cutting equipment must be rou tine ly countries where direct connection is not maintained according to the man u fac tur er’s permitted, the bonding should be achieved by recom men da tions. All ac cess and service doors suit able capacitances se lect ed according to and covers should be closed and properly national regulations. fastened when the cutting equip ment is in operation. The cutting equipment should not be Note: the cutting circuit may or may not be modified in any way except for those chang es earthed for safety reasons. Changing the and ad just ments covered in the manufac tur er’s earthing arrangements should only be instructions. In par tic u lar, the spark gaps of arc authorized by a person who is comp e tent to striking and sta bi liz ing devices should be assess whether the chang es will in crease the adjusted and maintained according to the risk of injury, for example, by al low ing parallel manu fac tur er’s recommendations. cutting cur rent return paths which may damage the earth cir cuits of other equipment. Further Cutting cables guida nce is given in IEC/ TS 62081 Arc Welding Equipm ent Installation and Use. The cutting cables should be kept as short aspossible and should be po si tioned close together, running at or close to the floor level. Screening and shielding Selective screening and shielding of other Equipotential bonding cables and equipment in the surrounding area may alleviate problems of in ter fer ence. Bonding of all metallic components in the Screening of the entire plasm a cutting cutting installation and adjacent to it should be installation may be cons ide red for special considered. However, metallic comp o nents applications. bonded to the workpiece will increase the risk that the op er a tor could receive a shock by touch ing these metallic compon ents and the electrode(nozzle for laser heads) at the same time. The op er a tor should be in su lat ed from all such bonded metallic components. Earthing of workpiece Where the workpiece is not bonded to earth for electrical safety, nor connected to earth because of its size and position, for ex am ple, ship’s hull or building steel work, a conn ec tion bonding the work piece to earth may reduce emis sions in some, but not all instances. Careshould be takento prevent the earthing ofthe work piece increasing the risk of injury to users, or damage to other elect ri cal equipm ent. Where necessary, the con nec tion of the ii powermax65/85 Operator Manual ii Hypertherm 4-08 TAble OF WCAORNRTeANNTTSY Attention costs, insurance and freight pre paid. Hypertherm shall not be liable for any repairs, Genuine Hypertherm parts are the factory- replacement, or adjustments of Products recommended replacement parts for your covered by this war ranty, except those made Hypertherm system. Any damage caused by the pursuant to this paragraph or with Hypertherm’s use of other than genuine Hypertherm parts may prior written consent. Thewarranty above is not be covered by the Hypertherm warranty. exclusive and is in lieu of all other You are responsible for the safe use of the warranties, express, implied, statutory, or Product. Hypertherm does not and cannot make otherwise with respect to the Products or any guarantee or warranty regarding the safe as to the results which may be obtained use of the Product in your environment. therefrom, and all implied warr anties or conditions of quality or of merchantability General or fitness for a particular purpose or Hypertherm, Inc. warrants that its Products shall against infringement. The foregoing shall be free from defects in materials and workman - constitute the sole and exclusive remedy ship, if Hypertherm is notified of a defect (i) with for any breach by Hypertherm of its respect to the power supply within a period of warranty.Distributors/OEMs may offer different two (2) years from the date of its delivery to you, or additional warranties, but Distributors/OEMs with the exception of Powermax brand power are not authorized to give any additional supplies, which shall be within a period of three warranty protection to you or make any (3) years from the date of delivery to you, and representation to you purporting to be binding (ii)with respect to the torch and leads within a upon Hypertherm. period of one (1) year from its date of delivery to you, and with respect to torch lifter assemblies Certification test marks within a period of one (1) year from its date of Certified products are identified by one or more delivery to you, and with respect to laser heads certification test marks from accredited testing within a period of one (1) year from its date of laboratories. The certification test marks are delivery to you. This warranty shall not apply to located onor near the data plate. Each any Powermax brand power supplies that have certification test mark means that the product been used with phase converters. In addition, and its safety-critical components conform to Hypertherm does not warranty systems that the relevant national safety standards as have been damaged as a result of poor power reviewed by that testing laboratory. Hypertherm quality, whether from phase converters or places a certification test mark on its products incoming line power. This warranty shall not only after that product is manufactured with apply to any Product which has been incorrectly safety-critical components that have been installed, modified, or otherwise damaged. authorized bythe accredited testing laboratory. Hypertherm, at its sole option, shall repair, Once the product has left the Hypertherm replace, or adjust, free of charge, any defective factory, the certification test marks are Products covered by this warranty which shall invalidated if any of the following occurs: be returned with Hypertherm’s prior • The product is significantly modified authorization (which shall not be unreasonably inamanner that creates a hazard or withheld), properly packed, to Hypertherm’s non-conformance. place of business in Hanover, New Hampshire, • Safety-critical components are replaced with or to an authorized Hypertherm repair facility, all unauthorized spare parts. powermax65/85 Operator Manual iii Hypertherm iii 4-08 WTAAbRlReA ONFT YCONTeNTS • Any unauthorized assembly or accessory that It is important that the product and its uses or generates a hazardous voltage is certification test mark be suitable for the end- added. use installation site. When Hypertherm • There is any tampering with a safety circuit or products are shipped to one country for export other feature that is designed into the product to another country, the product must be as part of the certification. configured and certified properly for the end- use site. CE marking constitutes a manufacturer’s declaration of conformity to applicable European Higher-level systems directives and standards. Only those versions of Hypertherm products with a CE Marking located When a system integrator adds additional on or near the data plate have been tested for equipment; such as cutting tables, motor drives, compliance with the European Low Voltage motion controllers or robots; to a Hypertherm Directive and the European EMC Directive. plasma cutting system, the combined system EMCfilters needed to comply with the European may be considered a higher-level system. A EMC Directive are incorporated within versions higher-level system with hazardous moving parts of the power supply with a CE Marking. may constitute industrial machinery or robotic equipment, in which case the OEM or end-use customer may be subject to additional Differences in National Standards regulations and standards than those relevant to Differences in standards include, but are not the plasma cutting system as manufactured by limited to: Hypertherm. • Voltages It is the responsibility of the end-use customer • Plug and cord ratings and the OEM to perform a risk assessment for • Language requirements the higher-level system and to provide • Electromagnetic compatibility requirements protection against hazardous moving parts. Unless the higher-level system is certified when These differences in national standards may the OEM incorporates Hypertherm products make it impossible or impractical for all into it, the installation also may be subject to certification test marks to be placed on the approval by local authorities. Seek advice from same version of a product. For example, the legal counsel and local regulatory experts if CSA versions of Hypertherm’s products do not uncertain about compliance. comply with European EMC requirements and they do not have a CE marking on the data External interconnecting cables between plate. component parts of the higher level system must be suitable for contaminants and Countries that require CE marking or have movement as required by the final end-use compulsory EMC regulations must use CE installation site. When the external inter- versions of Hypertherm products with the CE connecting cables are subject to oil, dust, or marking on the data plate. These include: water contaminants, hard usage ratings may be • Australia required. When external interconnecting cables are subject to continuous movement, constant • New Zealand flexing ratings may be required. It is the • Countries in the European Union responsibility of the end-use customer or the • Russia OEM to ensure the cables are suitable for the application. Since there are differences in the iv powermax65/85 Operator Manual iv Hypertherm 4-08 TAble OF WCAORNRTeANNTTSY ratings and costs that can be required by use of the Products exceed in the aggregate localregulations for higher-level systems, the amount paid for the Products that gave itisnecessary to verify that any external rise to such claim. interconnecting cables are suitable for the Insurance end-use installation site. At all times you will have and maintain insurance Patent indemnity in such quantities and types, and with coverage Except only in cases of products not sufficient and appropriate to defend and to hold manufactured by Hypertherm or manufactured Hypertherm harmless in the event of any cause by a person other than Hypertherm not in strict of action arising from the use of the Products. conformity with Hypertherm’s specifications and National and Local codes in cases of designs, processes, formulae, or combinations not developed or purported to be National and Local codes governing plumbing developed by Hypertherm, Hypertherm will and electrical installation shall take precedent defendor settle, at its own expense, any suit or over any instructions contained in this manual. proceeding brought against you alleging that the Inno eventshall Hypertherm be liable for injury use of the Hypertherm product, alone and not in to persons or property damage by reason of combination with any other product not supplied anycode violation or poor work practices. by Hypertherm, infringes any patent of any third party. You shall notify Hypertherm promptly upon Transfer of rights learning of any action or threatened action in You may transfer any remaining rights you may connection with any such alleged infringement, have hereunder only in connection with the sale and Hypertherm’s obligation to indemnify shall of all or substantially all of your assets or capital be conditioned upon Hypertherm’s sole control stock to a successor in interest who agrees to of, and the indemnified party’s cooperation and be bound by all of the terms and conditions of assistance in, the defense of the claim. this Warranty. Limitation of liability Proper disposal of In no event shall Hypertherm be liable to Hypertherm products anyperson or entity for any incidental, consequential, indirect, or punitive damages Hypertherm plasma cutting systems, like all (including but not limited to lost profits) electronic products, may contain materials or regardless of whether such liability is based components, such as printed circuit boards, that on breach of contract, tort, strict liability, cannot be discarded with ordinary waste. It is breach of warranties, failure of essential your responsibility to dispose of any Hypertherm purpose or otherwise and even if advised product or component part in an environmentally ofthe possibility of such damages. acceptable manner according to national and local codes. Liability cap • In the United States, check all federal, state, In no event shall Hypertherm’s liability, and local laws. whether such liability is based on breach • In the European Union, check the EU ofcontract, tort, strict liability, breach of directives, national, and local laws. For more warranties, failure of essential purpose or information, visit www.hypertherm.com/weee. otherwise, for any claim action suit or proceeding arising out of or relating to the • In other countries, check national and local laws. powermax65/85 Operator Manual v Hypertherm v 4-08 TWAAbRlReA ONFT YCONTeNTS vi powermax65/85 Operator Manual vi Hypertherm
Description: