ebook img

Planning Instructions Fire Alarm System EBL512 G3 V2.2.x PDF

205 Pages·2015·4.03 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Planning Instructions Fire Alarm System EBL512 G3 V2.2.x

Planning Instructions MEW01776 Revision - Fire Alarm System EBL512 G3 V2.2.x Author: Jan Pettersson Date of issue: 2015-01-19 Date of rev: This page has deliberately been left blank. Panasonic Eco Solutions Nordic AB MEW01776 Rev: - Planning Instructions Fire alarm system EBL512 G3, V2.2.x Table of contents 1 Introduction________________________________ 9 2 Definitions / Explanations ___________________ 11 2.1 PESN AB _______________________________________ 11 2.2 Alarm points _____________________________________ 11 2.2.1 Smoke detector _______________________________ 11 2.2.2 Sensor ______________________________________ 11 2.2.3 Analog detector _______________________________ 11 2.2.4 Analog Sensor Base (ASB) ______________________ 11 2.2.5 Conventional detector __________________________ 11 2.2.6 Conventional Detector Base (CDB) _______________ 11 2.2.7 Addressable __________________________________ 12 2.2.8 Conventional zone line input / External line _________ 12 2.3 Output unit ______________________________________ 12 2.4 Output / Control output _____________________________ 12 2.5 Short circuit isolator (ISO) __________________________ 12 2.6 Display unit (D.U.) ________________________________ 12 2.7 COM loop _______________________________________ 12 2.8 Control Unit / C.U. / C.I.E. __________________________ 12 2.9 Fire Brigade Panel (FBP) ___________________________ 12 2.10 Control panel (CP) ________________________________ 13 2.11 System / Installation _______________________________ 13 2.12 Network / TLON® / LonWorks® / Echelon / Node / TLON Conn. board / Channel / Backbone net / Router / Repeater _______ 13 2.13 LED ____________________________________________ 13 2.14 External Indicator (Ext. LED) ________________________ 13 2.15 Display / LCD ____________________________________ 14 2.16 Door open (Door / Key switch) _______________________ 14 2.17 Site Specific Data (SSD) ____________________________ 14 2.18 Software (S/W) / Firmware / System program ___________ 14 2.19 EBLWin ________________________________________ 14 2.20 Web-server ______________________________________ 14 2.21 EN54-13 ________________________________________ 14 3 Overview _________________________________ 15 3.1 The EBL512 G3 system ____________________________ 15 3.1.1 Printer ______________________________________ 15 3.1.2 Expansion boards _____________________________ 15 3.1.3 Power supply _________________________________ 16 3.2 Software (S/W) versions ____________________________ 16 3.3 Documents ______________________________________ 16 3.4 Applications _____________________________________ 16 3.5 PC programs _____________________________________ 16 3.5.1 EBLWin ____________________________________ 16 1 Panasonic Eco Solutions Nordic AB MEW01776 Rev: - Planning Instructions Fire alarm system EBL512 G3, V2.2.x 3.5.2 TLON Manager _______________________________ 17 4 Control Unit / TLON Network _______________ 18 4.1 The TLON Network _______________________________ 18 4.2 Single TLON Network / Redundant TLON Network ______ 18 5 Control Units 5000 and 5001 _________________ 20 5.1 Mounting plates ___________________________________ 23 5.1.1 Mounting plate for 19" mounting rack, 5020 ________ 23 5.1.2 Mounting plate for inflammable wall, 5021 _________ 23 5.2 COM loops ______________________________________ 23 5.3 Programmable voltage outputs (S0-S3) ________________ 24 5.4 Programmable relay outputs (R0-R1) __________________ 24 5.5 Programmable inputs (I0-I3) _________________________ 24 5.6 Relay outputs for routing equipment (tx) _______________ 25 5.6.1 Fire alarm output ______________________________ 25 5.6.2 Fault condition output __________________________ 25 6 Expansion boards 458x _____________________ 26 6.1 Expansion board no. (address) setting __________________ 27 6.2 8 zones expansion board 4580 _______________________ 27 6.2.1 Type of zone line input _________________________ 28 6.2.2 Input states __________________________________ 28 6.3 8 relays expansion board 4581 _______________________ 29 6.4 Inputs and outputs expansion board 4583 _______________ 30 6.5 Inputs and outputs expansion board 4583DE ____________ 31 6.6 I/O Matrix board 4582 _____________________________ 33 6.6.1 Generic _____________________________________ 34 6.6.2 Fan control __________________________________ 34 6.6.3 Zone control _________________________________ 35 7 Printer ___________________________________ 36 7.1 EBL512 G3 ______________________________________ 36 7.2 Ext. Fire Brigade Panel 1826 ________________________ 36 8 TLON connection board 5090 ________________ 37 8.1 Single TLON Network _____________________________ 37 8.2 Redundant TLON network __________________________ 37 8.3 Network programming _____________________________ 37 9 Peripheral devices __________________________ 38 9.1 COM loop units ___________________________________ 38 9.1.1 Input units ___________________________________ 40 9.1.2 Addressable I/O units __________________________ 53 9.1.3 Alarm devices (addressable sounders) _____________ 55 9.1.4 Short circuit isolators (addressable) _______________ 57 9.1.5 Built-in isolators ______________________________ 59 9.1.6 Units for Hazardous (Ex) areas ___________________ 59 9.1.7 Other COM loop units __________________________ 60 9.1.8 Obsolete units ________________________________ 62 2 Panasonic Eco Solutions Nordic AB MEW01776 Rev: - Planning Instructions Fire alarm system EBL512 G3, V2.2.x 9.2 Units connected to the RS485 interface ________________ 62 9.2.1 External Fire Brigade Panels _____________________ 63 9.2.2 Alert Annunciation Units _______________________ 64 9.2.3 External Presentation Units ______________________ 65 9.2.4 German Fire Brigade Panels - Schraner ____________ 66 9.2.5 Swiss Fire Brigade Panel - IFAM _________________ 67 9.2.6 German Fire Brigade Panels - IFAM ______________ 68 9.3 Units connected to the RS232 interface J7 ______________ 68 9.3.1 Web-servers __________________________________ 68 9.4 Other units _______________________________________ 69 9.4.1 Alert Annunciation Controllers ___________________ 69 9.4.2 External LED ________________________________ 70 9.4.3 Alarm devices (sounders, etc.) ___________________ 70 9.4.4 Door release magnets __________________________ 70 9.4.5 Boxes _______________________________________ 71 9.4.6 Duct detector chambers _________________________ 71 9.4.7 German key cabinet ____________________________ 71 10 Programmable inputs _______________________ 72 10.1 Control unit Inputs I0 - I3 ___________________________ 72 10.2 Inputs 0 - 4 on exp. board 4583 _______________________ 72 10.2.1 Not supervised ________________________________ 72 10.2.2 Supervised ___________________________________ 72 10.3 Inputs 0 - 4 on exp. board 4583DE ____________________ 73 10.3.1 Not supervised ________________________________ 73 10.3.2 Supervised ___________________________________ 73 10.4 The 3361 unit's Inputs In0 / Z & In1 ___________________ 74 10.4.1 Input In0 ____________________________________ 74 10.4.2 Input In1 ____________________________________ 74 11 Input programming ________________________ 75 11.1 Trigger conditions _________________________________ 75 11.2 Logic ___________________________________________ 78 11.2.1 Supervised ___________________________________ 79 12 Programmable outputs ______________________ 80 12.1 Control unit outputs S0 – S3 _________________________ 81 12.2 Control unit outputs R0 & R1 ________________________ 82 12.3 8 relays expansion board 4581 Output 0 – Output 7 _______ 82 12.4 Inputs and Outputs expansion board 4583 Output 0 & Output 182 12.5 Inputs and Outputs expansion board 4583DE Output 0 & Output 1 _______________________________________________ 82 12.6 The 3361 unit's Outputs Re0 & Re1 ___________________ 83 12.7 The 3364 unit's VO0 – VO2 _________________________ 83 12.8 The 3377 / 4477 unit's Output (siren) __________________ 83 12.9 The 3379 unit's Output (sounder) _____________________ 84 12.10 The 4380 unit's Output (beacon) ____________________ 84 12.11 The 4383 unit's Output (light) ______________________ 84 3 Panasonic Eco Solutions Nordic AB MEW01776 Rev: - Planning Instructions Fire alarm system EBL512 G3, V2.2.x 12.12 The 4611 wireless smoke detector Output (sounder) ____ 84 13 Output programming _______________________ 85 13.1 Type of output ____________________________________ 85 13.2 Logic ___________________________________________ 86 13.3 Supervised / Not supervised _________________________ 86 13.4 Output signal period _______________________________ 86 13.5 Control expression ________________________________ 89 13.5.1 Trigger conditions _____________________________ 89 13.5.2 Logical operators ______________________________ 96 13.5.3 Control expression examples ____________________ 96 14 Short circuit isolators ______________________ 101 15 Interlocking function ______________________ 104 15.1 Programming of interlocking function ________________ 104 15.1.1 Interlocking output ___________________________ 104 15.1.2 Interlocking input ____________________________ 104 15.1.3 Interlocking combination ______________________ 104 15.2 Interlocking indications ____________________________ 106 15.3 Interlocking outputs and inputs (H9) _________________ 106 15.3.1 Activated interlocking outputs / inputs (H9/C1) _____ 106 15.3.2 Activate / deactivate interlocking output (H9/C2) ___ 107 15.3.3 Disable / re-enable interlocking output (H9/C3) _____ 107 15.4 Interlocking control expressions _____________________ 107 16 Fire Door Closing _________________________ 108 17 Functions / Services / Features ______________ 109 17.1 Sensor value ____________________________________ 109 17.2 Week average sensor value _________________________ 109 17.3 Decision value ___________________________________ 110 17.4 Alarm algorithms for smoke detectors / Detection levels / Offsets 110 17.4.1 Alarm algorithm / Alternative alarm algorithm _____ 111 17.4.2 Filtering algorithm ___________________________ 112 17.4.3 Smouldering smoke algorithm __________________ 114 17.4.4 Performance factor ___________________________ 115 17.5 Algorithms for analog heat detectors _________________ 116 17.5.1 Class A1 algorithm ___________________________ 116 17.5.2 Class A2 S algorithm _________________________ 117 17.5.3 Class B S algorithm ___________________________ 117 17.6 Self verification __________________________________ 117 17.7 Minimum / Maximum sensor values __________________ 118 17.8 2-zone / 2-address dependence (Co-incidence alarm) _____ 119 17.8.1 2-zone dependence ___________________________ 119 17.8.2 2-address (-unit) dependence ___________________ 120 17.8.3 Reset of 2-zone / 2-address dependence (co-incidence alarm 120 17.9 Delayed alarm ___________________________________ 121 4 Panasonic Eco Solutions Nordic AB MEW01776 Rev: - Planning Instructions Fire alarm system EBL512 G3, V2.2.x 17.10 Selective Alarm Presentation _____________________ 121 17.11 Alarm Verification Facility _______________________ 121 17.12 Alert Annunciation _____________________________ 122 17.13 Local Alarm Acknowledgement (LAA) _____________ 124 17.14 Quiet alarm ___________________________________ 126 17.15 Fire alarm type A and Fire alarm type B _____________ 126 17.15.1 Fire alarm type B ___________________________ 127 17.15.2 Fire alarm type A __________________________ 127 17.16 Disable alarm points and outputs __________________ 127 17.16.1 Disable zone ______________________________ 128 17.16.2 Disable zone / address _______________________ 128 17.16.3 Disable control output _______________________ 128 17.16.4 Disable / Re-enable output type _______________ 128 17.16.5 Disable / Re-enable alarm devices _____________ 128 17.17 Disable interlocking output _______________________ 129 17.18 Disable outputs for routing equipment ______________ 129 17.19 Disconnect & Re-connect loop / zone line input _______ 129 17.20 External time channels __________________________ 129 17.21 Test mode ____________________________________ 129 17.22 Test alarm devices ______________________________ 130 17.23 Test of outputs _________________________________ 130 17.24 Test of routing equipment ________________________ 130 17.25 Calibration of supervised outputs __________________ 131 17.26 Service signal _________________________________ 131 17.27 Fault signal (fault condition) ______________________ 131 17.28 Alarm texts ___________________________________ 132 17.28.1 Creating the alarm texts via EBLWin ___________ 132 17.28.2 Downloading alarm texts to the DU:s 1728 / 1735 / 1736 and ext. FBP:s 1826 / 1828 ________________________ 134 17.29 Real time clock (RTC) __________________________ 134 17.29.1 Daylight saving time ________________________ 134 17.30 Loss of main power source _______________________ 135 17.30.1 Fault: Loss of main power source ______________ 135 17.30.2 LCD backlight _____________________________ 135 17.31 Evacuate _____________________________________ 135 17.32 Zone groups ___________________________________ 135 18 Special New Zealand functions ______________ 137 19 Advanced mode ___________________________ 138 19.1 Pulse up – down counter ___________________________ 139 19.1.1 Pulse up – down counter for smoke ______________ 139 19.1.2 Pulse up – down counter for temperature __________ 140 19.1.3 Pulse up – down counter for smoke & temperature __ 140 19.2 Fire judgement __________________________________ 140 19.3 Alarm threshold levels ____________________________ 140 19.4 Alarm delay time _________________________________ 141 5 Panasonic Eco Solutions Nordic AB MEW01776 Rev: - Planning Instructions Fire alarm system EBL512 G3, V2.2.x 19.5 Learning function / Learning period __________________ 142 19.5.1 Area Alarm algorithms ________________________ 142 19.6 Analog data output _______________________________ 144 19.7 Sensitivity compensation __________________________ 144 19.8 Self diagnosis of internal devices ____________________ 145 19.9 Address setting check _____________________________ 145 19.10 Polling LED __________________________________ 145 20 Control unit properties ____________________ 146 20.1 Control unit properties dialog box ___________________ 146 20.1.1 General Information __________________________ 146 20.1.2 Peripherals __________________________________ 146 20.1.3 Misc. ______________________________________ 146 20.2 EBLWin Control unit pop-up menu __________________ 147 20.2.1 Reset alarm counter ___________________________ 147 20.2.2 Software version _____________________________ 148 20.2.3 Upgrade number of alarm points _________________ 148 20.2.4 Show event log ______________________________ 148 20.2.5 Restart _____________________________________ 149 20.2.6 Delete _____________________________________ 149 20.2.7 Properties___________________________________ 149 20.2.8 Add Web-server _____________________________ 149 21 System properties (settings) _________________ 150 21.1 System properties dialog box _______________________ 150 21.1.1 Name ______________________________________ 150 21.1.2 User definable text ___________________________ 150 21.1.3 System properties, Page 1 ______________________ 150 21.1.4 System properties, Page 2 ______________________ 152 22 EBLWin menus ___________________________ 154 22.1 The File menu ___________________________________ 154 22.1.1 New _______________________________________ 154 22.1.2 Open ______________________________________ 154 22.1.3 Import from Win512 __________________________ 154 22.1.4 Report _____________________________________ 154 22.1.5 Save _______________________________________ 155 22.1.6 Save As ____________________________________ 155 22.1.7 Print labels __________________________________ 155 22.2 The View menu __________________________________ 155 22.2.1 Tree view ___________________________________ 155 22.2.2 Deviations __________________________________ 156 22.2.3 Selected loop ________________________________ 156 22.2.4 Alarm points ________________________________ 156 22.2.5 Interlocking combinations ______________________ 157 22.2.6 External faults _______________________________ 157 22.2.7 Technical warnings ___________________________ 157 22.2.8 External time channels ________________________ 158 6 Panasonic Eco Solutions Nordic AB MEW01776 Rev: - Planning Instructions Fire alarm system EBL512 G3, V2.2.x 22.3 The System menu ________________________________ 158 22.3.1 Properties___________________________________ 158 22.3.2 Time channels _______________________________ 158 22.3.3 Alarm algorithms ____________________________ 160 22.3.4 Output Signal Periods _________________________ 162 22.3.5 National holidays ____________________________ 163 22.3.6 Two zone dependence _________________________ 164 22.3.7 Zone groups _________________________________ 165 22.3.8 System information ___________________________ 166 22.3.9 Edit Alarm texts _____________________________ 166 22.3.10 User data _________________________________ 166 22.4 The Tools menu__________________________________ 168 22.4.1 Web-server _________________________________ 169 23 Download SSD ____________________________ 171 23.1 COM loop menu _________________________________ 172 23.1.1 Check Loop _________________________________ 172 23.1.2 Auto generate loop ___________________________ 172 23.2 Single Control Unit _______________________________ 173 23.3 Control Units in a TLON network ___________________ 173 23.4 User definable text messages download _______________ 173 24 Download software (S/W) __________________ 174 24.1 Single control unit (c.i.e.) __________________________ 174 24.2 Control Units in a TLON network ___________________ 176 25 Compatibility_____________________________ 177 26 Cable types ______________________________ 178 26.1 TLON Network cables ____________________________ 178 26.2 COM loop cables_________________________________ 178 26.3 Ext. FBP / Display Units cables _____________________ 178 26.4 Conventional zone line cables _______________________ 178 26.5 Alarm device cables ______________________________ 179 26.6 Other cables _____________________________________ 179 27 COM loop cable length _____________________ 180 28 Current consumption ______________________ 183 29 Power supply _____________________________ 188 29.1 Charger functions ________________________________ 189 29.1.1 Charging ___________________________________ 189 29.1.2 Battery charging functions: _____________________ 189 29.1.3 Security functions ____________________________ 189 29.2 Current consumption calculations ____________________ 190 29.3 Power supply (rectifier) - main power source ___________ 191 29.4 Battery - second power source ______________________ 191 29.5 Fuses __________________________________________ 192 29.6 Form / Table of current consumption _________________ 193 30 S/W versions _____________________________ 194 7 Panasonic Eco Solutions Nordic AB MEW01776 Rev: - Planning Instructions Fire alarm system EBL512 G3, V2.2.x 31 Technical data ____________________________ 195 32 Limitations_______________________________ 196 32.1 User definable texts _______________________________ 196 32.2 C.i.e. / System ___________________________________ 196 33 National regulations _______________________ 198 34 Drawings / connection diagrams _____________ 199 35 Revision history ___________________________ 200 Drawings according to the valid table of drawings. 8

Description:
units. The TLON Network makes it possible to install the control units in one building or in different buildings. 3.5. PC programs. The following PC programs are used together with the EBL512 G3 system. 3.5.1. EBLWin. The PC program EBLWin is used for programming and commissioning of one or
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.