Planning Instructions MEW01472 Revision - Fire Alarm System EBL512 G3 United version 2.7.x Author: Jan Pettersson Date of issue: 2012-04-05 Date of rev: This page has deliberately been left blank. Panasonic Eco Solutions Nordic AB MEW01472 Rev: - Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x Table of contents 1 Introduction________________________________ 9 2 Definitions / Explanations ___________________ 11 2.1 PEWN AB _______________________________________ 11 2.2 Alarm points _____________________________________ 11 2.2.1 Smoke detector _______________________________ 11 2.2.2 Sensor ______________________________________ 11 2.2.3 Analog detector _______________________________ 11 2.2.4 Analog (Sensor) Base (ASB) ____________________ 11 2.2.5 Conventional detector __________________________ 11 2.2.6 (Conventional Detector) Base (CDB) ______________ 11 2.2.7 Addressable __________________________________ 11 2.2.8 Conventional zone line input / External line _________ 12 2.3 Output unit ______________________________________ 12 2.4 Output / Control output _____________________________ 12 2.5 Short circuit isolator (ISO) __________________________ 12 2.6 Display unit (D.U.) ________________________________ 12 2.7 COM loop _______________________________________ 12 2.8 Control Unit / C.U. / C.I.E. __________________________ 12 2.9 Fire Brigade Panel (FBP) ___________________________ 12 2.10 Control panel (CP) ________________________________ 12 2.11 System __________________________________________ 12 2.12 Network / TLON® / LonWorks® / Echelon / Node / TLON Conn. board / Channel / Backbone net / Router / Repeater _______ 13 2.13 LED ____________________________________________ 13 2.14 External Indicator (Ext. LED) ________________________ 13 2.15 Display / LCD ____________________________________ 13 2.16 Door open (Door / Key switch) _______________________ 13 2.17 Site Specific Data (SSD) ____________________________ 14 2.18 Software (S/W) / System program ____________________ 14 2.19 Mixed system ____________________________________ 14 3 Overview _________________________________ 15 3.1 The EBL512 G3 system ____________________________ 15 3.1.1 Printer ______________________________________ 15 3.1.2 Expansion boards _____________________________ 15 3.1.3 Power supply _________________________________ 15 3.2 S/W versions _____________________________________ 16 3.3 Documents ______________________________________ 16 3.4 Applications _____________________________________ 16 3.5 PC software (S/W) ________________________________ 16 3.5.1 Win512 version 2.7.x __________________________ 16 3.5.2 WinG3 version 1.1.x ___________________________ 17 3.5.3 TLON Manager _______________________________ 17 1 Panasonic Eco Solutions Nordic AB MEW01472 Rev: - Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x 3.5.4 Web512 II Config Tool 2.7 ______________________ 17 4 Control Unit / TLON Network _______________ 18 4.1 The TLON network ________________________________ 18 4.2 Single TLON Network / Redundancy in distributed system _ 18 5 Control Units 5000 and 5001 _________________ 20 5.1 Mounting plates ___________________________________ 22 5.1.1 Mounting plate for 19" mounting rack, 5020 ________ 22 5.1.2 Mounting plate for inflammable wall, 5021 _________ 22 5.2 COM loops ______________________________________ 23 5.3 Programmable voltage outputs (S0-S3) ________________ 25 5.4 Programmable relay outputs (R0-R1) __________________ 25 5.5 Programmable inputs (I0-I3) _________________________ 25 5.6 Relay outputs for routing equipment (tx) _______________ 26 5.6.1 Fire alarm output ______________________________ 26 5.6.2 Fault condition output __________________________ 26 6 Expansion boards 458x _____________________ 27 6.1 Expansion board no. (address) setting __________________ 28 6.2 8 zones expansion board 4580 _______________________ 28 6.2.1 Type of detectors = Type of zone line input _________ 29 6.2.2 Input states __________________________________ 30 6.3 8 relays expansion board 4581 _______________________ 31 6.4 I/O Matrix board 4582 _____________________________ 31 6.4.1 Generic _____________________________________ 33 6.4.2 Fan control __________________________________ 33 6.4.3 Zone control _________________________________ 34 6.5 Inputs and outputs expansion board 4583 _______________ 34 6.6 External FBP / DU interface board 1587 _______________ 34 7 Printer ___________________________________ 35 8 TLON connection board 1590 ________________ 36 8.1 Single TLON Network _____________________________ 36 8.2 Network programming _____________________________ 36 9 Peripheral devices __________________________ 37 9.1 COM loop units ___________________________________ 37 9.1.1 Input units ___________________________________ 39 9.1.2 Addressable I/O units __________________________ 46 9.1.3 Alarm devices (addressable sounders) _____________ 48 9.1.4 Short circuit isolators (addressable) _______________ 49 9.1.5 Units for Hazardous (Ex) areas ___________________ 50 9.1.6 Other COM loop units __________________________ 51 9.2 Units connected to the RS485 interface ________________ 53 9.2.1 External Fire Brigade Panels _____________________ 53 9.2.2 Alert Annunciation Units _______________________ 55 9.2.3 External Presentation Units ______________________ 56 9.3 Units connected to the RS232 interface J7 ______________ 57 2 Panasonic Eco Solutions Nordic AB MEW01472 Rev: - Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x 9.3.1 Web-servers __________________________________ 57 9.4 Other units _______________________________________ 57 9.4.1 Alert Annunciation Controllers ___________________ 57 9.4.2 External LED ________________________________ 58 9.4.3 Alarm devices (sounders, etc.) ___________________ 58 9.4.4 Door release magnets __________________________ 58 9.4.5 Boxes _______________________________________ 59 9.4.6 Duct detector chambers _________________________ 59 10 Programmable inputs _______________________ 60 10.1 The 3361 unit's Inputs In0 / Z & In1 ___________________ 60 10.1.1 Input In0 ____________________________________ 60 10.1.2 Input In1 ____________________________________ 60 11 Input programming ________________________ 61 11.1 Trigger conditions _________________________________ 61 11.2 Logic ___________________________________________ 63 12 Programmable outputs ______________________ 64 12.1 Control unit outputs S0 – S3 _________________________ 65 12.2 Control unit outputs R0 & R1 ________________________ 65 12.3 8 relays expansion board 4581 Output 0 – Output 7 _______ 65 12.4 The 3361 unit's Outputs Re0 & Re1 ___________________ 66 12.5 The 3364 unit's VO0 – VO2 _________________________ 66 12.6 The 3377 unit's Output (siren) ________________________ 66 12.7 The 3379 unit's Output (sounder) _____________________ 66 12.8 The 4380 unit's Output (beacon) ______________________ 66 13 Output programming _______________________ 67 13.1 Type of output ____________________________________ 67 13.2 Logic ___________________________________________ 68 13.3 Supervised / Not supervised _________________________ 68 13.4 Time Activation Output ____________________________ 68 13.5 Control expression ________________________________ 71 13.5.1 Trigger conditions _____________________________ 71 13.5.2 Logical operators ______________________________ 75 13.5.3 Control expression examples ____________________ 75 14 Interlocking function _______________________ 79 14.1 Programming of interlocking function _________________ 79 14.1.1 Interlocking output ____________________________ 79 14.1.2 Interlocking input _____________________________ 79 14.1.3 Interlocking combination _______________________ 79 14.2 Interlocking indications _____________________________ 81 14.3 Information of interlocking combinations (H9) __________ 81 14.3.1 Display interlocking information (H9/C1) __________ 81 14.3.2 Activate interlocking output (H9/C2) ______________ 81 14.3.3 Reset interlocking output (H9/C3) ________________ 82 14.3.4 Disable interlocking output (H9/C4) _______________ 82 14.3.5 Re-enable interlocking output (H9/C5) _____________ 82 3 Panasonic Eco Solutions Nordic AB MEW01472 Rev: - Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x 14.4 Interlocking control expressions ______________________ 82 15 Fire Door Closing __________________________ 83 16 Functions / Services / Features _______________ 84 16.1 Sensor value _____________________________________ 84 16.2 Week average sensor value __________________________ 84 16.3 Decision value ____________________________________ 85 16.4 Alarm algorithms for smoke detectors / Detection levels / Offsets 85 16.4.1 Alarm algorithm / Alternative alarm algorithm ______ 86 16.4.2 Filtering algorithm ____________________________ 87 16.4.3 Smouldering smoke algorithm ___________________ 89 16.5 Performance factor ________________________________ 90 16.6 Algorithms for analog heat detectors __________________ 91 16.6.1 Class A1 algorithm ____________________________ 92 16.6.2 Class A2 S algorithm __________________________ 92 16.6.3 Class B S algorithm ____________________________ 92 16.7 Self verification ___________________________________ 92 16.8 Minimum / Maximum sensor values ___________________ 93 16.9 2-zone / 2-address dependence (Co-incidence alarm) ______ 94 16.9.1 2-zone dependence ____________________________ 94 16.9.2 2-address (-unit) dependence ____________________ 95 16.9.3 Reset of 2-zone / 2-address dependence (co-incidence alarm 95 16.10 Delayed alarm __________________________________ 96 16.11 Alarm Verification Facility ________________________ 96 16.12 Alert Annunciation ______________________________ 97 16.13 Alarm Acknowledgement Facility (AAF) _____________ 99 16.14 Quiet alarm ___________________________________ 101 16.15 Fire alarm type A and Fire alarm type B _____________ 101 16.15.1 Fire alarm type B ___________________________ 102 16.15.2 Fire alarm type A __________________________ 102 16.16 Disable alarm points and outputs __________________ 102 16.16.1 Disable zone ______________________________ 103 16.16.2 Disable zone / address _______________________ 103 16.16.3 Disable control output _______________________ 103 16.16.4 Disable / Re-enable output type _______________ 103 16.16.5 Disable / Re-enable alarm devices _____________ 103 16.17 Disable interlocking output _______________________ 103 16.18 Disable outputs for routing equipment ______________ 104 16.19 Disconnect & Re-connect loop / zone line input _______ 104 16.20 External time channels __________________________ 104 16.21 Test mode ____________________________________ 104 16.22 Test alarm devices ______________________________ 105 16.23 Test of routing equipment ________________________ 105 16.24 Calibration of supervised outputs __________________ 105 4 Panasonic Eco Solutions Nordic AB MEW01472 Rev: - Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x 16.25 Service signal _________________________________ 105 16.26 Fault signal (fault condition) ______________________ 106 16.27 Alarm texts ___________________________________ 106 16.27.1 Creating the alarm texts via Win512 version 2.7.x _ 107 16.27.2 Downloading alarm texts to the DU:s 1728 / 1735 / 1736 and ext. FBP:s 1826 / 1828 ________________________ 108 16.28 Real time clock (RTC) __________________________ 108 16.28.1 Daylight saving time ________________________ 109 16.29 Loss of main power source _______________________ 109 16.29.1 Fault: Loss of main power source ______________ 109 16.29.2 LCD backlight _____________________________ 109 16.30 Evacuate _____________________________________ 109 16.31 Win512 Tools menu ____________________________ 110 17 Redundancy in distributed system ___________ 112 17.1 Master and Slaves ________________________________ 112 17.1.1 Master unit _________________________________ 112 17.1.2 Slave unit ___________________________________ 113 17.2 Several control units ______________________________ 115 17.2.1 Master unit _________________________________ 115 17.2.2 Several control units (slaves) ___________________ 115 18 Special New Zealand functions ______________ 118 18.1 Alarm devices ___________________________________ 118 18.1.1 Silence alarm devices (inside switch) _____________ 118 18.1.2 New Zealand FB Silence switch (outside switch) ____ 118 18.2 Battery faults ____________________________________ 120 18.2.1 FAULT: Battery _____________________________ 120 18.2.2 FAULT: Low battery capacity __________________ 120 18.3 Routing equipment isolate (disable) __________________ 120 18.4 Acknowledged alarm _____________________________ 120 19 Cyber sensor functions _____________________ 122 19.1 Pulse up – down counter ___________________________ 123 19.1.1 Pulse up – down counter for smoke ______________ 123 19.1.2 Pulse up – down counter for temperature __________ 123 19.1.3 Pulse up – down counter for smoke & temperature __ 123 19.2 Fire judgement __________________________________ 123 19.3 Alarm threshold levels ____________________________ 124 19.4 Learning function / Learning conditions _______________ 124 19.4.1 Learning conditions ___________________________ 124 19.5 Alarm delay time _________________________________ 126 19.6 Analog data output _______________________________ 127 19.7 Sensitivity compensation __________________________ 127 19.8 Self diagnosis of internal devices ____________________ 128 19.9 Address setting check _____________________________ 128 20 Control unit properties (settings) ____________ 129 20.1 Control unit properties ____________________________ 129 5 Panasonic Eco Solutions Nordic AB MEW01472 Rev: - Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x 20.1.1 General data ________________________________ 129 20.1.2 Type of control unit ___________________________ 129 20.1.3 LED indications by inputs ______________________ 130 20.1.4 Miscellaneous _______________________________ 130 20.1.5 Selective alarm presentation ____________________ 131 20.2 Log events ______________________________________ 132 20.3 Log setup _______________________________________ 132 20.4 Control unit information ___________________________ 132 21 System properties (settings) _________________ 133 21.1 System data _____________________________________ 133 21.1.1 Logical name ________________________________ 133 21.1.2 Alarm delay time _____________________________ 133 21.1.3 Main power loss fault delay time ________________ 133 21.1.4 Alarm reset _________________________________ 133 21.1.5 Door closing by time __________________________ 134 21.1.6 Miscellaneous _______________________________ 134 21.1.7 LCD in quiescent state ________________________ 135 21.2 Time channels ___________________________________ 135 21.3 Time activation output ____________________________ 135 21.4 Door open ______________________________________ 136 21.4.1 Indication door open affected by _________________ 136 21.4.2 Disablement of routing equipment _______________ 136 21.5 National holidays ________________________________ 137 21.6 Alarm algorithms ________________________________ 137 21.6.1 Classic smoke detectors' properties _______________ 137 21.6.2 Heat detectors' (3308, 3309, 3316 and 4300) properties138 21.6.3 Smoke detectors' (3304, 4301, 3316 and 4300) properties139 21.6.4 Multi detectors' (3316 and 4300 + decision algorithm) properties __________________________________________ 139 21.7 System information _______________________________ 140 21.8 Alert Annunciation and Alarm Acknowledgement Facility 140 21.8.1 Alert Annunciation ___________________________ 140 21.8.2 Alarm Acknowledgement Facility _______________ 140 21.9 Two zone dependence _____________________________ 140 22 Compatibility_____________________________ 142 23 Cable types ______________________________ 143 23.1 TLON Network cables ____________________________ 143 23.2 COM loop cables_________________________________ 143 23.3 Ext. FBP / Display Units cables _____________________ 143 23.4 Conventional zone line cables _______________________ 143 23.5 Alarm device cables ______________________________ 144 23.6 Other cables _____________________________________ 144 24 COM loop cable length _____________________ 145 25 Current consumption ______________________ 148 6 Panasonic Eco Solutions Nordic AB MEW01472 Rev: - Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x 26 Power supply _____________________________ 152 26.1 Charger functions ________________________________ 153 26.1.1 Charging ___________________________________ 153 26.1.2 Battery charging functions: _____________________ 153 26.1.3 Security functions ____________________________ 153 26.2 Current consumption calculations ____________________ 154 26.3 Rectifier (main power source) _______________________ 155 26.4 Battery (second power source) ______________________ 155 26.5 Fuses __________________________________________ 156 26.6 Form / Table of current consumption _________________ 157 27 S/W versions _____________________________ 158 28 Technical data ____________________________ 159 29 Limitations_______________________________ 160 29.1 User definable texts _______________________________ 160 29.2 C.i.e. / System ___________________________________ 160 30 National regulations _______________________ 162 31 Drawings / connection diagrams _____________ 163 32 Revision history ___________________________ 164 Drawings according to the valid table of drawings. 7 Panasonic Eco Solutions Nordic AB MEW01472 Rev: - Planning Instructions Fire alarm system EBL512 G3, United version 2.7.x 8
Description: