ebook img

NASA Technical Reports Server (NTRS) 19960014640: A Study of Large Droplet Ice Accretions in the NASA-Lewis IRT at Near-Freezing Conditions PDF

32 Pages·4.2 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview NASA Technical Reports Server (NTRS) 19960014640: A Study of Large Droplet Ice Accretions in the NASA-Lewis IRT at Near-Freezing Conditions

NASA/TM—1996-107142/REV1 ARL–MR–294 AIAA–96–0934 U.S. ARMY RESEARCH LABORATORY A Study of Large Droplet Ice Accretions in the NASA Glenn IRT at Near-Freezing Conditions Dean R. Miller and Harold E. Addy, Jr. Glenn Research Center, Cleveland, Ohio Robert F. Ide U.S. Army Research Laboratory, Glenn Research Center, Cleveland, Ohio June 2005 The NASA STI Program Office . . . in Profile Since its founding, NASA has been dedicated to • CONFERENCE PUBLICATION. Collected the advancement of aeronautics and space papers from scientific and technical science. The NASA Scientific and Technical conferences, symposia, seminars, or other Information (STI) Program Office plays a key part meetings sponsored or cosponsored by in helping NASA maintain this important role. NASA. The NASA STI Program Office is operated by • SPECIAL PUBLICATION. Scientific, Langley Research Center, the Lead Center for technical, or historical information from NASA’s scientific and technical information. The NASA programs, projects, and missions, NASA STI Program Office provides access to the often concerned with subjects having NASA STI Database, the largest collection of substantial public interest. aeronautical and space science STI in the world. The Program Office is also NASA’s institutional • TECHNICAL TRANSLATION. English- mechanism for disseminating the results of its language translations of foreign scientific research and development activities. These results and technical material pertinent to NASA’s are published by NASA in the NASA STI Report mission. Series, which includes the following report types: Specialized services that complement the STI • TECHNICAL PUBLICATION. Reports of Program Office’s diverse offerings include completed research or a major significant creating custom thesauri, building customized phase of research that present the results of databases, organizing and publishing research NASA programs and include extensive data results . . . even providing videos. or theoretical analysis. Includes compilations of significant scientific and technical data and For more information about the NASA STI information deemed to be of continuing Program Office, see the following: reference value. NASA’s counterpart of peer- reviewed formal professional papers but • Access the NASA STI Program Home Page has less stringent limitations on manuscript at http://www.sti.nasa.gov length and extent of graphic presentations. • E-mail your question via the Internet to • TECHNICAL MEMORANDUM. Scientific [email protected] and technical findings that are preliminary or of specialized interest, e.g., quick release • Fax your question to the NASA Access reports, working papers, and bibliographies Help Desk at 301–621–0134 that contain minimal annotation. Does not contain extensive analysis. • Telephone the NASA Access Help Desk at 301–621–0390 • CONTRACTOR REPORT. Scientific and technical findings by NASA-sponsored • Write to: contractors and grantees. NASA Access Help Desk NASA Center for AeroSpace Information 7121 Standard Drive Hanover, MD 21076 NASA/TM—1996-107142/REV1 ARL–MR–294 AIAA–96–0934 U.S. ARMY RESEARCH LABORATORY A Study of Large Droplet Ice Accretions in the NASA Glenn IRT at Near-Freezing Conditions Dean R. Miller and Harold E. Addy, Jr. Glenn Research Center, Cleveland, Ohio Robert F. Ide U.S. Army Research Laboratory, Glenn Research Center, Cleveland, Ohio Prepared for the 34th Aerospace Sciences Meeting and Exhibit sponsored by the American Society of Aeronautics and Astronautics Reno, Nevada, January 15–18, 1996 National Aeronautics and Space Administration Glenn Research Center June 2005 Document Change History This printing, numbered as NASA /TM—1996–107142/REV1, June 2005, replaces the previous version, NASA Technical Memorandum 107142, January 1996, in its entirety. It contains the following change: Figure 1 has been modified to make the document compliant with “NASA Internet Publishing Content Guidelines,” NASA Information Technology Requirement NITR–2810–3. Note that at the time of writing, the NASA Lewis Research Center was undergoing a name change to the NASA John H. Glenn Research Center at Lewis Field. Both names may appear in this report. Available from NASA Center for Aerospace Information National Technical Information Service 7121 Standard Drive 5285 Port Royal Road Hanover, MD 21076 Springfield, VA 22100 Available electronically at http://gltrs.grc.nasa.gov A STUDY OF LARGE DROPLET ICE ACCRETIONS IN THE NASA GLENN IRT AT NEAR-FREEZING CONDITIONS Dean Miller and Harold E. Addy, Jr. National Aeronautics and Space Administration Glenn Research Center Cleveland, Ohio Robert F. Ide U.S. Army Research Laboratory National Aeronautics and Space Administration Glenn Research Center Cleveland, Ohio NASA/TM—1996-107142/REV1 1 second test entry, only the results from the Twin Otter At the present time the icing database concerning wing were available at the time of this writing. It is large droplets at near-freezing temperatures is vet)' anticipated that the results from the second test entry limited. This is a result of several :factors. First, these with the NACA-23012 wing will be presented in a conditions occur infrequently when considered on a later report. statistical basis. Secondly, iflarge droplet icing clouds are defined to have droplet distributions with Median FACILITY AND MODEL DESCRIPTION Volumetric Diameter (MVD) ranging from 40 to 400~ then this condition falls outside the FAR-part Icing Research Tunnel 25 icing certification envelope. Typically, the The NASA IRT is a closed-loop refrigerated wind emphasis in icing tunnels and icing flight programs tunnel. The test section is 6 ft high and 9 ft wide. and has been on aircraft certification within the FAR-part contains a turntable assembly which allows for model 25 envelope, where icing cloud MVD's are less than angle-of- attack changes. A 5000 hp fan provides 401Jlll. Therefore, the icing tunnel or flight databases airspeeds up to 400 mph (empty test section). The with this condition are very limited. refrigeration heat exchanger can control the air temperature from +40 OF to -40 Of'. The water spray Given the fact that this combination of large droplet system is capable of simulating icing clouds with with near-freezing temperatures is an important issue MVD of 14 to 40~m, and Liquid Water Content for the icing community to deal with. the Icing (LWC) of 0.3 - 3.0 glm3• Figure I shows a schematic Technology Branch at NASA-Lewis Research Center view of the IRT. has attempted to study the large droplet phenomena. One goal of this effort is to increase the size of the Icing Cloud Spray System existing database on large droplet ice accretions at The spray system that generates the icing cloud in the near-freezing temperatures. To achieve this goal, the IRT is composed. of eight spraybars containing a total NASA-Lewis Icing Research Tunnel has been utilized of 95 spray nozzles. The spraybars are located in the to conduct experimental large droplet icing settling chamber upstream of the contraction section as investigations. shown in Figure 1. The spray nozzles used are air assist type atomizers which are not commercially The first experimental large droplet investigations at available but are specially built for NASA. A cross near-freezing temperatures were conducted in the sectional view of the nozzle is shown in Figure 2. NASA-Lewis Icing Research Tunnel (IRT) in December 1994, and also during May 1995. As a Two types of nozzles are currently utilized in the IRT follow on to these investigations, another more spray system and are designated Standard and Mod-I. comprehensive experimental investigation was The Mod-l nozzles were used for the large droplet conducted in the IRT during the last quarter of 1995. tests described in this report. This is because they we The primary objectives of this latter investigation produce L levels closer to those expected for large were: (I) To document the existing capability of the droplets in natural icing clouds, than do the Standard IRT to produce icing clouds of large droplets at near nozzles. The Mod-l nozrles are normally used to freezing temperatures, and (2) To conduct a produce icing clouds with MVD of 14 to 40~ using parametric study of large droplets at near-freezing air pressures from 10 to 80 psig. temperatures on a commuter-class aircraft wing section, by varying temperature, droplet size, airspeed, Model angle-of-attack, flap-setting, and de-icer boot cycling The test article was a 77.25 inch chord Twin Otter time. wing section with a 30"/0 chord flap. The leading edge of the model was outfitted with a full-span pnewnatic This experimental investigation of large droplet ice de-icer boot extending to 10% chord on the suction accretions was comprised of two tests, each one surface, and to II % chord on the pressure surface. A utilizing a different commuter- dass aircraft wing picture of the test article is shown in Figure 3. section. The first test entry utilized a full-scale 77 .25 inch chord Twin Otter wing section with a 30% chord The model was also instrumented with 16 Type-T flap. The second entry utilized a full-scale wing thermocouples at a spanwise location of 42 inches section with a NACA-23012 aitfoil section, and a above the tunnel floor. The thennocouples were nominal chord length of 68 inches at half-span. Due located at various chordwise positions. both on the to time constraints in reducing the data from the NASA/TM—1996-107142/REV1 2 boot and on the metal skin of the airfoil as shown in Tlrfermjnation of Droplet Size Figure 4. A very thin patch ofboot material (.01 inch) Droplet size distributions were measured in the center of was used to cover the boot thermocouples, providing the tunnel test section using two laser-based instruments. physical protection and also providing a good boot A furward scattering specttomerer probe, model FSSP- surface temperature measurement. 100, was used to measure droplets with diameters between 2 and 47"", and ao opIical amy probe, model 0AP230X, LARGE DROPLET SPRAY CALmRATION was used to measure droplets with diameters from 47 to 450~ Both of these instruments are manufactured by The calibration of the IRT's icing cloud was extended Particle Measuring Systems Inc. in Boulder, Colorado. to include the large droplet sizes chosen for this investigation (99~ and 160~). The LWC was Each probe was alternately placed in the center of the fixed at a single value for each of the above droplet tunnel and the stabilized icing cloud was sampled for 100 sizes. No further calibration was required for the seconds at an airspeed of 195 mph. For these tests only 401Jlll droplets, since these droplets are mthin the evety other sprnybm was opernted to reduce the droplet standard IRT cloud calibration envelope. numbe< densities to acceptable levels fur the FSSP to make valid measurements. Reference I details the Determination of Liquid Water Content comparison of using all spraybors and half-spraybars on To detennine the liquid water content (LW C), nine 1.5 the FSSP results and the rationale for why half-spray inch diameter vertical cylinders spaced at nine inches results are more acc_eptaeble. were mounted in the test section of the tunnel The cylinders were ro1ated at approximately 60 lpm They The standard PMS data correction algorithms were used were exposed to the icing cloud for a predetennined including an "activity" correction for the FSSP and bin length of time. The resulting ice accretion was depth of field and amy width cornx:tions fur the detennined by measuring the __ of the iced OAP. The droplet distributions from each probe were cylinders using a probe much tmversed each cylinder combined and the median volumetric __ (MVD) from 6 inches above the tunnel floor to 10 inches from the was calculated The LWC was also computed from the tunnel ceiling. The _ reconled was the iced __ combined droplet distribution as a check against the measurement at vertical intervals of 1.25 inches for each rotating cylinder L WC. cylinder. As an alternate to the PMS data correction algorithm, the The recorded data was used to plot the L WC uniformity NCAR (Baumgardner) methodology was used to in the test section and to calculate the central vaIue of determine the effi:d it woold have 00 the calculated LWC. The cenIIlIl LWC value was calculated using the MVD and LW C.' A comparison of the calculated values equatioo: ofMVD and LWC resulting tiom the PMS and NCAR methods is shown in Table I and the numbe< density and LWC distributions are shown in Figure 5. For both C' I!.r LWC ~ -:-=::--:-: spray conditions, the NCAR method resulted in a decrease Eb*V*tI2 of23 to 30 percent in theMVD and an increase of330 to 389 _ in the LWC. The LWC values resuIting where: from the PMS correction algorithm were judged to be Ar is the ice thickness on the cylinder at the more reasonable since they agreed much more closely center location with the rotating cylinder values. As can be seen in Figure Et, is the average collection efficiency 5, the droplet distributions genernted with the OAPIPMS V is the airspeed correction algorithm are smoother and exhibits a better t istime mau:h to the FSSP distributions than the OAPINCAR C is a constant which includes the ice density correction algorithm. Therefore the MVD values calculated with the PMS algorithm were used as the The ice density is assumed to be 0.88. Using the units of representative values for these spray conditions. Ar in inches, V in miles per hour and t in seconds, the value ofC is 5.0 x104. The time is divided by 2 since one DROPLET SUPERCOOLING INVESTIGATION half of the cylinder is always exposed to the cloud impingement. When the IRT is used to produce icing clouds with normal cloud droplet sizes of 14 to 40fllll, droplet NASA/TM—1996-107142/REV1 3 supercooling is accelerated by the expansion and subsequent cooling of the pressurized air used in the Figure 6 presents experimental ice shape tracings nozzles to promote droplet breakup. The air and water resulting from 3 different initial spraybar air and water are normally heated to approximately 175°F to temperatures and a 160J.Ull MVD icing cloud. A preclude droplet freeze-out. Low atomizing air comparison of the three ice tracings reveals that the pressures of 2 to 5 psig were used to generate large ice shapes are virtually identical for this range of droplets, thereby significantly reducing expansion spraybar air and water temperatures. This cooling. Since large droplets contain a larger amount experimental result confirms the AEDC code of mass to cool, the loss of expansion cooling raised predictions and lends credibility to the code concerns that the droplets might not reach ambient predictions that the droplets are supercooled (with a temperature before impinging on the model. temperature close to that of the airstream). A computer code developed by the Arnold Figure 7 provides additional experimental evidence Engineering Development Center (AEDC) was used to which appears to support the above conclusion. Figure determine the effect of spraybar water temperature on 7 is a time-history plot of temperature obtained from a the degree of droplet cooling.3 Table 2 shows the leading-edge thermocouple. Temperature predicted final droplet temperature for initial water measurements are plotted for the first 7S seconds of a temperatures of 50, 100, and 200 OF. For all code 160J.l.m MVD icing spray. The icing spray was runs,the tunnel test section airspeed was 195 mph, the initiated at t=O seconds. Initially, the leading-edge was tunnel total temperature was 28 OF, and the initial near the tunnel total temperature of 28 OF. Visual relative humidity at the spray location was 83%. Td - observation of this leading-edge region indicated that TR represents the difference between the droplet the icing cloud first impinged on the model at 9 temperature and the air temperature. seconds. Note that at this time the leading-edge temperature began to dip. Over the next 5 seconds the It can be seen from Table 2, that the initial water temperature continued to decrease to a minimum of temperature had a negligible effect on the final droplet 1.5 OF below the initial value. At t=21 seconds temperature. Vatying the initial water temperature complete :freezing of the leading edge area was from 50 "F to 200 "F resulted in only a 0.1 OF change observed, which is where the temperature profile of in droplet temperature. Also, the maximum Figure 7 began leveling at 32°F. temperature difference (between the droplets and the air) was predicted to occur for the largest droplet size The temperature profile shown in Figure 7 suggests of 1601Jlll, where the droplets were predicted to be 1.8 that the impinging droplets were initially cooling the OF warmer than the air. airfoil surface below the total temperature of the tunnel (approximately 28.5 oF). To cool the leading An experiment was conducted to examine the validity edge by 1.5 "P, the droplet temperature would have to of the code results for icing spray clouds with MVO's have been no greater than 27 "P. It was likely that the of 99~ and 160J.l.m. Experimental icing runs were droplet temperature was actually between the conducted in the IRT at an airspeed of 195 mph and a airstream static temperature of 21.7 OF and 27 "F. total temperature of28 OF. A temperature of28°F was Note that the AEDC code predicted that the 160J.Ull suitable for this investigation because it was near droplets would be 1.9 OF above the airstream static freezing, yet didn't exhibit appreciable water runback temperature (see Table 2); thus by this prediction, the and random ice shedding. The result was a traceable droplet temperature would be approximately 23.6 "P. ice shape. For each droplet size, the atomizing air and water temperatures were varied between nominal Clearly, the AEDC analysis and experimental values of 50 "P, 100 "P, and 200 of. Ice was accreted observations lead to the conclusion that the large on the model, and ice shape tracings were obtained. droplets produced in the IRT are supercooled and These ice shape tracings were then compared to approach the static temperature of the airstream. determine how the initial spray and water temperature affected the resultant ice accretion. It should be PARAMETRIC INVESTIGATION mentioned that nominal spraybar temperature values were not always achieved. An attempt was made to The objective of this portion of the test program was to get as close as possible to the nominal values for those study how parameters such as temperature, droplet cases. size, AOA, airspeed, flap setting, and de·icer boot NASA/TM—1996-107142/REV1 4 cycle times affect large droplet ice accretions. was found that as the droplet MVD was increased, the Additionally, it was desired to compile a database of LWC of the icing cloud became more nonuniform over large droplet ice accretions which could be used to the area. of the test section. After review of the large better characterize this phenomena. Table 3 lists the droplet spray calibration data, it was decided. that the range of parameter values which were evaluated for 160}lJll MVD cloud: 1) provided an acceptable area of their effect on large droplet ice accretions. A test unifonn Lw e at the center of the test section and 2) matrix was developed using the parameter values provided the largest droplet size distn"bution which defined in Table 3 and subsequently used to guide the could be confidently measured with the available testing in the IRT. droplet size measuring instrumentation. The test matrix was developed with the assumption The lower limit airspeed of 125 mph represents a that both droplet size and near·freezing temperatures typical approach condition for the Twin Otter aircraft, are key parameters affecting large droplet ice while the upper airspeed limit of 195 mph was chosen accretions. Therefore, a temperature "sweep" was to provide enough of an airspeed variation that its incorporated into the matrix to investigate large effect on the large droplet ice accretions could be droplet ice accretions at temperatures within +/- 4 cP studied. of the freezing point. Previous large droplet studies conducted in the IRT suggested that runback and ice The four angles of attack and the three flap settings sliding may be important features of ice accretions at were considered to be typical of nominal Twin Otter near-freezing temperatures, as these characteristics flight conditions. Also, because this was a rather large had been observed at temperatures at or above 28 OF. chord model (77.25"), it was decided to limit the Therefore, 28 OF was chosen as the lower temperature angle--of-attack to minimize tunnel blockage effects. bound for the temperature sweep. Four different de-icer boot cycling times were tested. It was not possible to test all of the conditions reflected which ranged from no activation of the boot to cycling in Table 3 within the tunnel time alotted for this test the boot in 6 minute intervals. A 3 minute boot cycle program. Therefore, as the temperature sweep was time was the nonnal cycling interval, while the .7 min conducted, one temperature was selected as an cycling time represented the fast cycling interval for "anchor·point". This temperature remained fixed. the Twin Otter. while the other parameters of interest were varied (hence the name "anchor·poinf'). The selection of the Ice Shape Repeatability "anchor point" was subjective and based on Since the effect of large droplet ice accretion on the consultation with NASA colleagues who had aerodynamic peIformance of an aircraft is due to the conducted previous large droplet investigations in the peculiar way it accumulates, the ice shape that forms is IRT . Ice accretions obtained at the anchor point of key importance in studying these effects. Therefore, temperature were believed to be most representative of a significant part of this study was to record large the large droplet icing condition. The "anchor·points" droplet ice accretions under various conditions such selected for this investigation were T = 30 OF at as: temperature, airspeed, droplet size, model angle-of· t airspeeds of 125 mph and 163 mph, and T = 32 OF at attack, model flap setting, and de·icer boot cycling t an airspeed of 195 mph. time. Underlying this type of study is the question of bow well an ice shape is reproduced under a given set In addition to the temperature sweep, large droplet ice of these parameters. accretions were studied at two other temperatures: 5 cP and 0 OF. The 5 OF condition was chosen based on There are two aspects to the question of repeatability meteorological evidence suggesting that the large in this study. The first concerns the ability to closely droplet condition may extend as low as 5 CP, while the reproduce icing conditions in the IRT. The second o OF condition was chosen to obtain impingement centers arOWld how well an ice shape reproduces itself infonnation with short duration icing sprays.4 in a given set of conditions. This latter aspect may at first appear to be totally dependent upon the first. However, in these tests, the ice protection system did The droplet sizes selected for this investigation ranged not completely remove the accwnulated ice and the from the upper end of the standard IRT icing cloud envelope to near the limit of what is currently shape of the residual ice was always somewhat attajnable with the existing IRT spray bar system. It random. Furthennore, at total temperatures VCJy near NASA/TM—1996-107142/REV1 5 freezing (32 +/-2 oF), the accumulated ice would often accretion began to form, there was a distinct ridge be shed off the model independent of the ice protection noted aft of the active portion of the de-ieer boot on system activation. This "self-shedding" occurred in a both the suction and pressure surfaces. random manner, leaving behind a variable ice shape. As the temperature was decreased still further, less As has been found in previous studies, the ability to and less runback was observed aft of the boot probably reproduce icing conditions in the IRT is very good and because more of the water was freezing earlier during continues to improve as enhancements are contirrua1ly the runback process. Eventually, a temperature was being made to the tunneLS Moreover, results found reached where the ice ridge on the boot (aft of the during the droplet cooling portion of this study also . active portion) appeared to reach a relative maximwn. indicated that the IRT reproduces icing conditions This temperature was 30 OF for V :;: 195 mph, while very well. at 125 mph this temperature was 28 OF. Variation in ice shapes formed under nearly identical The pictures in Figure 10 visually depict what a strong conditions can be seen in Figures 8 and 9. Figure 8 effect the total temperature has on the large droplet ice shows ice shape tracings from the spanwise centerline accretion. The lines on the model indicate 5, 10, and of the airfoil for three separate test runs at the same set 15% chord locations. Figure lOa shows the ice of conditions. The active portion of the ice protection accretion on the suction surface for a total temperature system extends to approximately 7.5% chord on the of 32 "P. Runback extended from just aft of the deicer suction surface. It can be seen that the ridge of boot at 10010 chord to beyond 15% chord. Note the residual ice forms in the general vicinity of the edge of lack of a defined ridge just aft of the active portion of the active portion of the boot. However, the ridge the boot at 7.5% chord. Any ice ridge that formed varies considerably in height and shape as well as in tended to be very "slushy" and subsequently was location from 7% to 9.5% chord. Similar results can blown off the ailfoil at this temperature. be seen in Figure 9, which shows three nearly identical cloud runs at a total temperature of 31"F, rather than Dropping the total temperature to 30 "F resulted in the at 32°F. accretion shown in Figure lOb. There was much less runback aft of the boot, and a thin layer of glaze ice This random variation in ridge location, height and was visible between 7.5% to 10% chord. However, the shape was found throughout this entire series of tests. ice was ''wet'' and lacked adhesive strength. because This characteristic of near-freezing temperature large the upper portion of the ridge was shed. Also, we see droplet ice accretion could well be a cause of the the beginning of ice protuberances or nodules just aft unpredictability ofit's effect on aircraft pelformance. of 10% chord. These nodules grew nonnal to the surface and were consistently found just aft of an ice Total Temperature Effect ridge. The effect of total temperature on large droplet ice accretions was investigated by varying the total When the total temperature was further decreased to temperature from 36 OF down to 5 "F, and then 28 OF, we saw a marked change in the ice accretion. comparing the features of the resultant ice accretions. Now the ridge appeared to have more structural This was done at the following nominal condition: strength and, in this case, had resisted shedding. Also MVD = 160.,un, ADA= 0°, Flap = 0 0, Boot cycle = 3 note the lack of runback and the very well defined min, Spray = 18 minutes, and V = 125 and 195 mph. nodule growth aft of the de-icer boot. It is very Generally speaking, the trends noted at 195 mph were evident from this sequence of pictures in Figure 10, similar to those observed at 125 mph. The only that small changes in total temperature can have a difference was in the temperature at which trends were very significant effect on the resultant large droplet ice observed to begin or end. accretion when the total temperature is near 32 OF. At T = 36 OF, all the impinging water ran back to the It was also noted that a liquid region existed at the t trailing-edge and was blown off the model leading-edge of the ailfoil. The width of this zone was Decreasing the temperature to 34 OF, less runback was observed to directly correlate with total temperature. noted and an ice accretion formed at V :;: 195 mph. The warmer the temperature, the wider this zone was. The temperature had to be decreased to 32 OF before Boot thermocouple temperature data verified this an accretion was observed at 125 mph. When the ice observation. Table 4 compares leading-edge boot NASA/TM—1996-107142/REV1 6

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.