Half Yearly Compliance Report on Environmental Surveillance Monitoring & Compliance Status with respect to condition of Environmental Clearance vide letter No. 21-292/2007-IA.III dated July 19, 2007 (Period: 01.06.2014 to 30.11.2014) Submitted to: Copy Submitted to: Northern Regional Office Chairman, Ministry of Environment & Forests Haryana State Pollution Control Board Government of India C-11, Sector-6, Bays No. 24-25, Sector – 31-A Panchkula-134109 Dakshin Marg, Chandigarh – 160 030 Haryana Submitted by: M/s ARTEMIS MEDICARE SERVICES LIMITED Hospital Site, Sector – 51, Gurgaon – 122 001, Haryana Prepared by: ECO CORPORATE TECH & MEDIA SERVICES PVT. LTD. ® 1st Floor, Shivom Enterprises Building, Khasra No. 5564/195-198, Daulatabad Road Industrial Area, Near MGF Toyota, Sector-103, Gurgaon 122 006 Delhi (NCR) Telephone: +91.124.32 45 465 Email: [email protected] Website: www.ecocorporate.com, www.ecomedia.co.in This report has been prepared by M/s Eco Corporate Tech & Media Services Pvt. Ltd. and its owned laboratory Ultratec Research & Analytik Labs; with all reasonable skill, care and diligence for the industrial project by “M/s Artemis Medicare Services Ltd. situated at Hospital Site, Sector-51, Gurgaon 122001 in Haryana”. Any matter outside the scope of work is disclaimed. This report is a legal document of M/s Artemis Medicare Services Ltd. Use of this report in part or full, in whatever nature by any third party, except Government Authorities concerned, should be strictly with permission of M/s Artemis Medicare Services Ltd. M/s Eco Corporate Tech & Media Services Pvt. Ltd. disclaims any responsibility of whatever nature to third parties, except Government Authorities concerned, to whom this report or any part thereof, is made known. Any third party relies on this report on its own risk. Doc. No. Date of Issue Rev. No. Date of Rev. Copy No. Checked & Approved by E/80/2014/DOC004 20-12-2014 00 -- Sunita Mishra Table of Contents Chapter-1: Introduction and Project Description .............................................................................. 1 1.1 Introduction .................................................................................................................................. 1 1.2 Salient features of the Project ...................................................................................................... 2 1) Area ........................................................................................................................................... 2 2) Occupancy ................................................................................................................................. 2 3) Water Consumption .................................................................................................................. 2 4) Water Balance ........................................................................................................................... 2 5) Sewage Treatment .................................................................................................................... 2 6) Parking ...................................................................................................................................... 2 7) Energy Efficiency Measures ...................................................................................................... 3 8) Fire & Safety .............................................................................................................................. 3 9) Rain water harvesting ............................................................................................................... 3 10) Disposal of Wastes .................................................................................................................. 3 1.3 Present Status of the Project ........................................................................................................ 4 1.4 Purpose of the Report .................................................................................................................. 4 1.5 Environment Management Fund ................................................................................................. 4 1.6 Schedule for next six-monthly compliance report ....................................................................... 5 Chapter-2: Compliance Status Report ............................................................................................... 6 I. Point wise compliance report w.r.t. Part-A: Specific Conditions (Construction Phase) .................. 6 II. Point wise compliance report w.r.t. Part-A: Specific Conditions (Operation Phase) ..................... 6 III. Point wise compliance report w.r.t. Part-B: General Conditions .................................................. 9 Chapter-3: Environmental Surveillance Monitoring ........................................................................ 11 3.1 General ....................................................................................................................................... 11 3.2 Objective ..................................................................................................................................... 11 3.3 Planning for environmental monitoring ..................................................................................... 11 3.4 Methodology .............................................................................................................................. 12 3.4.1 Ambient Air ........................................................................................................................ 12 3.4.2 Noise ................................................................................................................................... 13 3.4.3 Ground Water .................................................................................................................... 14 3.4.4 Soil ...................................................................................................................................... 15 3.4.5 Air Emission ........................................................................................................................ 17 3.4.6 Characterization of treated & untreated effluent ............................................................. 17 3.5 Results and Discussions .................................................................................................................. 18 3.5.1 Ambient Air ........................................................................................................................ 18 3.5.2 Ambient Noise .................................................................................................................... 19 3.5.3 Source Noise ....................................................................................................................... 19 3.5.4 Ground Water .................................................................................................................... 20 3.5.5 Soil ...................................................................................................................................... 23 3.5.6 Air Emission ........................................................................................................................ 24 3.5.7 Characterization of treated & untreated effluent ............................................................. 26 3.6 Conclusion ....................................................................................................................................... 27 Annexure-I: Copies of environmental surveillance monitoring report ............................................ 29 Credentials of Ultratec Research & ANalytik Labs, Gurgaon ............................................................ 43 Annexure-II: CTO & Authorizations ................................................................................................. 47 Annexure-III: Form-V (Environmental Statement for FY 2013-2014 ................................................ 53 Annexure-III: Bio-medical Waste Management .............................................................................. 81 Annexure-IV: Data Sheet ................................................................................................................ 88 i e g a P Chapter 1 Introduction and Project Description 1.1 Introduction Artemis Health Institute is a 206-bed super-specialty flagship hospital established by Artemis Health Sciences (AHS) - a healthcare venture launched by the promoters of the Apollo Tyres Group. Artemis aims at creating an integrated world-class healthcare system by leveraging the best medical practices backed by cutting-edge 1. 206-bed super-specialty technology. The super-specialities chosen by hospital Artemis as its area of focus include 2. Location: Hospital Site, Sector- cardiovascular, oncology, orthopedics, 51, Gurgaon, Haryana. Geographical location of the neurosciences and bariatric & minimal unit could be stated as invasive surgery. The facility at Gurgaon is approximately 28° 37’ latitude designed and constructed in strict accordance and 77° 04’ longitude. The with International guidelines. location is about 225 meters above the mean sea level The hospital project is located in sector-51, 3. Accorded EC by the Union Gurgaon in Haryana state. Geographical Ministry of Environment & Forest, Govt. of India vide location of the unit could be stated as letter No. 21-292/2007-IA.III approximately 28° 37’ latitude and 77° 04’ dated July 19, 2007 longitude. The location is about 225 meters 4. Haryana State Pollution above the mean sea level. Control Board granted NOC vide letter No. The project has been granted approval by the HSPCB/2007/TAC-I/199A/56 Haryana Urban Development Authority vide dated 09.02.2007 5. CTO FY 2013-14: Memo bearing No. SDE (S) 2925 dated HSPCB/2013/3229 dated 31- 25/04/2006. 03-2013 issued by HSPCB 6. Air CTO FY 2014-15: No. This project has been accorded HSPCB/Consent/: Environmental Clearance by the Union 2805714GUNOCTOHWM6948 Ministry of Environment & Forest, Govt. of 86 Dated:31/03/2014 India vide letter No. 21-292/2007-IA.III dated 7. Water CTO FY 2014-15: No. HSPCB/Consent/: July 19, 2007 (copy already submitted along 2805714GUNOCTO694886 with previous reports). Further, Consent to Dated:31/03/2014 Establish (CTE)/NOC for the project was also 8. Total Land Area: 32860.83 m2 obtained from Haryana State Pollution 9. Total Built-up Area: 28801 m2 Control Board (HSPCB) vide their letter 10. Greenbelt Area: 15000 m2 11. Water Requirement:450 KLD bearing No. HSPCB/2007/TAC-I/199A/56 12. Wastewater: 200 KLD dated 09.02.2007. Copy of the said CTE/NOC has already been submitted to Authorities concerned as annexure to previous half yearly compliance reports. Half Yearly EC Compliance Report (01-06-2014 to 30-11-2014) Prepared by Eco Corporate Tech & Media Services Pvt. Ltd., Delhi (Artemis SMR Dec.-2014) Page1 of 89. 1.2 Salient Features of the Project: 1) Area: Total plot area of the project is 32860.83 SQM and total built up area is 28801.57 SQM. 2) Occupancy: Total capacity of the hospital in terms of number of beds as per EIA Clearance accorded by the MoEF is 206. Month Year % Occupancy June 2014 82 July 2014 79 August 2014 85 September 2014 81 October 2014 79 November 2014 75 3) Water Consumption: The total water requirement is 450 KLD at maximum. However, currently the water consumption is nearly 268 KLD, out of which fresh water requirement is about 148 KLD. Fresh water is sourced from the HUDA water supply. Nevertheless, water is withdrawn through bore wells in case of inadequate supply from HUDA. 4) Water Balance: Process Water Trade effluent NIL NIL Domestic Water Treated Sewage 125 KLD 120 KLD Fresh Water 148 KLD Cooling Water Make up 70 KLD 5 KLD Wa ter for g reenbel t 50 KLD 18 KLD 5) Sewage Treatment: Sewage generated is treated in an adequately designed Sewage Treatment Plant (STP) with capacity to treat 325 KLD of sewage that is installed inside the project premises. The entire (100%) treated water from STP is recycled/ reused in cooling and horticulture in the hospital. 6) Parking: The building has separate and adequate parking facility. Parking is provided basements, podium, stilt and on surface. Half Yearly EC Compliance Report (01-06-2014 to 30-11-2014) Prepared by Eco Corporate Tech & Media Services Pvt. Ltd., Delhi (Artemis SMR Dec.-2014) Page2 of 89. 7) Energy Efficiency Measures: a) The building envelope for external walls made of bricks, concrete and steel. The R-value for bricks is approximately 0.87 K.m2.W-1 while that for steel and concrete ranges from 1.07 – 1.25 K.m2.W-1 and 0.78 – 1.25 K.m2.W-1, respectively. For fenestration, aluminium panels with glass panes with R-value ranging between 0.004 – 0.005 K.m2.W-1 and 1.075 – 1.25 K.m2.W-1, respectively, shall be used. b) Sun film with solar energy rejection up to 79% and glare reduction up to 91% have been fixed in all patient rooms (South and East facing) and consultant rooms with single glazed glass. All other area is having double glazed windows. This would reduce the load due to solar radiation and also the heat load of the building envelope. Typical thermal conductivity (U-values) ranges between 1.2- 1.4 W-m2-K as compared to 1.5-1.7 W-m2-K range for normal glass. 8) Fire Safety: The building is well equipped with all fire fighting equipments (i.e. fire water tanks, fire pumps, fire hydrants, sprinkler system, fire alarms, fire extinguishers, hose reels etc.) as required under the local fire norms. 9) Rain Water Harvesting: The rainwater collected from the rooftop and other paved areas within the project area is conveyed into the rainwater harvesting system consisting of de-silting chamber, Oil & grease separator and Recharge pit with injection bore for recharge into the groundwater. 10) Disposal of Wastes: The hospital generates following types of wastes: (a) Municipal Solid waste: Segregated at site and managed by M/s Vulcan Waste Management Company. The final disposal is being done at the Common waste disposal site near Bandhwari, Gurgaon. (b) Bio-medical waste: BMW are being collected, segregated and managed by the help of an approved company namely, M/s Vulcan Waste Management Company. Month wise generation of biomedical waste data is given under table 1.1: Month, Year RED (kg) YELLOW (kg) BLUE (kg) June, 2014 3939 3307 1355 July, 2014 6284 4115 1285 August, 2014 11265 7158 1723 September, 2014 11177 5605 1771 October, 2014 8274 4954 1621 November, 2014 7627 6037 1574 (c) Hazardous Waste: The used oil from DG sets is being stored in separate leak proof HDPE drums, labeled as Hazardous Waste. Such wastes are being disposed off with the help of oil recyclers with due approvals from the Ministry of Environment & Forests. Total quantity of hazardous waste in the form of used oil from DG sets that falls under type 5.11 generated from the hospital during 01.06.2014 to 30.11.2014 is 160 litre. The waste has been 1 the Hazardous Waste (Management, Handling & Transboundary Movement) Rules, 2008 Half Yearly EC Compliance Report (01-06-2014 to 30-11-2014) Prepared by Eco Corporate Tech & Media Services Pvt. Ltd., Delhi (Artemis SMR Dec.-2014) Page3 of 89. stored safely for disposal. There was no disposal of used oil since 1.355 Ton of used oil was sold to M/s Lubri Sales, 32, IDC, Mehrauli Road, Gurgaon on 01-05-2014 vide Manifest document No. 6385. 1.3 Present Status of the Project The project is under operational phase. 1.4 Purpose of the Report According to the section 10 (i) of EIA Notification, 2006, it is mandatory for the project management to submit half-yearly compliance reports in respect of the stipulated prior environmental clearance terms and conditions in hard and soft copies to the regulatory authority concerned, on 1st June and 1st December of each calendar year. This report is being submitted for the period December, 2013 to May, 2014, which is due on 1st June, 2014. Further, submission of this report meets also the condition No. (ii) specified under the heading of Part-B: General Conditions of the Environmental Clearance letter vide No. 21-292/2007-IA.III dated July 19, 2007. Additionally, this compliance report shows post-project impacts of the project on the local environment. The environmental compliance report is carried out to verify the following: (i) That the project does not have any adverse environmental impacts in the project area and its surrounding (ii) Compliance with the conditions stipulated in the Environmental Clearance Letter. (iii) That the Project Management is implementing the environmental mitigation measures and safeguards in true spirit as suggested in the approved Form-1, Form-1A, Environmental Management Plan (EMP) and building plans. (iv) Any non-conformity in the project with respect to the environmental implication of the project. 1.5 Environmental Management Funds: Details of expenses incurred in environment management would be as under- Expenses Head Non-recurring Annual Recurring Cost in (Rs.) Cost in (Rs.) APCM 2.5 0.00 STP & ETP 30.4 9.13 Waste Management including bio-medical waste -- 17.40 Noise control 2.0 0.50 Monitoring -- 0.30 Rainwater Harvesting 5.0 0.50 Greenbelt Development & maintenance 3.0 8.80 Miscellaneous 23.5 5.00 TOTAL 66.4 41.63 Half Yearly EC Compliance Report (01-06-2014 to 30-11-2014) Prepared by Eco Corporate Tech & Media Services Pvt. Ltd., Delhi (Artemis SMR Dec.-2014) Page4 of 89. 1.6 Schedules for Next Six-Monthly Compliance Report: The next six-monthly progress report shall be submitted for the period 01-12-2014 to 31-05- 2015; latest by 1st June 2015 at Northern Regional Office of the Ministry of Environment & Forests, Government of India. Half Yearly EC Compliance Report (01-06-2014 to 30-11-2014) Prepared by Eco Corporate Tech & Media Services Pvt. Ltd., Delhi (Artemis SMR Dec.-2014) Page5 of 89. Chapter 2 Compliance Status Report Point wise report on compliance to conditions as stipulated in Environmental clearance (vide letter No. 21-292/2007-IA.III dated July 19, 2007): PART A – SPECIFIC CONDITIONS I. Construction Phase: Complete Note: All conditions relevant to construction stage were complied during construction. II. Operation Phase: In progress S. Condition Note on Compliance Status No. 1 Diesel power generating sets as Silent DG sets are installed in the project as source of backup power for lifts and back up for lifts and all emergency areas in common area illumination should be of the hospital. The DG sets conform to the “enclosed type” and conform to rules prevailing rules made under Environment made under Environment (Protection) (Protection) Act 1986, prescribed for air and Act 1986, prescribed for air and noise noise emission standards as per CPCB emission standards as per CPCB guidelines. Exhausts are discharged by guidelines. Exhausts should be stack, raised above 4 meters (at about 7.5 discharged by stack, raised to 4 meters meters) from the rooftop. above the rooftop. 2 During night time the noise levels During night time the noise levels measured measured at the boundary of the at the boundary of the building were found to building shall be restricted to the be 38.4 dB (A), which is less than 45 dB (A). permissible levels to comply with the Please refer Test Report vide No. 2343 prevalent regulations dated on 17.12.2014 issued by NABL Accredited Laboratory “M/s Ultratec Research & Analytik Labs, Gurgaon enclosed in Annexure-II. 3 The sewage treatment plant of One sewage treatment plant of 325 KLD adequate capacity should be provided capacities has been installed with provision and it should be certified by an to treat the wastewater. The treated independent expert for adequacy as wastewater is being reused for cooling, well as efficiency and submit a report in flushing, landscaping and gardening. The this regard to the Ministry before the treated sewage does conform to the project is commissioned for operation. standards prescribed by Central Pollution The wastewater should be treated up Control Board. Please refer Test Report vide to tertiary level and after treatment No. 2346 dated on 17.12.2014 issued by reused for cooling, flushing, NABL Accredited Laboratory “M/s Ultratec landscaping and gardening etc. Research & Analytik Labs, Gurgaon However, discharge of treated sewage, enclosed in Annexure-II. if any, shall conform to the norms & standards prescribed by Haryana Pollution Control Board 4 Rain water harvesting and ground Rain water harvesting to recharge the water recharging shall be practiced. ground water is being practiced inside the The ground water levels and its quality project. The ground water quality is being should be monitored regularly in monitored regularly Oil & Grease trap has consultation with the Central Ground been provided to remove oil and grease Half Yearly EC Compliance Report (01-06-2014 to 30-11-2014) Prepared by Eco Corporate Tech & Media Services Pvt. Ltd., Delhi (Artemis SMR Dec.-2014) Page6 of 89. S. Condition Note on Compliance Status No. Water Authority. Oil & Grease trap from the surface run off and suspended shall be provided to remove oil and matter is being removed in a settling tank grease from the surface run off and before its utilization for rainwater harvesting suspended matter shall be removed in a settling tank before its utilization for rainwater harvesting 5 The solid waste generated should be All the solid wastes generated are properly properly collected & segregated. collected & segregated from the source of Biodegradable waste should be generation. All the wastes including STP composted and non bio-degradable sludge are being managed by external solid waste should be disposed of to agency. The final disposal of solid waste is municipal landfill sites after recovering being carried out at common waste recyclable waste. STP sludge shall be management facility near Bandhwari, used as manure for gardening Gurgaon. 6 Bio-medical Waste including (i) Bio-medical wastes are being hazardous waste should be disposed disposed off by the help of M/s Vulcan of as per applicable Rules & norms Waste Management Pvt. Ltd., as per with necessary approvals of the Bio-Medical Wastes (Management & Haryana State Pollution Control Board Handling) Rules, 1998 and subsequent amendments. (ii) The used oil from DG sets is being stored in separate leak proof HDPE drums, labeled as Hazardous Waste. Such wastes shall be disposed off as per Hazardous Waste (Management, Handling & Transboundary Movement) Rules, 2008 and subsequent amendments. 7 The green belt design along the The green belt along the periphery of the periphery of the plot shall achieve hospital has been designed in such a way attenuation factor conforming to the that it helps to achieve the day and night day and night noise standards noise standards prescribed for residential prescribed for residential land use. The land use. Please refer Test Report vide No. open spaces inside the plot should be 2343 dated on 17.12.2014 issued by NABL suitably landscaped and covered with Accredited Laboratory “M/s Ultratec vegetation of indigenous variety Research & Analytik Labs, Gurgaon enclosed in Annexure-II. 8 Incremental pollution loads on the Monitoring of the ambient air quality, noise ambient air quality, noise and water level and soil quality are being conducted on quality should be periodically six-monthly basis. Water quality is being monitored after commissioning of the monitored on monthly basis during the project operation phase. The ambient air quality monitoring was performed on 24 hourly basis for the parameters such as PM , 10 PM , Sulfur Dioxide (as SO ), Oxides of 2.5 2 Nitrogen (as NO ), Carbon Monoxide (as 2 CO) and Ozone as O . All the parameters 3 were observed to be within the permissible limits prescribed in Central Pollution Control Board’s National Ambient Air Quality Standards for Residential Areas. Ambient noise level monitoring was conducted for 24 hours. The day and night Half Yearly EC Compliance Report (01-06-2014 to 30-11-2014) Prepared by Eco Corporate Tech & Media Services Pvt. Ltd., Delhi (Artemis SMR Dec.-2014) Page7 of 89. S. Condition Note on Compliance Status No. time L values were recorded by means of a eq noise level meter. Instant Sound Pressure Level from DG sets was also recorded. Ground Water Quality has been monitored by Ultratec Research & Analytik Labs, Gurgaon and the test results have been compared with the requirements of IS 10500: 2012. Please refer Annexure-II for Test reportsissued by NABL Accredited Laboratory “M/s Ultratec Research & Analytik Labs, Gurgaon. 9 Prior permission of the Central Ground Prior permission for use of ground water was Water Authority should be obtained for obtained from Central Ground Water the utilization of ground water Authority vide their letter No. 40-4/GUR- Artemis/CGWA/2007-1492 dated December 11, 2007 (copy already submitted along with previous reports) 10 The Solar energy shall be used for Tapping of solar energy shall be water heating as well as lighting implemented during the second phase of the common areas and verifiable project. Details shall be submitted in due measures shall be adopted for energy course. conservation and water conservation 11 Report on the energy conservation Report on energy audit shall be prepared measures should be prepared and submitted shortly. incorporating details about building materials & technology, R & U Factors etc and submitted to the Ministry in three months time 12 The values of R & U for the building The building envelope for external walls envelope should meet the made of bricks, concrete and steel. The R- requirements of the hot & humid value for bricks is approximately 0.87 climatic location. Details of the building K.m2.W-1 while that for steel and concrete envelope should be worked out and ranges from 1.07 – 1.25 K.m2.W-1 and 0.78 – furnished in three months time 1.25 K.m2.W-1, respectively. For fenestration, aluminium panels with glass panes with R- value ranging between 0.004 – 0.005 K.m2.W-1 and 1.075 – 1.25 K.m2.W-1, respectively, shall be used. Sun film with solar energy rejection up to 79% and glare reduction up to 91% have been fixed in all patient rooms (South and East facing) and consultant rooms with single glazed glass. All other area is having double glazed windows. This would reduce the load due to solar radiation and also the heat load of the building envelope. Typical thermal conductivity (U-values) ranges between 1.2-1.4 W-m2-K as compared to 1.5-1.7 W-m2-K range for normal glass. Half Yearly EC Compliance Report (01-06-2014 to 30-11-2014) Prepared by Eco Corporate Tech & Media Services Pvt. Ltd., Delhi (Artemis SMR Dec.-2014) Page8 of 89.
Description: