ebook img

Methods of Biochemical Analysis, Volume 17 PDF

430 Pages·1969·12.828 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Methods of Biochemical Analysis, Volume 17

METHODS OF BIOCHEMICAL ANALYSIS Volume 17 Advisory Board W. E. COHN, Oak Ridge Notional Laboratory, Tennessee R. CONSDEN, The Canadian Red Cross Memorial Hospital, Taplow, Maiden- head, Berkshire, England J. GROSS, Department of Experimental Medicine and Cancer Research, Hebrew University Hadassah Medical School, Jerusalem, Israel H. HOLTER, Carlsberg Laboratory, Copenhagen, Denmark J. K. N. JONES, Department of Organic Chemistry, Queen's University, Kingston, Ontario, Canada C. G. KING, Institute of Nutrition Sciences, Columbia University, New York,N ew York H. A. LARDY, Department of Biochemistry, University of Wisconsin, Madison H. C. LICHSTEIN, Department of Microbiology, University of Cincinnati, Cincinnati, Ohjo B. G. MALMSTROM, Department of Biochemistry, University of Gateberg, Sweden A. MEISTER, Department of Biochemistry, Cornell University Medical College, New York,N ew York 0. MICKELSEN, Department of Food and Nutrition, Michigan State University, East Lansing, Michigan J. ROCHE, Biochimie Gkdrale et Cornpar&, Collsge de France, Paris, France A. TISELIUS, Institute of Biochemistry, University of Uppsala, Sweden B. L. VALLEE, Biophysics Research Laboratory, Department of Biological Chemis- try, Harvard Medical School, Boston, Massachuseits D. D. VAN SLYKE, Brookhaten National Laboratory, Upton, Long Island, New York METHODS OF BIOCHEMICAL ANALYSIS Edited by DAVID GLICK Stanford University Medical School Palo Alto, California 17 VOLUME INTERSCIENCE PUBLISHERS adivision of John Wiley & Sons, New York London Sydney Toronto The paper used in thia book has a pH of or higher. It has been used 6.5 because the best information now available indicates that this will contribute to its longevity. Copyright @ 1969, by John Wiley & Inc. Sons, All Rights Reserved. No part of this book be reproduced by any means, may nor transmitted, nor translated a machine language without the written into permission of the publisher. 9 10 123 4 56 7 8 Library of Congrw Catalog Card Number 54-7232 SBN 470 307528 PRINTED IN THE UNITED STATIS OF AblERICA METHODS OF BIOCHEMICAL ANALYSIS VOLUME 17 PREFACE Annual review volumes dealing with many different fields of science have proved their value repeatedly and are now widely used and well established. These reviews have been concerned primarily with the results of the developing fields, rather than with the techniques and methods employed, and they have served to keep the ever- expanding scene within the view of the investigator, the applier, the teacher, and the student. It is particularly important that review services of this nature should now be extended to cover methods and techniques, because it is becoming increasingly difficult to keep abreast of the manifold experimental innovations and improvements which constitute the limiting factor in many cases for the growth of the experimental sciences. Concepts and vision of creative scientists far outrun that which can actually be attained in present practice. Therefore an emphasis on methodology and instrumentation is a fundamental need in order for material achievement to keep in sight of the advance of useful ideas. The current volume is another in this series which is designed to try to meet the need in the field of biochemical analysis. The topics to be included are chemical, physical, microbiological, and if necessary, animal assays, as well as basic techniques and instrumentation for the determination of enzymes, vitamins, hormones, lipids, carbo- hydrates, proteins and their products, minerals, antimetabolites, etc. Certain chapters will deal with well-established methods or tech- niques which have undergone sufficient improvement to merit re- capitulation, reappraisal, and new recommendations. Other chapters will be concerned with essentially new approaches which bear promise of great usefulness. Relatively few subjects can be included in any single volume, but as they accumulate these volumes should comprise a self-modernizing encyclopedia of methods of biochemical analysis. By judicious selection of topics it is planned that most subjects of current importance will receive treatment in these volumes. V vi PREFACE The general plan followed in the organisation of the individual chapters is a discussion of the background and previous work, a critical evaluation of the various approaches, and a presentation of the procedural details of the method or methods recommended by the author. The presentation of the experimental details is to be given in a manner that will furnish the laboratory worker with the complete information required to carry out the analyses. Within this comprehensive scheme the reader may note that the treatments vary widely with respect to taste, style, and point of view. It is the Editor’s policy to encourage individual expression in these presentations because it is stifling to originality and justifiably annoy- ing to many authors to submerge themselves in a standard mold. Scientific writing need not be as dull and uniform it too often is. aa In certain technical details, a consistent pattern is followed for the sake of convenience, in the form used for reference citations and as indexing. The success of the treatment of any topic will depend primarily on the experience, critical ability, and capacity to communicate of the author. Those invited to prepare the respective chapters are scien- tists who either have originated the methods they discuss or have had intimate personal experience with them. It is the wish of the Advisory Board and the Editor to make this series of volumes useful possible and to this end suggestions will as as always be welcome. DAVIDG LICK METHODS OF BIOCHEMICAL ANALYSIS VOLUME 17 CONTENTS Oxygen Electrode Measurements in Biochemical Analysis. By M. A. Lessler, Department of Physiology, The Ohio State University, College of Medicine, Columbus, Ohio, and G. P. Brierley, Department of Physiological Chemistry, The Ohio State University, College of Medicine, Columbus, Ohio .............................................. 1 Separation and Determination of Bile Pigments. By R. Brodersen and J. Jacobsen, Department of Biochemistry A, Univer- sity of Copenhagen, Copenhagen, Denmark ............. 31 Practical Aspects of Liquid-Scintillation Counting. By Yutaka Kobayashi and David V.M audsley, Worcester Foundation for Experimental Biology, Shrewsbury, Massachusetts. ... 55 A Critical Evaluation of the Gas Chromatographic Technique for Identification and Determination of Fatty Acid Esters, with Particular Reference to the Use of Analog and Digital Computer Methods. By W. 0. Caster, Depart- ment of Nutrition, School of Home Economics, and the Institute of Comparative Medicine, University of Georgia, Athens, Georgia. ................................... 135 Fluorimetric Assay of Enzymes. By Marc Roth, Laboratoire central, Hdpital cantonal, Geneva, Switzerland. ................ 189 The Measurement of Phenylalanine and Tyrosine in Blood. By Eli Robins, Department of Psychiatry, Washington Uni- versity School of Medicine, St. Louis, Missouri. ......... 287 The Determination of Urea, Ammonia, and Urease. ByA . Kaplan, University Hospital, University of Washington, Seattle, Washington ....................................... 311 Separation, Identification, and Estimation of Prostaglandins. By Jane E. Shaw and P. W.R amwell, Worcester Foundation for Experimental Biology, Shrewsbury, Massachusetts. ... 325 Author Index.. ....................................... 373 Subject Index ............................................. 397 Cumulative Index, Volumes ........................... 1-17. 411 Methods of Biochemical Analysis, VolumeI 7 Edited by David Glick Copyright 6 1969 John Wiley & Sons, Inc. METHODS BIOCHEMICAL VOLUME OF ANALYSIS 17 Oxygen Electrode Measurements in Biochemical Analysis* M. A. LESSLERD, epwanent of Physiology, The Ohio State University, Gdege o f Medicine, Columbus, Ohio, and G. P. BRIERLEY,t -kI of Physiological Chemistry, The Ohio state UR~SWCSo~lle,g e of Medicine, cotumbu,O hio I. Introduction Types of Electrod ........................ ...,..... 33 IT. 1. The Open M ...................... 3 2. The Recessed Microelectr ........................ 4 3. The Clark Electrode. ......... ........................ 5 Construction and Theory.. . .......................... 7 111. 1. Fabricstion ................................................ 7 2. Electrode Behavior. .. .............................. 8 3. Electrode Reactions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 IV. Calibration and Evaluation.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 1. Residual and Zero Current. . . . . . . . ...... 13 2. O2T ension and Content. . . . . . . . . . . , . . . . . . . . . . 14 3. Difficulties and Their Correction.. . . . , . . . . . . . . . . . . . . . . . . . . . . . . 15 4. Rapidity of Response. I . . . . . . . . . . . . . . . . . . . . . . . . . . . . V. Calculatio ............................................ VI. Application to Specific Reactions. . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . 19 1. Mitochondrial Oxidation. . . . . . . . ......................... 20 A. Respiratory Control and P/O Ratios. . . . . . . . . . . . . . . . . . . . . 22 B. IonTransport Efficiency. ............................... 24 C. Multiple Parameter Measurements.. . . . . . . . . . . . . . . . . . . . . . 24 D. First Derivative of 02 Uptake., . . . . . . . . . , . . . . . . . . . . . . . . . 25 E. Mitochondrial Fragments and Complexes. . . . . . . . . . . . . . . . . 25 2. Other Oxidation Reactions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3. Oxygen Evolution Reactions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 VII. Summary ....................................................... 26 References. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . , . . . . . . . . . . . . .. . 27 * Supported by Public Health Service Granta AM-09326, HE-09364, and a NIH Institutional General Research Support Grant. t Established Investigator of the American Heart Association. 1 2 M. A. LESSLER AND 0. P. BRIERLEY I. INTRODUCTION The oxygen electrode depends on the electrolysis of dissolved O2 at a weakly negative cathode. Diffusion lags can be reduced to a minimum by the immersion of the sensor directly in a medium which is constantly stirred, either by vibration of the electrode or the presence of a small, magnetic, stirring bar in the medium. Where stirring or movement of the electrode is not practical, it has been possible to design miniature electrodes which can “look at” the content in a very localized area 0 2 (1). Under proper conditions, the calibrated electrode can give rapid, 0 2 reliable information on the 02 uptake or evolution from a wide variety of biological systems. In 1897, Danneel (2), working in Nernst’s laboratory, studied the electrolysis of O2 at a Pt cathode. It was later observed that O2 reduc- tion at a Pt cathode gave a current-voltage curve with a plateau current proportional to the 0 2c oncentration, After many years of development, Heyrovsky and Shikata (3) designed the first combined polarizer and recorder for use with the dropping Hg electrode. This 1925 instrument WEB called the “polarograph,” a term that has come into general use for all types of measurements involving electroreducible or electrooxidazable substances in solution. Davis (4) gives an excellent historical review of the development of the “oxygen cathode.” The earliest application of the Pt cathode for the study of biochemical systems may be that of Blinks and Skow (5), who in 1938 reported on the O2 exchange of leaves and cell suspensions. About the same time, Petering and Daniels (6) adapted the dropping Hg electrode for the measurement of O2 consumption by green algae, yeast, and blood cells. The dropping Hg electrode never became popular for biochemical meas- urements, but the Pt electrode underwent a rapid development and it was applied to the study of many biochemical systems (7-10). Most investigators refer to the “polarographic method for oxygen determination” although the instrument originally designed as a polaro- graph is seldom used. More recently the terms oxygen electrode or oxygen cathode have been used interchangeably with the Clark electrode, which is a combined design (see Section 11-3 for details) of the cathode and anode used for the measurement of oxygen tension or content by electroreduc- tion of 02. Manometric methods gained widespread popularity because of the relative simplicity and reliability of the tecvques involved. Until the development of the Clark type of electrode, manometry was the method of choice for the study of oxygen uptake or evolution from tissues, ho- OXYGEN ELECTRODE MEASUREMENTS 3 mogenates, and isolated enzyme systems. There are serious limitations in manometric techniques posed by the difficulty in following rapid changes in the gas phase, the relatively long time necessary for both equilibration and measurement, and the inability to measure differences in oxygen content and utilization in different parts of a biological system. The volumetric data obtained indicate only the average exchange of a sample over the period measured, whereas the electrode provides con- 0 2 tinuous information. Most biochemical systems function in intra- or extracellular fluid without the presence of the gas phase required in manometric methods. Oxygen-electrode systems operate well in solu- tions with variable composition as to substrate, gas content, and pH providing more natural conditions for in uitro measurements of metab- olizing systems. They have also been applied for measurements in viuo (11,12). Although it is beyond the scope of this article to cover all ap- plications of the O2 electrode, a good idea of its utility for special prob- lems can be gained from recent reviews and symposia (4,13-15). 11. TYPES OF ELECTRODES 1. The Open Microelectrode This usually consists of a Pt or Au wire sealed in glass with either a pointed (for insertion into cells or tissues) or a flush tip (Figs. 1A-1C) with a calomel (KCI) or Ag-AgC1 reference electrode. Davis (4) dis- cusses the physical behavior of such electrodes in stationary media, indi- cating that the response time decreases from 400 msec for a 10-p diameter wire to 4 msec for a 1-p wire. Lubbers (16) indicates that the current available with minute electrodes is very small and requires expensive stable instrumentation for its measurement. Bare metal electrodes have an additional difficulty in that they are rapidly and require special tech- niques for maintenance of their sensitivity, which decreases by several per cent per hour. Since the current available from an open electrode is greatly increased in a moving medium, a number of rotating and vibrating electrodes have been designed (4,17,18). The movement replaces the layers of solution near the electrode (which rapidly becomes depleted in 02 content) and keeps the electrode more nearly in equilibrium with the material in solu- tion. The movement also serves to keep the biological sample in more uniform suspension, resulting in a better measurement of the 02 utiliza- tion or evolution into the solution. It is necessary to control the rota- tion or vibration of the electrode within small limits in order to obtain

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.