SITRANS F Ultrasonic Flowmeters SITRANS 1010AERWDP Portable Flowmeter O p e r a t i n g I n s t r u c t ions Edition 12/2014 Answers for industry. IMPORTANT NOTICE Controlotron is now part of: Siemens Industry, Inc. Industry Automation Division CoC Ultrasonic Flow Hauppauge, NY 11788 USA 1010AERWDP UNIFLOW UNIVERSAL PORTABLE FLOWMETER This equipment contains components that are susceptible to electrostatic discharge (ESD). Please observe ESD control measures during the handling and connection process. Field Manual A5E02617285 Rev AB December 2014 For use with Operating System Software Version 3.01.06F or later Copyright©2014 Siemens Industry, Inc. All Rights Reserved Made in the USA Manual Changes NOTE: For the latest updates and revisions to this field manual go to: http://support.automation.siemens.com/ and check the Product Manual listing. 1010FMA-56 MANUAL ADDENDUM Operating System Software Version Update Manual Addendum September 2008 Copyright © 2008 Siemens Industry, Inc. All rights reserved Made in the USA Manual Addendum 1010FMA-56 Operating System Software Version Update INTRODUCTION The following software operating system version update is for Version 3 flowmeters. Please refer to this addendum when using this technical manual with Version 3 operating system software and flowmeters that have been updated to Version 5. Operating System Software Changes 1. The [Meter Type Menu] includes a [Language] menu item that allows the selection of multiple flowmeter menu foreign languages. 2. Version 3 and Version 5 Operating System Differences The following table lists the differences between Version 3 and Version 5 operating system menu items and menu hint lines. Version 3 Version 5 Select Pipe Class Pick Pipe Class Pick/Install Xdcr Install Xdcr Data/Span/Set/Ca Span/Set/Cal Strip Chart Setup Display Setup Dual Channel Flow 2 Channel Flow Dual Beam Flow Dual Path Flow Datalogger Setup Logger Setup Temperature Range Temp Range Pipe Configuration Pipe Config Datalogger Setup Logger Setup Datalogger Mode Logger Mode Datalogger Data Logger Data Log Time Interval Logger Interval Display Datalogger Display Logger Recall Site Setup Recall Site Delete Site Setup Delete Site Install Completed? Install Complete Estimated Vs m/s Estimated Vs M/S Channel /Path Setup Channel Setup Reflexor Zero Fault/Set Zero Fault/Set Memory Delay (sec) Memory Delay s) Flow Volume Units Flow Vol. Units Flow Display Range Flow Disp. Range Flow Display Scale Flow Disp. Scale Total Volume Units Total Vol. Units Batch/Sample Total Batch/Sample Tot Calibrate Flowrate Calib. Flowrate Analog Input Setup Analog Inp Setup Flow Vel F/S Velocity F/S Vs m/s Vs M/S Valc % Valc Vaer % Vaer Vs Max m/s Vs Max M/S (continued ) A-1 Manual Addendum 1010FMA-56 Version 3 Version 5 Vs Min m/s Vs Min M/S Channel/Path Setup Chan/Path Setup Vfmax GAL/MIN Vfmax Date Site Created: Site Created: Empty % Empty Analog Output Trim Analog Out Trim Pick flowtube size and type Select flowtube and start operation Empty Flowtube Set Empty Pipe Set Gas Flowmeter Flow and VoS Unit Changes 1. Flowmeter Types Flowmeter configurations included with this change include all SITRANS F Gas Flowmeters (7ME361*). 2. Flow Units The table below describes the translation from the current gas flow units to the new gas flow units, where only Cubic Feet and Cubic Meter volume units are affected. Also note that M = thousands and MM = millions. Mass units and Velocity units remain unchanged. Note: The flow legend changes depending upon the selection of Standard Volume enabled or disabled. FLOW UNITS For STD VOLUME disabled For STD VOLUME enabled Version 3 Version 5 Version 3 Version 5 CU FT/SEC ACFS CU FT/SEC SCFS CU FT/MIN ACFM CU FT/MIN SCFM CU FT/HR ACFH CU FT/HR SCFH CU FT/DAY ACFD CU FT/DAY SCFD KCU FT/SEC MACFS KCU FT/SEC MSCFS KCU FT/MIN MACFM KCU FT/MIN MSCFM KCU FT/HR MACFH KCU FT/HR MSCFH KCU FT/DAY MACFD KCU FT/DAY MSCFD MCU FT/SEC MMACFS MCU FT/SEC MMSCFS MCU FT/MIN MMACFM MCU FT/MIN MMSCFM MCU FT/HR MMACFH MCU FT/HR MMSCFH MCU FT/DAY MMACFD MCU FT/DAY MMSCFD CU M/SEC M3/sec M/SEC NM3/sec CU M/MIN M3/min CU M/MIN NM3/min CU M/HR M3/hr CU M/HR NM3/hr CU M/DAY M3/day CU M/DAY NM3/day KCU M/SEC E3 M3/sec KCU M/SEC E3 NM3/sec KCU M/MIN E3 M3/min KCU M/MIN E3 NM3/min KCU M/HR E3 M3/hr KCU M/HR E3 NM3/hr KCU M/DAY E3 M3/day KCU M/DAY E3 NM3/day MCU M/SEC E6 M3/sec MCU M/SEC E6 NM3/sec MCU M/MIN E6 M3/min MCU M/MIN E6 NM3/min MCU M/HR E6 M3/hr MCU M/HR E6 NM3/hr MCU M/DAY E6 M3/day MCU M/DAY E6 NM3/day A-2 Manual Addendum 1010FMA-56 3. Total Units Total units are similar to flow units. TOTALIZE UNITS For STD VOLUME disabled Version 3 Version 5 CU FT ACF KCU FT MACF MCU FT MMACF CUM M3 KCU M E3 M3 MCU M E6 M3 TOTALIZE UNITS For STD VOLUME enabled Version 3 Version 5 CU FT SCF KCU FT MSCF MCU FT MMSCF CUM NM3 KCU M E3 NM3 MCU M E6 NM3 4. Sound Velocity Units Sound velocity will continue to be reported in units of meters/sec for metric units but will change to Feet/sec for English unit selection. The flowmeter will display M/S and F/S to represent these two variations. Note: The units for Sound Velocity will be based on the [Preferred Units] menu item found in the [Meter Facilities] menu and can not be changed unless a new site is created. 5. Transducer Model Menu Name The following table lists the operating system menu item differences between Version 3 Hi Precision and Version 5 Hi Precision transducer model names that appear on the [Install Xdcr] menu. Note that T1, T2 and T3 indicate the different temperature ranges of the transducer. Version 3 Transducers Version 5 Transducers Hi Precision Hi Precision 1011HG Hi Prec. 1011HP-T1 1011HP-T2 1011HP-T3 A-3
Description: