ebook img

LT-445 cover - Fire Alarm Systems & Fire Alarm Control Panels PDF

24 Pages·2011·1.72 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview LT-445 cover - Fire Alarm Systems & Fire Alarm Control Panels

Advanced Life Safety Solutions MA-485A Apartment Intercom Amplifier 1 I Common 2 Wires 2 3 3 O S1 Vestibule SI Speaker S2 S2 P.O. Lock P P Buzzer Z Z Volume Door Fuse Replace With 2 Amp Type max. 3AG Only MODEL MA-485A WOODBRIDGE, VAUGHAN ONTARIO, CANADA L4K 5W3 16 VAC TI MADE IN KOREA T2 T2 Door Timer T3 T3 L1 LI DC Door max. L2 L2 L3 L3 AC Door L4 L4 A A Canada U.S.A. (cid:31) Mircom 2002 LT-445 Rev. 4.1 25 Interchange Way 60 Industrial Parkway Printed in Canada Installation and Operation Manual Vaughan, ON L4K 5W3 Cheektowaga, NY 14227 Subject to change without prior notice June 2011 Tel: 905-660-4655 Fax: 905-660-4113 Tel: 1-888-660-4655 Fax: 1-888-660-4113 www.mircom.com Table of Contents Table of Contents 1.0 Introduction 5 1.1 About the MA-485A ........................................................................................................ 5 2.0 Mechanical Installation 6 2.1 Vestibule Enclosure Series ............................................................................................ 6 2.2 Compatible Mircom Suite Stations ................................................................................. 6 2.3 Compatible Mirtone Suite Stations ................................................................................. 6 3.0 Electrical Installation 7 3.1 Amplifier ......................................................................................................................... 7 3.2 Door Strike ..................................................................................................................... 7 3.2.1 Silent DC Door Strike Operation .................................................................................... 7 3.2.2 Buzzing AC Door Strike Operation ................................................................................ 7 3.2.3 Door Strike Other Than Mircom M-10/M-20 ................................................................... 8 3.2.4 Door Strike Electrical Requirements ............................................................................. 8 4.0 Specifications 9 4.1 MA-485A Amplifier ......................................................................................................... 9 4.2 PS-3B Transformer ........................................................................................................ 9 4.3 Wiring Specifications ...................................................................................................... 9 5.0 Multiple Stations in a Suite 10 6.0 Operating Instructions 11 6.1 Single Entrance .............................................................................................................. 11 6.2 Two or More Entrances .................................................................................................. 11 7.0 Troubleshooting 12 7.1 System Dead ................................................................................................................. 12 7.2 Distortion ........................................................................................................................ 12 7.3 Hum ............................................................................................................................... 12 7.4 Amplifier Voltage Chart .................................................................................................. 13 7.4.1 Figure 3: MA-485 Door Strike Field Modification ........................................................... 14 7.4.2 Single Vestibule Connection Diagram AC or DC Door Strike Operation ....................... 15 7.4.3 Dual Vestibule Connection Diagram AC Door Strike Operation .................................... 16 7.4.4 Dual Vestibule Connection Diagram DC Door Strike Operation .................................... 17 8.0 Warranty and Warning Information 18 3 List of Figures and Tables List of Figures and Tables Figure 1 Connection for Silent DC Door Strike ............................................................................. 7 Figure 2 Connection for Door Strike Other Than M-10 ................................................................ 8 Figure 3 MA-485 Door Strike Field Modification ........................................................................... 14 Figure 4 Single Vestibule Connection Diagram AC or DC Door Strike Operation ....................... 15 Figure 5 Dual Vestibule Connection Diagram AC Door Strike Operation .................................... 16 Figure 6 Dual Vestibule Connection Diagram DC Door Strike Operation .................................... 17 4 Introduction 1.0 Introduction 1.1 About the MA-485A The MA-485A is a communications amplifier designed for communication between the IS-489 suite stations and the vestibule (lobby) panel, as well as selective door opening. It incorporates an Automatic Level Control (ALC) circuit that provides clean, clear voice communication in both directions. The MA-485A amplifier provides AC (buzzing) and DC (silent) door strike action. For multiple vestibule applications, RL-401A relay units are required. One RL-401A relay unit is required for every two vestibule used. 1.2 Contact Us For General Inquiries, Customer Service and Technical Support you can contact us Monday to Friday 8:00 A.M. to 5:00 P.M. E.S.T. 1.2.1 General Inquiries Toll Free 1-888-660-4655 (North America Only) Local 905-660-4655 Email [email protected] 1.2.2 Customer Service Toll Free 1-888-MIRCOM5 (North America Only) Local 905-695-3535 Toll Free Fax 1-888-660-4113 (North America Only) Local Fax 905-660-4113 Email [email protected] 1.2.3 Technical Support Toll Free 1-888-MIRCOM5 (North America Only) 888-647-2665 International 905-647-2665 Email [email protected] 1.2.4 Website www.mircom.com 5 Introduction 2.0 Mechanical Installation Amplifiers and relays are normally mounted within the vestibule enclosures. Where such enclosures are located out-doors, the amplifiers and relay unit must be installed in a dry indoor ° ° location where the ambient temperature is kept within 32 to 104 F (0 to 40 C). Do not mount transformer closer than 12 inches to the amplifier or vestibule speaker; observe local electrical codes. For installation of vestibule enclosures refer to instructions supplied with the enclosures. 2.1 Vestibule Enclosure Series • M-3000 Custom Standard Series • M-5000 Custom Tamper Resistant Series • K-Series Compact Modular Series 2.2 Compatible Mircom Suite Stations • IS-401B Standard Suite Station • IS-489 Single Gang Station • IS-489-1 Single Gang Station with Office Call • IS-51-3 Vandal Resistant Dual Gang Station 2.3 Compatible Mirtone Suite Stations • IS-401 Standard Suite Station • IS-401-1 Suite Station with Office Call • IS-421 Dual Cone Speaker Station • IS-51-2 Dual Gang Station • IS-485 Single Gang Station • IS-485-1 Single Gang Suite Station with Office Call 6 Introduction 3.0 Electrical Installation 3.1 Amplifier • The door timing may be adjusted on the MA-485A as required, from 1 to 15 seconds. • For connections to terminals S1 and S2, use twisted pair for wiring distance up to three feet; otherwise use shielded twisted pair and connect the shield at the source end only. • Use twisted pair wire from terminals 1 and 2 to the suite stations. 3.2 Door Strike 3.2.1 Silent DC Door Strike Operation • Connect Mircom M-10/M-20 Door Strike to amplifier terminals L1 and L2 for DC (silent) door strike operation and connect remaining terminals as shown in Figure 1. MA-485A PS-3B T1 18 AWG 18V T2 120 VAC 18 AWG 8V T3 L1 M-10/M-20 Door Strike L2 or RL-401 (l1, L2) L3 NC L4 NC A RL-401 (A) Figure 1 Connection for Silent DC Door Strike 3.2.2 Buzzing AC Door Strike Operation • Connect Mircom M-10/M-20 Door Strike to terminals L3 and L4 for AC (buzzing) door strike operation Door Strike Other Than Mircom M-10/M-20 7 Introduction 3.2.3 Door Strike Other Than Mircom M-10/M-20 Connect door strike other than M-10/M-20 as shown in Figure 2. Choose transfer “A” to suit the door strike, refer to door strike specifications below. PS-3B MA-485A 120 VAC 18 V T1 T2 T3 Transf "A" L1 NC L2 NC L3 L4 A NC Door Strike Figure 2 Connection for Door Strike Other Than M-10 3.2.4 Door Strike Electrical Requirements Amplifier Set Up Door Strike Electrical Requirements AC (buzzing) Door Strike with PS-3B Transformer 8-16 Volts AC, 1 Ampere maximum DC (silent) Door Strike 2-6 Volts DC, minimum 2 ohms resistance Other than PS-3b Transformer 4-30 Volts AC, 1 Ampere maximum 8 Introduction 4.0 Specifications 4.1 MA-485A Amplifier • Power Input, Communication:16 VAC 0.3A or 18-28 VDC 0.2 A • Power Input, Door Strike:8-30 VAC 1.5A or 8-30 VDC,1A • Power Output, Communication:500 mW / 45 Ohms • Power Output, Door Strike:3-30 VAC, 1.5A or 3-30 VDC, 1A • Door Strike Timing:1-15 Seconds, Adjustable 4.2 PS-3B Transformer Power Input 110-120 VAC Power Output 8 Volts, 13 VA 16 Volts, 17 VA 24 Volts, 20 VA 4.3 Wiring Specifications • The following conductor pairs require twisted pair wiring for distances up to three feet, twisted shielded pair wiring for greater distances is recommended: S1 and S2, S3 and S4, S5 and S6. • Use adequate wire sizes in order to keep resistance of each conductor below the following Power Lines: T1, T2, T3, L1, L2, L3, L4, L5, L6, X1, X2, X3, X4 Communication Lines: 1, 2, 3, S1, S2, S3, S4, S5, S6 Function Lines: P, P1, P2, A, Z, Z2, Z Table 1 Wire Chart Distance Power Wires Communication Wires Function (meters) (feet) (AWG) (AWG) (AWG) 50 164 #18 #22 #22 75 246 #16 #22 #22 100 328 #14 #20 #22 150 492 #14 #18 #22 200 656 #12 #18 #22 9 Introduction 5.0 Multiple Stations in a Suite If desired, two suite stations may be installed in any suite by parallel connecting the three common wires as well as the selective call terminals (#4) of both stations. The call tone will be heard at both stations. Reply can be made from either station. More than two stations may be connected in any suite, provided that the call selective wire is connected to no more than two stations, that is, the call terminal (#4) will be left unconnected at additional stations resulting in no audible call tone at such stations. Reply can be made from any station. The amplifier and relay unit are normally mounted within the lobby enclosure. When the enclosures are located outdoors, the amplifier and relay unit must be installed in a dry location where the ambient temperature is maintained between 0 °C and 40 °C (32 °F to 104 °F). For installation of lobby enclosures refer to instructions supplied with enclosures. PS-3B transformers may be mounted within the enclosures or at the main fuse panel. Care must be taken to locate transformers at least 12 inches away from the amplifier and the lobby microphone. Observe local electrical codes regarding the installation of Class-2 transformers. Suite station handsets can be mounted on single gang electrical boxes. 10

Description:
.O. Lock Buzzer Door Fuse max. AC ith ype 3AG Operating the optional Post Office Lock actuates the door Systems with wireless transmitters have been designed
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.