ebook img

Joining Wind Load Tables - 400 Series - Andersen Windows PDF

12 Pages·2013·0.96 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Joining Wind Load Tables - 400 Series - Andersen Windows

TECHNICAL DATA Andersen® windows and patio doors make it easy to create a wide variety of combination designs. Combination Types Determining Design Wind Load Performance Proper combination design in conformance with local wind load Ribbon Combinations requirements is vital to the success of your project. To make sure a Ribbons are horizontal window combinations (vertical joins) where opposite sides (head combination is safe and that it complies with local building codes, and sill) of individual windows are fastened to the building structure. the combination design wind load performance capacity must be Stack Combinations determined. Stacks are vertical window combinations (horizontal joins) where opposite sides (both side Correctly determining this performance capacity involves the jambs) of individual windows are fastened to the building structure. following three steps: Two basic configurations are used in combination designs; 1-way configurations or 2-way STEP 1 configurations. Determine Building Code Requirement 1-Way Make sure that you have the proper local codes and have identified specified compliance values. This calculated value (PSF) will be used to determine if the combination will be ac cept able (STEP 3). STEP 2 Determine Product Performance Ribbon Combination Stack Combination Compare product Performance Grade Rating data to the local building code (PSF) requirement. This will show whether the 2-Way individual units in a com bi na tion design are acceptable. Performance Grade Ratings replaces Design Pressure Ratings for measuring product performance. See Performance Grade, Air Infiltration & Sound Transmission Ratings for further information. Multiple Ribbon/Stack Combination STEP 3 Determine Combination Performance 2-way combinations exist when multiple vertical stacks and horizontal ribbons are joined together. Unlike 1-way combinations, the adjacent sides (head and sill, or both side jambs) This step helps determine whether a given product, size, of individual units are not necessarily fastened directly to the building structure. 2-way configuration and joining material type will meet the local building combinations are joined with both vertical and horizontal joining material and may require code design wind load requirement. To determine what joining reinforced joining materials and brackets depending on the local building code requirement for material type to use (wood, LVL, steel or aluminum), compare the design wind load (measured in pounds per square foot, PSF). local building code design wind load requirement to the Design Wind Load Table value for a particular joining material. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 11 ooff 1122 Andersen® Joining Materials and Installation Accessories For a successful installation, designed to provide the required Materials vary depending on the type of units being joined and wind load requirements. design pressure, it is important that Andersen joining materials Narrow joining materials are used to create unit alignment and positive joining between windows. and installation accessories be specified by a project architect Joining materials are not connected to the rough opening structure. Narrow joins can also be or contractor. Andersen offers several types of joining achieved using accessory items such as v-notch gusset plates. Please contact your Andersen materials. Each creates a joining system that maintains the supplier for specific performance and product. look of Andersen® products. Choose the type appropriate for your combination design. 400 Series4 F0r0e nScehrwieoso Fdr®en4c0h0w oSoedri®es Frenchwood® Hinged PatHioin Dgeodo rPatio DoHoinrged Patio2 0D0o oSreries2 D00ou Sbeleri-eHsu Dnogu2b0le0- HSuenrige4s 0D0o uSbelreie-Hs4 uT0ni0ltg- SWearsiehs D Toiltu-b4Wl0ea0-sH hSu Denrogieusb Tleil-tH-Wunagsh Double-Hung The addition of joining materials may affect the overall rough 4W0o0o dS eJoriiensi4Wn C0goa 0oMs dSea eJmtoerieireninasintl Cga Ms4Wea0mote0oer dinSa teJl oriiensin CgAa lMusmeamtieneruinamtl AJoluinminingu Mma JtoeirniaiAnllgu mMiantuemria JloNMionanitne-Rgri eaMiln a(fLtoNMeVrrLocai)eantedl-Rr iJeaoilin n(fLionVrgLc )edNM Joaontine-Rirnieagil n (fLVoVirnLcy)eld J oJoinininiVngig nM yla Jtoeirniainlg MaVtienryila Jloining Material opening dimension. Review complete installation guides Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Trim StripTrim Strip Trim Strip Exterior Exterior Exterior Trim StripTrim Strip Trim Strip available from your local Andersen supplier or on our Trim StripTrim Strip Trim Strip Trim StripTrim Strip Trim Strip website at andersenwindows.com. Andersen Exterior Trim Strips - A variety of trim strips for finishing the join between joined products are available in colors to match Andersen windows and doors. Andersen Interior Wood Casing - Available in several wood types, pre-finished options, sizes and style options including laminated arch casings, decorative plinths and key blocks. Components used with each joining system will vary depending Reinforced joining materials are used to create product alignment, positive joining and load on products being joined. Check with your Andersen supplier transfer between the Andersen windows and doors and the rough opening. They provide added for more information. strength capable of withstanding a variety of wind load pressures. The structural performance of any combination is only as high as the lowest structural performance rating of any individual window or joining material in the combination. Laminated Veneer Lumber (LVL) Steel Joining Material Aluminum Joining Material Joining Material Exterior Trim Strip Exterior Trim Strip EExtxeteriroior rT rTirmim S Strtirpip Exterior Trim Strip ExEtxetreioriro Trr Timrim S Stritprip Exterior Trim Strip Exterior Trim Strip Aluminum Joining Material Steel Joining Material ALlVuLm Jinouinmin gJo Minaintegr iMalaterial Steel Joining Material LVALl uJmoiinniunmg MJoaitneirniag lMaterial Steel Joining Material LVL Joining Material End Plate End Bracket End Plate End Bracket End Plate End Bracket LVL joining material is available for both windows Available in 8'-0 1⁄4" (2445), 9'-6" (2896) Available in 6'-0 3⁄32" (1831) and 7'-8" (2337) and patio doors. 4 9⁄16" (116) x 3⁄4" (19) LVL and 12'-6" (3810) lengths. Treated for lengths. High-quality aluminum provides increased and 6 9⁄16" (167) x 3⁄4" (19) LVL is available corrosion resistance, the 4" (102) width stiffness and is anodized for corrosion resistance. and includes an aluminum exterior trim retainer. material provides strength and rigidity. Adjacent Aluminum joining stays within the basic jamb of the LVL materials are available in a variety of lengths windows attach to the steel joining with screws Andersen window so interior casing can be used up to 10' (3048). Use with casement, awning, provided in the kit. Use with casement, awning, without extension jambs. Adjacent windows attach to double-hung and select specialty windows and double-hung and specialty windows. the aluminum joining with screws provided in the kit. patio doors. Use with casement, awning and specialty windows. • Dimensions in parentheses are in millimeters. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 22 ooff 1122 TECHNICAL DATA 1-Way Wood Joining 400 Series: Casement, Awning, Flexiframe® & Complementary Specialty Windows (A + B) ÷ 2 = 12'-6" (3810) 70 60 43 31 23 A B (A + B) ÷ 2 = 12'-0" (3658) 70 60 43 31 23 A (A + B) ÷ 2 = 11'-6" (3505) 70 60 43 31 23 B C (A + B) ÷ 2 = 11'-0" (3353) 70 60 43 31 23 (A + B) ÷ 2 = 10'-6" (3200) 70 60 43 31 23 (A + B) ÷ 2 = 10'-0" (3048) 70 60 43 31 23 C (A + B) ÷ 2 = 9'-6" (2896) 70 60 43 31 23 n sio (A + B) ÷ 2 = 9'-0" (2743) 70 60 43 31 23 n me (A + B) ÷ 2 = 8'-6" (2591) 70 60 43 31 23 w Di (A + B) ÷ 2 = 8'-0" (2438) 70 60 43 31 23 ndo (A + B) ÷ 2 = 7'-6" (2286) 70 60 43 31 23 Wood Joining cent Wi ((AA ++ BB)) ÷÷ 22 == 76''--60"" ((12918314)) 7700 6600 4433 3311 2233 Material a dj (A + B) ÷ 2 = 6'-0" (1829) 70 60 43 31 23 A ge (A + B) ÷ 2 = 5'-6" (1676) 70 60 43 31 23 Note: Stacking of windows is allowed to a maximum a Aver (A + B) ÷ 2 = 5'-0" (1524) 70 P60 S43 31F24 hfoeri ginhfto ormf 1a2ti'o-n6 "a b(3o8u1t 0ta)l. lCero nctoamcbt iynoautrio Ann hdeeirgshetns .supplier (A + B) ÷ 2 = 4'-6" (1372) 70 60 43 32 25 20 (A + B) ÷ 2 = 4'-0" (1219) 70 60 44 33 26 21 (A + B) ÷ 2 = 3'-6" (1067) 70 62 46 36 28 23 (A + B) ÷ 2 = 3'-0" (914) 70 67 50 40 32 26 21 (A + B) ÷ 2 = 2'-6" (762) 70 70 57 45 37 31 25 20 (A + B) ÷ 2 = 2'-0" (610) 70 70 69 55 45 38 30 24 (A + B) ÷ 2 = 1'-6" (457) 70 70 70 70 59 49 40 31 26 21 C = (length of join) 3'-6" 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" (1067) (1219) (1372) (1524) (1676) (1829) (1981) (2134) (2286) (2438) 2-Way Wood Joining 400 Series: Casement, Awning, Flexiframe® & Complementary Specialty Windows (A + B) ÷ 2 = 12'-6" (3810) 23 (A + B) ÷ 2 = 12'-0" (3658) 24 A (A + B) ÷ 2 = 11'-6" (3505) 25 B C (A + B) ÷ 2 = 11'-0" (3353) 26 (A + B) ÷ 2 = 10'-6" (3200) 28 20 (A + B) ÷ 2 = 10'-0" (3048) 29 21 C A B (A + B) ÷ 2 = 9'-6" (2896) 30 22 n sio (A + B) ÷ 2 = 9'-0" (2743) 32 24 n me (A + B) ÷ 2 = 8'-6" (2591) 34 25 w Di (A + B) ÷ 2 = 8'-0" (2438) 36 27 20 ndo (A + B) ÷ 2 = 7'-6" (2286) 39 28 22 Wood Joining nt Wi (A + B) ÷ 2 = 7'-0" (2134) 41 30 23 Material ce (A + B) ÷ 2 = 6'-6" (1981) 45 33 25 a dj (A + B) ÷ 2 = 6'-0" (1829) 48 35 27 21 A ge (A + B) ÷ 2 = 5'-6" (1676) 53 39 30 23 a Aver (A + B) ÷ 2 = 5'-0" (1524) 58 P42 S33 26F21 (A + B) ÷ 2 = 4'-6" (1372) 64 47 36 29 23 (A + B) ÷ 2 = 4'-0" (1219) 70 53 41 32 26 22 (A + B) ÷ 2 = 3'-6" (1067) 70 60 46 37 30 25 21 • Numerical values in charts represent structural (A + B) ÷ 2 = 3'-0" (914) 70 70 54 43 35 29 24 21 pressure only. • Dimensions in parentheses are in millimeters. (A + B) ÷ 2 = 2'-6" (762) 70 70 65 52 42 34 29 25 21 • Structural performance of any combination is only (A + B) ÷ 2 = 2'-0" (610) 70 70 70 64 52 43 36 31 25 20 ainsd hiviigdhu aals utnhiet olorw joeisnti nsgtr umcatuterarila pl einrf othrme acnocmeb oinf aatnioyn . (A + B) ÷ 2 = 1'-6" (457) 70 70 70 70 70 57 48 41 33 27 22 • Andersen® products must be installed and anchored properly according to joining and C = (length of join) 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" installation guides to meet rated structural (914) (1067) (1219) (1372) (1524) (1676) (1829) (1981) (2134) (2286) (2438) performance. Refer to product joining and installation guides at andersenwindows.com. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 33 ooff 1122 1-Way or 2-Way Aluminum Joining 400 Series: Casement, Awning, Flexiframe® & Complementary Specialty Windows (A + B) ÷ 2 = 9'-0" (2743) 70 56 41 31 23 (A + B) ÷ 2 = 8'-6" (2591) 70 60 43 32 25 A (A + B) ÷ 2 = 8'-0" (2438) 70 63 46 34 26 21 B C on (A + B) ÷ 2 = 7'-6" (2286) 70 67 49 36 28 22 nsi (A + B) ÷ 2 = 7'-0" (2134) 70 70 52 39 30 23 e Dim (A + B) ÷ 2 = 6'-6" (1981) 70 70 56 42 32 25 20 C A B ow (A + B) ÷ 2 = 6'-0" (1829) 70 70 60 45 35 27 21 Aluminum Joining Material d Win (A + B) ÷ 2 = 5'-6" (1676) 70 70 66 49 38 29 23 E = 10 x 106 psi, l (AXIS x - x) = .59 in4 nt (A + B) ÷ 2 = 5'-0" (1524) 70 P70 S70 54F41 32 26 21 6061-T6 Aluminum e ac (A + B) ÷ 2 = 4'-6" (1372) 70 70 70 59 45 35 28 23 X X dj e A (A + B) ÷ 2 = 4'-0" (1219) 70 70 70 66 50 39 31 25 erag (A + B) ÷ 2 = 3'-6" (1067) 70 70 70 70 57 44 35 28 Av (A + B) ÷ 2 = 3'-0" (914) 70 70 70 70 65 51 40 33 (A + B) ÷ 2 = 2'-6" (762) 70 70 70 70 70 60 48 39 (A + B) ÷ 2 = 2'-0" (610) 70 70 70 70 70 70 59 48 (A + B) ÷ 2 = 1'-6" (457) 70 70 70 70 70 70 70 63 End Plate C = (length of join) 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" (1219) (1372) (1524) (1676) (1829) (1981) (2134) (2286) For a join with a continuous jamb on For a join with a continuous jamb on one side, multiply PSF by 1.2. both sides, multiply PSF by 1.4. 1-Way or 2-Way Steel Joining 400 Series: Casement, Awning, Flexiframe® & Complementary Specialty Windows (A + B) ÷ 2 = 12'-6" (3810) 50 37 28 22 (A + B) ÷ 2 = 12'-0" (3658) 52 38 29 23 A (A + B) ÷ 2 = 11'-6" (3505) 54 40 30 24 B C (A + B) ÷ 2 = 11'-0" (3353) 57 42 32 25 20 (A + B) ÷ 2 = 10'-6" (3200) 59 44 33 26 21 (A + B) ÷ 2 = 10'-0" (3048) 62 46 35 28 22 C A B (A + B) ÷ 2 = 9'-6" (2896) 66 48 37 29 24 n sio (A + B) ÷ 2 = 9'-0" (2743) 69 51 39 31 25 21 4" (102) x 3/16" (5) Steel Joining Material men (A + B) ÷ 2 = 8'-6" (2591) 70 54 41 33 26 22 E = 29 x 106 psi, l (AXIS x - x) = 1.0 in4 w Di (A + B) ÷ 2 = 8'-0" (2438) 70 57 44 35 28 23 A36 hot rolled steel ndo (A + B) ÷ 2 = 7'-6" (2286) 70 61 47 37 30 25 21 X X nt Wi (A + B) ÷ 2 = 7'-0" (2134) 70 66 50 40 32 26 22 ce (A + B) ÷ 2 = 6'-6" (1981) 70 70 54 43 34 28 24 20 a dj (A + B) ÷ 2 = 6'-0" (1829) 70 70 58 46 37 31 26 22 A ge (A + B) ÷ 2 = 5'-6" (1676) 70 70 64 50 41 34 28 24 21 a Aver (A + B) ÷ 2 = 5'-0" (1524) 70P70 70S55 F45 37 31 27 23 20 (A + B) ÷ 2 = 4'-6" (1372) 70 70 70 62 50 41 35 30 26 22 End Bracket (A + B) ÷ 2 = 4'-0" (1219) 70 70 70 69 56 46 39 33 29 25 22 (A + B) ÷ 2 = 3'-6" (1067) 70 70 70 70 64 53 45 38 33 28 25 22 (A + B) ÷ 2 = 3'-0" (914) 70 70 70 70 70 62 52 44 38 33 29 26 23 21 (A + B) ÷ 2 = 2'-6" (762) 70 70 70 70 70 70 62 53 46 40 35 31 28 25 22 20 (A + B) ÷ 2 = 2'-0" (610) 70 70 70 70 70 70 70 66 57 50 44 39 35 31 28 26 23 21 (A + B) ÷ 2 = 1'-6" (457) 70 70 70 70 70 70 70 70 70 66 58 52 46 42 37 34 31 28 25 24 C = (length of join) 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0"10'-6"11'-0"11'-6"12'-0"12'-6" (914) (1067) (1219) (1372) (1524) (1676) (1829) (1981) (2134) (2286) (2438) (2591) (2743) (2896) (3048) (3200) (3353) (3505) (3658) (3810) For a join with a continuous jamb on For a join with a continuous jamb on one side, multiply PSF by 1.2. both sides, multiply PSF by 1.4. • Numerical values in charts represent structural pressure only. • Dimensions in parentheses are in millimeters. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Andersen® products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 44 ooff 1122 TECHNICAL DATA 1-Way LVL Joining 400 Series: Casement, Awning, Flexiframe®, Complementary Specialty Windows (A + B) ÷ 2 = 6'-0" (1829) 82 70 A B on (A + B) ÷ 2 = 5'-6" (1676) 82 71 A si men (A + B) ÷ 2 = 5'-0" (1524) 82 72 B w Di (A + B) ÷ 2 = 4'-6" (1372) 8F2 75 C o nd (A + B) ÷ 2 = 4'-0" (1219) 8S2 79 Wi C nt (A + B) ÷ 2 = 3'-6" (1067) 8P2 82 ace (A + B) ÷ 2 = 3'-0" (914) 82 82 dj e A (A + B) ÷ 2 = 2'-6" (762) 82 82 g era (A + B) ÷ 2 = 2'-0" (610) 82 82 Av (A + B) ÷ 2 = 1'-6" (457) 82 82 5'-6" 6'-0" C = (length of join) (o1r 6le7s6s) (18 29) 4 9/16" (116) x 3/4" (19) LVL Joining Material 2-Way LVL Joining 400 Series: Casement, Awning, Flexiframe®, Complementary Specialty Windows A B m. (A + B) ÷ 2 = 6'-0" (1829) 65 51 41 4 9/16" w Di (A + B) ÷ 2 = 5'-6" (1676) 70 56 45 C (116) ndo (A + B) ÷ 2 = 5'-0" (1524) 70 P62 S50 41F34 C LVL nt Wi (A + B) ÷ 2 = 4'-6" (1372) 70 68 55 46 38 33 ace (A + B) ÷ 2 = 4'-0" (1219) 70 70 62 51 43 37 32 A B dj e A (A + B) ÷ 2 = 3'-6" (1067) 70 70 70 59 49 42 36 Averag ((AA ++ BB)) ÷÷ 22 == 32''--60"" ((796124)) 7700 7700 7700 6790 5689 4599 4521 4LV L9/ 1J6o"i n(i1n1g 6M) axt e3r/i4a"l (19) 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" C = (length of join) (1219) (1372) (1524) (1676) (1829) (1981) (2134) or less (A + B) ÷ 2 = 10'-0" (3048) 82 75 63 56 48 44 37 31 24 6 9/16" (A + B) ÷ 2 = 9'-6" (2896) 82 75 63 56 48 44 37 31 24 (167) (A + B) ÷ 2 = 9'-0" (2743) 82 75 63 56 48 44 37 31 24 C C LVL (A + B) ÷ 2 = 8'-6" (2591) 82 75 63 56 48 44 37 31 25 (A + B) ÷ 2 = 8'-0" (2438) 82 75 63 56 48 44 37 31 25 sion (A + B) ÷ 2 = 7'-6" (2286) 82 75 63 56 48 44 38 32 2A6 B A B n me (A + B) ÷ 2 = 7'-0" (2134) 82 75 63 56 49 45 39 33 26 Di w (A + B) ÷ 2 = 6'-6" (1981) 82 75 63 57 50 46 40 34 28 o Wind (A + B) ÷ 2 = 6'-0" (1829) 82 75 64 58 51 47 41 35 29 nt (A + B) ÷ 2 = 5'-6" (1676) 82 77 66 60 54 50 44 37 30 e djac (A + B) ÷ 2 = 5'-0" (1524) 82 79 68 63 56 52 46 39 32 e A (A + B) ÷ 2 = 4'-6" (1372) 82 P82 S73 67F60 56 50 43 35 g Avera (A + B) ÷ 2 = 4'-0" (1219) 82 82 77 71 64 60 53 46 38 6 9/16" (167) x 3/4" (19) (A + B) ÷ 2 = 3'-6" (1067) 82 82 82 79 71 67 60 52 42 LVL Joining Material (A + B) ÷ 2 = 3'-0" (914) 82 82 82 82 78 74 66 57 47 (A + B) ÷ 2 = 2'-6" (762) 82 82 82 82 82 82 78 68 56 (A + B) ÷ 2 = 2'-0" (610) 82 82 82 82 82 82 82 79 66 Note: 2-way joining must be assembled (A + B) ÷ 2 = 1'-6" (457) 82 82 82 82 82 82 82 82 82 on the jobsite within the rough opening. 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" C = (length of join) (1829) (1981) (2134) (2286) (2438) (2591) (2743) (2896) (3048) or less • Numerical values in charts represent structural pressure only. • Dimensions in parentheses are in millimeters. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Andersen® products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 55 ooff 1122 1-Way Joining 400 Series: Woodwright® Double-Hung, Picture & Transom Full-Frame Windows, Tilt-Wash Double-Hung, Picture & Transom Full-Frame Windows (A + B) ÷ 2 = 12'-6" (3810) 50 42 33 28 23 20 A B (A + B) ÷ 2 = 12'-0" (3658) 50 42 33 28 23 20 A (A + B) ÷ 2 = 11'-6" (3505) 50 42 33 28 23 20 C B (A + B) ÷ 2 = 11'-0" (3353) 50 42 33 28 23 20 (A + B) ÷ 2 = 10'-6" (3200) 50 42 33 28 23 20 C (A + B) ÷ 2 = 10'-0" (3048) 50 42 33 28 23 20 Note: Only 1-way combinations similar (A + B) ÷ 2 = 9'-6" (2896) 50 42 33 28 23 20 to those shown above are allowed. n o nsi (A + B) ÷ 2 = 9'-0" (2743) 50 42 33 28 23 20 e Dim (A + B) ÷ 2 = 8'-6" (2591) 50 42 33 28 23 20 or (A + B) ÷ 2 = 8'-0" (2438) 50 42 33 28 23 20 o D w/ (A + B) ÷ 2 = 7'-6" (2286) 50 42 33 28 23 20 o nd (A + B) ÷ 2 = 7'-0" (2134) 50 42 33 28 23 20 Wi nt (A + B) ÷ 2 = 6'-6" (1981) 50 42 33 28 23 20 e ac (A + B) ÷ 2 = 6'-0" (1829) 50 42 33 28 23 20 dj e A (A + B) ÷ 2 = 5'-6" (1676) 50 42 33 28 23 21 g era (A + B) ÷ 2 = 5'-0" (1524) 50 42 33 28 24 21 Av (A + B) ÷ 2 = 4'-6" (1372) 50 P42 3S3 29 F25 22 20 (A + B) ÷ 2 = 4'-0" (1219) 50 42 34 30 26 23 21 (A + B) ÷ 2 = 3'-6" (1067) 50 44 37 32 28 26 23 21 (A + B) ÷ 2 = 3'-0" (914) 50 47 39 35 30 28 25 23 21 20 (A + B) ÷ 2 = 2'-6" (762) 50 50 44 40 35 32 29 27 25 24 22 21 (A + B) ÷ 2 = 2'-0" (610) 50 50 50 46 41 37 34 32 29 27 25 24 23 22 20 20 (A + B) ÷ 2 = 1'-6" (457) 50 50 50 50 50 49 45 42 39 37 34 32 30 29 27 26 25 24 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" C = (length of join) (1219) (1372) (1524) (1676) (1829) (1981) (2134) (2286) (2438) (2591) (2743) (2896) (3048) (3200) (3353) (3505) (3658) (3810) or less • Numerical values in charts represent structural pressure only. • Dimensions in parentheses are in millimeters. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Andersen® products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 66 ooff 1122 TECHNICAL DATA 1-Way Joining with V-Notch Gusset Plates 400 Series: Woodwright® Double-Hung, Picture & Transom Full-Frame Windows, Tilt-Wash Double-Hung, Picture & Transom Full-Frame Windows (A + B) ÷ 2 = 12'-6" (3810) 50 48 41 33 29 24 22 A B B (A + B) ÷ 2 = 12'-0" (3658) 50 48 41 33 29 24 22 (A + B) ÷ 2 = 11'-6" (3505) 50 48 41 33 29 24 22 C A (A + B) ÷ 2 = 11'-0" (3353) 50 48 41 33 29 24 22 (A + B) ÷ 2 = 10'-6" (3200) 50 48 41 33 29 24 22 C (A + B) ÷ 2 = 10'-0" (3048) 50 48 41 33 29 24 22 Note: Only 1-way combinations similar n (A + B) ÷ 2 = 9'-6" (2896) 50 48 41 33 29 24 22 to those shown above are allowed. o nsi (A + B) ÷ 2 = 9'-0" (2743) 50 48 41 33 29 24 22 e Dim (A + B) ÷ 2 = 8'-6" (2591) 50 48 41 33 29 24 22 oor (A + B) ÷ 2 = 8'-0" (2438) 50 48 41 33 29 24 22 D w/ (A + B) ÷ 2 = 7'-6" (2286) 50 48 41 33 29 24 22 V-Notch o Gusset Plate nd (A + B) ÷ 2 = 7'-0" (2134) 50 48 41 33 29 24 22 Wi nt (A + B) ÷ 2 = 6'-6" (1981) 50 48 41 33 29 25 22 e ac (A + B) ÷ 2 = 6'-0" (1829) 50 48 41 33 29 25 23 20 dj e A (A + B) ÷ 2 = 5'-6" (1676) 50 48 41 33 30 26 24 21 g era (A + B) ÷ 2 = 5'-0" (1524) 50 48 41 34 31 27 24 22 20 Av (A + B) ÷ 2 = 4'-6" (1372) 50 P48 S42 36F32 28 26 23 22 (A + B) ÷ 2 = 4'-0" (1219) 50 49 43 37 34 30 28 25 23 21 (A + B) ÷ 2 = 3'-6" (1067) 50 50 47 40 37 33 31 28 26 24 23 20 (A + B) ÷ 2 = 3'-0" (914) 50 50 50 44 40 36 33 30 29 26 25 22 20 (A + B) ÷ 2 = 2'-6" (762) 50 50 50 50 47 42 39 36 34 31 30 26 24 21 20 (A + B) ÷ 2 = 2'-0" (610) 50 50 50 50 50 49 46 42 40 37 35 31 31 27 25 22 (A + B) ÷ 2 = 1'-6" (457) 50 50 50 50 50 50 50 50 50 49 47 44 41 37 34 30 26 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" C = (length of join) (1372) (1524) (1676) (1829) (1981) (2134) (2286) (2438) (2591) (2743) (2896) (3048) (3200) (3353) (3505) (3658) (3810) or less 1-Way or 2-Way Steel Joining with V-Notch Gusset Plates 400 Series: Woodwright® Double-Hung, Picture & Transom Full-Frame Windows, A B B Tilt-Wash Double-Hung, Picture & Transom Full-Frame Windows B (A + B) ÷ 2 = 7'-6" (2286) 50 40 35 30 27 23 21 C A C A (A + B) ÷ 2 = 7'-0" (2134) 50 40 35 30 27 23 21 C A B C (A + B) ÷ 2 = 6'-6" (1981) 50 40 35 30 27 24 22 20 4" (102) x 3/16" (5) Steel Joining on (A + B) ÷ 2 = 6'-0" (1829) 50 40 36 30 28 24 23 20 Material mensi (A + B) ÷ 2 = 5'-6" (1676) 50 41 36 31 29 26 24 21 20 AE 3=6 2h9o tx r1o0lle6 dp ssit,e le (lAXIS x - x) = 1.0 in4 ow Di (A + B) ÷ 2 = 5'-0" (1524) 50 P42 S37 32F30 27 25 22 21 X X d Win (A + B) ÷ 2 = 4'-6" (1372) 50 43 39 34 32 28 27 24 23 21 ent (A + B) ÷ 2 = 4'-0" (1219) 50 45 41 36 34 30 28 26 25 22 21 c a Adj (A + B) ÷ 2 = 3'-6" (1067) 50 50 45 40 37 34 32 29 28 26 24 20 V-Notch e Gusset Plate erag (A + B) ÷ 2 = 3'-0" (914) 50 50 50 44 41 37 35 32 30 28 26 22 Av (A + B) ÷ 2 = 2'-6" (762) 50 50 50 50 48 44 41 38 36 34 31 26 23 (A + B) ÷ 2 = 2'-0" (610) 50 50 50 50 50 50 48 44 41 38 36 34 30 24 21 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" C = (length of join) (1676) (1829) (1981) (2134) (2286) (2438) (2591) (2743) (2896) (3048) (3200) (3353) (3505) (3658) (3810) or less • Numerical values in charts represent structural pressure only. • Dimensions in parentheses are in millimeters. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Andersen® products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 77 ooff 1122 1-Way Joining with Installation Brackets 400 Series: Woodwright® Double-Hung, Picture & Transom Insert Windows, Tilt-Wash Double-Hung, Picture & Transom Insert Windows (A + B) ÷ 2 = 12'-0" (3658) 50 34 24 18 A B B on (A + B) ÷ 2 = 11'-0" (3353) 50 34 24 18 si en (A + B) ÷ 2 = 10'-0" (3048) 50 34 24 18 C A m Di (A + B) ÷ 2 = 9'-0" (2743) 50 34 24 18 dow (A + B) ÷ 2 = 8'-0" (2438) 50 P34 S25 19F15 C n cent Wi ((AA ++ BB)) ÷÷ 22 == 76''--00"" ((21183249)) 5500 3358 2268 2202 1168 15 Ntoo tteh:o s Oen slhy o1w-wna ayb coovme bairnea atilolonws esdim.ilar a Adj (A + B) ÷ 2 = 5'-0" (1524) 50 42 32 26 21 17 e ag (A + B) ÷ 2 = 4'-0" (1219) 50 50 39 31 25 21 17 er Av (A + B) ÷ 2 = 3'-0" (914) 50 50 50 40 33 28 23 18 15 (A + B) ÷ 2 = 2'-0" (610) 50 50 50 50 49 41 34 27 22 Installation brackets should be 3'-6" 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" used at the ends of each join C = (length of join) (1067) (1219) (1372) (1524) (1676) (1829) (1981) (2134) (2286) to attach units to the opening. or less 1-Way or 2-Way Joining with V-Notch Gusset Plates 200 Series: Tilt-Wash Double-Hung Windows A B Ribbons or stacks of 5 units or less with a maximum width/height of 12'-6" (3810). A B No inverted T-joins or palladian configurations are allowed. C 2-way combinations are limited to 2 windows wide by 2 windows tall with a maximum C 6' (1829) wide by 7'-6" (2286) tall and have vertical joining priority. V-notch gusset plates are required for stacks greater than 8' (2438) high, ribbons greater than 9' (2743) wide and all 2-way combinations. Andersen® 200 Series Maximum design pressure 30 PSF V-Notch Gusset Plate • Numerical values in charts represent structural pressure only. • Dimensions in parentheses are in millimeters. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Andersen® products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 88 ooff 1122 TECHNICAL DATA 1-Way LVL Joining 400 Series: Woodwright® Double-Hung, Picture & Transom Insert Windows, Tilt-Wash Double-Hung, Picture & Transom Insert Windows, Flexiframe® Windows (A + B) ÷ 2 = 6'-0" (1829) 82 70 62 50 40 32 A B 4 9/16" n (A + B) ÷ 2 = 5'-6" (1676) 82 71 63 51 42 33 A o (L1V1L6) Dimensi ((AA ++ BB)) ÷÷ 22 == 54''--60"" ((11357224)) 8822 7725 6648 5536 4436 3358 C B w PSF do (A + B) ÷ 2 = 4'-0" (1219) 82 79 71 59 49 39 C n Wi (A + B) ÷ 2 = 3'-6" (1067) 82 82 78 65 54 44 cent (A + B) ÷ 2 = 3'-0" (914) 82 82 82 72 59 48 a Adj (A + B) ÷ 2 = 2'-6" (762) 82 82 82 82 70 57 age (A + B) ÷ 2 = 2'-0" (610) 82 82 82 82 81 66 Aver (A + B) ÷ 2 = 1'-6" (457) 82 82 82 82 82 82 (A + B) ÷ 2 = 1'-0" (305) 82 82 82 82 82 82 C = (length of join) 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 4 9/16" (116) x 3/4" (19) (1676) (1829) (1981) (2134) (2286) (2438) LVL Joining Material or less 2-Way LVL Joining 400 Series: Woodwright® Double-Hung, Picture & Transom Insert Windows, Tilt-Wash Double-Hung, Picture & Transom Insert Windows, Flexiframe® Windows (A + B) ÷ 2 = 10'-0" (3048) 82 75 63 56 48 44 37 31 24 A B 6 9/16" (A + B) ÷ 2 = 9'-6" (2896) 82 75 63 56 48 44 37 31 24 (167) (A + B) ÷ 2 = 9'-0" (2743) 82 75 63 56 48 44 37 31 24 LVL (A + B) ÷ 2 = 8'-6" (2591) 82 75 63 56 48 44 37 31 25 C (A + B) ÷ 2 = 8'-0" (2438) 82 75 63 56 48 44 37 31 25 n sio (A + B) ÷ 2 = 7'-6" (2286) 82 75 63 56 48 44 38 32 26 n e m (A + B) ÷ 2 = 7'-0" (2134) 82 75 63 56 49 45 39 33 26 Di or (A + B) ÷ 2 = 6'-6" (1981) 82 75 63 57 50 46 40 34 28 o /D (A + B) ÷ 2 = 6'-0" (1829) 82 75 64 58 51 47 41 35 29 w ndo (A + B) ÷ 2 = 5'-6" (1676) 82 77 66 60 54 50 44 37 30 Wi acent ((AA ++ BB)) ÷÷ 22 == 54''--60"" ((11357224)) 8822 P7892 S6783 6637F5660 5526 4560 3493 3325 e Adj (A + B) ÷ 2 = 4'-0" (1219) 82 82 77 71 64 60 53 46 38 6 9/16" (167) x 3/4" (19) erag (A + B) ÷ 2 = 3'-6" (1067) 82 82 82 79 71 67 60 52 42 LVL Joining Material Av (A + B) ÷ 2 = 3'-0" (914) 82 82 82 82 78 74 66 57 47 (A + B) ÷ 2 = 2'-6" (762) 82 82 82 82 82 82 78 68 56 Note: 2-way joining must be assembled on the jobsite within the rough opening. When creating (A + B) ÷ 2 = 2'-0" (610) 82 82 82 82 82 82 82 79 66 2-way combinations for 6 9/16" (167) minimum (A + B) ÷ 2 = 1'-6" (457) 82 82 82 82 82 82 82 82 82 wall thickness, 6 9/16" (167) LVL joining material 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" is required. C = (length of join) (1829) (1981) (2134) (2286) (2438) (2591) (2743) (2896) (3048) or less • Numerical values in charts represent structural pressure only. • Dimensions in parentheses are in millimeters. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Andersen® products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 99 ooff 1122 1-Way Joining 400 Series: Single-Panel & Two-Panel Frenchwood® Gliding Patio Doors 200 Series: Narroline® & Perma-Shield® Gliding Patio Doors Maximum design pressure 20 PSF 8' (2438) Max 1-Way Aluminum Joining 400 Series: Frenchwood® Hinged Inswing & Outswing Patio Doors, Frenchwood® Patio Doors Sidelights & Transoms Maximum design 8' (2438) pressure 25 PSF Max Do not join hinge jamb to hinge jamb. Aluminum Joining Material 2-Way Aluminum Joining 400 Series: Frenchwood® Hinged Inswing & Outswing Patio Doors, Frenchwood® Patio Door Sidelights & Transoms 10' Maximum design pressure 20 PSF (3048) Max. Do not join hinge jamb to hinge jamb. Aluminum Joining Material 1-Way LVL Joining 400 Series: Single-Panel and Two-Panel Frenchwood® Gliding Patio Doors 200 Series: Narroline® & Perma-Shield® Gliding Patio Doors The structural performance of any combination is only as high as the lowest structural performance of any individual window or door or 8' (2438) joining material in the combination. Max. Maximum rating for 4 9/ " (116) LVL is equivalent to +62/-77 PSF. 16 Maximum for four-panel patio doors is equivalent to 40 PSF. 4 9/ " (116) x 3/" (19) 16 4 LVL Joining Material • Dimensions in parentheses are in millimeters. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Andersen® products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. 22001133--22001144 440000//220000 SSeerriieess PPrroodduucctt GGuuiiddee PPaaggee 1100 ooff 1122

Description:
2013-2014 400/200 Series Product Guide Andersen Interior Wood Casing - Available in several wood types double-hung and select specialty windows and.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.