ebook img

IS 996: Single-phase a.c. industrial motors for general purpose PDF

2009·15.1 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview IS 996: Single-phase a.c. industrial motors for general purpose

इंटरनेट मानक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. “जान1 का अ+धकार, जी1 का अ+धकार” “प0रा1 को छोड न’ 5 तरफ” Mazdoor Kisan Shakti Sangathan Jawaharlal Nehru “The Right to Information, The Right to Live” “Step Out From the Old to the New” IS 996 (2009): Single-phase a.c. industrial motors for general purpose [ETD 15: Rotating Machinery] “!ान $ एक न’ भारत का +नम-ण” Satyanarayan Gangaram Pitroda ““IInnvveenntt aa NNeeww IInnddiiaa UUssiinngg KKnnoowwlleeddggee”” “!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता हहहहै””ै” Bhartṛhari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 996 : 2009 ~~cff~~~-q"tfi~~ TRTerur ) ( rfRm Indian Standard SINGLE PHASE a.c. INDUCTION MOTORS FOR . GENERAL PURPOSE (Third Revision) ICS 29.160.30 © BIS 2009 BUREAU OF INDIAN srrANDARDS MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002 February 2009 Price Group 8 Rotating Machinery Sectional Committee, ETD 15 FOREWORD This Indian Standard (Third Revision) was adopted by the Bureau ofIndian Standards, after the draft finalized by .the Rotating Machinery Sectional Committee had been approved by the Electrotechnical Division Council. This standard was first published in 1959. The first revision was broughtout in 1964 and the second revision was brought out in 1979. This revision has been undertaken to align it with the latest developments in the field of rotating machinery and also to include the following changes: a) The universal motors are excluded as these motors have very little common application with single phase ac induction motors covered under this standard; b) Performance requirement of various types ofmotors including for fans, pumps etc, are included except for shaded pole and split phase motors; and c) Guidelines for selection of fan duty motors are included (seeAnnex F). This standard recommended the important dimensions for frame ofmotors with foot or resilient mounting either with sleeve or ball bearings which are necessary to ensure mechanical interchangeability. , , This standard covers the requirements and tests for general purpose motors.The motors used in specific applications may have special requirements and these special requirements are subject to agreement between the user and the manufacturer. The special requirements for single-phaseelectric motors for domestic laundry machine are covered in IS 9582 (Part 1) : 1980 'Single-phase electric motors for definite purposes: Part 1Domestic laundry machine motors'. The special requirements and the guidelines for selection of fan duty motors are given in Annex F. Guidance for testing single-phase a.c. is given in IS 7572 : 1972 'Specification for guide for testing single-phase a.c. and universal motors'. To ensure satisfactory installation and maintenance of induction motors, it is urged that the recommendations contained in IS 900 : 1965 'Code ofpracticefor installation and maintenance ofinduction motors (revised)'should be carefully followed. Ifso desired, the thermistors may be used in the windings ofthe motors. The details and specifications of thermistors would be as agreed between the purchaser and the manufacturer. In the formulation of this standard, assistance has been derived from the following publications: IEC 34-1 (1969) Rotating electrical machines - Part 1: Rating and performance, issued by the International Electrotechnical Commission. IEC 34-2 (1972) Rotating electrical machines - Part 2: Methods ofdetermining losses and efficiency of . rotating electrical machinery from tests (excluding machines for traction vehicles), issued by the International Electrotechnical Commission. IEC 72 (1971) Dimensions and outputratings forrotatingelectricalmachines- Framenumbers 56 to400 and flange numbersF55 toFI080, issued by the InternationalElectrotechnical Commission. JIS 4203-1973 Single phase induction motors (for general purpose), issued by the Japanese Standard Association. BS 170: 1962 Specification for the electrical performance of fractional horsepower electric motors and generators, issued by the British Standards Institution. BS 1608 : 1966 Electrically-driven refrigerant condensing units, issued by the British Standards Institution. Publication MG-I-1967 Motors and generators, issued by National Electrical ManufacturersAssociation, USA. For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated expressing the result of a test or analysis, shall be rounded off in accordance with IS 2 : 1960 'Rules for rounding off numerical values (revised)'. The number ofsignificant places retained in the rounded off value should be the same as that of the specified value in this standard. IS 996: 2009 Indian Standard SINGLE PHASE a.c. INDUCTION MOTORS FOR GENERAL PURPOSE ( Third Revision) 1 SCOPE 3.1.7 Thermally ProtectedMotor-A motor provided with thermal protector. 1.1Thisstandardcovers single phase acinduction motors of the capacitor types for voltages upto and including 3.1.8 Thermal Protector - A protective device for 250V and having windings with Class A, Class E, Class assembly as an integral part of the motor and which B, Class F or Class H insulation (see IS 1271 : 1985 when properly applied, protects the motor against Thermal evaluation and classification of electrical 'dangerous overheating due to overload and failure to insulation) and output upto and including 2200 W). start. 1.2 Motors for use on systems complying to voltages 3.1.9 General Purpose Motor-A motor designed in and frequencies other than preferred (see 4) shall be standard ratings withstandard operating characteristics considered as complying with this standard provided and mechanical construction for use underusual service they comply in all other respects. The voltages and conditions withoutrestrictions to a specific application frequency for which they are designed shall be stated or type of application. on the rating plate. 3.1.10 Breakaway (Starting) Torque - The lowest torque developed by the motor in the stand-still 2 REFERENCES condition when the motor is supplied at the rated The list of standards given in Annex A are necessary voltage and rated frequency. adjunct to this standard. 3.1.11 Pull- Up Torque - The smallest torque 3 TERMINOLOGY developed by the motor between zero speed and the speed which corresponds to the pull-out torque when 3.1 For the purpose of this standard, the following the motor is supplied at the rated voltage and rated \ definitions in addition to those covered in IS 1885 frequency. (Part 35) shall apply. 3.1.12 Pull-Out Torque- The highest torque that the 3.1.1 Overload - Any load in excess of the rated motor can develop while running at rated voltage and output expressed as a percentage of rated output. rated frequency. 3.1.2 Momentary Overload - Any overload the 3.1.13 Wide Voltage Motor - A motor rated for the duration ofwhich isso short as not to affect appreciably voltage range of 190-240 V (or any other band the temperature of the motor. specified on the nameplate). This motor shall meet all 3.1.3 Refrigeration Duty Motor - A special purpose performance specifications at the mean of the voltage ventilated motor suitable for driving open type band. At the extreme voltage conditions the motor shall be capable of delivering the rated output. The motors compressor in condensing unit refrigeration. may not necessarily have their other performance in 3.1.4 Fan-DutyMotors -A special purpose motor for accordance with Tables 1 to 11. In case ofcontinuous driving shaft mounted fan or blower. The motor may be operation underextreme voltage limit, the temperature with single speed winding or multi speed windings rise specified in Table 1 of IS 1280~ shall not exceed which give more than one distinct fanlblower speeds, by 10°C. No further tolerance (as given in 5.1.4) on wherein the cooling of motor winding is provided by voltage isapplicable on motors with this type ofmotor. theair handled by the shaftmounted fanes)or blower(s) 4 P.ATED CONDITIONS OF VOLTAGE, 3.1.5 Reversible Motor - A motor which is capable FREQUENCY, .OUTPUT AND SPEED OF of being started from rest and operated in either MOTORS direction ofrotation. 4.1 Rated Voltage 3.1.6 Reversing Motor - A motor capable of being reversed even while running at normal speed by For the purpose of this standard, the preferred rated changing electrical connections. voltage shall be in accordance with IS 12360 be 230V. 1 IS 996: 2009 4.2 Rated Frequency motors shall .be as in IS 1231 and IS 2223 (NEMA frame dimensions addition in this standard suggested The rated frequency shall be 50 Hz. in view of its popularity). 4.3 Rated Output NOTES 1 Whenever the motor construction requires deviation from The preferred output ratings shall be 2.5, 4, 7, 12, 18, the recommended dimensions, the dimensional requirements 25, 40, 60, 90, 120, 180, 250, 370, 550, 750, 1 100, shall be a matter ofagreement between the manufacturer and 1500 and 2 200 Watt. the user. 2 Dimensional requirements of motors smaller than those 4.4 Rated Speeds corresponding to frame 56 shall be subject to an agreement between the manufacturer and the user. Preferred rated speeds shall be corresponding to two 3Toleranceoncentre height shall notbe applicableforresilient poles, four poles and six poles. basemounted motors. Centre height for agiven framesize may .notbeasinIS1231 andthetolerance ontheagreedcentreheight 5 SITE CONDITIONS between the manufacturerand the user shall be-1.5 mm. 4 Oblong holes may be used making it convenientfor sliding 5.1 The following shall constitute the normal site the motors. However, the width of the oblong holes shall be conditions. equal to the diameterspecified for the frame size.Open ended slots are not permissible. 5.1.1 Altitude and Temperature 7.2 Non-standard Dimensions Motors shall be designed for the following site conditions unless otherwise agreed between the Considering the wide variety ofusage and application manufacturer and the purchaser. of motors covered by this standard, motors may be manufactured in frame sizes and dimensions otherthan 5.1.2 Altitude those in 7.1. Unless otherwise specified, the Altitude not exceeding 1000 m. dimensional tolerances (on the declared dimensions) shall be corresponding to the nearest frame size. 5.1.3 Temperature 8 DUTY AND RATING The cooling air temperature not exceeding 40°C. 5.1.4 Voltage and Frequency Variation 8.1 Continuous Rating Motors covered by this standard shall be capable of For the purpose of this standard, unless otherwise delivering rated output with, specified, the general purpose motors shall be continuously rated. a) terminal voltage differing from its rated value by not more than ± 6 percent, or 8.2 Short Time Rating b) frequency differing from its rated value by Ifthe motors are short time rated, the preferred periods not more than ± 3 percent, or shall be 5, 15, 30 or 60 min. c) any combination of (a) and (b). NOTE- Formoredetails onselectionandapplicationofthese In case of continuous operation at extreme voltage motors (see Annex E). limits, the temperature rise specified inTable 1 of 9 GENERAL CONSTRUCTION IS 12802 shall not exceed by more than 10°C. Motors when operated under the extremeconditions ofvoltage 9.1 Mounting. and frequency variations may not necessarily havetheir The following types of mounting shall be used (see performance in accordance with Tables 1 to 11. also IS 2253). 5.2 Variation from Rated Speed 9.1.1 Foot-Mounted Motor This shall be in accordance with Table 12. A motor with feet, the feet being used for fixing it in position. 6 ENVIRONMENT 9.1.2 Flange-Mounted Motor It shall be assumed that the location and moisture or fumes shall not seriously interfere with the operation A motor with flange, the flange being used infor fixing of the motor. it in position. 7 DIMENSIONS 9.1.3 Foot-cum-Flange Mounted Motor 7.1 The recommended dimensions for rigid base A motor with flange and feet, the feet being used for mounted, resilient base mounted and flange mounted fixing it in position. 2 IS 996: 2009 9.1.4 Resilient-Ring Mounted Motor metallic, the material of such enclosure or main structure shall be non flame supporting or self A motor provided with resilient mounting so that it is extinguishing. supported between two resilient rings affixed to itsend shields, the rings being used for mounting by the user. 9.4.2 Thermal Protector 9.1.5 Resilient-Base Mounted Motor When motors are provided with thermal protectors it shall bear a warning label stating 'THERMAL A resilient-ring mounted motor provided with PROTECTOR FITTED' or 'THERMALLY mounting base, the base being used for fixing it in PROTECTED' and shall be conspicuous. position. 9.4.3 Manual Resetting Protector 9.1.6 Stator-Pad Mounted Motor When such protectors are ofmanual resetting type the A motor provided with three or four pads on stator resetting arrangement shall be readily accecsible and body, equispaced in angular position, duly tapped, the identifiable through clear marking. pads being used for fixing motor in position. 9.4.4 Lubrication 9.1~7 End Shield Pad Mounting Readily accessible lubricatingpoints shall be provided, A motor provided with three or four pads onend shield wherever necessary. equispaced in angular position in same plane, duly I tapped, thepads being used for fixing motor inposition. 9.4.5 Lubricant Temperature 9.1.8 Foot-cum-End Shield-Pad Mounting The lubricant of the motor bearings shall be suitable for bearing temperatures which can result from An end shield pad mounted motor with feet, the feet operating conditions covered by this standard. being used for fixing motor in position. 9.4.6 Centrifugal Switch 9.1.9 Extended Bolt Mounting Toensure satisfactory operation the centrifugal switch A motor where extended threaded studs or motor bolts where fitted shall be so disposed that it shall not be are provided to be used for fixing motor in position. exposed to lubricating grease or oil which may be 9.1.10 Frame-Mounted Motor discharged from over lubricated bearings. A motor withoutdriving end shield, the frame or stator 9.4.6.1 Each motor shall be subjected to the minimum body being used for fixing it in position. of 5 cycles of switch operation at no load for motor fitted with centrifugal switch to ensure its proper NOTE- Dimensionsforfixing the motor inposition ofmotors in 9.1.4,9.1.6, 9.1.7,9.1.8,9.1.9, and 9.1.10, shall be a matter operation. ofagreement between the manufacturer and the user. NOTE-Astype test the numberofcycles ofswitchoperation 9.2 Terminal Box shall beconductedfor 1in 250 numbers ofeach type ofswitch. The position ofterminal box, when provided, shall be 9.4.7 Resilient Mounting Material a matter of agreement between the manufacturer and When resilient mountings are an integral part of the the user. motor the mounting shall be oil resistant and resistant 9.3 Mounting Constructions to heat which is produced by the motor. Various mounting constructions are possible with shaft 9.4.8 Resilient Mounting Test horizontal, vertically upwards or vertically downwards The resilient base mounted motor shall withstand and the mountings covered in 9.1 which should form a without slippage between the frame and base an applied subjectmatter ofagreement between the manufacturer torque of 1.5 times the maximum value ofany torque and the user. that can be developed by the motor at rated voltage. 9.4 Constructional Features 9.4.9 Insulating Material Motors shall be processed in a careful and workman Insulating materials used shall be in accordance with like manner. The manufacturer shall use good measurement and production techniques to ensure the IS 1271 as far as insulation class is concerned. highest degree of productreliability and uniformity NOTE- Materials used shall be inaccordance with the class practicable with the materials used in the product. ofinsulation, stated in the rating plate or superior. 9.4.1 Non-metallic Material Enclosure 9.4.10 Insulation ofLeads Ifthe enclosure or main structure ofthe motor is non- The insulation material of connection/external leads 3 IS 996: 2009 supplied with the motor shall be suitable for the 10.1.1 Open Ventilated Motor maximum temperature ofthe part ofmotor coming in A motor having no protective enclosure. contact with these leads. NOTE- Incaseofnon-protectedmotors additional protection 9.4.11 Capacitors shall be provided by the user, Capacitors where used shall comply to IS 2993. 10.1.2 Ventilated Motor NOTES A motorhaving an enclosure so constructed as to give 1 For capacitor-start or capacitor-start capacitor-run motors, protection while ventilation is not materially impeded. the voltage ofthe electrolytic capacitorduring locked rotor at The protection provided by enclosure shall meet rated voltage shall not exceed 90 percent of the rms surge requirements of IP20 in accordance with IS 4691. voltage ofcapacitor. 2 For two value capacitor/permanent split capacitor motor, 10.1.3 Drip ProofMotor during no load run at rated voltage ofthe motorthe voltage of thepaper dielectriccapacitorshall notexceedthe rated voltage A ventilated motor so constructed as to exclude of the paper dielectric capacitor excepting directly loaded vertically falling water ordirt. The protection provided appliances such as monobloc pumps, mono-compressors and by enclosure shall meet requirements of IP2l in fans which always are run at or near full load. Insuch uses the voltage ofthecapacitorshall not exceed95percentofitsrated accordance with IS 4691. voltage when theapplianceisrun atrated load atrated voltage. 10.1.4 WaterProtected Motor 9.4.12 Construction Material A drip proofmotor so constructed that drops of water All materials and components'used in the manufacture falling at an angle up to 150 from the vertical shall of the motor shall conform to the relevant Indian have no harmful effect, the protection provided by Standard, wherever they exist. In case ofany difficulty enclosure shall meet requirements of IP22 in in complying with this requirement, it shall be subject accordance with IS 4691. to agreement between the manufacturer and the 10.1.5 Totally Enclosed Motor purchaser. A motor soconstructed as to prevent the free exchange 9.4.13 Finishing of air between inside and outside of enclosing case. All surfaces exposed to atmosphere which are not The protection"provided by enclosure shall meet adequately protected by metal deposition shall be requirements of IP44 in accordance with IS 4691. protected against corrosion by painting, enamelling, 10.1.6 Totally Enclosed Fan Cooled Motor oxidizing or phosphatizing. A totally enclosed motor with augmented cooling by 9.5 Earthing means of a fan driven by the motor itself blowing .air 9.5.1 Earthing Terminal over motor body or cooling passages" if any. The protection provided by enclosure shall meet At least one separate earthing terminal of adequate requirements of IP44 in accordance with IS 4691. current carrying capacity conveniently located-and visible shall be provided on the motor. The earthing 10.1.7 Environment ProofMotor terminal shall be of suitable material adequately A motor soconstructed that itcan work without further protected against corrosion and shall have 'J,' or 'E' protection from,the weather conditions specified by on or adjacent to it. theuser.The enclosure shall be designated by the letter, 9.5.2 Lead Earthing 'E' example IPE44 or IPE55. If resilient mounted motor is supplied with externall 10.1~8 Weather ProofMotor loose leads to the motor windings, a separate earthing A motor is weather proof when its design reduces the cord or lead shall be supplied. ingress of rain, snow and airborne particles to an amount consistent with a correct operation. The 9.5.3 Plug Earthing enclosure shall be designated by the letter 'W' (placed If any type of motor is supplied with externallloose between IP and the numerals for example IPW44). lead and plug the motor frame shall be connected to 10.1.9 Hose ProofMotors the earth pin of the plug. A motor having enclosure which provides type of 10 TYPES OF ENCLOSURES protection IP55 in accordance with IS 4691. 10.1 Motors covered by this standard shall have one 10.1.10 Motors for Appliances of the enclosures stated below. The enclosures shall meet the requirements of IS 4691. Motors w.hich are intended ultimately to be 4 IS 996: 2009 incorporated in appliances may have enclosures not 12.1.2 Motors conforming to this standard are not providing aspecific degree ofprotection. Such motors expected to.carry sustained overloads. However (unless also shall be considered conforming to this standard agreed to between the manufacturer and the user) so long as they comply with all the requirements of motors rated in accordance with this standard shall be this standard except that relating to enclosures. capable ofwithstanding on test (undergradual increase of torque) without injury, the overloads in torque for 10.1.11 Besides enclosures defined in 10.1 this 15 s is given in Table 2, after having their rated load. standard also recognizes the enclosures arising out of various degrees of protection stated in IS 4691. All the torque values shall be measured in accordance with IS 7572. 11 METHODS OF COOLING Table 2 Momentary Overload for Motors 11.1 The method of cooling of motors and their (Clauses 3.1.13, 5.1.4 and 12.1.2) designations shall be as given in IS 6362. Cooling methods shall be anyone of the following types: 81 Type ofMotor Excess Torque as No. Percentage ofRated a) According to origin ofcooling: Torque (I) (2) (3) 1) Natural cooling - The motor is cooled without the use ofa fan by the movement i) Capacitor-start Induction-run 50 of air and radiation. ii) Capacitor start-and-run 25 I iii) Capacitor-start Capacitor-run 50 2) Self cooling - The motor is cooled by cooling air driven by a fan mounted on 12.2 Temperature Rise the rotor or one driven by it. Temperature rise ofmotors for all types ofenclosures, 3) Separate cooling - The motor is cooled when tested under the rated conditions and in by a fan not driven by its shaft. accordance with the requirements ofthis standard shall b) According to manner ofcooling: not exceed the limits given in Table 1 of IS 12802. I) Open circuit ventilation - The heat is Motors shall, however, be capable ofoperating without given up directly to the cooling air injurious heating at extreme voltage limits stated flowing through the motor which isbeing in 5.1.4 (that is ± 6 percent of rated voltage) or the replaced continuously. extremes of the voltage range specified on the rating 2) Surface ventilation - The heat is given plate. The temperature rise ofmotors to be incorporated up to the cooling air from the external in appliances shall be tested when the motor is installed in the appliance. surface of a totally enclosed motor. 12 GENERAL CHARACTERISTICS 12.3 Short Time Rating 12.1Torques For motors having shorttime rating, the limits specified in Table 1ofIS 12802 may by agreement be increased 12.1.1 With rated voltage and frequency applied to by 1DoC. Where such an agreement is made to increase terminals, the breakaway (starting), pull-up·and pull the limits, the increased limits shall be indicated on out torques shall comply with the requirements given the rating plate. in Table 1. 12.4 Method ofTesting Table 1 Torques of Single-Phase a.c. Motors The measurement of temperature rise shall be done (Clauses 3.1.13,5.1.4,12.1.1 and,I2.3) according to the methods given in IS 7572. 81 Type ofMotor Minimum Minimum Minimum NOTE - In many appliances the cooling of the motor is No. Pull Out Pull Up Break-away affected by aircirculation throughshaftmountedfans/ blowers Torque Torque Torque and the enclosure and as such temperature rise test cannot be Percent of conductedon the motorby itself. Insuchcasesthe manufacturer F.I.T. and the user shall arrive at a suitable rating ofload and time (I) (2) (3) (4) (5) for motor temperature rise test purposes. This rating shall be i) Capacitor-start 200 150 200 marked on the name plate and temperature rise tests may be Induction-run conducted for this rating in the laboratory and shall be judged ii) Capacitor start and 150 20 30 for compliance to the requirements ofthis standard. run iii) Capacitor-start and 200 150 200 12.5 Performance Values capacitor-run 12.5.1 The values of minimum full load speed, 5

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.