CENTRALA ANALOGICA DE INCENDIU FireClass MANUAL INSTALARE ® ISO14001 ISO14001 ISO9001 ISO9001 9191.BNT2 IT-52588 9105.BNT1 IT-52587 CUPRINS INTRODUCERE 5 Programare Dispozitive 31 Centrala de Incendiu FC500 5 Programare Parametri Detectori 32 Lista Accesorii 5 Programare Module Intrare 33 Descriere 5 Programare Module Iesire 33 Intrari 5 Programare Modul I/O Multiple 33 Iesiri 5 Parametri (FC410MIO) 33 Caracteristici functionare 6 Parametri programare Punct Apel Manual 33 Interfata 8 Programare Zone 34 Acces la Semnale si Comenzi 8 Programare Iesiri 34 Alimentare 8 Iesirie NAC1,NAC2 si NAC3 34 Iesirile OS1....OS8 34 Iesirile O9....O16 34 IDENTIFICARE COMPONENTE 9 Programare Optiuni Genera;le 35 CEAS 35 LED-ul de Stare 9 LOG 36 Descrierea Componentelor 14 Calculare Baterie 36 Etichete LED-uri ;si Taste 17 Calculare Cablare in Bucl;a 37 Descrierea Tastelor de Control 18 LangBuilder 37 Creare/Modificare Limba 37 INSTALAREA 19 Instalarea Placilor Accesorii 19 Instalarea Repetoarelor FC500REP 19 Instalarea Centralei 19 Descrierea Terminalelor 20 Terminalele Placii de Baza 20 Cablarea Sistemului 22 Conectarea Disp. Analogice Adresabile 22 Conectarea Disp. Conventionale 22 Conectarea Repetoarelor 22 Conectarea Disp. de Iesire 23 Iesiri de Sirena 23 Conectarea Alimentarii 24 Sonda de Temperatura 25 Instalarea Cutiei Metalice pentru bateria 38Ah 25 Mentenanta 27 PROGRAMARE PRIN PC 29 Introducere 29 Instalare 29 Selectare Limba 29 Fereastra Software 29 Conexiuni Centrala 29 Fereastra Principala 30 Descrierea Icon-uri 30 File 30 Communication 31 Options 31 Database 31 Help 31 PROGRAMARE DIN CENTRALA 40 Utilizarea Sistemului 40 Utilizarea Sistemului 40 Pagina Principala - Accesarea Sistemului 41 Introducere Parola 42 Pagina de Programare 43 Tasta 1 -Autoscan 44 Atentionare Autoscan 44 Tasta 0 Introducere - Modificare Parola 45 47 PROCEDURA INITIALIZARE RAPIDA Detectori 47 Module 47 Zone 48 Iesirile Centralei 48 Zona Conventionala 48 Optiuni Generale Centrala 48 GHID RAPID 49 Caracteristici Tehnice 49 Descrierea Terminalelor 49 4 Centrala de Incendiu Analogica FC500 INTRODUCERE Centrala de Incendiu FC500 (cid:2)Lista Accesorii In acest manual se va utiliza denumirea Centrala FC500 FC500REP Acest Repetor se conecteaza la centrala pentru evidentierea caracteristicilor generice. pe 4 fire. Acesta reda toate alertele sonore si vizuale In alt caz, se va utiliza terminologia specifica. generate de Centrala si permite utilizatorului (final) controlarea acesteia de la distanta (pana la 1000m cu Centrala FC500 este disponibila in urmatoarele modele: cablu dublu torsadat, ecranat). (cid:1) FC510 - Centrala Analogica de Incendiu Adresabila Centrala FC500 suporta un repetor FC500REP cu o bucla extensibila si sursa in comutatie de 5.5A; (cid:1) FC520 - Centrala Analogica de Incendiu Adresabila ARepetorul FC500REP NU ARE CERTIFICARE cu doua bucle extensibile si sursa in comutatie de IMQ-SECURITYSYSTEM. 5.5A; Software FireClass500 Console Aceasta aplicatie (Windows) ofera o programare facila si rapida a Centralei (cid:1) si ofera functie de log evenimente. Componentele acestor Centrale functioneaza optim cand conditiile ambientale de exterior sunt conforme cu cererile clasei 3k5 al IEC 721-3-3:1978. Descriere Buclele Centralei FC500 ofera urmatoarele facilitati: (cid:2)Intrari (cid:1) maxim 250 de dispozitive analogice Maxim 250 de dispozitive pe bucla. (cid:1) linia conventionala a centralei FC500 suporta pana la 30 de dispozitive. Maxim 30 de dispozitive pe linia conventionala. In orice caz, centrala FC500 nu suporta mai mult de 2000 de dispozitive (500 de disp. pentru fiecare pe- (cid:2)Iesiri reche de bucla) (pana la 2000m(Bucla ) folosind Aceasta sectiune descrie functionarea iesirilor Centralei. cablu 2x2.5). Centrala FC500 se alimenteaza cu o sursa in comutatie BENTEL BAQ140T24(27,6V-5,5A) Iesiri Supervizate Centrala va detecta si semnala conditiile de scurt-circuit si intrerupere alimentare pe a-cest Mai mult, toate modelele FC500 au afisor LCD iluminat tip de iesire. cu posibilitatea afisarii a cate 40 de caractere pe 4 linii care ofera informatii despre starea sistemului si ajuta Iesiri Bypass-abile Utilizatorul va putea dezactiva (cu la programarea acestuia. tasta corespunzatoare) aceasta iesire. Iesiri cu mod silentios Utilizatorul va putea opri aceasta iesire (folosind tasta Silence). Iesirile pot fi puse pe mod silentios pe o perioada nede- finita (in modul Day), sau pe Timpul de Silentiozitate programat. (in modul Night). INTRODUCERE 5 - (cid:2)Caracteristici Functionare Pe parcursul stariiSilence (LED S i l e n c e aprins) se poate utiliza tasta Silencepentru oprirea iesirilor, Atentie Centrala FC500 poate fi programata sa afi- sau tasta Reset pentru revenirea la starea de asteptare. seze ATENTIONARI sau stari de PRE-ALARMA inainte de declansarea starii de ALARMA. (cid:1) Daca Centrala functioneaza in modul Night (Noapte), Aceasta stare va fi semnalata de textul WARNING. aceasta va parasi modul Silentios automat, cand Centrala genereaza atentionare cand un punct de intra- Timpul Silentios de Noapte programat a expirat. re (detector) trece de pragul de atentionare si exista riscul unei alarme. Mod Day/Night Centrala poate opera in mod DAY (ZI) - STAREA DE ATENTIONARE va fi semnalata pe: sau NIGHT (NOAPTE). Urmariti sectiunea "PROGRA- (cid:1) afisorul LCD MARE PRIN PC". (cid:1) punctele de iesire WARNING daca optiunea Daca sistemul se seteaza pe silentios in modul DAY, Pre-alarm este activata. starea SILENCE se va mentine pana cand starea se dezactiveaza (de ex. alarme noi). Daca se seteaza pe Pre-alarma Daca o zona genereaza alarma in modul Day, silentios in modul NIGHT, starea SILENCE se va mentine centrala va initializa Timpul de Pre-alarma . pana la expirarea Timpului Silentios de Noapte. Aceasta stare se semnaleaza prin: La pornire (alimentare), sistemul porneste in modul DAY. (cid:1) un beep lent intermitent In acest mod, alarmele/erorile setate pe silentios vor (cid:1) se aprinde LED-ul Pre-al. porni doar la expirarea Timpului silentios de noapte. (cid:1) mesaj pe LCD (cid:1) Activarea iesirilor corespunzatoare daca optiunea Pre-alarma este activata; Eroare Centrala poate detecta si semnaliza erorile (cid:1) descrise in Tabelul nr. 1: Centrala va genera Alarma Instant daca se detectea- za o conditie de alarma in modul Night sau daca se Conditiile de eroare se vor semnala prin: genereaza o alarma de la un Punct de Apel (cid:1) un beep intermitent la intervale de 1 secunda; (cid:1) LED-ul Fault si LED-ul relativ aprinse; Pe parcursul starii de Pre-alarma, este posibila: (cid:1) un mesaj pe afisorul LCD; (cid:1) activarea unei Alarme de Evacuare prin apasarea (cid:1) activarea iesiriiFault; lunga a tastei Evacuate (Nivel Acces 1 - urmariti (cid:1) activarea altor iesiri programate; “Acces la Semnalizari si Comenzi”), (cid:1) palpairea LED-ului Fault. (cid:1) dezactivarea iesirilor Silentioase si intreruperea Tim- pului de Pre-Alarma prin apasarea tastei Silence IesireaFault si alte iesiri (daca Instalatorul le-a progra- (Nivel Acces 2 ). mat) vor reveni la setari initiale odata cu eliminarea erorii. Pe parcursul stariiSilence (LED S i l e n c e aprins) In anumite situatii, conditiile de eroare dispar spontan. se poate utiliza tasta Silencepentru oprirea iesirilor, In aceste cazuri, se va inregistra eroarea in memorie sau tasta Reset pentru revenirea la starea de asteptare. pana ce se reseteaza Centrala. Conditiile de Eroare inregistrate se semnaleaza prin: (cid:1) Daca Centrala functioneaza in modul Night (Noapte), (cid:1) palpairea lenta a LED-ului Fault. aceasta va parasi modul Silentios automat, cand Timpul Silentios de Noapte programat a expirat. Alarma Centrala va genera alarma la expirarea timpului dePre-Alarma. Alarma va fi semnalata prin: (cid:1) un beeprapid, intermitent; (cid:1) LED-urile Alarm aprinse; (cid:1) un mesaj pe afisorul LCD; (cid:1) activarea iesiriiNACFIRE; (cid:1) activarea iesirilorFIRE; (cid:1) activarea altor iesiri programabile. In stare de alarma, utilizatorii COD PIN (Nivel Acces 2 - urmariti “Acces la Semnalizari si Comenzi ”) vor putea: (cid:1) opri iesirilor cu mod silentios prin apasarea tasteiSilence. 6 Centrala de Incendiu Analogica FC500 Switching 1 Eroare Alimentator 1 OS1short Terminal OS1 in scurt Switching 2 Eroare Alimentator 2 OS2short " Centrala NU se alimenteaza OS3short " Mainsfault de la Reteaua principala OS4short " Incarcatorul de baterii al OS5short " Battery centralei este defectuos OS6short " Lowbattery Bateriile Centralei s-au OS7short " descarcat OS8short " Earth LeakagetoEarth TRANSISTOROS1 Eroare tranzistor OS1 24AOutput Iesirea 24A in scurt TRANSISTOROS2 " 24ROutput Iesirea 24R in scurt TRANSISTOROS3 " Zona conventioanala (terminal LC) Conv.zoneopen TRANSISTOROS4 " deschisa TRANSISTOROS5 " Zona conventioanala (terminal LC) Conv.zoneshort TRANSISTOROS6 " in scurt TRANSISTOROS7 " Flashwriting Eroare scriere Flash TRANSISTOROS8 " Flasherasing Eroare stergere LOG NACFIREshort Terminal Incendiu NAC in scurt Maincontroller Eroare Controller principal NAC1short " Firmwaremaincontr. Eroare checksum NAC2short " Eroare checksum date de Prog.datamaincont programare NAC3short " FirmwareDisplay Eroare afisare Checksum NACFIREopen Terminal Incendiu NAC deschis Eroare controller bucla de NAC1open Terminal NAC1 deschis LoopCommunication comunicatie NAC2open " Loopreturnopen Ramura pozitiva a buclei deschisa NAC3open " Loopsignalopen Ramura negativa a buclei deschisa TransistorNACFIRE Eroare tranzistor NAC FIRE Looplocalshort Scurt local pe controller bucla TransistorNAC1 Eroare tranzistor NAC 1 Looprightshort Scurt bucla Dreapta TransistorNAC2 " Loopleftshort Scurt bucla Stanga TransistorNAC3 " Nonanswer Disp. din bucla nu raspunde (DOAR detectori fum) nivel de Dirtylevel murdarie peste prag Tabel 1 Tabelul de Erori Shortcircuit Scurt Circuit pe modulul de intrare Opencircuit Circuit Deschis pe modulul de intr. Powersupply Eroare alimentare Silentios Aceasta centrala are o tasta Silencecare poa- Wrongvalue Un disp. are valoare gresita pe bucla te fi utilizata pentru resetarea iesirilor silentioase la stare de asteptare. Un releu al modulului de iesire Stuckoutput Starea Silentioasa va fi semnalata prin: nu a cuplat (cid:1) LED-ul S i l e n c e aprins. Mai multe disp. pe bucla au Sameaddress Starea Silence se va mentine pana cand se apasa din aceeasi adresa nou tasta S i l e n c e , sau cand este in modul Night Eroare comunicatie pe Display Displaycommunic. pana la expirarea Timpului Silentios de Noapte controller sau cand se detecteaza o noua stare de alarma. LOGFull Eroare LOG (cid:1) LOGnotvalid Continutul LOG-ului e invalid Iesirile silentioase pot fi activate DOAR cand centrala Terminalul OS1 (Iesire supervizata) este in Nivel Acces 2 sau 3. OS1Open deschis OS2Open " OS3Open " OS4open " OS5open " OS6open " OS7open " OS8open " Tabel 1 Tabelul de Erori (Continuat) INTRODUCERE 7 Dezactivat Centrala poate dezactiva: Nivel Acces 2 (L2) Utilizarea sistemului (Cod PIN dispozitivele pe Bucla (intrare si iesire), introdus): Utilizatorii cu cod PIN pot utiliza sistemul. iesirile de sirena, zonele software; (Nivel Utilizator) dispozitivele pe retea (Repetoare sau centrale Slave). Nivel Acces 3 (L3) Programarea si deschiderea cen- tralei (Cod PIN introdus): usa poate fi deschisa DOAR de Zonele DEZACTIVATE nu genereaza alarme sau aten- persoane autorizate prin desfacerea suruburilor tionari de niciun fel, si iesirile DEZACTIVATE nu pot fi in scopul mentenantei, inlocuire baterii etc. (Nivel controlate. Instalator). Starea Dezactivata este semnalata prin: (cid:1) LED-ul Disabledaprins; Nivel acces 4 (L4) Repararea sau inlocuirea placii de baza: recomandat sa se schimbe DOAR de catre (cid:1) Zonele si iesirile pot fi dezactivate doar din Nivel 2 Producator. sau Nivel 3. (cid:2)Alimentare Reset La resetare, Centrala readuce iesirile la starea Alimentatorul centralelor FC500 este conform cu stan- de asteptare, sterge memoria si intrerupe alimentarea dardele EN54-4. terminalelor 24R. Toate modelele se alimenteaza de la retea (230V,50Hz): (cid:1) Modelul FC510 are o sursa in comutatie de pana la (cid:1) Resetarea se poate efectua doar din Nivel 2 sau 5.5 A la 27.6V; Nivel3. (cid:1) Modelul FC520 are o sursa in comutatie de pana la 5.5 A la 27.6V; (cid:2)Interfata Toate modelele accepta doua acumulatoare de 12 V conectate in serie si alimenteaza sistemul cu 24 V in Semnalare vizuala Starea sistemului este semnalata cazul unei pene de curent, si pot furniza un curent sup- de LED-urile centralei astfel: limentar in cazul cand este necesar si nu poate fi debi-- VERDE inseamna conditii normale de functionare tat de sursa in comutatie. PORTOCALIU inseamna moduri specifice de functi- onare (de ex. Mod Day sau Night) si/sau erori sistem. Modelele FC510andFC520accepta doua acumulatoare ROSUinseamna conditie de Alarma. 12 V 17Ah. Memorie Centrala va semnala evenimentele de tip Eroare (LED-ul FAULT palpaie) pana la resetarea sis- (cid:1) Daca e necesar, (Bucla complet configurata sau temului chiar daca evenimentul s-a remediat. cereri particulare ale sistemului), FC510 sau FC520 poate fi conectata la doua acumulatoare de 12 V 38Ah intr-o cutie de metal externa. (Vezi Figura 14) Semnalare Acustica Buzzerul centralei semnnaleaza in felul urmator: Centrala detecteaza, semnaleaza si salveaza in memorie Stare Sunet Pauza Descriere urmatoarele erori de alimentare: iesiri 24V sau 24R in scurt, Baterie descarcata, Eroare baterie sau Lipsa Baterie. Atentie 2s 2 s beep-uri lente, interm. (LED-ul B a t t e r y si NoBattery). eroare impamantare, Prealarma 0,5s 0,5s beep intermitent LED E a r t h ) si lipsa alimentare retea (LED M a i n s ) Alarma 0,2s 0,2s beep-uri rapide, interm. (cid:1) Eroare 1s 1s beep-uri lente, interm. Erorile "NoBattery"sau"LowBattery " pot apa- rea cu o intarziere de pana la 1 minut. Eroarea Reset fara sunet "Mains" (portocaliu) va fi semnalata la expirarea Tes fara sunet intarzierii programate. Tabel 2 Semnale acustice Test Tasta LAMP - BUZZ - TEST permite TUTUROR utilizatorilor testarea Buzzerului si LED-urilor centralei. (cid:2)Acces la Semnale si Comenzi Sunt 4 nivele de acces, in conformitate cu Reglementarile de Incendiu in vigoare. Nivel Acces 1 (L1) Vizualizare: TOATE persoanele pot vizualiza starea Centralei (nu necesita parola). 8 Centrala de Incendiu Analogica FC500 IDENTIFICARE COMPONENTE LED-ul de stare Aceasta sectiune descrie functionarea LED-urilor centralei. In starea de asteptare, DOAR LED-UL VERDEMains si LED-ul Daymode (daca e in modul Day_) trebuie sa fie aprinse. (cid:1) DOAR daca ambele LED-uri FAULT palpaie ince-t exista o eroare inmemorie. LED-uri DESCRIERE FIRE Aprins indica stare de alarma. In acest caz, panoul activeaza iesirile de alarma care nu sunt in bypass. MoreAlarms Aprins indica mai multe stari de alarma. Pre-alarms Aprins indica stare de prealarma. Communicator Aprins indica activitate pe dispozitivul Telefonic. Pe display-ul centralei se poate afisa tipul (Rosu) conexiunii: PSTN, GSM sau retea LAN. FAULT Aprins indica prezenta unei erori: LED-urile corespunzatoare arata eroarea, sau apare un mesaj pe afisaj cu tipul erorii. Palpairea lenta indica o eroare in memorie (remediat prin Reset). LogicUnit Aprins indica o centrala blocata. IMPORTANT: Este necesara mentenanta. NOTA - la alimentarea centralei, acest LED palpaie pana la efectuarea primului reset. LostDevice Aprins indica lipsa unui dispozitiv pe bucla (lipsa adresa) Communicator Aprins indica dezactivarea apelatorului.Palpairea lenta indica o eroare de apelator. (Portocaliu) NacFire Aprins indica prezenta unei erori pe iesirea NAC FIRE. Palpairea lenta indica prezenta unei Output erori pe iesirea NAC FIRE. Earth Aprins indica o problema de impamantare. IMPORTANT:Verificati izolatia cablului. LowBattery Aprinsindica Baterie descarcata sau defecta. Daca problema persista, bateria nu va functiona corect in cazul unei pene de curent. IMPORTANT:Se instaleaza baterii noi. NOBattery Aprins indica baterie descarcata sau deconectata; verificati corectitudinea conexiunilor. MAINS Aprins indica lipsa Retea (230V) sau eroare Sursa in Comutatie. In aceasta conditie, Centrala (portocaliu) se alimenteaza din baterii. Daymode indica functionarea Centralei in modul Day (Zi) Stins indica functionarea Centralei in modul Night (Noapte). Disabled Aprins indica starea dezactivata a dispozitivelor bypass-abile. Silence Aprins indica starea iesirilor Silentioase, care au fost fortate pe standby prin tasta SILENCE. In modul DAY, modul Silentios va ramane activ pana la apasarea din nou a tastei SILENCE; in modul NIGHT, ramane activ pana la expirarea Timpului Silentios de Noapte. Test Aprins indica Conditii de Test pe cel putin o zona. MAINS STINS indica lipsa alimentare Retea (230V). (Verde) IMPORTANT:Alimentarea trebuie restabilita inainte de descarcarea bateriilor. Tabel 3 Descrierea LED-urilor de stare IDENTIFICARE COMPONENTE 9 1 a) 1 5 F1 F2 FIRE F3 FAULT F4 MOREALARMS LOSTDEVICE LBAUMZZP TEST 1 2 3 PRE-ALARM LOGICUNIT SILENCE ABC DEF GHI COMMUNICATOR COMMUNICATOR 4 5 6 DAYMODE NACFIREOUTPUT INVESTIGATE JKL MNO PQR DISABLED HEARTH SBIULZEZNECRE 7 8 9 SILENCE LOWBATTERY MIC RESET STU VWX YZ ESC TEST NOBATTERY EVACUATE ESC 0 FireClass MAINS MAINS 3 1 4 Figura 1 Panoul frontal al centralelor FC510,FC520(a), si al repetorului FC500REP (b)

Description:
ISO 9001. 9105.BNT1. ISO 9001. IT-52587. ISO 14001. 9191.BNT2. ISO 14001. IT-52588. FireClass. CENTRALA. ANALOGICA DE INCENDIU
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.