ebook img

IEC 60950-1 and/or EN 60950-1 (2 Edition - Archi-Europe PDF

65 Pages·2012·1.89 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview IEC 60950-1 and/or EN 60950-1 (2 Edition - Archi-Europe

IEC 60950-1 and/or EN 60950-1 (2nd Edition) Information technology equipment – Safety – Customer: Quantum Glass – Saint Gobain - France 4, Passage Sainte Avoye / 8 rue Rambuteau 75003 Paris France 110423-AU02+S01 Quantum Glass – Saint Gobain – France switching power supply SMPS 110VAC-S 80VA U The test result refers exclusively to the model tested. This report must not be copied without the written authorization by the lab. Registration number: DGA-PL-224/95-03 TEST REPORT IEC 60950-1 and/or EN 60950-1 (2nd Edition) / A11:2009 / A1:2010 Information technology equipment – Safety – Part 1: General requirements Report reference No . ..................... : 110423-AU02+S01 Tested by Richard Gierl (printed name and signature) .......... : ..................................................... Approved by Alexander Fischer (printed name and signature) .......... : ..................................................... Date of issue ................................... : 2012-07-18 Testing Laboratory Name ............. : EMV Testhaus GmbH Address ........................................... : Gustav-Hertz-Straße 35 Telephone: ...... +49 (0)9421-56868-0 D-94315 Straubing Fax: ................. +49 (0)9421-56868-100 Germany Applicant's Name .......................... : Quantum Glass – Saint Gobain - France Address ........................................... : 4, Passage Sainte Avoye / 8 rue Rambuteau .......................................................... : 75003 Paris France Test specification Standard ........................................... : IEC 60950-1:2005 (2nd Edition); Am 1:2009 and/or EN 60950-1:2006 / A11:2009 / A1:2010 Test procedure ................................ : CE conformity test Non-standard test method ............... : Test item description .................... : Switching Power Supply Trademark ....................................... : Quantum Glass – Saint Gobain - France Manufacturer ................................... : SCHIEDERWERK GmbH & Co.KG Model and/or type reference ........... : SMPS 110VAC-S 80VA U Serial number .................................. : *00015* Rating(s) ........................................... : Voltage: 110-240VAC / Frequency: 50-60 Hz / Current: 1.1-0.5 A EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 2 of 65 General product information: The EUT is a class I power supply unit. Equipment is single-phase alternating current supplied. Output voltage of PSU: 100V AC (secondary circuit with hazardous voltages) Equipment is for building-in. Copy of marking plate: EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 3 of 65 Summary of testing: Clause 1.5 Components ............................................................... : Pass Fail N/A N/T Clause 1.6 Power interface .......................................................... : Pass Fail N/A N/T Clause 1.7 Markings and instructions .......................................... : Pass Fail N/A N/T Clause 2.1 Protection from electric shock and energy hazards ... : Pass Fail N/A N/T Clause 2.2 SELV circuits .............................................................. : Pass Fail N/A N/T Clause 2.3 TNV circuits ................................................................ : Pass Fail N/A N/T Clause 2.4 Limited current circuits ............................................... : Pass Fail N/A N/T Clause 2.5 Limited power sources ............................................... : Pass Fail N/A N/T Clause 2.6 Provisions for earthing and bonding .......................... : Pass Fail N/A N/T Clause 2.7 Overcurrent and earth fault protection in primary Pass Fail N/A N/T circuits ........................................................................ : Clause 2.8 Safety interlocks ......................................................... : Pass Fail N/A N/T Clause 2.9 Electrical insulation .................................................... : Pass Fail N/A N/T Clause 2.10 Clearances, creepage distances and distances Pass Fail N/A N/T through insulation ....................................................... : Clause 3.1 Wirings ....................................................................... : Pass Fail N/A N/T Clause 3.2 Connection to an a.c. mains supply or a d.c. mains Pass Fail N/A N/T supply ......................................................................... : Clause 3.3 Wiring terminals for connection of external Pass Fail N/A N/T conductors .................................................................. : Clause 3.4 Disconnection from the mains supply ........................ : Pass Fail N/A N/T Clause 3.5 Interconnection of equipment ..................................... : Pass Fail N/A N/T Clause 4.1 Stability ....................................................................... : Pass Fail N/A N/T Clause 4.2 Mechanical strength ................................................... : Pass Fail N/A N/T Clause 4.3 Design and construction............................................. : Pass Fail N/A N/T Clause 4.4 Protection against hazardous moving parts ............... : Pass Fail N/A N/T Clause 4.5 Thermal requirements ................................................ : Pass Fail N/A N/T Clause 4.6 Openings in enclosures.............................................. : Pass Fail N/A N/T Clause 4.7 Resistance to fire ....................................................... : Pass Fail N/A N/T Clause 5.1 Touch current and protective conductor current ........ : Pass Fail N/A N/T Clause 5.2 Electric strength ......................................................... : Pass Fail N/A N/T Clause 5.3 Abnormal operating and fault conditions .................... : Pass Fail N/A N/T Clause 6 Connection to telecommunication networks .............. : Pass Fail N/A N/T Clause 7 Connection to cable distribution systems ................... : Pass Fail N/A N/T EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 4 of 65 Summary of testing (remarks): The product is in compliance with the requiremts of IEC/EN 60950-1. Particulars: test item vs. test requirements Equipment mobility ..................................... : Stationary Equipment Operating condition ..................................... : continuous Mains supply tolerance (%) ......................... : +6% / -10% Tested for IT power systems ...................... : Tested for TN system IT testing, phase-phase voltage (V) ........... : - - Class of equipment ..................................... : Class I Equipment Mass of equipment (kg) ............................... : 780g Protection against ingress of water ............ : IP20 Test case verdicts Test clause not tested ................................ : N/T Test case does not apply to the test object : N/A Test item does meet the requirement ........ : P(ass) Test item does not meet the requirement .. : F(ail) Testing Date of receipt of test item ......................... : 2012-06-05 Date(s) of performance of test ................... : 2012 week 27 EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 5 of 65 IEC 60950-1 and/or EN 60950-1 (2nd Edition) TEST REPORT No. Clause Remark Verdict P F N/A N/T 1 GENERAL X 1.5 Components X 1.5.1 General X Comply with IEC 60950-1 or relevant See appendend table X component standard 1.5.2 Evaluation and testing of components X 1.5.3 Thermal controls No Thermal control used X 1.5.4 Transformers (See Annex C) X 1.5.5 Interconnecting cables No interconnecting cables used X 1.5.6 Capacitors bridging insulation PrimSec / 2x Y2 / D or R X (C215,C216) Prim/Earth Y2 / B or S (C104, C105) Sec/Earth (CS308, CS309, CS507, CS508, CS500, CS506) 1.5.7 Resistors bridging insulation No such components X 1.5.7.1 Resistors bridging functional, basic or X supplementary insulation 1.5.7.2 Resistors bridging double or reinforced X insulation between a.c. mains and other circuits 1.5.7.3 Resistors bridging double or reinforced X insulation between a.c. mains and antenna or coaxial cable 1.5.8 Components in equipment for IT power X systems 1.5.9 Surge suppressors See annex Q X 1.5.9.1 General R1 X 1.5.9.2 Protection of VDRs VDR is protected by F1and F2 X 1.5.9.3 Bridging of functional insulation by a VDR VDR is bridging functional X insulation 1.5.9.4 Bridging of basic insulation by a VDR No bridging of a basic insulation X 1.5.9.5 Bridging of supplementary, double or No bridging of supplementary, X reinforced insulation by a VDR double or reinforced insulation 1.6 Power interface X EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 6 of 65 IEC 60950-1 and/or EN 60950-1 (2nd Edition) TEST REPORT No. Clause Remark Verdict P F N/A N/T 1.6.1 AC power distribution systems TN system is used. X 1.6.2 Input current see appended table 1.6.2. X 1.6.3 Voltage limit of hand-held equipment Equipment is not hand-held. X 1.6.4 Neutral conductor Functional insulation is used. X 1.7 Marking and instructions X 1.7.1 Power rating and identification markings X 1.7.1.1 Power rating marking X Multiple mains supply connections ............ : No multiple mains supply X connections. Rated voltage(s) or voltage range(s) (V) .. : 110-240 VAC X Symbol for nature of supply, for d.c. only .. : No d.c. supply. X Rated frequency or rated frequency range 50-60 Hz X (Hz) ........................................................... : Rated current (mA or A) ........................... : 1,1-0,4A X 1.7.1.2 Identification markings X Manufacturer’s name or trade-mark or Schiederwerk X identification mark Model identification or type reference SMPS 110VAC-S 80VAU. X Symbol for Class II equipment only Class I equipment. X Other markings and symbols : Considered X 1.7.2 Safety instructions and marking X 1.7.2.1 General Precautions in instruction. X 1.7.2.2 Disconnect devices Has to be considered in end X product. 1.7.2.3 Overcurrent protective device Overcurrent protection by F1, F2 X 1.7.2.4 IT power distribution systems TN-System used. X 1.7.2.5 Operator access with a tool Symbol Nr. 5036 is used X 1.2.7.6 Ozone No generation of ozone X 1.7.3 Short duty cycles Continuous rating. X 1.7.4 Supply voltage adjustment ..................... : No voltage adjustment. Full X range input. Methods and means of adjustment; X reference to installation instructions ........ : 1.7.5 Power outlets on the equipment .............. : No Power outlets on the X equipment. EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 7 of 65 IEC 60950-1 and/or EN 60950-1 (2nd Edition) TEST REPORT No. Clause Remark Verdict P F N/A N/T 1.7.6 Fuse identification (marking, special fusing F1, F2 on PCB (T 1,6A, 250V) X characteristics, cross-reference) ............ : 1.7.7 Wiring terminals X 1.7.7.1 Protective earthing and bonding terminals Symbol IEC 60417-5019 is used. X 1.7.7.2 Terminals for a.c. mains supply conductors Symbol N is used. X 1.7.7.3 Terminals for d.c. mains supply conductors Equipment is not connected to X d.c. mains supply. 1.7.8 Controls and indicators No such controls and indicators. X 1.7.8.1 Identification, location and marking ......... : X 1.7.8.2 Colours .................................................... : X 1.7.8.3 Symbols according to IEC 60417 ............ : X 1.7.8.4 Markings using figures ............................. : X 1.7.9 Isolation of multiple power sources ......... : Only one power source. X 1.7.10 Thermostats and other regulating devices .....N..o... .T : hermostats on the X equipment. 1.7.11 Durability The markings withstands the X required tests. 1.7.12 Removable parts No removable parts (only with X tools). 1.7.13 Replaceable batteries .............................. : No batteries on the equipment. X Language(s) ............................................ : X 1.7.14 Equipment for restricted access locations: Equipment is not intended for X use in r.a.l. 2 PROTECTION FROM HAZARDS X 2.1 Protection from electric shock and energy X hazards 2.1.1 Protection in operator access areas X 2.1.1.1 Access to energized parts See below. X Test by inspection ................................... : Equipment is for building-in. X Test with test finger (Figure 2A) ............. : Applied on enclosure. No access X to hazardous voltage parts. Test with test pin (Figure 2B) .................. : Equipment is for building-in. X Test with test probe (Figure 2C) ............. : No TNV circuits. X 2.1.1.2 Battery compartments No battery compartments. X EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 8 of 65 IEC 60950-1 and/or EN 60950-1 (2nd Edition) TEST REPORT No. Clause Remark Verdict P F N/A N/T 2.1.1.3 Access to ELV wiring No ELV wiring. X Working voltage (Vpeak or Vrms); X minimum distance through insulation (mm) 2.1.1.4 Access to hazardous voltage circuit wiring No hazardous voltage wiring. X Only PCB traces. 2.1.1.5 Energy hazards ....................................... : No energy hazards in operator X access area. 2.1.1.6 Manual controls No manual controls X 2.1.1.7 Discharge of capacitors in equipment X Measured voltage (V); time-constant (s) . : Primary under 60 V in 40ms, X secondary under 60 V in 260ms. 2.1.1.8 Energy hazards – d.c. mains supply No d.c. mains supply. X a) Capacitor connected to the d.c. mains X supply ..................................................... : b) Internal battery connected to the d.c. X mains supply ........................................... : 2.1.1.9 Audio amplifiers ...................................... : No audio amplifiers. X 2.1.2 Protection in service access areas Considered X 2.1.3 Protection in restricted access locations Equipment is not for use in r.a.l X 2.2 SELV circuits No SELV circuits. X 2.2.1 General requirements X 2.2.2 Voltages under normal conditions (V) .... : X 2.2.3 Voltages under fault conditions (V) ......... : X 2.2.4 Connection of SELV circuits to other X circuits ..................................................... : 2.3 TNV circuits No TNV circuits. X 2.3.1 Limits X Type of TNV circuits ................................ : X 2.3.2 Separation from other circuits and from X accessible parts 2.3.2.1 General requirements X 2.3.2.2 Protection by basic insulation X 2.3.2.3 Protection by earthing X 2.3.2.4 Protection by other constructions ........... : X EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 9 of 65 IEC 60950-1 and/or EN 60950-1 (2nd Edition) TEST REPORT No. Clause Remark Verdict P F N/A N/T 2.3.3 Separation from hazardous voltages X Insulation employed ................................. : X 2.3.4 Connection of TNV circuits to other X circuits Insulation employed ................................. : X 2.3.5 Test for operating voltages generated X externally 2.4 Limited current circuits No limited current circuits. X 2.4.1 General requirements X 2.4.2 Limit values X Frequency (Hz) ........................................ : X Measured current (mA) ............................ : X Measured voltage (V) .............................. : X Measured circuit capacitance (nF or µF) . : X 2.4.3 Connection of limited current circuits to X other circuits 2.5 Limited power sources No limited power sources. X a) Inherently limited output X b) Impedance limited output X c) Regulating network limited output under X normal operating and single fault condition d) Overcurrent protective device limited X output Max. output voltage (V), max. output X current (A), max. apparent power (VA) ... : Current rating of overcurrent protective X device (A) Use of integrated circuit (IC) current X limiters 2.6 Provisions for earthing and bonding X 2.6.1 Protective earthing Parts witch are seperated from X hazardous voltages are connected to protective bonding 2.6.2 Functional earthing No functional earhing X 2.6.3 Protective earthing and protective X bonding conductors EMV TESTHAUS GmbH Quantum Glass – Saint Gobain - France Gustav-Hertz-Strasse 35 94315 Straubing switching power supply / SMPS 110VAC S 80VA U Germany Revision 1.0 110423-AU02+S01 Page 10 of 65

Description:
Apr 1, 2014 Fail. N/A. N/T. Clause 2.3. TNV circuits The product is in compliance with the requiremts of IEC/EN 60950-1. Particulars: test item vs. Evaluation and testing of components. X. 1.5.3. Thermal controls. No Thermal control
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.