Health Smile Health Smile INTENDED USE OF Contents THE HY-7000UM PRODUCT To Migun Family, Intended purpose: Help to muscle relaxation therapy, Thank you for purchasing our HY-7000UM Thermassage Energy Product. temporary relief of minor and joint pain, stiffness. Please read this manual carefully for safe and effective use of your Migun. Please keep this manual safe and refer to it when necessary. GENERAL RISKS/ Intended Use 3 FIRST TIME USERS Contraindications 4 Important Safeguards 5 Whenever a new activity is introduced to the body there is a period of adjustment. General Warnings 6 This holds true with the HY-7000UM TherMassage Energy Product. First time users will Caution 8 go through a period of adjustment during the initial few weeks. of usage Every person Features of HY-7000UM 10 will react differently to the TherMassage Energy Product because of varying skin types, Package Contents 11 medical conditions, general health and other factors. Designations and Functional Characteristics - Parts 12 The TherMassage Energy Product is capable of heating up to 60 Celsius or 140 Designations and Functional Characteristics - Control Panel 14 Fahrenheit. Always wear clothing when using this product. Never expose bare skin to Remote Control 16 the heating devices of the TherMassage Energy Product. The manufacturer HY-7000UM Operation 18 recommends that first time users start at low temperatures and utilize the automatic Operational Modes 21 mode of the device. You can slowly build up tolerance to the heat, and gradually Frame Assembly 28 increase temperatures over a several week period. Specifications 30 Preparing to Use 31 Individuals with reactive skin disorders such as heat rash, photo allergenic dermatitis, To confirm normal setting 33 prickly heat, or excessive allergy should consult their physician before commencing To confirm normal operation 34 sessions, as the heating elements may exaggerate trigger these conditions. Use of a natural skin lotion after a massage may help alleviate skin irritations. Moreover, the roller Operational Instructions 35 systems in the TherMassage Energy Product may seem uncomfortable for first-time Proper Storage and Care 48 users. Again, this will be rectified over time as the body gets used to the device. Some Error Message/Emergency 49 people have found that elevating the spine slightly (using shoulder and stomach Troubleshooting 50 muscles) will aid comfort during the initial uses of the product. Exanpandable Items 51 Replacing Replacement Items 52 IF YOU EXPERIENCE ANY OF THE ABOVE SYMPTOMS WHILE USING THE Disposing Used Product / Manufacturer's Label 53 THERMASSAGE ENERGY PRODUCT, IT IS RECOMMENDED THAT YOU Warranty Registration 54 IMMEDIATELY DISCONTINUE USE AND CONSULT YOUR PHYSICIAN. Memo 57 HY-7000UMOwners Manual Healthy Smile Healthy Smile IMPORTANT CONTRAINDICATIONS SAFEGUARDS DO NOT USE THE HY-7000UM IF ANY OF THE FOLLOWING CONDITIONS EXIST: Please read this section carefully before using the product. Follow 1. Phlebitis these safeguards as they are for your own safety. 2. Individuals with fused discs or implanted scoliosis rods 3. Individuals with diagnosed Osteoporosis SAFETY SYMBOLS 4.Fractures or suspected fractures The symbols and boxes shown below explain what each heading means. 5. Individuals with any type of metallic implants Read and follow all of the messages found throughout the manual. 6. Pacemaker or ICD "Internal Cardiac Device" Individuals with reactive skin disorders such as heat rash, photo allergic dermatitis, prickly heat or allergies should use this product with caution, and consult their physician, prior to use. Be alert to the possibility of serious They indicate a potentially hazardous injury or death if the instructions are situation which, if not avoided, may WOMEN: IF YOU ARE PREGNANT, DO NOT USE THIS PRODUCT. not followed. Be sure to read and result in minor injury, damage to the carefully follow all of the messages. equipment, or property damage. Call for This product should only be serviced by a After service qualified technician. Do not disassemble, repair or modify the product. Procedures other than those described in this manual mustbe performed only by a qualified technician SAVE THESE INSTRUCTIONS The contents of this manual may change without notice 4 HY-7000UMOwners Manual HY-7000UMOwners Manual 5 Healthy Smile Healthy Smile The warnings and cautions are provided for users in order to operate our products safely. GENERAL WARNINGS Please follow the instructions to avoid any potential injury. The symbols specify a particular condition or operation which may cause possible injury, property damage, or damage to the product. Operation and Location If any problems occur during use of the product, stop using it immediately GENERAL WARNINGS and contact your Migun Dealer. The HY-7000UM TherMassage Energy Product has a weight limit of 382 lbs. Do not use the HY-7000UM TherMassage Energy Product in Power Connection and Installation an environment of extreme cold or heat (< 104℉or > 140℉). Avoid direct sunlight. The product has an electrical rating of 120V AC 60Hz. Do not attempt to service or repair the product by yourself. Make sure to connect the product to a proper outlet; Do not use the product if a connection cable is damaged. otherwise, electrical shock or a short circuit may occur. Do not remove any bulbs from the thermomechanical probes and projectors. Do not unplug the product by pulling on the power cord. Contact your Migun Dealer if you need a replacement. Keep the power cord plug clean. Do not expose the product to water or wet conditions. Do not use the product if the power cord is frayed or damaged. Do not remove the mattress from the frame during operation. A damaged cord may cause electrical shock, or a short circuit. To avoid injury, keep your hands away from internal parts. Do not attempt to replace a damaged power cord yourself. Contact your Always wear clothing when using this product. local Migun dealer for replacement. Never expose bare skin to the heating devices of the If an extension cord is used, be sure it has HY-7000UM TherMassage Energy Product. the proper electrical rating (120V AC, 15A). It is important that you do not doze off, or sleep while you as using this product. To avoid electrical shock, unplug the power cord before cleaning The heat may result in a burn if not properly monitored. the product. Lower the temperature setting if the heat becomes uncomfortable for you. Do not plug or unplug the product if your hands are wet. Keep children away from the product at all times. Do not let them play on or Use only the accessories provided to ensure that the around the product, as they may become injured. HY-7000UM works properly. Please restrict use of the Thermassage Energy Product to areas where electromagnetic waves are generated, if possible. 6 HY-7000UMOwners Manual HY-7000UMOwners Manual 7 Healthy Smile Healthy Smile Operation and Location Before using this product DO NOT USE THE HY-7000UM IF ANY OF THE FOLLOWING CONDITIONS This equipment is not suitable for use in the presence of FLAMMABLE ANAESTHETIC MIXTURE WITH AIR OR WITH OXYGEN OR EXIST: NOTROUS OXIDE; Not category AP or Category APG EQUIPMENT. 1.Phlebitis Keep sharp objects away from the product. 2.Individuals with fused discs or implanted scoliosis rods. Sharp objects may cut the upholstery and cause damage. 3.Individuals with diagnosed Osteoporosis. 4.Fractures or suspected fractures. Do not place anything on the product, when it is not being used. 5.Individuals with any type of metallic implants. 6.Pacemaker or ICD Ò"IInntteerrnnaall CCaarrddiiaacc DDeevvicicee."Ó. Do not eat or drink while using the product. 7.Diagnosed heart disease or suspected heart disease. Keep liquids away from the product to avoid spillage, which may cause damage to the product. Follow the recommendations of your physician for use of this product. Do not use the product near a heating device or heat vent. Consult with your physician before use if you have: -reactive skin disorders such as heat -photo allergic dermatitis -prickly heat or exercise allergy -malignant tumors -high fever -visual problems -artificial organs or skeletons IF YOU ARE PREGNANT, DO NOT USE THIS PRODUCT. Migun recommends that you use this product no more than 4 times a day. If you use this product more than once per day, allow 4 hours between each use. Do not use the external probes near or around your eyes or in the facial area. Do not use the external probes for more than 2 minutes on one specific area of the body. Be sure to properly position yourself on the bed during use, or some discomfort may occur. Your head should be approximately 3" to 3 1/2" from the top edge of the mattress, when using the product. 8 HY-7000UMOwners Manual HY-7000UMOwners Manual 9 Healthy Smile Healthy Smile Features of HY-7000UM Package Contents Features of HY-7000UM The treatment area of the main body has been designed to cover from the base of the skull to below the tail bone. The treatment area of the lower body has been designed Main body Lower Body to cover from the thigh to the ankle, thereby treating the entire body. Users can choose from eight operational modes. (Refer to operational modes on pages 18 through 27.) 2-Way Jade 7-Way Jade 15-Way Jade Thermomechanical Projector Thermomechanical Projector Thermomechanical Projector The external projectors can be applied on desired areas. (Sold Separately) Depending on the selected operational mode, moving speed of the internal thermomechanical probes change between low, moderate, and high settings. A simple click of the remote control makes Power Cord Connecting Cable the operation easy and quick. Remote Supporting Frame for (AC 250V) for Main and Lower Bodies Control Main and lower bodies The specialized functions can be operated with a handheld remote control, with the operational status confirmed through an LCD window. Cloth Cover Owner's Manual Product Catalogue 10 HY-7000UMOwners Manual HY-7000UMOwners Manual 11 Healthy Smile Healthy Smile Designations and Functional Characteristics - Parts Connection Terminals Remote Control It controls temperature settings and movements of all thermomechancal It contains terminals for the lower body, probes and projectors. power suppy, external thermome- It can be easily stored in the chanical projectors, and remote control. supporting frame. Cloth Cover Lower Body It protects the internal thermome- Two internal thermomechanical chancal probes and can be detached probes provide a thermal and for cleaning. masssage treatment to your lower body based on the chosen operational mode. Supporting Frame for Main and lower bodies Main Body Two internal thermomechanical probes provide a thermal and masssage treatment to your Main Power Panel upper body according to the operational mode. External Jade Thermomechanical Projectors Main power switch is They provide a thermal treatment to any located here. desired area of the body. 12 HY-7000UMOwners Manual HY-7000UMOwners Manual 13 Healthy Smile Healthy Smile Designations and Functions - Control Panel Main body Label Panel Power Connection Panel Main Power Switch: Turns the product on or off. 120V Lower Body Label Panel Connection terminal Power Terminal Connects to the Connects to an lower body AC 120V outlet 442-42 Chungyeon-Ro Yeondong-Myeon, Sejong 30068 Republic of Korea External Projector Remote Control Terminal Connection terminal: Connects to the main body Terminal 1 Connects to the Connects to the 2-way remote control External Projector projector Terminal 2 14 HY-7000UMOwners Manual Connects to the 15-way HY-7000UMOwners Manual 15 projector Healthy Smile Healthy Smile Remote Control Composition of the LCD window LCD window Composition of the LCD window PPOOWWEERR bbuuttttoonn TEMP control button MODE button RUN button MOVE button STOP button M.F (Manual function) button PAUSE button P8 button EXTERNAL Jade button 16 HY-7000UMOwners Manual HY-7000UMOwners Manual 17 Healthy Smile Healthy Smile HY-7000UM Operation The HY-7000UM Thermassage Energy Product provides both heat and massage Massage Therapy therapy. You can choose from 7 automatic operational modes, or you can use the product in Sectional Massage Mode the manual mode. During sectional massage therapy, thermomechanical probes move from the The automatic modes will deliver a combination of therapies to specific areas of the starting point of the massage location to a specific area of the body-and then stop. body, for a predetermined amount of time. The manual mode allows you to They then move back and forth slightly for a few seconds before moving to the position the thermomechanical probes manually, and apply therapy to the area next stopping point in the cycle. When the next stopping point is reached, they will selected. again move back and forth slightly for a few seconds, then move to the next A complete description of the therapies, operational modes, and treatment areas is stopping point. provided below. This will continue, until the entire massage session has been completed. As with the full massage, the infrared lamps on the thermomechanical probes apply heat therapy during the treatment. Heat Therapy Heat therapy is provided using infrared helium lamps. The lamps are mounted to Acupressure Therapy Acupressure therapy is when the thermomechanical probes are stopped and not jade thermomechanical projectors, which are under the pads of the main body and moving. lower body of the table. The lamps have a temperature range of 40 to 60 In this position, the weight of your body on the stationary thermomechanical (104 to 140 ). probes result in natural pressure to the area of the body where the They may be adjusted in 5 increments using the remote control. thermomechanical probes are located. If a specific temperature is not selected, the system automatically defaults to 50 This is somewhat similar to a physical therapist using the thumbs or palms of the hands, to apply pressure to a specific part of the body. Heat therapy is provided by the helium infrared lamps during this type of treatment as well. Massage Therapy There are three different types of massage therapy: Treatment Areas Full Massage Therapy, Sectional Massage Therapy, and Acupressure Therapy. Treatment areas are the parts. of the body in which the operational modes apply Full Massage the treatment. During full massage therapy, the thermomechanical probes move slowly from the While the exact location of the treatment varies somewhat depending on your starting point of the massage location to the end point of the massage location, height, the area of treatment is essentially the same for most people. without stopping. Throughout the cycle, light massage pressure is applied to the area of the body in The product has four different treatment areas in the automatic operational one continuous motion, for a specific period of time. modes. These are, Full Upper Body, Upper Back, Lower Back, and Abdomen. The helium infrared lamps on the thermomechanical probes also apply heat The lower body has one treatment area which is Lower Body. The chart below therapy during this type of treatment. describes the location of each treatment area . 18 HY-7000UMOwners Manual HY-7000UMOwners Manual 19 Healthy Smile Healthy Smile HY-7000UM Operation Operational Modes Treatment Areas, Main Body Section of the Table Operational modes provide a combination of heat therapy, massage therapy, and Description Treatment Area acupressure for a predetermined periods of time. The operational modes focus on different treatment areas of the body as Full Upper Body Base of the Skull to the 2-3" Below the Tail Bone described below. Upper Back Base of the Skull to the Middle of the Back Lower Back Middle of the Chest to 2 -3" Below the Tail Bone 1. Operational Mode P1-Full Massage Abdomen Middle of the Back to 2-3" Below the Tail Bone In this mode, the main body section of the table automatically applies a Lower Body From the Mid-thigh Area to Mid-ankle Area combination of heat therapy, full body massage, sectional massage, and Also note that the treatment area of the lower body section of the HY-7000UM acupressure treatment on the entire upper body. may be adjusted to cover a larger area of the lower body to accommodate taller At the same time, the lower body section provides heat, full massage, and users. acupressure to the lower body area. This adjustment must be made only by qualified Migun personnel. The sequence of the session for the main body is: Contact your Migun Dealer if you wish to have this larger treatment area. 1.Sectional massage of the upper body 2.Full body massage of the upper body 3.Acupressure therapy of the upper body 4.Repeat of the Steps 1 through 3 5.Full body massage of the upper body The sequence of this session for the lower body section is: 1.Full massage of the lower body 2.Heat and acupressure of the lower body The thermomechanical probes in the main body will stop at 34 different locations during the session, when applying acupressure and sectional massage therapy. The thermomechanical probes in the lower body will stop at 14 locations. The lower body massage sequence will repeat itself continuously, until the operation in the main body section stops. 20 HY-7000UMOwners Manual HY-7000UMOwners Manual 21
Description: