ebook img

Heating with airborne and geothermal heat (PDF 5 MB) PDF

70 Pages·2017·4.99 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Heating with airborne and geothermal heat (PDF 5 MB)

TECHNOLOGY BROCHURE Heating with airborne and geothermal energy: VITOCAL Vitocal heat pumps The perfect way to utilise renewables 2 / 3 INTRODUCTION sustainable environmentally responsible renewable valuable individual Heat pumps utilise renewable energy from the ground, sun, groundwater and air. This means they lower the consumption of fossil fuels, conserve valuable resources and reduce CO emissions that damage 2 the environment. Another benefit is that many of the heat pumps from Viessmann feature active and natural cooling functions. Alongside their classic application as heat generators on cold days, they can also create a pleasantly cool ambience in summer. Our extensive range offers the ideal heat pump to suit every requirement – individually matched to structural and geological conditions, as well as heat demand. Running a heat pump with power generated on site by a photovoltaic system is particularly environmentally responsible and cost effective. Ideal for new build and modernisation: Viessmann heat pumps can be operated with solar thermal or photovoltaic systems, and in conjunction with an existing oil or gas heating system. This allows every building and property owner to realise their individual ideas. 4 / 5 TABLE OF CONTENTS Heat pumps from Viessmann offer tailor-made solutions for heating and cooling, as well as a convenient hot water supply, for both new build and modernisation projects. 6 SAVE ENERGY AND PROTECT THE CLIMATE By modernising your heating system, you are making an active contribution towards protecting the climate and 6 saving fossil fuels. 12 BRINE/WATER HEAT PUMPS Brine/water heat pumps use the ground as their primary energy source, either with geothermal collectors or geothermal probes. 34 AIR SOURCE 12 34 HEAT PUMPS Air source heat pumps utilise outdoor air or extract air as their primary energy source. 66 SYSTEM TECHNOLOGIES DESIGNED TO WORK TOGETHER System technology from Viessmann perfects your new heating system: Vitotronic control units and Vitocell DHW cylinders, as well as high grade solar technology, for cost effective DHW heating and central heating backup. 70 SERVICE THAT COVERS EVERY ASPECT OF 66 HEATING Viessmann trade partners can advise you on everything you need to know about innovative heating technology, available subsidies and finance options, without obligation and free of charge. 72 72 THE COMPANY The Viessmann family business is a leading international manufacturer 70 of efficient energy systems. 6 / 7 HOW IT WORKS Energy from the ground Energy from the ground (collector) (collector) 1 2 3 1 2 3 Energy from the ground, the air and the sun Energy from groundwater (Vitofriocal ice store system) 5 4 1 2 3 1 2 3 Energy from the air Energy from the air (with outdoor unit) 6 1 3 1 2 3 2 1 Vitocal heat pump 4 Ice store 2 DHW cylinder 5 Solar/air absorber 3 Heating water buffer cylinder 6 Outdoor unit The air, ground, water and waste heat are primary energy sources that are practically free and can be used to run a heat pump system efficiently. Heat pump Compression process A heat pump works like a refrigerator, just in reverse. While a refrigerator directs heat to the outside, heat pumps take energy from the air or the ground 65 °C and transfer it into the living space via the heating system. The transfer medium carrying the heat drawn from the environment is compressed in Getting hotter towards the centre: from an initial temperature of order to reach the flow temperatures between 5 and 18 °C, a flow temperature of up to 65 °C is reached. necessary for different heating systems. For example, a heating system with radiators requires temperatures of up to 65 °C. Underfloor heating systems, however, manage with a flow temperature of 30 °C. This makes heat A heat exchanger transfers the energy Annual COP pumps suitable for both modernisation from the heated gas to the heating When designing a system, it is and new build. circuit. The refrigerant, which is still necessary to consider its likely use under pressure, condenses again and over an entire year. To do this, the State of the art compressor is expanded in an expansion valve. amount of heat delivered is compared technology for the highest The cycle then begins again. with the total electricity demand of level of efficiency the heat pump system. This includes The compression process is critical Usage with various the power drawn by pumps and to the efficiency of a heat pump. energy sources control units, etc. The result is referred Viessmann uses the most advanced The best energy source for each to as the annual COP (coefficient of components in its heat pumps. They individual case depends on local performance). are characterised by quiet operation, conditions and the actual heat demand. low vibrations and an extremely long Viessmann heat pumps can use The annual COP is the ratio of heat service life, without the need for various energy sources: transfer to power consumption. The _ maintenance. Air – unlimited availability; lowest higher this coefficient, the more investment outlay efficiently the heat pump is working. _ To generate heat, thermal energy Ground – via geothermal collector, is extracted from the environment geothermal probe or ice store; very and used to evaporate a refrigerant efficient _ that boils at a low temperature. The Water – extremely efficient; compressor compresses the gas observe water quality _ this creates and raises it to a higher Waste heat – subject to availability, temperature level. amount and temperature level 8 / 9 CONNECTIVITY The quick and easy way to save energy and enjoy the benefits of convenience and reassurance. The ViCare app offers new possibilities System status Connect the module to the internet for controlling heating systems via at a glance and register via plug & play. Simply the internet. The design of the ViCare Green for go – the user can see at a scan the supplied QR code using a graphic interface has been kept simple, glance whether their heating system smartphone. enabling completely intuitive heating is working as it should. Yellow lets system operation. you know about a pending service and Vitoconnect is compatible with mobile red automatically offers to contact the devices and operating systems iOS 8.0 Save energy contractor. and Android 4.4 or higher. Control automatically LEDs indicate data communication The system is designed to control To enable this function, simply store between the boiler and the internet. one heating circuit. You can set the the contact details of the contractor. required room temperature via the Of course, the system user has the touchscreen, and switch between final decision on whether to allow the standard and party mode ("Extended contractor to monitor their heating heating") with a single tap. system using the specially developed Vitoguide app. When leaving the house ("Away"), it takes just one command to reduce the Vitoconnect is the interface between heating system temperature and save the heat generator and ViCare. It is energy. Anyone wanting to program connected directly to the Vitotronic different switching times for each day control unit via a cable. A plug-in power will appreciate the assistant function. supply unit is included in the standard delivery. The small adaptor, measuring A separate button on the home screen only 10 x 10 cm, is designed for wall also shows numerous tips for saving mounting. energy. Explanation in brief ViCare accesses the Vitoconnect online interface to control the heat generator. Once the system user has given their consent, the contractor can use Vitoguide to keep a constant eye on their customer's system. Vitoconnect with sockets for the plug-in power supply unit (left) and data connection ViCare 5 year guarantee WiFi WiFi Vitoconnect with system web connection/ connectivity Heat generator For conditions, see www.viessmann.de/garantie Vitoguide REASSURANCE ECONOMY Warmth and Simply set your preferred reassurance: temperature – save costs when you're not at home: + Green for go – see at a + glance whether everything Straightforward, convenient is OK operation of the heating + Be informed about a system + pending service Record your daily routine + Direct access to the and automatically save on address of the saved energy costs + contractor Set standard functions with one tap of a button on your smartphone SUPPORT A direct link to the contractor – just in case: + Simply store your contractor's details + Quick and effective assistance – the contractor has all of the important information Simply download the app and tap + All-inclusive carefree safety and maintenance "Discover ViCare" on the app's start screen – and off you go, with no need package for an actual heat generator or internet connection. 10 / 11 PRODUCT OVERVIEW BRINE/WATER HEAT PUMPS Heat Application Cooling 1.7 to 42.8 kW g n e Ground Water Ice store system Detached house Apartment buildi Commercial premises High temperatur Integral DHW cylinder NC AC Page VITOCAL 333-G 12 1.7 to 11.4 kW VITOCAL 222-G 16 5.8 to 10.4 kW VITOCAL 300-G 18 5.7 to 17.2 kW VITOCAL 200-G 22 5.6 to 34.4 kW VITOCAL 350-G 24 20.5 to 42.3 kW VITOCAL 300-G 28 21.2 to 42.8 kW + Accessories required

Description:
Air source heat pumps utilise outdoor air or extract air as a Brine/water heat pumps use the ground as primary energy characteristic value .. Vitocal 300-G: low operating costs with the highest level of efficiency at any operating point thanks Easier placement thanks to small and light modules
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.