ebook img

Harvard Apparatus Pump 11 Elite - Instech Laboratories, Inc. PDF

71 Pages·2010·2.08 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Harvard Apparatus Pump 11 Elite - Instech Laboratories, Inc.

Pump 11 Elite & m o Pump 11 Pico Plus Elite c . s USER’S MANUAL u t a r a p p a d r a v r a Harvard Apparatus Pump 11 Elite h & Pump 11 Pico Plus Elite Series . w Publication5420-002RevB w w 800.272.2775 phone [email protected] email Table of Contents 2 P Table of Contents u SUBJECT PAGENO. m General Information................................................................................................6 p Safety Information..................................................................................................6 1 Warranty and Repair Information ..........................................................................7 1 Manual Description ....................................................................................7 E Warranty......................................................................................................7 l i Repair Facilities and Parts ..........................................................................7 t e Serial Numbers............................................................................................7 & Calibrations..................................................................................................7 Specifications ........................................................................................................8 P i Product Overview....................................................................................................9 c o Pump Models ......................................................................................................10 Pump 11 Elite Series Touch Screen Button Reference........................................11 P Selecting an Item from a Menu List ....................................................................12 l u Messages ............................................................................................................12 s Entering Values ....................................................................................................12 Operating Instructions..........................................................................................13 U Power Connections..............................................................................................13 S E Syringe Loading....................................................................................................14 R ’ S Configuring the Pump 11 Elite Series..................................................................15 M Method Selection ................................................................................................15 A Syringe Selection..................................................................................................16 N Flow Rate Selection ............................................................................................17 U A Target Volume/Time Selection..............................................................................18 L Previewing the Quick Start ..................................................................................19 Configuring the Pump’s General Parameters ......................................................19 Setting the Audible Alarms ..................................................................................20 For Near End of Run Selection..................................................................21 For a Custom ............................................................................................21 Locking the Touch Screen ........................................................................22 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com web Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB Table of Contents 3 P SUBJECT PAGENO. u Setting the Password................................................................................22 m Turning the Touch Screen Lock on............................................................22 p Turning the Touch Screen Lock off............................................................22 Setting the Force Limits............................................................................23 1 1 Setting Display Backlight ..........................................................................24 Setting the Pump Address........................................................................25 E l Setting the Baud Rate ..............................................................................25 i t Power-Up Running....................................................................................26 e Setting and Viewing Pump Information ....................................................26 & Tilt..............................................................................................................27 P Operating the Pump 11 Elite Series ....................................................................28 i c Running the Pump................................................................................................28 o Custom Method Workflow ..................................................................................29 P Configuring Custom Methods..............................................................................31 l Configuring a New Custom Method....................................................................31 u s Configuring Custom Methods..............................................................................32 Setting a Delay ....................................................................................................33 U Creating a New Custom Method ........................................................................34 S To Create a New User-Defined Method....................................................34 E R Modifying an Existing/User-Defined Method ......................................................36 ’ S Changing the Order of Steps in a Method................................................36 M Deleting a Step from a Method ................................................................36 A Defining Method Step Parameters ......................................................................36 N Pump Operation Profiles......................................................................................37 U A Constant Rate Profile................................................................................38 L Ramp Profile..............................................................................................39 Gradient Profile..........................................................................................40 Autofill Cycling Profile ..............................................................................42 Incorporating Advanced Options Into a Method..................................................43 Delay ........................................................................................................44 Repeat Step ..............................................................................................44 Stop ..........................................................................................................44 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com web Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB Table of Contents 4 P SUBJECT PAGENO. u I/O Event Triggers ................................................................................................45 m I/O Trigger (OUT) ......................................................................................45 p I/O Event (IN) ............................................................................................46 1 Managing Pump 11 Elite Series Methods............................................................47 1 Saving a Copy of a Method ......................................................................47 E Renaming a Method..................................................................................47 l i Appending a Method ................................................................................47 t e Deleting a Method ....................................................................................47 Method Import and Export ..................................................................................48 & Exporting a Method to an External Computer ..........................................49 P Importing a Method from an External Computer......................................49 i c External Pump Control ........................................................................................50 o Setting up HyperTerminal..........................................................................50 P Pump Chain Commands ......................................................................................51 l u Using the Pump 11 Elite Series Pump Chain Commands ........................51 s Error Messages ........................................................................................52 Command Errors ......................................................................................52 U Argument Errors........................................................................................52 S E System Commands ..................................................................................52 R ’ Run Commands ........................................................................................54 S M Rate Commands........................................................................................54 A Volume Commands ..................................................................................55 N Time Commands ......................................................................................56 U A Digital I/O Commands ..............................................................................57 L Internal Commands ..................................................................................57 Serial Command Notes ............................................................................57 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com web Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB Table of Contents 5 P SUBJECT PAGENO. u Appendices ............................................................................................................58 m Appendix A: Syringe Volume/Diameter Reference Table ....................................58 p Appendix B: Min/Max Flow Rates........................................................................59 1 Appendix C: External Connections ......................................................................60 1 User I/O Connector Specifications............................................................60 E Utilizing USB Interface..............................................................................61 l RS-485 ......................................................................................................63 i t Legacy RJ-11 Option ................................................................................64 e Appendix D: Maintenance....................................................................................65 & Maintenance..............................................................................................65 P Upgrading Pump 11 Elite Series Software................................................66 i c Troubleshooting ........................................................................................67 o Appendix E: Ordering Information........................................................................68 P l u s U S E R ’ S M A N U A L 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com web Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB Table of Contents 6 P General Information u m SAFETY INFORMATION p Pleasereadthefollowingsafetyprecautionstoensureproperuseofyoursyringepump.Iftheequipmentisusedina 1 mannernotspecified,theprotectionprovidedbytheequipmentmaybeimpaired. 1 To Prevent Hazard or Injury: E USE PROPER POWER SUPPLY l Thepumpissuppliedwithanapprovedpowersupplyandlinecord.Tomaintainthesafetyintegrityofthedevice,use i onlythefollowingpowersupplies: t e CuiInc. GlobtekInc. Model: 3A–242DB24 Model: GT–41062–T3 & Output: 24V–1.0A Output: 24V–0.75A Input: 100–240V~50–60Hz0.8A Input: 100–240V~50–60Hz0.6A P USE PROPER LINE CORD i Useonlythespecifiedlinecordforthisproductandmakesurelinecordiscertifiedforcountryofuse.Theoperating c voltagerangeforthePump11EliteSeriesis12-30VDC.Theuniversalpowersupplyoperatingvoltagerangeis o 100-240VAC,50/60Hz. GROUND THE PRODUCT P Thisproductisgroundedthroughthegroundingconductorofthepowercord.Toavoidelectricshock,thegrounding l conductormustbeconnectedtoearthground.Beforemakinganyconnectionstotheinputoroutputterminalsofthe u product,ensurethattheproductisproperlygrounded. s MAKE PROPER CONNECTIONS Makesureallconnectionsaremadeproperlyandsecurely.Anysignalwireconnectionstotheunitmustbenolongerthan3 meters. U OBSERVE ALL TERMINAL RATINGS S E Reviewtheoperatingmanualtolearntheratingsonallconnections. R AVOID EXPOSED CIRCUITRY ’ S Donottouchanyelectroniccircuitryinsideoftheproduct. M AVOID PINCH HAZARD Apinchhazardmayexistbetweenthepusherblockandendblocks.Avoidplacingfingersbetweenthesepointswhile A thepumpisrunning. N U DO NOT OPERATE WITH SUSPECTED FAILURES A Ifdamageissuspectedonortotheproductdonotoperatetheproduct.Contactqualifiedservicepersonneltoperform inspection. L ORIENT THE EQUIPMENT PROPERLY Donotorienttheequipmentsothatitisdifficulttooperatethedisconnectiondevice. PLACE PRODUCT IN PROPER ENVIRONMENT Reviewtheoperatingmanualforguidelinesforproperoperatingenvironments. OBSERVE ALL WARNING LABELS ON PRODUCT Readalllabelsonproducttoensureproperusage. ! CAUTION Protective RefertoManual GroundTerminal 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com web Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB General Information 7 P WARRANTY AND REPAIR INFORMATION u CAUTION:REFERTOSAFETYINFORMATIONANDSETTINGUPTHE m ! HARVARDAPPARATUSPUMP11ELITESERIESBEFOREPLUGGINGIN THEPUMP. p 1 Manual Description 1 ThismanualisdesignedtoprovidealloperationalandMethodinformationrequiredtooperateandmaintainthe E Pump11EliteSyringePumps.ThefunctionsandfeaturesaredescribedintheTechnicalSpecificationssection. l i t Warranty e HarvardApparatuswarrantiesthisinstrumentforaperiodoftwoyearsfromdateofpurchase.Atitsoption, HarvardApparatuswillrepairorreplacetheunitifitisfoundtobedefectiveastoworkmanshipormaterials. & Thiswarrantydoesnotextendtodamageresultingfrommisuse,neglectorabuse,normalwearandtear,or accident.Thiswarrantyextendsonlytotheoriginalconsumerpurchaser. P INNOEVENTSHALLHARVARDAPPARATUSBELIABLEFORINCIDENTALORCONSEQUENTIAL i DAMAGES.Somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamagessothe c abovelimitationorexclusionmaynotapplytoyou.THEREARENOIMPLIEDWARRANTIESOF o MERCHANTABILITY,ORFITNESSFORAPARTICULARUSE,OROFANYOTHERNATURE.Somestatesdonot allowthislimitationonanimpliedwarranty,sotheabovelimitationmaynotapplytoyou. P Ifadefectariseswithinthewarrantyperiod,promptlycontactHarvardApparatus,84OctoberHillRoad, l Holliston,Massachusetts01746usingouttollfreenumber1-800-272-2775oroutsidetheUScall1–508-893- u 8999.Emailaddressisbioscience@harvardapparatus.com.GoodswillnotbeacceptedforreturnunlessanRMA s (returnedmaterialsauthorization)numberhasbeenissuedbyourcustomerservicedepartment.Thecustomeris responsibleforshippingchargesfornon-warrantyrepairs.Pleaseallowareasonableperiodoftimeforcompletion ofrepairsorreplacement.Iftheunitisreplaced,thereplacementunitiscoveredonlyfortheremainderofthe originalwarrantyperioddatingfromthepurchaseoftheoriginaldevice. U Thiswarrantygivesyouspecificrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate. S E R Repair Facilities and Parts ’ S HarvardApparatusstocksreplacementandrepairparts.Whenordering,pleasedescribepartsascompletelyas M possible,preferablyusingapartnumberobtainedfromourTechnicalSupportdepartment.Ifpractical,enclosea samplepartorsketch.Weofferacompletereconditioningservice. A N Serial Numbers U A Allinquiriesconcerningourproductshouldrefertotheserialnumberoftheunit,locatedontherearpanel. L Calibrations Allelectricalapparatusarecalibratedatratedvoltageandfrequency.Whiletheflowandvolumewillstaycalibrated, thepeakpressuremayvary.HarvardApparatusrecommendsanannualcalibrationofthepump. CAUTION:FORRESEARCHUSEONLY.NOTFORCLINICALUSEON ! PATIENTS. 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com web Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB General Information 8 Specifications Pump 11 Elite Pico Plus Elite P Accuracy ±0.5% ±0.35% u Reproducibility ±0.05% ±0.05% m Syringes(Min./Max.) 0.5µl/60ml(10mldual) 0.5µl/10ml FlowRate: p Minimum(0.5µlsyringe) 1.28pl/min 0.54pl/min 1 Maximum(10mlsyringe) 25.99ml/min 11.70ml/min 1 Maximum(60mlsyringe) 88.28ml/min N/A Display 4.3"WQVGATFTColorDisplaywithTouchScreen 4.3"WQVGATFTColorDisplaywithTouchScreen E Non-VolatileMemory Storesallsettings Storesallsettings l Connectors: i t RS-485 IEEE-1394,6pos IEEE-1394,6pos e USB TypeB TypeB I/O&TTL 15pinD-SubConnector 15pinD-SubConnector & Footswitch miniphonojack miniphonojack LinearForce(Max) 16kg(35lbs)@100%ForceSelection 16kg(35lbs)@100%ForceSelection P DriveMotor 0.9°StepperMotor 0.9°StepperMotor i c MotorDriveControl Microprocessorwith1/16microstepping Microprocessorwith1/16microstepping o NumberofMicrosteps 15,360 20,480 peronerev.ofLeadScrew P StepResolution 0.069µm/µstep 0.031µm/µstep l StepRate: u Minimum 27.5sec/µstep 27.5sec/µstep s Maximum 26µsec/µstep 26µsec/µstep PusherTravelRate: Minimum 0.15µm/min 0.02µm/min U Maximum 159.00mm/min 71.55mm/min S InputPower 12-30VDC 12-30VDC E R InputPowerConnection 2.5mmIDx5.5mmODmaleplug 2.5mmIDx5.5mmODmaleplug ’ PowerSupply 100-240VAC,50/60Hz,8WattsUniversalPower 100-240VAC,50/60Hz,8WattsUniversalPower S Supply,UseOnlyaHarvardApparatusApproved Supply,UseOnlyaHarvardApparatusApproved M PowerSupplyandLineCord PowerSupplyandLineCord Dimensions 22.6x17.78x15cm(9x7x6in) 22.6x17.78x15cm(9x7x6in) A Weight 2.1kg(4.6lbs) 2.1kg(4.6lbs) N AtmosphericSpecifications: U OperatingTemperature 4°Cto40°C(40°Fto104°F) 4°Cto40°C(40°Fto104°F) A L StorageTemperature -10°Cto70°C(14°Fto158°F) -10°Cto70°C(14°Fto158°F) Humidity 20%to80%RH,noncondensing 20%to80%RH,noncondensing MethodofOperation Continuous Continuous Classification ClassI ClassI PollutionDegree 1 1 InstallationCategory II II SupplierName HarvardApparatus HarvardApparatus SupplierAddress 84OctoberHillRd.,Holliston,MA01746 84OctoberHillRd.,Holliston,MA01746 SupplierPhoneNumber (508)893-8999 (508)893-8999 RegulatoryCertifications CE,ETL(UL,CSA),WEEE,EURoHS&CBScheme CE,ETL(UL,CSA),WEEE,EURoHS&CBScheme SafetyDeclarations ANSI/UL61010-1:2004ED.2Rev.2005;CAN/CSA ANSI/UL61010-1:2004ED.2Rev.2005;CAN/CSA C22.2No.61010-1:2004Ed2;IEC61010-1:2001 C22.2No.61010-1:2004Ed2;IEC61010-1:2001 Ed2Corrigendum1:2002,Corrigendum2:2003; Ed2Corrigendum1:2002,Corrigendum2:2003; CENELECEN61010-1:2001;CBScheme CENELECEN61010-1:2001;CBScheme EMCDeclaration CENELECEN61326-1:2006 CENELECEN61326-1:2006 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB web Product Overview 9 P Product Overview u m p 1 1 E l i t e & TheHarvardApparatusPump11EliteSeriesisthe Advancedmicrosteppingtechniquesareemployedto P nextgenerationofsyringepumps.Theseriesoffers furtherreducethestepangletoeliminateflow i unparalleledeaseofusethroughthehighresolution pulsation.Theaccuracyis0.5%(0.35%forPicoPlus c colortouchscreenuserinterface.Thefulltouchscreen Elite).Awidedynamicflowrangefrom1.28pl/minto o interfaceenablestheusertoquicklycreate 88.28ml/min(0.54pl/minto11.70ml/minforthePico configurationsandrecallthemforeasyuse.TheTFT PlusElite)canbeprogrammedintothepump.Flow P colordisplaypresentsallthepumpoperating ratesareselectablewithuserselectedengineering parametersonaneasytoviewrunscreen.Thetouch unitsfromml,µl,nl,pl,andhours,minutesand l screen“lock”featurepreventsaccidentalconfiguration seconds. u changesensuringtheMethodsintegrityisretained. Upto16kg(35lbs)oflinearforceisavailable.Thisforce s Agreenledlightonthefrontpanelmakesiteasytosee isuseradjustabletoensuretherightforceisappliedfor ifthepumpisrunning.Oncethepumpstartstorun,the thevarioussyringesizes. displayshowsthepumpsisrunningandtheLEDturns Thespilldamisdesignedtopreventfluidsfrom U on.Thiswillmakeiteasytoseethepump’sstatus. ingressingintothesealeddisplayorelectrical S Thepumpsareversatileandcanbeinterconnected connections. E throughtheRS-485interface.Pump11EliteSeries R modelscanbemixedandmatchedinthedaisychain ’ offeringmaximumflexibility.Upto99pumpscanbe S linkedtogetherthroughtheRS-485interface.This M interfaceiseasytouseprovidedeachpumpisassigned itsownuniquepumpaddress. A ForlimitedlaboratoryspacethePump11EliteSeries N canbeplacedonitssidetoreducethefootprintby U 55%.Thedisplaycanalsobetiltedtoallowtheuserto A operatethepumpvertically. L Notificationsanderrormessagesaredisplayedforthe usertoacknowledge,eliminatinganyguessworkabout problems. Flowperformanceisoptimizedwithasmallstepangle steppingmotorthatdrivesaprecisionleadscrewand pusherblock.Thesyringemechanismiseasytouse andsecurelyholdsthesyringesforsmoothflow performance. 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com web Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB Product Overview 10 P Easyexternalconnectionstoacomputerorother ThepumpInformation/settingsscreenshowsthe controldevicesaremadethroughUSBinterface.Simple pump’ssoftwareversion,maintenanceintervaland u ASCIIcommandsmakecommunicationwiththepump pumpaddress.Thepump’salarmconfigurability m easy.Fordirectcontrolofthepump,theusercanuse includesalarmsfornearendofrun(userselectable), theI/Ointerface(15pinDsub).Onetriggeroutputanda completionofrun,powerup,keypadclicksandstall triggerinputinforexternaleventssuchasaprocess detection. p parameterareavailable.Thefootswitchinputwillallow thecontrolofthepumpthroughanexternaldevice.The 1 unitalsohasanoutputforrunindicationallowing Pump Models 1 connectiontoaremoteLED. InfusionOnly– TheBasicandProgrammable11ElitePumpsare (singleanddualsyringemodels):Thesetwomodels E availablewithsingleanddualsyringeoptions.Complete supportinfuseonlyQuickStartMethodswith l flexibilityisofferedwiththeabilitytouseANY user-definedflowratesandselectabletargetvolumeor i manufacturerssyringesrangingfrom0.5µlto60ml targettimevaluestocontrolthetotalinfusiontime. t singlesyringeand5µlto10mldualsyringe. e Infusion/WithdrawalProgrammable– Theprogrammablemodelsoffermaximumflexibility (singleanddualsyringemodels):Thesetwomodels & andcapabilityforconfiguringandrunningdifferent supportinfuseonly,withdrawonly,infuse/withdrawand Methods.Methodscanbeconfiguredandstoredinthe withdraw/infuseQuickStartMethodswithuser-defined unit,andrecalledquicklywiththetouchofthescreen. flowratesandselectabletargetvolumeortargettime P TheMethodsareidentifiedwitha15character valuestocontrolthetotalinfusiontime.Thesemodels i alphanumericnameforeasyidentificationandcanbe alsosupporttwouser-definedMethodsupto50steps c storedonthecomputeranddownloadedatfuture each.TwoMethodscanbestored. o dates.Extensiveprogrammingoptionsallowtheuserto duplicateconfigurations,appendoneconfigurationto PicoPlusInfusion/WithdrawalProgrammable– another,renameMethods,deleteMethods,export (dualsyringeonly):SupportsallfourQuickStart P MethodstoaPCorexportaMethodtoanotherpump. Methodsandtwouser-definedMethodsupto50 l Thisfeaturecanensureconsistencyandaccuracyof stepseach. u multiplepumps. s PreprogrammedprofilesareselectablefromConstant Rate,Ramp,AutofillandGradient.Thesestandard profilesmakeconfigurationeasytosetup.Ifmore U complexityisneededtheusercanselectfromadvanced Methodprogrammingoptionsincluding: S E • Timedelays R • Repeatingsteps ’ S • Stoppingthepump M • TriggeringthepumpsTTLoutput A • Acceptinganeventinputinsuchasauser touchormotorstall N U • Eventscantriggerthepumptowithdrawor infuse A L 508.893.8999 508.429.5732 [email protected] phone fax e-mail www.harvardapparatus.com web Pump11EliteSeriesSyringePumpUser’sManual • Publication5420-002RevB

Description:
Harvard Apparatus Pump 11 Elite. & Pump 11 Pico Plus Elite Series. Publication 5420-002 Rev B w w w .h a rv a rd a p p a ra tu s .c o m. Pump 11 Elite &.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.