ebook img

Fire Alarm PDF

266 Pages·2007·12.25 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Fire Alarm

Product Catalogue 2007 Fire Alarm Content General Details 3 - 5 1 Introduction 3 Extensions 4 Generale Information 5 Control panels 7 - 54 2 Conventional Control Panels 8 - 9 IQ8Control - Intelligent addressable 10 - 25 System 8000 26 - 42 Extinguishing Systems 43 - 51 CMSI 52 - 54 Power supply / Display and Operating units 55 - 70 3 Power Supply Power Supply Units 56 - 57 Voltage Converters 58 Batteries (rechargeable) 59 - 61 Display and Operating Untits Standard 62 Serial Connection 63 Network 64 - 65 Fire brigade indicating & Operating panels 66 - 70 Network Technology 71 - 77 4 essernet 72 - 75 IGIS-LOOP 76 - 77 Management Systems 79 - 92 5 WINMAGplus 80 - 91 WINMAG Lite 92 Automatic Detectors 93 - 123 6 Detector Series 9000 (Conventional) 94 - 95 Detector Series IQ8Quad - Intelligent addressable 96 - 104 Detector for Hazardous Areas 105 - 108 Detector Base Series 9x00 109 Detector Base Series IQ8Quad 110 Accessories 111 - 121 Home Smoke Detector 122 - 123 1 Content Manual Call points 125 - 148 7 Large Design - ABS 126 - 129 Large Design - Aluminium 130 - 136 Large Design - Accessories 137 - 140 Small design - ABS 141 - 145 Special Design 146 - 148 Transponder 149 - 159 8 esserbus 150 - 159 Wireless components 161 - 168 9 Wireless modules 162 - 168 Detectors for Special Applications 169 - 208 10 Flame Detectors 170 - 171 Air Duct Detectors 172 - 177 Line Heat Detectors 178 - 179 Line Smoke Detectors 180 - 182 Aspirating Smoke Detectors 183 - 207 Accessories 208 Alarm Devices 209 - 226 11 IQ8Alarm - Intelligent addressable 210 - 216 Conventional alarm devices 217 - 223 Remote Indicators 224 - 226 Door release system 227 - 237 12 Automatic Door Systems 228 - 230 Triggering Devices 231 - 232 Door Holding Magnets 233 - 237 Installation & Service 239 - 247 13 Housings & accessory 240 - 247 Appendix 248 - 264 14 Planning guide for loop installation 248 - 249 Order Form IQ8Quad for individual composition of languages 250 - 251 Order Form WINMAG / WINMAG Lite 252 - 253 Index 254 - 259 Part Number Index 261 - 264 2 wwwwww..eesssseerr--ssyysstteemmss..ccoomm 1 Introduction Welcome to the New Fire Alarm Product Catalogue 2007 2 We are pleased to be able to provide this catalogue and introduce so many new innovative fire alarm products to you. As always we are very grateful for your interest in our wide range of products. 3 This catalogue contains information on all fire alarm products engineered and designed in Neuss, Germany - the competence centre for Fire Technology. 4 5 6 Linde AG, Kollsnes, Norway • SES Global S.A., Luxembourg • BYK Additives & Instruments, Germany 7 8 9 Bank of Baden Württembergische, Germany • Semperoper, Germany • EKO Steel GmbH, Germany 10 The part number coding system for language, branding and country variants remains the same as in the pre- 11 vious catalogue. If a part number has no suffix, the product is branded with Esser. A list of the possible suffi- xes is given below: Suffix Description 12 .DK0 Esser, Denmark .F0 Esser, France or French version .N4 Eltek 13 .VC0 Esser, China or Chinese version In the catalogue this information is supplemented with the description. The language will be included and the 14 country or brand will be given where appropriate. In these cases the functionality or marking of the product will be as described for the country or brand. Unless otherwise stated, products are branded Esser. For many variants there is no difference in functionality or technical specification except for language. To save space the first entry for each part will include the functional description and technical data. Following variants will only list features and specification if there is any essentially different data. Example: Data for 801519.F0 is listed against 801519. Enjoy your reading! 3 Extensions The list below provides a brief explanation of various extensions used in this product guide. Please note that some products don't have any extension but are for example Gent branded acc. = according to MCP = manual call point approx. = approximately MFAB = master box ARS = aspirating detector MM = micromodule CCTV = closed circuit TV NC = normally closed contact CPU = central processing unit NO = normally open contact CTC = center to center OMF = operating module front DB = database PAM = series 9200 DFD = series 9100 pcb = printed circuit board DIBT = German Institut for pcs. = pieces Technical Approvals PLC = programmable logic control DIL = dual in line PM = delay and verify functions DIN0 = German Institut for POROM = programmable read only Standardization memory DIP = dual in parallel PTB = National Institute of Natural DKC = display keyboard card and Engineering Sciences DRS = digital receiving station RAM = random access memory DU = Depth Unit RIP = remote indicating panel EDD = series 9000 ROR = rate-of-rise heat detector EDP = Esser Data Protocol SHV = smoke heat ventilation EL = Line voltage module EN = European Norm SMD = surface mounted EOL resistor= end-of-line resistor technology Ex = explosion proof SOC = switch-on control FACP = fire alarm control panel SZI = single zone indicator FBF = firepanel for Fire Brigade TAL = technical alarm module FD = fire detection TM = coincidence detection FDC = fire detection panel USB = universal serial bus FDOP = fire brigade panel UV = ultra-violet FDS = fire detection system VDE = Association for Electrical, FSA = door release system Electronic and Information HU = used for 19 inch rack e.g. "6HU" Technologies 1 HU = 44.45mm VdS = Association of German I/O = input/ output Property Insurance IC = integrated circuit Companies IDS = intruder detection system VGA = video graphics array IDT = intelligent display terminal VPP = voltage peak-peak IP = ingress protection rating IR = infrared LAN = local area network LCD = liquid cristal display LED = light emitting diode LF = low frequency LPCB = Loss Prevention Certification Board LRS = high sensitivity aspiration detector 4 wwwwww..eesssseerr--ssyysstteemmss..ccoomm Abbreviations 1 = List of contents which the part number includes = Information, important notice 2 such as special versions, dependencies etc. = Packing unit 3 Notice regarding the packing unit: 4 1. The item will only be sold in packing unit. 2. The number of items, which have to be ordered, always refers to the number of packing unit rather than the 5 number of single items. 3. The price stated in the catalogue is always the respective price for the packing unit. It is not the price for the single item. 6 Example item number 701040 (spare glass pane): 7 Packing unit: 10 items. An order of 3 items, for instance, would be equivalent to an order of 3 packing units. This would correspond to 30 items of spare glass pane, which have been ordered. 8 What happens,if the phase-out date of a product is reached? 1.We guarantee to supply you for up to five years all related components are available and the legal regulations permit this. 9 2.Manufacturing-stop date is five years after the phase-out date. No matter whether we are able to manufacture the items, we will stop manufacturing them. 10 3.After stopping delivery, as far as it is possible for us, we will try to repair the product for further two years. 4.So long as stock is available, the products can be ordered further with the same part number, as far as this is legally permissible. 11 5.As soon as the products are no longer available in our main-warehouse, we supply you with products of our service and repair warehouse. These products are marked by a "K"-Number. In this case it can be a repaired product, however as good as new. Also here we must consider the actual legal regulations. 12 Ingress Protection rating 13 Degrees of protection against solid foreign Degrees of protection against liquid foreign objects objects indicated by the first characteristic indicated by the second characteristic numeral 14 numeral Second characteristic brief numeral discription: First characteristic brief numeral description: 0 Non-protected 0 Non-protected 1 Protected against vertically falling water 1 Protected against solid foreign drops objects of 50 mm diameter and greater 2 Protected against vertically falling water 2 Protected against solid foreign drops when enclosure tilted up to 15° objects of 12,5 mm diameter and greater 3 Protected against spraying water 3 Protected against solid foreign objects of 2,5 mm diameter and greater 4 Protected against splashing water 4 Protected against solid foreign 5 Protected against water jets objects of 1,0 mm diameter and greater 6 Protected against powerful water jets 5 Dust-protected 7 Protected against the effects of temporary 6 Dust-tight immersion in water 8 Protected against the effects of continuous immersion in water 5 6 wwwwww..eesssseerr--ssyysstteemmss..ccoomm 1 2 3 4 5 6 7 8 9 10 11 Control Panels Conventional Control Panels 8 - 9 IQ8Control - Intelligent addressable 10 - 25 12 System 8000 26 - 42 Extinguishing Systems 43 - 51 13 CMSI 52 - 54 14 7 Control Panels Conventional Control Panels Fire / Intruder Alarm Panel 2001 382001 ¬G5"t− Fire / Intruder alarm panel 2001 - Esser,German Universal small control unit with two detector zones for monitoring intrusion and/or fire detectors. Up to 30 Series 9000 / 76xxxx fire detectors or up to 10 Series 9000 / 78xxxx fire detectors with switch-on-control as well as 10 Series 9100 detectors without addressing with con- ventional base 781590 can be connected per detector zone. Alternatively, motion or glass breakage detectors can be connected. An additional perma- nently armed, resistor-monitored input loop monitors manual call points and detectors for technical alarm, sabotage or hold-up. Remote arming is possible, for example, using a key- operated switch. Via a control input the panel can be acknowledged, reset or armed and dis- armed. Features Technical Data • Two disconnectable detector zones, programm- able either for fire or intruder alarm monitoring Mains voltage 230V AC • One detector zone for sabotage, hold-up or Mains frequency 50 to 60Hz technical alarm detection Operating voltage 12V DC • One control input for remote operation Rated current 0.1A • Adjustable switch-on and alarm delay time for Quiescent current approx. 40mA intrusion messages Total current max. 350mA • Adjustable alarm time Emergency power supply 12V / 2Ah • Programming via DIP switch and potentio- Relays 2 meter Contact load relay 30V DC / 1A • Integrated service and maintenance pro- Transistor outputs 4 (12V DC / 0.5A) gramme, e.g. one-man revision or switch-on Ambient temperature -5°C to +45°C control Storage temperature -5°C to +50°C Class of protection I according to DIN EN 60950 Type of protection IP 40 Housing ABS plastic Colour white, similar to RAL 9016 Colour front plate grey-blue, similar to RAL 5008 Dimensions (WxHxD) 270 x 221 x 71mm Battery capacity temperature controlled Ambient conditions class 3k5 as per IEC 721-3-3:1994 Type of protection IP 40 Weight 1.5 kg Space for 1 x 12 V DC / 1.9 Ah battery, Part No. 018002 (not included). Compatible with all 12V DC standard devices 382011 ¬G5,+− Fire / Intruder alarm panel 2001 - Esser,English As 382001 but with: Front panel: English labelling 382201 ¬G7"x− Fire / Intruder alarm panel 2001 - Esser,Dutch As 382001 but with: Front panel: Dutch labelling 382010 ¬G5+(− Fire / Intruder Alarm Panel 2001 - Esser,Russian As 382001 but with: Front panel: Russian labelling 8 wwwwww..eesssseerr--ssyysstteemmss..ccoomm Control Panels Conventional Control Panels FACP 80 1 Approval: VdS, CNMIS, CNBOP 2 Microprocessor-controlled fire alarm control panel with 4 or 8 detector zones in compliance with DIN EN 54, DIN VDE 0833, DIN 14675 and VdS 2540, for connection to automatic con- ventional detectors (76xxxx) and manual call points of Series 9000 without switch-on con- 3 trol as well as fire detectors of Series 9200. Technical Data 4 Mains voltage 230V AC Mains frequency 50 to 60Hz Features Operating voltage 24V DC Rated current 0.3A 5 • 4 or 8 detector zones with up to 30 detectors per Quiescent current typ. 16mA / max. 24.5mA detector zone Emergency power supply 2 x 12V / 7Ah • LCD display with two lines with 20 characters for Power consumption typ. 5W / max. 75W each line Ambient temperature -5 °C to +45 °C 6 • Single zone indication Storage temperature -5 °C to +50 °C • CPU failure safe operation Ambient conditions class 3k5 as per IEC 721-3-3:1994 • 1 common fire output, potential-free, max. 30V Class of protection I as per DIN EN 60950 DC / 2A Type of protection IP 40 7 • 1 alarm device output, monitored, 24V / max. Housing ABS plastic 500mA operation Colour grey, similar to Pantone 538 • 1 interface for fire man routing equipment • 1 interface for routing fault events Weight 3.1kg • 1 interface for fire protection equipment, which Dimensions (WxHxD) 355 x 375 x 115mm 8 can be programmed as “standard extinguishing interface” Space for 2 x 12V/7Ah batteries (Part No. 018004) not included. End-of-line capacitor for zone • “Transmission delay” function (PM operation to monitoring (22 μF / 35 V), fitted in last detector of the zone required. avoid deceptive alarms, delay / interrogation) 9 • “Two-alarm dependency” function (TM operation Complete control panel including system software, installation material and installation / opera- to avoid deceptive alarms being triggered), alter- ting manual and log book for fire detection systems. Batteries are not included. native programming: intermediate alarm storage for each detector zone, two-detector dependency 10 for each detector zone, two-zone dependency bet- ween detector zones 1&2, 3&4 • Connection for fire brigade operating panel, in compliance with DIN 14661 11 • 12V / 400mA voltage supply for fire brigade ope- rating panel or other use • Integrated connection for fire brigade key box • 4 zone related transistor outputs, 12V or 24V 12 (external), capacity of up to 50mA • 1 relay as changeover contact, freely programm- able (fire, pre-alarm, trouble, disconnection), Application example option between floating or 24V operation 13 • 24V / 0.5A voltage supply for external devices Accessories: • Alarm counter 804901 Conventional MCP electronic module with second microswitch • Test mode • Potential-free transmission unit output for actua- 804970 Conventional MCP, red housing with glass pane - Esser ting dial-up devices (TWG) 704470 MCP-electronic module with 24V DC and second microswitch 14 • Central output for alarm signalling devices if no 704480 MCP-electronic module with 24 V DC fire brigade key box is connected • Switch function for automatic door holder system 766239 Sounder, red (without DIBT approval) 766304 Flashing light, 24V DC, amber 766306 Flashing light, 24V DC, red 766308 Flashing light, 24V DC, green 766320 Flashing light (round design) 24V DC, red 766322 Flashing light (round design) 24V DC, amber 788705 ¬ox&`− FACP 80-4 - Esser,German,24V DC With 4 detector zones 788706 ¬ox'c− FACP 80-8 - Esser,German,24V DC With 8 detectors zones 788706.GB0 ¬ox'§/HC1$− FACP 80-8 - Esser,English,24V DC as 788706, but english version 9

Description:
Fire / Intruder alarm panel 2001 - Esser, German. 382001. Universal small control unit with .. Ambient atmosphere class 3k5 as per IEC 721-3-3:1994.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.