ebook img

Endos AC/ACP User Manual PDF

76 Pages·2007·1.4 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Endos AC/ACP User Manual

ENDOS AC / ACP 0051 (120V version) User's Manual Release 10 January 2006 (Rev. 5) USER'S MANUAL Revision history Revision history Rev. Date Page/s Modification description 0 02.04.03 - Document approval. 1 25.09.03 All Remote timer version release. ETL certification. (Ref. RDM 5641) 2 10.11.03 7, 8 Addition of "X-MIND" identification on main label. (Ref. RDM 5693) 3 26.03.04 8 Notify body change for CE mark. (Ref. RDM 5781) 4 15.03.05 8, 18, 36 Editorial correction on Enabling/Disabling the "Ready" key. Modified the DP arm label. (Ref. RDM 5938, RDM 6052) 5 10.01.06 28 Dose linearity reference measurement time update. (Ref. RDM 6164) (Rev. 5) ENDOS AC/ACP (120V) USER'S MANUAL Revision history THIS PAGE IS INTENTIONALLY LEFT BLANK ENDOS AC/ACP (120V) (Rev. 1) USER'S MANUAL Contents Contents 1. INTRODUCTION 1 1.1 Icons in the manual ............................................................................... 1 2. SAFETY ASPECTS 2 2.1 Warnings ............................................................................................... 3 2.2 Protection from X-rays ........................................................................... 4 2.3 Environmental risks and disposal .......................................................... 4 2.4 Symbols in use ...................................................................................... 5 3. CLEANING AND DISINFECTION 6 4. DESCRIPTION 7 4.1 Identification labels ................................................................................ 7 4.2 Functions, Models and Versions ............................................................. 9 4.2.1 Extension arm and scissors arm ........................................................... 9 4.2.2 Tubehead ............................................................................................. 9 4.2.3 Timer .................................................................................................. 10 4.3 Configurations ..................................................................................... 11 4.3.1 Standard configuration ....................................................................... 11 4.3.2 Remote timer configuration ................................................................ 12 4.3.3 Mobile stand configuration ................................................................. 13 4.3.4 Remote X-ray button configuration ..................................................... 14 5. TECHNICAL DATA 15 5.1 Method for correcting exposure times ................................................... 18 5.2 Method for measuring technical factors ................................................ 20 5.3 Correct use of dosimeters to measure exposure times ........................... 21 5.4 Curves tube features ............................................................................ 23 5.5 Reference standard .............................................................................. 27 5.6 Overall dimensions .............................................................................. 29 6. GENERAL USE INSTRUCTIONS 30 6.1 "ENDOS ACP" timer ............................................................................. 30 6.2 "ENDOS AC" timer ............................................................................... 34 6.3 Visual signals ...................................................................................... 36 (Rev. 1) i ENDOS AC/ACP (120V) USER'S MANUAL Contents 7. EQUIPMENT USE 37 7.1 Equipment preparation ........................................................................ 38 7.1.1 Preparation of the timer for X-ray use with automatic selection of exposure times (only for ENDOS ACP version) .................. 38 7.1.2 Preparation of the timer for radiographic use with manual selection of exposure times ................................................................. 39 7.1.3 Preparation of the timer for Digital Radiography (Videoradiography) use with automatic selection of exposure times (only ENDOS ACP version) ............................................................................................... 40 7.2 Preparation of the tubehead ................................................................. 41 7.3 Exposure techniques ............................................................................ 45 7.3.1 Bisecting technique ............................................................................ 45 7.3.2 Parallel technique ............................................................................... 47 7.4 Exposure ............................................................................................. 48 7.5 Special functions ................................................................................. 50 7.5.1 Counting the number of exposures made ........................................... 50 7.5.2 Selection of multiplication factor for different types of film .................. 51 7.5.3 Selection of multiplication factor for Video-X-Ray-Digital .................... 53 8. MESSAGES ON DISPLAY 54 8.1 Functional messages ............................................................................ 54 8.2 Error signalling .................................................................................... 57 8.2.1 Non re-settable errors ......................................................................... 58 8.2.2 Non fatal errors in start-up phase ...................................................... 59 8.2.3 Errors in exposure phase ................................................................... 60 9. CHECK AND CORRECTION OF POSSIBLE ERRORS IN DENTAL X-RAYS 61 9.1 Typical faults in intraoral X-rays .......................................................... 61 9.2 Typical faults caused by wrong positioning ........................................... 63 10. MAINTENANCE 64 This publication can only be reproduced, transmitted, transcribed or translated into any human or computer language with the written consent of Manufacturer. ENDOS AC/ACP (120V) ii (Rev. 1) USER'S MANUAL Contents This Manual in English is the original version. (Rev. 1) iii ENDOS AC/ACP (120V) USER'S MANUAL Introduction 1. INTRODUCTION NOTE: (cid:42) This manual is updated to the product status it is sold with, to guarantee the user an adequate reference for equipment use and any aspect connected with use safety. The manual may not reflect any product variation without impact on operating procedures and use safety. The intraoral radiographic ENDOS AC/ACP, produces high quality intraoral X-rays, thanks to reduced exposure times and the small dimensions of the focal spot. ENDOS AC/ACP is exclusively intended for the execution of intraoral X-rays. The equipment has the following features: • Very good quality X-rays pictures • user friendly • ergonomic design. The equipment is controlled by a microprocessor that makes it possible to reproduce exposure times and is composed of the following parts: • Timer: ENDOS AC or ENDOS ACP equipped with wall plate • Extension arm (30 cm, 60 cm or 80 cm for wall version) • Scissors arm (DP) • Tubehead 70 kV 8 mA – X-ray tube with grid. The purpose of this manual is to provide the user with instructions that will allow him to run the equipment safely and efficiently. The equipment must be used according to the procedures in the manual and never for different purposes from the ones for which it has been designed. 1.1 Icons in the manual (cid:42) Indicates a “NOTE”; we recommend particular attention in reading the subjects identified with this icon. (cid:44) Indicates a “WARNING”; subjects identified with this icon concern safety aspects regarding the patient and/or the operator. (Rev. 1) 1 ENDOS AC/ACP (120V) USER'S MANUAL Safety aspects 2. SAFETY ASPECTS (cid:44) WARNING: Read this chapter very carefully. Villa Sistemi Medicali designs and makes their equipment according to safety requirements; moreover, they supply all necessary information for appropriate use and warnings relating to dangers connected with X-ray generators. The manufacturer does not accept any responsibility for: • Use of ENDOS AC/ACP equipment for purposes other than those for which it has been designed, • damages to the equipment, the operator, the patient caused both by wrong installations and maintenance that do not follow the procedures contained in the user manuals and the installation provided with the equipment, and by wrong operating techniques, • mechanical and / or electrical changes , made during and after installation, that differ from the ones in the Service Manual. Only personnel authorised by the manufacturer may carry out technical work on the equipment. Only authorised personnel can remove the tubehead from its support and/or gain access to live parts. ENDOS AC/ACP (120V) 2 (Rev. 1)

Description:
the user an adequate reference for equipment use and any aspect connected with use safety. The manual may not reflect any product variation without impact on operating procedures and use safety. The intraoral radiographic ENDOS AC/ACP, produces high quality intraoral X-rays, thanks to reduced
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.