ebook img

DWU Standard Technical Specifications for Water & Wastewater Construction PDF

236 Pages·2014·1.27 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview DWU Standard Technical Specifications for Water & Wastewater Construction

SSTTAANNDDAARRDD TTEECCHHNNIICCAALL SSPPEECCIIFFIICCAATTIIOONNSS FFOORR WWAATTEERR && WWAASSTTEEWWAATTEERR CCOONNSSTTRRUUCCTTIIOONN AAuugguusstt,, 22001144 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 Document Number: DWU-PRO-022-ENG Revision Number: 1 Approved By: Chad Kopecki Effective Date: 9/1/2014 Description of Last Initial Release Change: Document Title: Standard Technical Specifications for Water & Wastewater Constructions TABLE OF CONTENTS PREFACE P.1 Acknowledgements ...............................................................................................P - 1 P.2 Background ...........................................................................................................P - 1 DIVISION 1: GENERAL ITEMS 1.1 Sample Bid .............................................................................................................1.1 - 1 1.2 Submittals ............................................................................................................1.2 - 1 1.3 Approved Equal ....................................................................................................1.3 - 1 1.4 Project Partnering ................................................................................................1.4 - 1 1.5 Pre and Post Construction Video of Project Site ...............................................1.5 - 1 DIVISION 2: WATER PIPELINES 2.1 Fusible Polyvinyl Chloride (PVC) Water/Wastewater Pipe .............................2.1 - 1 2.2 Restrained Joint Polyvinyl Chloride (PVC) Water Pipe ...................................2.2 - 1 2.3 Steel Water Pipe ....................................................................................................2.3 - 1 2.4 Rehabilitation ofExistingWater Main by Cured-In-PlacePipe(CIPP) ...........2.4 - 1 2.5 Rehabilitation ofExistingWaterMain by Pipe Bursting(PB) ...........................2.5 - 1 2.6 Sliplining of Water Main ......................................................................................2.6 - 1 2.7 Temporary Water Main .......................................................................................2.7 - 1 TABLE OF CONTENTS TOC - 1 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 DIVISION 3: WASTEWATER PIPELINES 3.1 Rehabilitation ofExistingWastewaterMain by Cured-In-PlacePipe(CIPP) ..3.1 - 1 3.2 Rehabilitation of Existing Wastewater Main by Pipe Bursting (PB) ...............3.2 - 1 3.3 Recycle/Reclaimed of Water Pipe........................................................................3.3 – 1 3.4 Sliplining of Wastewater Main ............................................................................3.4 - 1 DIVISION 4: WATER APPURTENANCES AND PROCEDURES 4.1 Removal, Handling, Cutting, Disturbance and Disposal of Asbestos Cement Pipe ...........................................................................................................4.1 - 1 4.2 Horizontal Directional Drilling (HDD) of Water Mains ...................................4.2 - 1 4.3 Electrical Continuity Testing of Water Mains ...................................................4.3 – 1 4.4 Water Meter Vault Protective Lining .................................................................4.4 – 1 DIVISION 5: WASTEWATER APPURTENANCES AND PROCEDURES 5.1 Wastewater Flow Control and Bypass Pumping ...............................................5.1 - 1 5.2 Wastewater Main and Manhole Cleaning ..........................................................5.2 - 1 5.3 Television Inspection of Wastewater Mains .......................................................5.3 - 1 5.4 Manhole Frame Seal .............................................................................................5.4 - 1 5.5 Manhole Protective Lining ...................................................................................5.5 - 1 5.6 Precast Concrete Additive for Wastewater Manhole ........................................5.6 - 1 DIVISION 6: PAVEMENT RESTORATION AND OTHER MISCELLANEOUS ITEMS 6.1 Cement Stabilized Sand Backfill .........................................................................6.1 - 1 6.2 Temporary Paving (Hot or High Performance Mix ..........................................6.2 - 1 6.3 Heavy Vehicular Paving Brick ............................................................................6.3 - 1 6.4 Tree Planting .........................................................................................................6.4 - 1 TABLE OF CONTENTS TOC - 2 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 DIVISION 7: LISTS OF APPROVED MATERIALS 7.1 Approved Materials for Water Distribution System by Trade Name .............7.1-1 7.2 Approved Materials for Wastewater Collection System by Trade Name .......7.2-1 TABLE OF CONTENTS TOC – 3 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 PREFACE P.1 ACKNOWLEDGMENTS: This manual replaces first edition of Standard Technical Specifications for Water & Wastewater Construction Manual by Dallas Water Utilities (DWU) dated August, 2011. The chronological list of events in developing the DWU manual is summarized as follows: AUG, 2011: Compilation of various standard specifications into first edition of the manual. AUG, 2014: Revision of 2011 manual to include additional specifications on various water and wastewater trenchless technologies and rehabilitation methods. P.2 BACKGROUND: The intent of this manual is to provide standard technical specifications for various commonly used items which may not be covered in details under the latest editions of Public Works Construction Standards by North Central Texas Council of Governments (NCTCOG), City of Dallas Addendum to NCTCOG and Standard Drawings for Water & Wastewater Construction by Dallas Water Utilities (DWU). This technical resource is not intended to substitute for any professional engineering judgment by the designer. Any appropriate modifications shall be incorporated into the contract document upon approval by Owner. Unless otherwise specified in the contract document, this manual shall be used by the Contractor in the construction of water and wastewater mains owned and operated by DWU. In case of conflict between contract documents, priority of interpretation shall be in the following order: • Project Plans & Specifications • DWU Standard Technical Specifications for Water and Wastewater Construction, Latest Edition • DWU Standard Drawings for Water & Wastewater Construction, Latest Edition • City of Dallas Addendum to NCTCOG, Latest Edition • Public Works Construction Standards by NCTCOG, Latest Edition In addition, lists of approved materials for water distribution and wastewater collection systems are included in this document. Unless otherwise specified in the project plans and/or specifications, these materials can be considered by the Contractor contingent upon approval by the Owner. PREFACE P - 1 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 This manual is written by Engineering Services, Dallas Water Utilities. Any questions or suggestions regarding this manual should be forwarded to Engineering Services, Dallas Water Utilities. This manual is available on the internet at: http://www.dallascityhall.org/dwu/dwu_design_standards.html PREFACE P - 2 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 SECTION 1.1 SAMPLE BID ITEM QUAN- DESRIPTION UNIT TOTAL UNIT NO. TITY AND PRICE IN WORDS PRICE AMOUNT 3550 2 EA Removal of Internal Obstruction in 1,000.00 2,000.00 Existing 6” Wastewater ain, complete in place, the sum of One Thousand DOLLARS and No SSS CENTS per each AAA 3551 2 EA Removal of Internal Obstruction in 1,500.00 3,000.00 Existing 8” Wastewater main, complete in place, the sum of MMM Fifteen Hundred DOLLARS PPP and No CENTS per each LLL 3560 4 EA Furnish and place Connection to 1,500.10 6,000.40 Existing Manhole, complete in EEE place, the sum of One Thousand Five Hundred DOLLARS and Ten CENTS per each THIS PAGE TO BE USED AS AN EXAMPLE FOR COMPLETING PROPOSAL PAGES NOTE: The Contractor’s Unit Price In Words, Unit Price In Numbers And Total Amount Must Be Shown For Each Bid Item SAMPLE BID 1.1 - 1 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 SECTION 1.2 TECHNICAL SPECIFICATION FOR SUBMITTALS PART 1: GENERAL 1.1 Data Required The Contractor shall furnish engineering data covering all materials and equipment in the contract. The data should be prepared and transmitted promptly following execution of the general contract. Delays due to failure to provide timely submittal will not result in a time extension. 1.2 Type of Data As applicable, the following types of data will be required: • Fabrication, Erection/ Placement Details: - Laying plans for large diameter pipelines - Drawings, lists and schedules for special structures • Outline, Dimension, Assembly and Installation Drawings - Terminal connection diagrams for all electrical power and lighting, and for all types of instrumentation and control circuits. • Catalog Sheets with clearly indicating items to be used • Specification Sheets • Written Statements or Certifications • Laboratory, Shop or Mill Test Reports • Basis of Design and Design Calculations • Experience and Facilities Brochures. • Samples • Parts Lists • Instruction and Maintenance Manuals SUBMITTALS 1.2 - 1 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 1.3 Information to be Included: All data needed to determine the following facts shall be submitted: 1.3.1 Conformance to specifications, including: kind, type, size, arrangement, finishes, and operation of component materials, and devices. 1.3.2 Conformance to plans, including: dimensions, orientation, appearance, external connections and anchorages, installation clearances. 1.3.3 Specific purpose or design conditions and adequacy to meet same: weights, dynamic, loads, supports required, operating characteristics. 1.3.4 Coordination with other work, including: items needed by this trade, but furnished by others, and information needed by others to perform their part. 1.3.5 Exceptions to or deviations from specified requirements if any, and reasons for same. 1.3.6 Delivery Date: • This should be stated as a firm date of delivery, not measured from approval of drawings to date of shipping. For this purpose the time taken by the Owner to process data may be taken as not exceeding ten (10) working days. However, the Owner does not assume responsibility for correctness or completeness of the data. • The Contractor should determine that proposed delivery dates will not cause delay or result in failure to complete the project on time. • No extension of time or waiver of liquidated damages will be granted due to failure to deliver on time unless the Contractor presents written evidence approved by the Owner that favorable delivery is not obtainable for an acceptable item. • Such evidence will be considered as a basis for extension of time only when presented promptly after award of contract and approved by the Owner. SUBMITTALS 1.2 - 2 DWU STANDARD TECHNICAL SPECIFICATIONS AUGUST, 2014 PART 2: SUBMITTAL APPROVAL PROCESS 2.1 Routing of Submittal Approval data and routine correspondence should be routed as follows: • Contractor to Owner (5 copies) - DWU Project Manager to Designer - DWU Project Manager to Operation Divisions (Distribution and Wastewater Collection Divisions) • Owner to Contractor (2 copies) - DWU Project Manager to Contractor 2.2 Address for Communications DWU Project Manager Dallas Water Utilities 2121 Main Street, Suite 300 Dallas, Texas 75201 2.3 Checking and Review of Data Approval • The Contractor should check all data for correctness and completeness. He will note any exceptions or discrepancies to be approved or verified by the Owner. • The Owner will review the data for general conformity to the plans and specifications. He will comment on items called to his attention for approval or verification. Approvals will be based on this review and do not constitute a blanket approval of substance, fit or function. • The Owner Engineer may at his discretion check dimensions, samples and details as a service as needed. Any discrepancies found thus will be noted for verification by the Contractor. SUBMITTALS 1.2 - 3

Description:
DIVISION 5: WASTEWATER APPURTENANCES AND PROCEDURES. 5.1. Wastewater Flow the manual. AUG, 2014: Revision of 2011 manual to include additional specifications on various water and wastewater trenchless technologies and rehabilitation Basis of Design and Design Calculations.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.