ebook img

DTIC ADA454350: Heat Transfer ad Thermal Management in a Pulsed Detonation Engine PDF

7 Pages·0.17 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview DTIC ADA454350: Heat Transfer ad Thermal Management in a Pulsed Detonation Engine

AIAA 2003-0852 HEAT TRANSFER AND THERMAL MANAGEMENT IN A PULSED DETONATION ENGINE * * John Hoke Royce Bradley , and Frederick Schauer Air Force Research Laboratory, Propulsion Directorate Wright-Patterson AFB, OH 45433 * Innovative Scientific Solutions, Inc. Dayton, OH 45440 th 41 AIAA Aerospace Sciences Meeting & Exhibit 6-9 January 2003 Reno, NV For permission to copy or to republish, contact the copyright owner named on the first page. For AIAA-held copyright, write to AIAA Permissions Department, 1801 Alexander Bell Drive, Suite 500, Reston, VA, 20191-4344. Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 3. DATES COVERED 2003 2. REPORT TYPE 00-00-2003 to 00-00-2003 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Heat Transfer ad Thermal Management in a Pulsed Detonation Engine 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION Air Force Research Laboratory,Propulsion Directorate,Wright Patterson REPORT NUMBER AFB,OH,45433 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution unlimited 13. SUPPLEMENTARY NOTES The original document contains color images. 14. ABSTRACT see report 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF 18. NUMBER 19a. NAME OF ABSTRACT OF PAGES RESPONSIBLE PERSON a. REPORT b. ABSTRACT c. THIS PAGE 6 unclassified unclassified unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 AIAA 2003-6486 HEAT TRANSFER AND THERMAL MANAGEMENT IN A PULSED DETONATION ENGINE John Hoke and Royce Bradley Innovative Scientific Solutions Inc 2766 Indian Ripple Rd Dayton, OH 45440 Frederick Schauer Air Force Research Labs Wright-Patterson Air Force Base Dayton, OH 45433 Abstract The unsteady nature of the Pulsed Detonation Engine (PDE) cycle creates a thermal environment fundamentally different from steady flow cycles. Gas velocities in a detonation tube range from O(-1) to O(1000) within a single cycle. This broad range of velocities and flow reversal make it difficult to determine analytically the contribution to the heat load from the purging, filling, detonating, and blow down portions of the cycle. In this paper, the overall heat load on a detonation tube is measured calorimetrically in an aluminum water-cooled detonation tube. The effects of operating parameters such as fill fraction, purge fraction, ignition delay, equivalence ratio, and cycle frequency are examined. Equivalence ratio and cycle frequency are found to have the largest effect on detonator tube heat load. Introduction Research Lab’s Pulsed Detonation Research Facility. This facility was described in detail by Questions have arisen as to the thermal Schauer et al.(2001), and only the details load of a pulsed detonation engine (PDE). pertinent to this study are given here. The Lower heat loads than experienced in experiments were conducted with a spark-ignited conventional turbines are expected since the hydrogen-air PDE. The cycle of the research detonating portion of the cycle is relatively short; Pulsed Detonation Engine (PDE) was divided however, the temperatures and velocities of the into three temporally equal portions: i) flow during this period are higher than in detonation window, a third of the cycle is conventional devices and potentially lead to allotted for detonation initiation and blow-down. higher heat loads. In this paper, heat-loads on Depending on the cycle frequency, a portion of the detonator tube of a PDE under several the time in this window was unused. ii) purge different operation conditions are experimentally process, a third of the cycle was used to pump air measured and presented. Previously, Eidelman et into the detonation tube to separate the exhaust al. (2001) have performed numerical simulations products from the pre-mixed fuel-air charge and to determine the transient temperature profile, to cool the internal geometry. iii) fill process, the rise time and steady state temperature along during the last third of the cycle, a pre-mixed the detonation tube. Ajmani and Breisacher charge of fuel and air was pumped into the (2002) have modeled the heat flux to a detonator detonation tube. tube and present several measurements using The fuel and airflow into the detonation heat flux gauges. Here, the overall heat load on tube were measured using a choked nozzle and the detonator tube is measured calorimetrically, choked orifices respectively. The flow rates while tube wall temperatures are measured in were actively controlled by measuring the flow separate experiments using thermocouples spot- rate and adjusting the pressure upstream of the welded to the detonator tube. measuring devise to achieve the desired flow rate. The desired flow rates were calculated Experimental Apparatus and Procedure from the detonation tube volume, operating frequency and atmospheric pressure. With the Experiments were performed on a 36” flow control system, the equivalence ratio (f), tube fill fraction (FF), and purge fraction (PF) (0.91m) detonation tube at the Air Force 1 could be adjusted with the engine running. The frequency increases the number of detonations FF and PF are defined as the fraction of the 25 detonation tube volume filled during the filling and purging process respectively. y = 21.428x R= 0.99786 A water-cooled detonation tube was 20 constructed by inserting the 2"schedule 40 W] aluminum detonation tube into a 2.5" schedule k 40 aluminum tube of similar length. The tubes d [15 a were oriented to be concentric and the space o L between the tubes at either end was welded at 10 closed. Water entered the cavity between the He 20 Hz two concentric aluminum tubes at the head end FF=1.0 5 of the detonation tube and exited at the tail of the PF=0.5 detonation tube. Type T thermocouples inserted Ign Delay~5 ms in the water flow were used to measure the inlet 0 and exit temperatures of the cooling water. The 0 0.2 0.4 0.6 0.8 1 1.2 water flow rate was measured by a rotometer. Equavalence Ratio The heat load on the detonation tube could then be calculated. The absolute error in the heat load Figure 1 Heat load verses equivalence ratio, 36" calculated was approximately 15% due to (.91m) detonation tube measurement error, conduction losses and convection losses from the outer water jacket. 35 The relative error between experiments was much less being dominated by the measurement 30 errors and was less than 7%. Thermocouples were also used on un- W] 25 cooled detonation tubes to determine thermal rise d [k 20 time and equilibrium temperatures. The a o thermocouples were spot-welded at intervals L along the detonation tube. Accuracy of the high at 15 temperature thermocouple measurements was He 10 FF=1.0 PF=0.5 estimated to be ± 50 °F. Ign Delay~5 ms 5 f=1.0 Experimental Results and Analysis 0 0 10 20 30 40 50 The effect of frequency, fill fraction, ignition Frequency [Hz] delay, equivalence ration and purge fraction on the overall heat load was investigated. The equivalence ratio was found to have the largest Figure 2. Heat load verses frequency, 36" impact on detonator tube heat load, see Fig. 1. (.91m) detonation tube The heat load at 20 Hz increased almost linearly from 0 to 21.8 kW as the equivalence ratio was increased from 0 to 1. Below an equivalence increased but the time for each portion of the ratio of 0.5 it became increasingly difficult to cycle was fixed, and the time that the exhaust achieve a detonation in the 36" (.91 m) products (after blow-down) remained in the detonation tube using a deflagration to detonator tube decreased with increasing detonation transition and the heat load measured frequency. Additionally, the average velocity of was lower than that predicted using the the fill and purge increased with increasing measurements recorded at higher equivalence frequency. For fully developed flow in a smooth ratios. Experiments were not conducted above pipe, the heat transfer coefficient increases by an equivalence ratio of one. velocity to the 0.8 power according to the Dittus- The influence that frequency has on Bolter correlation (White 1988). Therefore, at heat load is shown in Fig. 2. Note that unlike the higher frequencies, the purge and fill process thrust, doubling the frequency from 20 to 40 Hz would be more effective at removing heat from does not double the detonator tube heat load but the detonation tube. Because of the developing only increased the heat load by 58%. As the boundary layer, the heat transfer coefficient was 2 expected to be significantly higher than that predicted by Dittus-Bolter. The heat flux during 34 the fill and purge process was not measured in 35 Hz 32 these experiments. Decreasing the fill fraction of the detonation tube decreases the heat load; W] 30 k however, since the exhaust products must exit d [ 28 FF=1.0 through the unfilled portion of the detonation oa f=1.0 tube, the decrease in heat load was not as at L 26 Ign Delay 5 ms pronounced as that found for equivalence ratio. e H 24 If Fig. 3, the heat load on the detonation tube is shown to decrease by only 19% between a fill 20 Hz 22 fraction of 1 and 0.5. At a fill fraction of 0.5, the PDE was consuming half of the fuel that it 20 would be consuming at a fill fraction of 1, and 0.2 0.4 0.6 0.8 1 1.2 1.4 14% less fuel than it would consume at an Purge Fraction equivalence ratio of 0.5 and a fill faction of 1. Even though the PDE was using 14% less fuel at Figure 4. Heat load verses purge fraction, 36" a fill fraction of 0.5 than it was at an equivalence (.91m) detonation tube ratio of 0.5 and a full fill fraction, the fuel distribution in the detonation tube created a 62% difference in heat load. The lower fuel 23 10 consumption condition of FF=0.5, f =1 had the higher heat load. The majority of this difference 22 was attributed to the theoretically lower exhaust 8 21 temperatures of the 0.5 equivalence ratio W] cond2i5tion. eat Load [k 112890 Heat Load Thrust 46 Thrust [lbf] H 20 Hz 20 17 FF=1.0 2 W] 16 PF=0.5 k f=1.0 d [15 15 0 a o 0 2 4 6 8 10 12 14 L at 10 Ignition Delay [ms] He 20 Hz PF=0.5 Figure 5. Heat load verses ignition delay, 36" 5 Ign Delay~5 ms (.91m) detonation tube f=1.0 0 Lastly, the tube heat load was measured 0 0.2 0.4 0.6 0.8 1 1.2 as a function of ignition delay. This parameter Fill Fraction affects the time that the exhaust products remain in the detonation tube as well as the initial Figure 3. Heat load verses fill fraction, 36" pressure at which the mixture was detonated, see (.91m) detonation tube Hoke et al. (2002). The heat load on the detonation tube varied approximately 1.5 kW The purge fraction had a limited affect with ignition delay, see Fig. 5. The maximum on tube heat load and in Fig. 4, the effect of thrust occurred at an ignition delay of purge faction on tube heat load is shown for two approximately 5 ms and the maximum heat load frequencies, 20 and 35 Hz. At 20 Hz, increasing occurred earlier, between 2 and 4 ms. There are only small differences in the combustion the purge air from .25 to 1.25reduced the tube heat load by a kilo-watt. At 35 Hz, this effect temperatures with initial pressure, however, there was almost doubled and attributed to the higher can be a significant difference in thrust pressure. purge velocities and greater purge mass flow The higher thrust pressure leads to higher heat required for the higher frequency. transfer however, the longer residence time of 3 the early ignition will also contribute to higher load to the significant parameters. From this heat loads. Therefore, the peak of heat load study, it is evident that PDE’s should be run at occurs before the peak in thrust. lower frequencies for lower heat loads; however, The heat load on an un-cooled the heat load per unit thrust is lower at higher detonation tube should be lower than that frequencies. Additionally, throttling of the PDE measured for the cooled detonation tube because resulted in lower tube heat loads if the throttling the temperature difference between the exhaust is done by lowering the equivalence ratio rather gases and tube walls will be smaller. Shown in than decreasing the fill fraction. The ignition Fig.6 are outside wall temperatures along the delay or cycle of the PDE should be designed to length of a 72" detonation tube that was run to minimize the length of time the exhaust products thermal equilibrium. The temperature along the remain in the detonation tube after blow-down. detonation tube varied over 300 °F and thermal Additionally, there are aspiration issues that equilibrium was reached in approximately 2 encourage minimization of the time the exhaust gasses stay in the detonation tube after blow- 1500 FF= 1.0, 0.5, 0.25, 0.35, 1.0 down. Experiments with longer and larger Av gas diameter detonation tubes are planned as well as 20 Hz a numerical model. PF=0.5 IG = 10 F] g 1000 f appox 1.0 Acknowledgements e d e [ Gratitude is expressed to the technicians ur Head Tube at 21" who worked on this project: Curtis Rice, Walt er 35" mp 500 49.5" Balster and Dwight Fox (ISSI). The authors Te 66.5" would also like to thank Jeff Stutrud (AFRL/PRTS) for his computer programs used to collect and analyze the data. The technical 0 5000 5500 6000 6500 7000 7500 leadership of Dr. Mel Roquemore and Dr. Robert Hancock (AFRL/PRTS) continues to be Run Time (sec) invaluable. Funding was provided by the Figure 6. Detonation tube temperatures verses propulsion directorate and Dr. Julian Tishkoff at run time for several fill fractions, 72" AFOSR. (1.83m) detonation tube minutes. The hottest region on the detonation References tube occured in the region where transition from deflagration to detonation occurred. In this Ajmani, K. and K. J. Breisacher (2002). transition region, an overdriven detonation, with Qualitative Study of Cooling Methods higher wave velocities, and pressures, increased for a Pulse-Detonation Engine. 51st the heat transfer to the tube wall. The fill JANNAF Propulsion Meeting, Lake fraction of the detonation was varied during this Buena Vista, Florida, Chemical experiment and the heat load for a 72" detonation Propulsion Information Agency. tube appeared to be higher at a fill fraction of 0.5 than at a fill fraction of 1. This was contrary to Eidelman, S., D. Sharov and D. Book (2001). the results found for the shorter 36" detonation The Thermal Balance of PDE. tube. At lower fill fractions, the peak Computational Methods and temperatures decreased and a detonation wave Experimental Measures: 711-720. was not produces since transition from deflagration to detonation occurred around 48" Hoke, J. L., R. P. Bradley and F. R. Schauer from the closed end of the detonation tube. (2002). The Effect of the Dynamic Filling Process on PDE Perfomance and Summary and Conclusions Nozzle Selection. 51st JANNAF Propulsion Meeting, Lake Buena Vista, Although cooled-wall heat load Florida, Chemical Propulsion measurements will not produce identical results Information Agency. to hot wall tests, the results found in this study give some indication as to the sensitivity of heat 4 Schauer, F., J. Stutrud and R. Bradley (2001). Detonation Initiation Studies and White, F. M. (1988). Heat and Mass Transfer. Performance results for PDE New York, Addison-Wesley Publishing Applications. 39th AIAA Aerospace Co. Sciences Meeting and Exhibit, Reno, AIAA. 5

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.