ebook img

Digital Differential Protection PDF

314 Pages·4.133 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Digital Differential Protection

Digital Differential Protection G. Ziegler Differential Protection Symposium Belo Horizonte, 7 to 9 Nov. 2005 No.: 1 Differential Protection: Discussion Subjects (cid:216) Mode of operation (cid:216) Measuring technique (cid:216) Current transformers (cid:216) Communications (cid:216) Generator and motor differential protection (cid:216) Transformer differential protection (cid:216) Line differential protection (cid:216) Busbardifferential protection Differential Protection Symposium Belo Horizonte, 7 to 9 Nov. 2005 No.: 2 Digital Differential Protection Principles and Application Gerhard Ziegler Differential Protection Symposium BeloHorizonteNovember 2005 G. Ziegler, 10/2005 page1 Contents Pages Mode of operation3 -27 Measuring technique28 -45 Current transformers 46 -86 Communications87 -115 Generator and motor differential protection116 -122 Transformer differential protection123 -178 Line differential protection179 -216 Busbardifferential protection217 -247 7UT6 product features248 -264 Differential Protection Symposium BeloHorizonteNovember 2005 G. Ziegler, 10/2005 page2 Digital Differential Protection Mode of operation Gerhard Ziegler Differential Protection Symposium Belo HorizonteNovember 2005 G. Ziegler, 10/2005 page 3 Comparison protection -Principles Absolute selectivity by using communications I I A B •Directional comparison A B Exchange of YES / NO signals protection range (fault forward / reverse) reverse forward forward reverse • Current comparison | DI | Relay communication Relay Sampled values Phasors I t A I Binary decisions B •comparison of momentary values or phasors D B •| I | = | I - I | > limiting value A B A Differential Protection Symposium Belo HorizonteNovember 2005 G. Ziegler, 10/2005 page 4 Protection Criterion “current difference“ (differential protection) n Kirchhoff‘s law: II + I + I + ... I I= I = 0; 1 2 3 n diff Current difference indicates fault n Security by through-current dependent restraint |I1|+|I2|+ ... |In| = I Res protection n Characteristic: object I diff Trip I res n Absolute zone selectivity (limits: CT locations) No “back-up“for external faults n Differential protection: for generators, motors, transformers, lines and busbars Differential Protection Symposium Belo HorizonteNovember 2005 G. Ziegler, 10/2005 page 5 Current differential protection: Basic principle I I I I 1 2 1 2 Protection Protection object object i i 1 i 1 i 2 2 i D I> DI=I + I 1 D I> DI=I + I 1 2 1 2 =0 i 2 external fault or load internal fault Differential Protection Symposium Belo HorizonteNovember 2005 G. Ziegler, 10/2005 page 6 Generator and transformer differential protection Y d 5 L1 L1 L2 L2 L3 L3 DI DI DI Matching DI DI DI transformer Differential Protection Symposium Belo HorizonteNovember 2005 G. Ziegler, 10/2005 page 8

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.