CONSTRUCTION OF ADMIN SECTION, UET LAHORE DISTRICT LAHORE ENGINEER'S COST ESTIMATE CIVIL WORKS 1st BI-ANNUAL-2018 (1st January-2018 to 30th June-2018) DISTRICT LAHORE Sr. Item No. Description of Item Unit Qty Rate Amount No. 1 C-3/21(b) Excavation in foundation of building, bridges and other structures, including dagbelling, dressing, refilling around structure with excavated earth, watering and rammiing lead 'upto one chain (30 m) and lift upto 5 ft. (1.5 m) in ordinary soil. %0Cft 40677.8 6614.80 2 C-26/42 Spraying anti-termite liquid mixed with water in the ratio of 1:40. %Sft 20879.8 227.45 3 C-6/5(i) Cement concrete plain including placing,compacting, finishing andcuringcomplete(includingscreeningandwashingofstone aggregate):Ratio 1:4:8 %Cft 3075.0 17625.80 4 C-6/6 a-ii Reinforced cement concrete in slab of rafts / strip foundation, (3) baseslabofcolumnandretainingwalls;etcandotherstructural membersotherthanthosementionedabovenotrequiringform work (i.e. horizental in shuttering) complete in all respects:- Type C (nominal mix 1: 2: 4) P.Cft 9206.3 259.50 5 C-6/6 a-i Reinforced cement concrete in roof slab, beams, columns (3) lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, completeinallrespects:-TypeC(nominalmix1:2:4),Ground floor P.Cft 4097.7 356.30 6 C-6/6 a-i Reinforced cement concrete in roof slab, beams, columns (3)+d lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects:- Type C (nominal mix 1: 2: 4), add extra for First Floor. P.Cft 4396.0 379.80 7 C-6/6 a-i Reinforced cement concrete in roof slab, beams, columns (3)+d lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects:- Type C (nominal mix 1: 2: 4), add extra for 2nd Floor. P.Cft 4595.2 403.30 8 C-6/6 a-i Reinforced cement concrete in roof slab, beams, columns (2) lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, completeinallrespects:-TypeB(nominalmix1:1.5:3),Under Plinth Level P.Cft 316.7 383.85 9 C-6/6 a-i Reinforced cement concrete in roof slab, beams, columns (2) lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects:- Type B (nominal mix 1: 1.5: 3), Ground Floor P.Cft 675.7 383.85 10 C-6/6 a-i Reinforced cement concrete in roof slab, beams, columns (2)+d lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects:- Type B (nominal mix 1: 1.5: 3), add extra for First Floor. P.Cft 675.7 407.35 11 C-6/6 a-i Reinforced cement concrete in roof slab, beams, columns (2)+d lintels, girders and other structural members laid in situ or precast laid in position, or prestressed members cast in situ, complete in all respects:- Type B (nominal mix 1: 1.5: 3), add extra for 2nd Floor. P.Cft 651.0 430.85 12 C-6/9(c) Fabrication of mild steel reinforcement for cement concrete, including cutting, bending, laying in position, making joints and fastenings,includingcostofbindingwireandlabourchargesfor binding of steel reinforcement (also includes removal of rust from bars):- Deformed bars (Grade-60) %Kg 82066.4 11632.20 13 C-7/4(i) Pacca brick work in foundation and plinth in Cement,sand mortar. Ratio 1:6 %Cft 2174.7 19786.45 14 C-3/15(i) Filling,watering,rammingearthunderfloors(withsurplusearth foundation). %0Cft 13559.3 3170.65 15 C-3/15(ii)+ Filling,wateringandrammingearthunderfloorswithnewearth C-3/17 excavated from outside,lead upto 1km ). (a+b) %0Cft 20954.8 9385.15 16 C-7/5(i) Pacca brick work in ground floor cement, sand mortar Ratio 1:5 %Cft 3051.5 21442.05 17 C-7/5(i) Pacca brick work in ground floor cement, sand mortar Ratio 1:4 %Cft 453 21920.85 18 C-7/5(i)+ Pacca brick work in first floor cement, sand mortar Ratio 1:5 7/6(i) %Cft 2203.7 22246.45 19 C-7/5(i)+ Pacca brick work in first floor cement, sand mortar Ratio 1:4 7/6(i) %Cft 709.8 22725.25 20 C-7/5(i)+ Pacca brick work in second floor cement, sand mortar Ratio 1:5 7/6(ii) %Cft 2220.5 23229.05 21 C-7/5(i)+ Pacca brick work in second floor cement, sand mortar Ratio 1:4 7/6(ii) %Cft 739.9 23707.85 22 C-11/11(b) Cement plaster 1:5 upto 20' (6.00 m) height:- b) ½" (13 mm) thick %Sft 28391.5 1757.15 23 C-11/9(b) Cement plaster 1:4 upto 20' (6.00 m) height:- b) ½" (13 mm) thick %Sft 12120.3 1831.25 24 C-11/23(a- Distempering:- New surface:- three coats iii) %Sft 28391.5 395.40 25 C-13/32A Providingandapplyingweathershieldpaintofapprovedquality (a-i,ii) onexternalsurfaceofbuildingincludingpreparationofsurface, applicationofprimercompleteinallrespect:a)newsurface:ii) Two coat. %Sft 2876.79 2200.50 26 C-7/30 Supplying and filling sand under floor; or plugging in wells. %Cft 2881.0 1922.00 27 C-6/2 Dryrammedbrickorstoneballast,1½"to2"(40mmto50mm) gauge. %Cft 3191.0 4262.30 28 C-6/5(f) Cement concrete plain including placing,compacting, finishing andcuringcomplete(includingscreeningandwashingofstone aggregate):(f) Ratio 1: 2: 4 %Cft 1457.9 22101.80 29 C-10/15(e) Providingandlayingtoppingofcementconcrete1:2:4,including surface finishing and dividing in panels:-(e) 2"(50 mm) thick %Sft 1220.7 4848.45 30 C-9/5 Single layer of tiles 9"x4½"x1½" (225x113x40 mm) laid over 4"(100mm)earthand1"(25mm)mudplasterwithoutBhoosa, groutedwithcementsand1:3ontopofRCCroofslab,provided with 34 lbs. per %Sft. or 1.72 Kg/Sq.m bitumen coating sand blinded. %Sft 6176.3 6398.65 31 C-26/37(ii) Supplying and laying polythene sheet over D.P.C. under floors and on roofs, etc.ii)500 gauge (.005" thick) P.Sft 6716.8 4.00 32 C-9/45-b ProvidingandLayingInsulationmaterialofExtrudedPolystyrene XPS in Rigid Insulation/Foam Boardon rooforwalls,Density 32- 38Kg/M, compressive strength250-400kpa,R-value5 per inch thickness and water obsorbtion (1%byvolume,cel lstructure clored cell) i/c cutting and placing in position complete in all respect.(b)1-1/2" thick %Sft 6176.3 8093.90 33 C-25/53(b) Providing and fixing all types of glazed aluminum windows of anodized champagne color partly fixed and party sliding using deluxesectionofapprovedmanufacturer havingFrame ofsize 100mmx30mm using frame at bottom, attopand side leaf leaf frame sections of 60mmx23mm at top & bottom and size 45mmx25mmatcenterandsize45mmx25mmatsides,Jalileaf frame size 43mmx13mm i/c fine quality aluminum jali, 5mm thick imported tinted glass with rubber gasket using approved standardlatches,wheel,stopper,brushchannelanglejointand hardware etc.in all respect .b)2 mm thick P.Sft 2518.0 761.80 34 C-12/50 Providing and fixing 1½" (40mm) thick solid flush door shutter (Approved Factory Manufactured) with commercial ply (5 mm thick) on both sides double pressed and deodar wood lipping 1½"x3/8" (40mm x 10mm) around shutter including chromium platedfitting,ironhingeswithaluminiumkickplate22SWGon both sides & finger plate complete in all respect. P.Sft 216.30 365.25 35 C-12/15 a ProvidingandfixingM.S.sheethollowpressedframeofdoors, windows, C. windows, etc. (chowkat only) of 20SWG welded with M.S. flat 6"x 1¼" x 1/8" (150mmx30mmx3mm) M.S. holdfast 9"x1"x1/8"(225mmx25mmx3mm) welded/screwed 4" (100mm)longironhinges,includingfillingchowkatwithcement sand mortar 1:8 and embedding holdfast in cement concrete 1:2:4, complete in all respects:a) single rebate P.Sft 576.8 139.95 36 C-9/20 a Castironrainwaterdownpipefixedinposition,excludingheads and shoes, but including painting and clamps, etc:a) 4" dia (100 mm) cast iron down pipe. Rft 104.0 218.30 37 C-9/21 Rain water down pipe cast iron head fixed in place, including cost of clamp holdfast and painting. Each 3.0 537.35 38 C-9/22 Shoes, bends or offsets for cast iron rain water down pipe, including fixing and painting. Each 3.0 326.00 39 C-9/15 Khuras on roof 2'x2'x6" (600 x 600 x 150 mm) Each 3.0 496.00 40 C-25/10+ Fabricationofheavysteelwork,withangle,tees,flatironround 11 iron and sheet iron for making trusses, girders, tanks, etc., including cutting, drilling, revitting, handling, assembling and fixing, including erection in position. (Steel Stairs) %kg 3161.9 13481.40 41 C-6/33(a-ii)Providingandlayingdampproofcourseofcementconcrete1:2: 4(usingcement,sandandshingle),includingbitumencoating:- (a) with one coat bitumen and one coat polythene sheet 500gauge ii) 2" thick (50 mm) %Sft 290.26 5060.00 42 C-13/9(i) Bitumencoatingtoplasteredor cementconcrete surface:-i)20 lbs. per 100 Sft. (9.07 Kg per Sq.m) %Sft 540.55 1025.70 Total of MRS ITEMS Total 1 NSI Providing and laying structural pad for foundation made of selected granular fill material (Mixture of 50% gravel and 50% sand of approved quality and grade) including placing, mixing, spreading and compaction of sub-base material to required depth, grade to achieve 95% maximum modified AASHTO dry density, including carriage of all material to site of work complete in all respect as approved by the Engineer incharge. P.Cft 9103.84 2 NSI Providing And Laying Glazed Ceramic Tiles For Flooring Size 12"X18”X3/8" Laid Over 3/4" Thick Cement Sand Mortar (1:2) I/C Filling Joints In White Cement And Matching Pigment I/C CuttingCharges(Masterorequivalent)CompleteInAllRespect As Approved & Directed By The Engineer Incharge. P.Sft 911.07 3 NSI Providingandlayingglazedceramictilestexturelightforskirting /dadosize12"x18”x3/8"laidover3/4"thickcementsandmortar (1:2) i/c filling joints in white cement and matching pigment i/c cuttingcharges(Masterorequivalent)completeinallrespectas approved & directed by the engineer incharge. P.Sft 3466.45 4 NSI Providing and laying porcelain tiles flooring 24"x24"x3/8" plain lightcolorlaidinwhitecementandmatchingpigmentover3/4" thick cement sand mortar (1:2) i/c filling joints in whitecement and matching pigment complete in all respect.(Master or equivalent). P.Sft 14332.16 5 NSI Providing and laying porcelain tiles skarting dado 24"x24"x3/8" plainlightcolorlaidinwhitecementandmatchingpigmentover 3/4" thick cement sand mortar (1:2) i/c filling joints in white cement and matching pigment complete in all respect.(Master or equivalent) P.Sft 874.22 6 NSI Providing and installing wooden HDF flooring size 8"x40" 8- 12mm thick complete in all respect as per drawings and direction by the Engineer Incharge. P.Sft 2795.64 7 NSI Providing And Fixing 3/4" Thick Pre-Polished Glaxy Black Granite Full Width Area Above 2 Sft Laid In White Cement Matching Pigment 3/4" Thick Cement Sand Mortar (1:2) I/C FittingJointsInWhiteCement&MatchingPigment I/CMaking GolaOnExposedEdgesCompleteInAllRespectAsApproved By The Engineer Incharge. (Stairs) P.Sft 144.69 8 NSI Providing and laying marble of Glaxy Black Granite size 2'x4'x3/8"laidinwhitecementandmatchingpigmentover3/4" thick cement sand mortar (1:2) i/c filling joints in whitecement and matching pigment and chemical polishing complete in all respect as approved & directed by the engineer incharge. P.Sft 562.60 9 NSI Providing and fixing UPVC Doors 38mm thickness i/c deluex matching color UPVC frame matt or glossy finish having color (white-Gray-Marble Gray-Oak Wood- Dard Oak Wood, Coffee Wood Honey Pine Wood-Mahagony-Marry Gold-Chocolate Brown-Honey Dew) i/c all accessories i/c mortice locks complete in all respect as approval by the Engineer Incharge. P.Sft 360.50 10 NSI Providing and fixing all types of glazed open able aluminum double door partly glazed and partly fixed with aluminum claddingsheetforprotectionagainststretcherhitcomprisingof anodized bronze color using deluxe section of M/S Al-Cop or PakistanCableshavingChowkatframeofsize100mmx44mm x 2mm (D10) with leaf frame of top & bottom size 80mm x 44mm x 2mm (D33) side leaf frame 80mm x 44mm x 2mm (D35). Center railframe 42mm x30mm x2mm (D52) partition for fixing strips 2mm (D33). Handles full width 2mm (D38B). corrugated aluminum strips all section of 2mm thickness i/c 8mm thick imported glass, imported hydraulic door closer, rubber gasketusing approvedqualitystopper, angle joints and hardware etc i/c cost of all labour & material complete in all respect as approved by Engineer Incharge. P.Sft 630.88 11 NSI Providing and laying tiles (rak 49-sgpinline-bl) dark grey color forskirting/dadosize18x36"laidover3/4"thickcementsand mortar (1:2) i/c filling joints in white cement and matching pigmenti/ccuttingchargescompleteinallrespectasapproved & directed by the engineer incharge. (rak or equivalent) P.Sft 3191.2 12 NSI Providing and fixing 12 mm thick plain glass partition (ghani, gunjorequivalent)withaluminiumframeofapprovedthickness 1.6 mm (chawla or equivalent) aluminium sections of wooden finishi/cthecostofholdingthepartitionswithslabbeams,walls and door closer machine, handle 18", silicone complete in all respect as per drawing & specifications/standard as per instruction of Engineer Incahrge. P.Sft 4149.6 13 NSI Providingandapplyingrockwallfinish,completeinallrespectas per drawing and instructions of engineer inccharge. P.Sft 9583.05 14 NSI Providing & Fixing M.S facade work having pipe section 6"x8" 14 swg frame, 2"x6" 16 swg & 4"x4" 16 swg pargola i/c paint completeinallrespectasperdrawing,design&asperdirection of engineer incharge. P.Job 1.00 15 NSI Providing and fixing 12 mm thick plain glass partition (ghani, gunj or equivalent) with frameless 12 mm glass door having outer frame of1.6mm almuniumsectioninwoodenfinishwith diffuser sheet i/c the cost of holding the partitions and door closer machine, handle 18", complete in all respect as per drawing&specifications/standardasperinstructionofEngineer Incahrge. P.Sft 2871.95 16 NSI Providing and fixing ply wood partition, 1/2" thick ply wood doublesheet,2'x2'woodenframemadeof2"x2"woodenstrips, gola at ends i/c polishing complete in all respect as per drawings/design and instructions of engineer incharge P.Sft 2291.24 17 NSI Providing and fixing of False ceiling consisting of lamenated GypsumBoard (onesidelaminated)of size600mmx600mm x7.5mm over'aluminium Tee's 1"x1"sizeat2'-0"x2-0"center to center longituidlnally and transversally &alminium angle of size 1" x 1" at cornes/ends (concealed frame),including all accessries such as steel hanging wire, hooks, screws,nails, rowel plugs, Cross Joints etc. complete in all respect,and as approved by the Engineer Incharge. P.Sft 16840.46 18 NSI ProvidingandfixingofFalseceilingofplasterofparisincluding finishes as per drawings/design and instructions of engineer incharge. complete in all respect P.Sft 777.65 CONSTRUCTION OF ADMIN SECTION, UET LAHORE DISTRICT LAHORE ENGINEER'S COST ESTIMATE ELECTRICAL WORKS Total Item Unit Rate Description Unit Qty Amount No. (Rs.) (Rs.) (i) (ii) (iii) (iv) (v) (vi) SECTION - A DISTRIBUTION BOARDS Supply at site, fabrication, installation, testing and commissioning of Main Distribution Board (MDB) , made of sheet steel 14 SWG, degreased and derusted, with 2 coats of antirust paint, 2 coats of powdercoatedpaintofapprovedcolour,protectionclassificationIP-44, totally enclosed indoor floor mounting cubicle type in free standing design, with hinged door, handle including cost of all auxiliaries, internal wiring, designation lables on MCCBS, grounding bar suitable for system Voltage 415 V, 50 Hz, 3 Phase and neutral bus bars of 99.9% electrolytic copper, including cost of cable terminal blocks wiringfrom breakers, brass cableglands, allaccessories completein all respects. All incoming and outgoing breakers shall be accessible onlybyopeningthefrontdoorhavingfurtherM.S.sheetcovergaskets shall also be provided where necessary. All MCCBs shall be suitable to operate without any derating at 40°C ambienttemperatureandshallbeofonemakeonly.ThesidesofMDB shallalsohavelouversatbottomandtoponsidesofpanelforhotair exhaust,wiremeshetc.Thebackofthepanelshallbelockabledoor instead of bolted and shall conform to single line diagram C-A-01 MAIN DISTRIBUTION BOARD ( MDB ) INCOMING 01 No 400Amps TP MCCB RC-36kA with shunt trip (Adjustable) 01 Nos Digital Voltmeter scaled 0-500 Volts of appropriate sizes. 01 Nos. Voltmeter selector switch 03 Nos. Air cooled ring type Current Transformers ratio 400/5 Amps having suitable output and accuracy for Ammeter. 01 Nos. Ammeter selector switch 01 No Digital Ammeter scaled 0-800 Amps of appropriate sizes. 06 Nos. 2 Amp fuses 03 Nos. R-Y-B indication lamps. 04 Nos insulated copper bus bars of electrolytic copper 99.9% . 01 Nos Surge Protective Device( SPD) 3P& 1N Type-1 and 40kA rated . 01 Nos Phase failure and phase reversal relay. 01NoThermostaticallycontrolled230Volts robustexhaust fans6"/8" dia.tobeinstalledonfrontofMDBforhotairexhaustincludingcostof thermostatON-OFFswitcheswiremeshandallnecessaryaccessories / wiring, complete in all respects. OUTGOING 01- 125 Amps TP MCB RC=18KA Total Item Unit Rate Description Unit Qty Amount No. (Rs.) (Rs.) 06- 40 Amps TP MCCB RC=15KA 07- 80 Amps TP MCCB RC=15KA 02- 32 Amps TP MCB RC=15KA 03- 10 Amps SP MCB RC=10KA Automatic Power Factor Improvement Plant (PFIP) to be installed inside Main Distribution Board in the Electrical Room consisting of capacitors, Triple pole Air Break Contactors, HRC fuse bases and links,06stepsDigitaltypeAutomaticreactiverelaywithallnecessary protective devices, “ON” indication lamp, Digital Power Factor R.M., pushbuttons,auxiliarycontactors,hand/off/autoswitch,discharging chokes, control fuses, fuse puller. The sides of PFIP shall also have louversatbottomandtoponexternalsidesofpanelforhotairexhaust complete in all respect. (6 x 12.50 KVAR ) 75KVAR -------------------- = 75 KVAR Brass cable glands suitable for 4 core PVC/PVC cu.cond. cable Job 1 600/1000 V. grade as per drawings DISTRIBUTION BOARD DB-LGF1,DB-LFF1,DB-LSF1, DB-LGF2, C-A-02 DB-LFF2, DB-LSF2 Fabrication, supply at site, installation and commissioning of DistributionBoards(DB)concealedtypebackboxmadeofsheetsteel 16SWGanddoorof18SWG,withflexibleearthingstraps,degreased and de-rusted, zinc phosphated, finished with electro-static powder coating of 15 micron thickness in approved color, panel housing to complywithprotection class IP-54, concealed type,with hingeddoor, lockable handle, all auxiliaries, internal wiring, designation labels on MCCBS, earthing bar, numbering beads on the control wires, panel suitable for system Voltage 415 V, 50 Hz, 3 Phase and neutral, bus bars of 99.8% purity electrolytic copper, including cost of cable termination lugs, brass cable glands for incoming & outgoing cables, wiring from breakers, indication lamps, instruments and control all accessories complete in all respects. All incoming and outgoing breakers shall be accessible by opening the front door having additional M.S. sheet cover on breakers. Gasketsshallalsobeprovided wherenecessary. AllMCCBs shallbe suitabletooperatewithoutanyde-ratingat40°Cambienttemperature and shall be of one make only and not a mixture of more than one make. Circuits layout shall conform to the single line diagrams INCOMING 01-40 Amps TP MCCB RC=18KA 03 - 2 Amps Protection fuses. 03- R-Y-B indication lamps. OUTGOING 06-10Amps SP MCB RC=10kA 08-16Amps SP MCB RC=10kA 10-20Amps SP MCB RC=10kA 01- 20 Amps TP MCB RC=10 KA Job 6 DISTRIBUTION BOARD DB-PGF1,DB-PFF1,DB-PSF1,DB-PGF2,DB- C-A-03 PFF2, DB-PSF2 Description same as item no:A06 but with following components. INCOMING 01-80 Amps TP MCCB RC=18KA 03 - 2 Amps Protection fuses. 03- R-Y-B indication lamps. OUTGOING 16-10Amps SP MCB RC=10kA 14-16Amps SP MCB RC=10kA Total Item Unit Rate Description Unit Qty Amount No. (Rs.) (Rs.) 10-20Amps SP MCB RC=10kA 03- 20 Amps TP MCB RC=10 KA Job 6 Sub Total Part -A Rs. SECTION - B LIGHT FIXTURES Supply,installation,testingandcommissioningoffollowinglightfittings, ceiling,recessed,wallmountedmadeofMSbody22SWGdegreased andderustedwithwhiteenamellednonyellowingpaint.Completewith internal wiring, Grounding terminal , complete in all respects. C-B-01 2x28WattfluorescentlightfixturecompletewithT5lamps,Philipstype No. 2 TMS-215/228 or equivalent. C-B-02 1x28WattfluorescentlightfixturecompletewithT5lamps,Philipstype No. 1 TMS-215/128 or equivalent. C-B-03 1x18 Watt LED light fixture complete with driver and hanging arrangements, similar to Philips type GMP118 or equivalent( FOR No. 18 WASHROOM MIRROR LIGHT). C-B-04 1x36 Watt LED light fixture IP-65 rated, similar to Future technology light with hanging accesories or equivalent( FOR KITCHEN AND No. 16 OFFICE LOCATIONS-SPECIFIC). C-B-05 1x36 Watt LED light fixture complete with driver and hanging arrangements, similar to philips type GMP- 136 or equivilent( FOR No. 2 WASHROOM MIRROR LIGHT) C-B-06 1x5 watt LED reflector ceiling light fixture with frosted lens, complete No. 114 with driver, ROUND model or equivalent( FOR CORRIDORES). C-B-07 1x10wattLEDreflectorceilinglightfixturewithfrostedlens,complete No. 22 with driver, ROUND model or equivalent( FOR WASHROOMS). C-B-08 1x36wattLEDreflectorceilinglightfixturewithfrostedlenssize2'x2', No. 164 complete with driver, SQUARE model or equivalent( FOR OFFICES). C-B-09 1x18WattLEDfixture,similartoPierlitemake,140235CameaWHor No. 12 equivalent( FOR OUTDOOR WALLS) C-B-10 1x10WattLEDexitlight,similartoPierlitemodelStingrayST10MPor No. 10 equivalent. C-B-11 2X18Watt,EmergencyTwinSpotlight,Non-maintainedwith3hours No. 7 Battery Backup or equivalent. 368 Sub Total Part -B Rs. SECTION - C MISCELLANEOUS FITTINGS Supply,installation, testing &commissioning of Ceiling/ Exhaust fan. The ceiling/exhaust fan shall comprise circular fan metallic/ plastic body, metallic fan blades, down rod (if necessary) of suitable dia & length, AC capacitor, internal wiring, terminals all installation & operational accessories as per tender specifications, as per site requirements and as directed by the Engineer. C-C-01 56" dia ceiling fan suitable to give an air displacement of minimum 9000 Cu. ft./ min. Fan shall be made with 99% purity Copper windings. No. 1 Total Item Unit Rate Description Unit Qty Amount No. (Rs.) (Rs.) C-C-02 24"diabracketfanwithfanbracketsandcontrollingcord.Fanshallbe made with 99% purity Copper windings. No. 72 C-C-03 10 '' dia exhaust fan with plastic body,fan blades and louvers No. 14 C-C-04 12 '' dia exhaust fan with metallic body,fan blades and louvers No. 2 89 C-C-05 Fanhooktobeprovidedintheslabforcablepullingandinfuturefan installation. No. 78 Sub Total Part -C Rs. SECTION - D WIRING IN CONCEALED CONDUITS C-D-01 Distribution board to Switch WiringoflightcircuitfromDistributionBoardtoswitch,withThreenos. single core 2.5 Sqmm PVC insulated 450/750 volts grade stranded copper conductor cables in concealed PVC conduits (conduits partly shared) including PVC conduit, and conduit accessories etc. No. 36 C-D-02 Switch to light point & point to point wiring Wiring from switch to light or fan point with 3 nos. single core 1.5 SqmmPVCinsulated450/750Voltsgradestrandedcopperconductor cables in concealed PVC conduit including PVC conduit, Conduit accessories,etc.(conduit partly shared). No. 421 C-D-03 Switch to Switch Wiringfrom switchto switch with3nos.singlecore2.5SqmmPVC insulated 450/750 Volts grade stranded copper conductor cables in concealed PVC conduit including PVC conduit, Conduit accessories,etc.(conduit partly shared). No. 82 C-D-04 Distribution board to General Purpose ( 5A/13A) socket Wiring of circuit from Distribution Boardto5A/13A,230Voltswith3 nos. single core 4 Sqmm PVC insulated 450/750 Volts graded , 2&3 pin switched socket, stranded copper conductor cables in concealed PVC conduit, including conduit accessories, etc(conduit partly shared) No. 188 C-D-05 Socket to Socket Wiringfrom5Amps,2&3pinsockettosocketwith3nos.singlecore 2.5SqmmPVCinsulated450/750Voltsgradesolidorstanerdcopper conductor cables in concealed PVC conduit including PVC conduit,Conduit accessories, etc complete. (conduit partly shared) No. 75 C-D-06 Distribution board to 15Amps socket Wiringof circuit from distribution boardto20A,230Volts,DPswitch with 3 nos. single core 4 Sqmm PVC insulated 450/750 Volts grade No. 15 stranded copper conductor cables in concealed PVC conduit including C-D-07 Distribution board to 20Amps switch for 2T A/Cs socket Wiringof circuit from distribution boardto20A,230Volts,DPswitch with 3 nos. single core 6 Sqmm PVC insulated 450/750 Volts grade strandedcopperconductorcablesinconcealedPVCconduitincluding PVCconduit,Conduitaccessories,etc(conduitpartlysharedfor2ton A/C) (Optional) No. 1 Total Item Unit Rate Description Unit Qty Amount No. (Rs.) (Rs.) Sub Total Part -D Rs. SECTION-E LT CABLES Supplyatsite,installation,testingandcommissioningofPVCinsulated non armoured copper conductor cable 600 / 1000 Volt grade (or otherwise mentioned in cable description ) in prelaid conduits / trenches to be installed as per routes shown on drawings including costofallnecessarymaterials,connections,identificationtags,cables lugsproperlycrimpedat both endsforthefollowingsizescompletein allrespects.Actuallengthofcablestobeinstalledshallbepractically measuredatsitebytheContractor,dulyauthenticatedbytheEngineer beforeplacingtheorderwiththemanufacturer,however,approximate lengthofcablesareshownherewith.Paymentsshallbemadeasper actual length installed. C-E-01 185 sq mm , 4 core PVC/PVC stranded copper conductor cable R.Mtr 6 5 C-E-02 25 sq mm , 4 core PVC/PVC stranded copper conductor cable R.Mtr 1 15 C-E-03 16 sq mm , 4 core PVC/PVC stranded copper conductor cable R.Mtr 1 25 3 Core Cable PVC/PVC C-E-04 3 core 2.5mmsq Cu/PVC/PVC R.Mtr 3 5 Sub Total Part -E Rs. SECTION - F WIRING ACCESSORIES Supplyat site,installation, testingand commissioning of thefollowing wiring accessories, complete in all respects. C-F-01 10Amps,250Voltsoneway,Oneganglightcontrolswitchesincluding appropriate size concealed MS, powder coated back box. No. 15 C-F-02 10Amps,250Voltsoneway,Twoganglightcontrolswitchesincluding appropriate size concealed MS, powder coated back box. No. 23 C-F-03 10 Amps, 250Volts one way, Three gang light control switches including appropriate size concealed MS, powder coated back box. No. 12 C-F-04 10Amps,250Voltsoneway,Fourganglightcontrolswitchesincluding appropriate size concealed MS, powder coated back box. No. 30 C-F-05 10Amps,250Voltsoneway,Fiveganglightcontrolswitchesincluding appropriate size concealed MS, powder coated back box. No. 13 C-F-06 10Amps, 250Volts one way,Sixganglightcontrolswitchesincluding appropriate size concealed MS, powder coated back box. No. 8 C-F-07 10Amps,250Voltsoneway,Eightganglightcontrolswitchesincluding appropriate size concealed MS, powder coated back box. No. 14 C-F-08 10Amps,250Voltstwoway,oneganglightcontrolswitchesincluding appropriate size concealed MS, powder coatedback box. No. 3 118
Description: