ebook img

Archangel Raphael and Saint Marina - Coptic Orthodox Church PDF

33 Pages·2017·1.57 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Archangel Raphael and Saint Marina - Coptic Orthodox Church

Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON Type of Document FINAL Project Number HAM-00801245-F0 Project Name D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON Prepared By: Terri Willert, Hons. B.A. Reviewed By: Netta Benazon, M.Sc. P.Eng. & Ron Taylor, M.Sc., C. Chem., CIH EXP Services Inc. 80 Bancroft StreetHamilton, Ontario L8E 2W5 Canada Date Submitted December 19, 2017 Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 D-6 Compatibility - Air Quality Assessment Version Date Revision Description Prepared By Reviewed By Netta Benazon and 1.0 19/12/2017 Final Terri Willert Ron Taylor i Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 Legal Notification This report was prepared by EXP Services Inc. for the account of Archangel Raphael and Saint Marina - Coptic Orthodox Church. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. EXP Services Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this project ii Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 Table of Contents 1 Introduction ........................................................................................................................ 1 2 Description of Development and Surrounding Area ..................................................... 2 2.1 Proposed Development ....................................................................................................... 2 2.2 Nearby Industries – Database Searches ............................................................................. 2 2.3 Site Visit Observation ........................................................................................................ 10 3 Provincial Guidelines and Regulations ........................................................................... 7 3.1 D-Series of Guidelines ......................................................................................................... 7 3.1.1 Classification and Nearby Industries ................................................................. 7 3.2 Provincial Guidelines and Regulations for Potentially Incompatible Uses ........................ 11 3.2.1 Air Quality Contaminants ................................................................................. 11 3.2.2 Odour ............................................................................................................... 11 4 Assessment – Potential Air Quality Impacts .................................................................. 9 4.1 General Air Quality Contaminants ....................................................................................... 9 4.2 Odour ................................................................................................................................... 9 5 Conclusions & Recommendations ................................................................................ 10 6 References ....................................................................................................................... 11 7 General Limitations ......................................................................................................... 10 Appendices Appendix A - Figures TOC - i Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 1 Introduction EXP Services Inc. (EXP) was retained by Archangel Raphael and Saint Marina - Coptic Orthodox Church (Church) to conduct a D-6 Compatibility – Air Quality Assessment (Assessment) to assess the compatibility of the proposed location of the Coptic Orthodox Church Canada at 1160 Blair Road, Burlington, ON, hereinafter referred to as the Subject Site. The assessment has been undertaken to support City of Burlington zoning approval requirements. The Subject Site is rectangular in shape and measures approximately 1.7 hectares (4.1 acres) in area and is currently occupied by a two-storey industrial/commercial building with approximately 7,205 m² (77,555 ft²) of floor area. The Site building is currently occupied by various commercial/light industrial tenants including: • Creative Edge Dance Studio; • RDC (Responsible Distribution Canada) (office); • Ciscon Landscaping (showroom, office and yard); • Body by PT (exercise gym); • Canadian Dance Company; • Burlington Movers (storage and office); • Eurostar Renos; • Absolute Custom Steel Fabrications (workshop); • Insatax (office); • Nuway Software (office), Three (3) of the units were vacant, two (2) of which were located on the second floor. The building is surrounded by a parking lot to the north, south, east and west of the building. Storage containers were observed at the south and northwest portion of the parking area. Parking areas surround the building on all sides. The development plan, surrounding industrial activities and provincial regulations and guidelines have been considered in this Assessment. 1 Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 2 Description of Development and Surrounding Area 2.1 Proposed Development The Subject Site is located at 1160 Blair Road and is situated on the southwest side of Blair Road opposite Landmark Road, in Burlington, Ontario. The adjacent surrounding properties are mixed commercial and industrial properties. The Subject Site is rectangular in shape and measures approximately 1.7 hectares (4.1 acres) in area and is currently occupied by a two-storey industrial/commercial building with approximately 7,205 m² (77,555 ft²) of floor area. The Subject Site building is currently occupied by various commercial and light industrial tenants. Three (3) of the units are currently vacant, two (2) of which are located on the second floor. The proposed location of the Church at the Subject Site is within the current building at the location of the former Marcello’s Banquet Centre tenant, a ground floor space of about 305 m2. The Church will also occupy office space and meeting rooms on the second floor. Fixed pew seating for 220 congregants will be provided. The Subject Site is currently designated as GE1 under Comprehensive Zoning By-law 2020. The GE1 zoning designation does not include a Place of Worship as a permitted use. As such, the Church is seeking a site-specific zoning amendment to the GE1 zoning of the property at 116- Blair Road to allow for a Place of Worship as a permitted use at this location. The location and site plan of the Subject Site is shown in Figure 1 in Appendix A. 2.2 Nearby Industries – Database Searches A search of environmental risk databases (National Pollutant Reporting Inventory (NPRI), Compliance and Convictions (CONV), Environmental Activity and Sector Registry (EASR) and Environmental Compliance Approvals (ECAs) identified thirty-two addresses of interest from an air quality perspective that are located within 1000 m of the proposed development. The findings are detailed in Table 1 below. Table 1. Identified Industrial Facilities of Potential Air Quality Concern Location Company Database Activity ECA – Wardco Window and Door Manufacturing Air/Noise Inc., was approved in 2014 for ECA Air for: Wardco Window five (5) dust collectors servicing the wood and Door working machines; two (2) cutting saws, one Manufacturing (1) hunge prep machine, one (1) door router, 1157 Blair Road Inc. one (1) electric oven, two (2) weld cleaning Atlas Copco equipment, and three welding stations, Canada Inc. discharging within the building; and one (1) paint spray booth, for the application of solvent coatings. 2 Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 Location Company Database Activity Atlas Copco Canada Inc. was approved in 2003 for ECA Air for “one (1) in-situ bioremediation process to treat groundwater contaminated with chlorinated solvents by the injection of non-hazardous Biostimulation Compound(s) into the contaminated groundwater.” ECA – Air Pennzoil Quaker-State Canada Incorporated was approved in 2006 for ECA Air for: one (1) natural gas fired boiler; two (2) laboratory Pennzoil fume hoods; one (1) natural gas fire hot Quaker-State *1101 Blair water high pressure washer; one (1) natural Canada Road gas fired boiler; natural gas fired equipment Incorporated/QM for comfort heating; and, thirty-five (35) Environmental storage tanks for the storage of industrial oils and packaged products, exhausting into the atmosphere through vent pipes. ECA – Air EcoSynthetix Inc., is a renewable chemicals company specializing in bio-based materials. Two of their “flagship products are EcoSynthetix Inc., was approved in 2015 for ECA Air for: one (1) cyclone separator; one 3365 Mainway EcoSynthetix Inc (1) fluidized bed dryer equipped with a natural gas fired heater; one (1) high pressure cartridge filter serving the milling industry; three (3) laboratory fume hoods; and, natural gas fired comfort heaters, and other supporting equipment and processes. NPRI Gennum Corporation manufactures semi- conductor and other electronic components. Gennum ECA – Air *3435 Corporation Bosch Rexroth Canada Corp., a drive and Landmark Road Bosch Rexroth control technologies company was approved in 2004 for ECA Air for one (1) paint spray Canada Corp. booth for the application of solvent based coatings and exhausted systems. Airmax ECA – Air Airmax Compressor Services Ltd. sells and Compressor services air compressors and compressed Services Ltd. air treatment equipment, was approved in 3400 Landmark Kaidex 2008 for ECA Air for one (1) spray booth for Road Transportation the application of solvent based coatings Services Inc. with one (1) natural gas fired air make up unit. MVF: Matheson Valves 3 Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 Location Company Database Activity ECA – Air In 2004, 690661 Ontario Limited (CARSTAR) was approved in 2004 for ECA 690661 Ontario Air for two (2) paint spray booths, for the 3388 Mainway Limited application of solvent based coatings, (CARSTAR) equipped with a natural gas fired air make- up unit. Specialty Porcelain Company Limited, a tile manufacturer, was approved in 2003 for ECA Air for: one (1) exhaust system serving the hot caustic cleaning process, consisting of six (6) caustic cleaner tanks, two (2) hot rinse tanks, two (2) cold rinse tanks, and two (2) neutralizer tanks; one (1) natural gas fired drying oven twenty-two (22) unit Specialty heaters; multiple natural gas fired heaters Porcelain and furnaces; exhaust systems; natural gas 3466 Mainway Company fired drying ovens and boilers and, one (1) Limited grinding booth for minor manual grinding operations, complete with polyester filter material. In 2002, Specialty Porcelain Company Limited was convicted and sentenced to an 8,000.00 fine for the “discharging, causing or permitting the discharge of a contaminant namely particulate and failing to notify the Ministry”. ECA – Air Hunter Drums Limited, engaged in manufacturing and reconditioning industrial EASR – drums and containers made of various heating materials, including steel, fiber composition, system and polyurethanes, was either revoked or replaced in 2005 for ECA Air for six (6) paint spray booths for the application of solvent Hunter Drums based paints, one (1) 2-stage parts washer, 1121 Pioneer Limited equipped with a natural gas fired heater, Road Mauser Canada multiple natural gas fired ovens, and exhaust systems. Ltd. Mauser Canada Ltd., a steel drum and vinyl laminated sheet steel manufacturing facility, operating at a maximum production rate of up to 6336 drums per 12-hour shift, was approved for ECA Air in 2003 for: one (1) regenerative thermal oxidizer unit, six (6) spray booths which apply solvent based 4 Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 Location Company Database Activity coatings, eight (8) natural gas fired ovens, one (1) 2-stage parts washer, equipped with a natural gas fired heater, and three (3) exhaust systems. ECA - Air Bosch Rexroth Canada Corp. was approved in 2011 for ECA Air for: (1) paint spray booth for the application of solvent based coatings; Bosch Rexroth 3426 Mainway one (1) electrical drying oven; one (1) battery Canada Corp. charging station; fugitive emissions from parts washer; and, exhausted systems associated with the solder stations. ECA – Air L. A. Rubber Inc., a manufacturer of a full range of roll covers as well as fabricated urethane and rubber parts, linings and pulley lagging, was approved in 2009 for ECA Air *3466 for: three (3) natural fired ovens; one (1) L. A. Rubber Inc. Landmark Road baghouse dust collector; one (1) natural gas fired boiler; one (1) sand blasting room; one (1) urethane mixer; nine (9) natural gas fired radiant heaters; and, one (1) natural gas fired air make-up unit. ECA – Halton Recycling Ltd., a registered 9.24- *1122 Pioneer Halton Recycling Waste Hectare transfer/processing Waste Disposal Road Ltd. Disposal Site, was approved for and ECA Waste Site Disposal Site. ECA – Air Contro Valve Equipment Inc., ECA not available for review. Contro Valve HSP Graphics Ltd., was approved in 2001 Equipment Inc. for ECA Air for three (3) exhaust systems *3375 North HSP Graphics equipped fume hoods, each serving a Service Road Ltd. printing machine. Apex Apex Composites Inc., was approved in Composites Inc. 2009 for ECA Air for one (1) spray booth for the application of solvent based coatings, equipped with one (1) spray gun. NPRI The March 2015 ECA Air approved Thomson-Gordon Group, a non-metallic ECA - Air liquid cast elastomer products and specialty Thomson 3225 Mainway lubricant products manufacturing facility, to Gordon Group allow for the processes associated with the mixing and casting, adhesive bonding and curing, and welding and painting to be 5 Archangel Raphael and Saint Marina - Coptic Orthodox Church D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON HAM-00801245-F0 December 19, 2017 Location Company Database Activity discharged to air through the exhaust system. ECA – Air Pacific Westeel Racking Inc., a steel rack manufacturing facility, was approved in 2008 for ECA Air for the processes associated Pacific Westeel *3191 Mainway with steel cutting, punching, forming and Racking Inc. welding; painting operations; oven curing; and, evaporations, to be discharged to air through the exhaust system. ECA – 3166 Mainway was approved for a ECA Waste Waste Disposal Site. The registered 0.4 RPM Disposal hectare Waste Disposal Site used for the 3166 Mainway Environment Site transfer and processing of municipal special Ltd. waste limited to empty oil and antifreeze containers and residual oil and anti-freeze waste class number 254. ECA – Air Technical Coatings Co Limited, a contract Coater / Laminator of roll-based goods, was approved in 2000 for ECA Air for: fifty-seven (57) vents and exhausts serving a resin production facility; one (1) air collection hood above manilla resin tank; nine (9) carbon steel storage tanks, each having a storage capacity of 36,400 litres, exhausting into the atmosphere; one (1) exhaust system serving a paint filling station; one (1) exhaust system Technical serving four (4) process tanks and two (2) Coatings Co *1164 Walkers Limited sandmill tanks; and, one (1) dust collector Line equipped with pulse-jet filter cleaning Benjamin Moore mechanism and Eon microfibers filters. and Co., Limited Benjamin Moore and Co., Limited, was approved in 2006 for ECA Air for: one (1) alkyd paint manufacturing plant, identified as New Alkyd Plant; one (1) Small Scale Production Area discharging to the atmosphere; one (1) Tank Farm consisting of fifteen (15) tanks discharging into the atmosphere; and, one (1) natural gas-fired boiler, identified as HE-2, serving the former resin plant building. Dan's Welding & ECA – Air Dan's Welding & Fabricating Limited, a 3485 Mainway Fabricating custom fabricated sheet metal products Limited manufacturing facility, was approved in 2001 6

Description:
Archangel Raphael and Saint Marina - Coptic Orthodox Church. D-6 Compatibility – Air Quality Assessment – 1160 Blair Road, Burlington, ON. HAM-00801245-F0. December 19, 2017 ii. Legal Notification. This report was prepared by EXP Services Inc. for the account of Archangel Raphael and Saint.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.