ebook img

Arc 410c Arc 650c Arc 810c PDF

38 Pages·2010·1.36 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Arc 410c Arc 650c Arc 810c

Arc 410c Arc 650c Arc 810c Origo Instruction manual Instrucciones de uso Manuel d’instructions 0349301163 100401 Validforserialno.734,749,751 ENGLISH .............................................. 3 FRANÇAIS ............................................. 12 ESPAÑOL .............................................. 21 Rightsreservedtoalterspecificationswithoutnotice. Sousréservedemodificationssansavispréalable. Reservadoelderechodecambiarlasespecificacionessinprevioaviso. -- 2 -- ENGLISH 1 DIRECTIVE ........................................................ 4 2 SAFETY ........................................................... 4 3 INTRODUCTION ................................................... 6 4 TECHNICAL DATA ................................................. 6 5 INSTALLATION .................................................... 7 5.1 Connectingtomains ....................................................... 7 6 OPERATION ....................................................... 8 6.1 MMAwelding ............................................................. 8 6.2 TIGwelding............................................................... 8 6.3 ArcAirGouging ........................................................... 8 6.4 A11paneloperation........................................................ 9 6.5 A12paneloperation ....................................................... 9 6.6 Wiredremotecontroloperation .............................................. 9 6.7 Controlsandconnections ................................................... 9 6.8 Overheatingprotection ..................................................... 10 7 MAINTENANCE .................................................... 11 8 ORDERING OF SPARE PARTS ...................................... 11 DIAGRAM ............................................................ 30 ACCESSORIES ....................................................... 37 -- 3 -- TOCe GB 1 DIRECTIVE DECLARATIONOFCONFORMITY ESABAB,WeldingEquipment,SE--69581Laxå,Sweden,givesitsunreservedguaranteethatweld- ingpowersourceOrigoTMArc410c,Arc650c,Arc810cfromserialnumber734,749,751arecon- structedandtestedincompliancewiththestandardEN60974--1andEN60974--10inaccordance withtherequirementsofdirective(2006/95/EC)and(2004/108/EEC). ------------------------------------------------------------------------------------------------------------------------------------ Laxå2007--10--01 KentEimbrodt GlobalDirector EquipmentandAutomation 2 SAFETY UsersofESABweldingequipmenthavetheultimateresponsibilityforensuringthatanyonewho worksonorneartheequipmentobservesalltherelevantsafetyprecautions.Safetyprecautions mustmeettherequirementsthatapplytothistypeofweldingequipment.Thefollowingrecommen- dationsshouldbeobservedinadditiontothestandardregulationsthatapplytotheworkplace. Allworkmustbecarriedoutbytrainedpersonnelwell--acquaintedwiththeoperationofthewelding equipment.Incorrectoperationoftheequipmentmayleadtohazardoussituationswhichcanresult ininjurytotheoperatoranddamagetotheequipment. 1. Anyonewhousestheweldingequipmentmustbefamiliarwith: (cid:1) itsoperation (cid:1) locationofemergencystops (cid:1) itsfunction (cid:1) relevantsafetyprecautions (cid:1) welding 2. Theoperatormustensurethat: (cid:1) nounauthorisedpersonisstationedwithintheworkingareaoftheequipmentwhenitis startedup. (cid:1) no--oneisunprotectedwhenthearcisstruck 3. Theworkplacemust: (cid:1) besuitableforthepurpose (cid:1) befreefromdraughts 4. Personalsafetyequipment (cid:1) Alwayswearrecommendedpersonalsafetyequipment,suchassafetyglasses,flame--proof clothing,safetygloves. (cid:1) Donotwearloose--fittingitems,suchasscarves,bracelets,rings,etc.,whichcouldbecome trappedorcauseburns. 5. Generalprecautions (cid:1) Makesurethereturncableisconnectedsecurely. (cid:1) Workonhighvoltageequipmentmayonlybecarriedoutbyaqualifiedelectrician. (cid:1) Appropriatefireextinquishingequipmentmustbeclearlymarkedandcloseathand. (cid:1) Lubricationandmaintenancemustnotbecarriedoutontheequipmentduringoperation. -- 4 -- Arce GB WARNING! Readandunderstandtheinstructionmanual beforeinstallingoroperating. WARNING ARCWELDINGANDCUTTINGCANBEINJURIOUSTOYOURSELFANDOTHERS.TAKEPRECAU- TIONSWHENWELDING.ASKFORYOUREMPLOYER’SSAFETYPRACTICESWHICHSHOULDBE BASEDONMANUFACTURERS’HAZARDDATA. ELECTRICSHOCK-- Cankill (cid:1) Installandearththeweldingunitinaccordancewithapplicablestandards. (cid:1) Donottouchliveelectricalpartsorelectrodeswithbareskin,wetglovesor wetclothing. (cid:1) Insulateyourselffromearthandtheworkpiece. (cid:1) Ensureyourworkingstanceissafe. FUMESANDGASES-- Canbedangeroustohealth (cid:1) Keepyourheadoutofthefumes. (cid:1) Useventilation,extractionatthearc,orboth,totakefumesandgasesawayfromyourbreathingzone andthegeneral area. ARCRAYS-- Caninjureeyesandburnskin. (cid:1) Protectyoureyesandbody.Usethecorrectweldingscreenandfilterlens andwearprotective clothing. (cid:1) Protectbystanderswithsuitablescreensorcurtains. FIREHAZARD (cid:1) Sparks(spatter)cancausefire.Makesurethereforethatthereareno inflammablematerialsnearby. NOISE-- Excessivenoisecandamagehearing (cid:1) Protectyourears.Useearmuffsorotherhearingprotection. (cid:1) Warnbystandersoftherisk. MALFUNCTION-- Callforexpertassistanceintheeventofmalfunction. READANDUNDERSTANDTHEINSTRUCTION MANUALBEFOREINSTALLINGOROPERATING. PROTECTYOURSELFANDOTHERS! ESAB can provide you with all necessary welding protection and accessories. WARNING! Donotusethepowersourceforthawingfrozenpipes. Thisproductissolelyintendedforarcwelding. Donotdisposeofelectricalequipmenttogetherwithnormalwaste! InobservanceofEuropeanDirective2002/96/EConWasteElectricalandElectronic Equipmentanditsimplementationinaccordancewithnationallaw,electricalequipment thathasreachedtheendofitslifemustbecollectedseparatelyandreturnedtoan environmentallycompatiblerecyclingfacility.Astheowneroftheequipment,youshould getinformationonapprovedcollectionsystemsfromourlocalrepresentative. ByapplyingthisEuropeanDirectiveyouwillimprovetheenvironmentandhumanhealth! -- 5 -- Arce GB 3 INTRODUCTION OrigoTM Arc 410c, Arc 650c, Arc 810c are chopper controlled welding rectifiers designed for welding with coated electrodes, TIG welding and arc air gouging. The welding rectifiers can cooperate with following remote control devices: (cid:1) wired MMA1, MMA2, AT1, AT1 CoarseFine (cid:1) wireless N02 (only with panel A12) OrigoTM Arc equipped with panel A12 is version with display, that allows current setting to be read from the front of the rectifier. 4 TECHNICAL DATA OrigoTM Arc 410c OrigoTM Arc 650c OrigoTM Arc 810c 230/400--415/500V 230/400--415/500V 230/400--415/500V 3∼50Hz 3∼50Hz 3∼50Hz Voltage 230/440--460/550V 230/440--460/550V 230/440--460/550V 3∼50Hz 3∼50Hz 3∼50Hz Maximumload 35%dutycycle 400A/36V 650A/44V 800A/44V 60%dutycycle 310A/33V 490A/40V 630A/44V 100%dutycycle 240A/30V 400A/36V 500A/43V Settingrange 20A/20V--400A/36V 20A/20V--650A/44V 20A/20V--800A/44V Opencircuitvolt. 53--70V 53--70V 53--70V Opencircuitoutput at400V 390W 510W 520W Powerfactor (maxcurrent) 0,90 0,90 0,90 Efficiency (maxcurrent) 74% 77% 76% Operatingtemperature --10to+40˚C --10to+40˚C --10to+40˚C Enclosureclass IP23 IP23 IP23 Applicationclass Weight 157kg 223kg 245kg Dimens.lxwxh 1310/800/780 1310/800/780 1310/800/780 Dutycycle Thedutycyclereferstothetimeasapercentageofaten--minuteperiodthatyoucanweldatacer- tainloadwithoutoverloading. Enclosureclass TheIPcodeindicatestheenclosureclass,i.e.thedegreeofprotectionagainstpenetrationbysolid objectsorwater.EquipmentmarkedIP23isdesignedforindoorandoutdooruse. Applicationclass Thesymbol indicatesthatthepowersourceisdesignedforuseinareaswithincreased electricalhazard. -- 6 -- Arce GB 5 INSTALLATION The installation must be executed by a professional. WARNING! Thisproductisintendedforindustrialuse.Inadomesticenvironmentthisproductmaycauseradio interference.Itistheuser’sresponsibilitytotakeadequateprecautions. Lifting instructions Thepowersupplyshouldbeliftedbymeansofitsliftingeye. Thehandleisonlyintendedforpulling italongtheground. (cid:1) Check that the welding rectifier is configured for the available mains supply before connecting it to the mains. (cid:1) See Connecting to mains for cable rating and fuse rating. (cid:1) Connect the mains cable to the rectifier according to the relevant regulations and install a suitable fuse in the main fuse box. (cid:1) Make sure the welding rectifier is not covered or positioned so that cooling is obstructed. 5.1 Connecting to mains -- 7 -- Arce GB OrigoTMArc410c OrigoTMArc650c OrigoTMArc810c Frequency 50Hz 50Hz 50Hz Voltage 230/400--415/500V 230/400--415/500V 230/400--415/500V Currentat 100%dutycycle 27/16/13A 57/33/26A 71/41/33A 60%dutycycle 38/22/18A 69/40/32A 99/57/46A 35%dutycycle 54/31/25A 109/63/50A 130/75/60A Fuse,slow 63/25/20A 80/50/35A 100/63/50A Cablearea(4xmm2) 10/4/4 25/10/6 35/10/10 OrigoTMArc410c OrigoTMArc650c OrigoTMArc810c Frequency 60Hz 60Hz 60Hz Voltage 230/440--460/550V 230/440--460/550V 230/440--460/550V Currentat 100%dutycycle 27/14/12A 57/30/24A 71/37/30A 60%dutycycle 38/20/16A 69/36/29A 99/52/42A 35%dutycycle 54/28/23A 109/57/46A 130/68/55A Fuse,slow 63/25/20A 80/50/35A 100/63/50A Cablearea(4xmm2) 10/4/4 25/10/6 35/10/10 NB:ThemainscableareasandfusesizesasshownaboveareinaccordancewithSwedish regulations.Theymaynotbeapplicableinothercountries: makesurethatthecableareaandfuse sizescomplywiththerelevantnationalregulations. 6 OPERATION (cid:1) Select suitable earth and return cables and connect them to the terminals marked “+” (5) and “--” (6) on the front of the rectifier. Connect the return cable to the work piece. (cid:1) Set switch (1) to position ”I”. The lamp (3) will light, the fan and the contactor will operate in several seconds. 6.1 MMA welding Set switch (4) to . In MMA mode implicitly “anti stick” function is ON. It prevents of sticking the electrode to workpiece during arc striking. 6.2 TIG welding Set switch (4) to . In TIG mode output voltage of machine is ON after the welding torch switch is pressed. After arc initiation current rises from minimum possible value until it reaches the value set by operator. 6.3 Arc Air Gouging Set switch (4) to . In Arc Air Gouging mode current should be set close to maximum value in order to ensure proper gouging conditions. -- 8 -- Arce GB 6.4 A11 panel operation (cid:1) Select the welding method using the switch (4) (cid:1) Set the welding current using the knob (3), it’s dial is scaled in Amps (cid:1) Set the HOT START duration with knob (2) (cid:1) Set the ARC FORCE value with knob (1) 6.5 A12 panel operation (cid:1) Select the welding method using the switch (4) (cid:1) Set the welding current using the knob (3), if switch (6) is set towards “A”, then value of current is displayed on display (7) (cid:1) Set the HOT START duration with knob (2) (cid:1) Set the ARC FORCE value with knob (1) A12 panel incorporates remote current control receiver that cooperates with N02 transmitter. In oder to set the current remotely, the following steps must be undertaken: (cid:1) set switch (5) to “|)))” (cid:1) set demanded current with knob on N02 transmitter (cid:1) put N02 on the work piece and make sure there is good electric contact between work piece and N02 metal bottom (cid:1) touch the metal disk on top of N02 with the electrode, hold it still untill N02 control lamp turns off (changes of current value during ttransmition should be visible on A12 display) 6.6 Wired remote control operation (cid:1) Connect wired remote control unit to socket (2) (wired remote control mode is turned on automatically) (cid:1) Set demanded current with knob on control unit (if A12 panel mounted, changes of current value during transmition should be visible on A12 display) 6.7 Controls and connections 6.7.1 OrigoTM Arc 1. Mains supply switch 2. Wired remote control socket 3. White lamp, power supply ON 4. Yellow lamp, thermal cut--out 5. “+” output terminal 6. “--” output terminal 7. TIG torch control socket 8. Panel (A11 / A12) -- 9 -- Arce GB 6.7.2 A11 panel 1. ARC FORCE knob 2. HOT START knob 3. Current setting knob 4. Method selector switch: Arc Air Gouging, MMA, TIG 6.7.3 A12 panel 1. ARC FORCE knob 2. HOT START knob 3. Current setting knob 4. Method selector switch: Arc Air Gouging, MMA, TIG 5. Local / wireless remote control switch 6. A/V measurement switch 7. Display 6.8 Overheating protection If the internal temperature becomes too high, the welding is interrupted and disabled. This state is indicated by permanent lighting of the orange indicating lamp on the front of the unit. It resets automatically when the temperature falls down. -- 10 -- Arce

Description:
Arc 650c. Arc 810c. Origo . Instruction manual. Manuel d'instructions . designed for welding with coated electrodes, TIG welding and arc air gouging
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.