Or mco ORTHODONTIC PRODUCTS CATALOG A WORLD OF BEAUTIFUL SMILES™ We at Ormco are dedicated to developing innovative products and services that improve the clinician’s opportunity to achieve excellent results, in the least amount of time, in the fewest appointments and with the greatest patient comfort. Dear Doctor and Staff Member: For more than 45 years, Ormco has partnered with the orthodontic profession to deliver a wide array of high-quality, innovative products backed by superior customer service. Updating the Ormco products catalog is important to keep you aware of the latest products and techniques in the industry. Ormco’s innovative solutions exemplify our continuing efforts to improve the efficiency and comfort of your care and the beauty and stability of your results. Our partnership with you in this endeavor makes our work here at Ormco even more satisfying because our mission of developing quality, progressive products goes hand-in-hand with your clinical and personal goals. That’s why we invest heavily in research and development, set trends rather than follow them and focus on how our products perform in your hands to provide the best clinical outcomes. We are proud that so many advanced technologies used in orthodontic practices around the globe today originated through our research and development efforts with guidance from our visionary clinicians. From the revolutionary treatment philosophy of the Damon®System to cutting-edge digital solutions like Insignia™Custom-Designed Orthodontics, Ormco has a rich history of providing innovative products and services to help elevate the standard of patient care and prepare for even greater advancements yet to come. Ormco is also committed to your professional development and practice growth. To that end, we offer numerous educational events worldwide such as the Gorman Institute, Damon System seminars and VectorTAS™ temporary anchorage courses, as well as publish Clinical Impressions®– now in its 16th year. Through these services, our comprehensive product line and passionate dedication to the advancement of the profession, we will continue to assist you in setting new standards of clinical excellence every day you practice. Thank you for choosing Ormco products for your practice and for your patients. Sincerely yours, Donald L. Tuttle President, Specialty Products Group Sybron Dental Specialties Ormco • 800-854-1741 • 714-516-7400 • www.ormco.com Ormco Corporate Headquarters 1717 West Collins Avenue Orange, CA 92867 USA Tel: (714) 516-7400 Fax: (714) 516-7543 Fax: (714) 516-7526 (Int’lDepartment) Subsidiary Allesee Orthodontic Appliances P.O. Box 725 13931 Spring Street Sturtevant, WI 53177 USA Tel: (262) 886-1050 Tel: (800) 262-5221 Fax: (262) 886-6879 P.O. Box 200 6 Niblick Road Enfield, CT 06082 USA Tel: (860) 741-3745 Fax: (860) 741-7655 International Offices Ormco Europe B.V. European Headquarters Basicweg 20 NL-3821 BR Amersfoort NETHERLANDS Tel: 31 33 453 6161 Fax: 31 33 457 0196 Ormco de Mexico S.A. de C.V. Insurgentes Sur 263, 5 Piso Colonia Roma 06700 MEXICO Tel: 52 555 264 2125 Fax: 52 555 264 2120 Ormco Japan 29-24 Honkomagome 2-Chome, Bunkyo-ku, Tokyo 113-0021 JAPAN Tel: 81 3 3945 0065 Fax: 81 3 3947 0065 Ormco Pty Limited Unit 11, 112-118 Talavera Rd. North Ryde, NSW 2113 AUSTRALIA Tel: 61 2 9870 7344 Fax: 61 2 9870 7600 Ormodent SA 12, rue du Sergent Bobillot, P.B. 37 F-93101 Montreuil, Cedex FRANCE Tel: 33 1 49 88 60 60 Fax: 33 1 49 88 60 88 Ormco • 800-854-1741 • 714-516-7400 • www.ormco.com CONTENTS SECTION 1 Appliance Systems SECTION 2 Aesthetic Brackets SECTION 3 Buccal Tubes SECTION 4 Bands & Crowns SECTION 5 Archwires SECTION 6 Adhesives/Curing Lights SECTION 7 Elastics /Power Products SECTION 8 Intraoral /Noncompliance SECTION 9 Extraoral Appliances SECTION 10 Supplies SECTION 11 AOA SECTION 12 Practice Development SECTION 13 Index Section One Appliance Systems page 2 Damon System page 24 Tweed page 6 Damon 3MX page 25 Alexander Signature Line page 8 Damon 3 page 26 Mini-Wick System page 10 Titanium Orthos page 28 Straight-Wire Appliances page 13 Orthos page 30 Straight-Wire Synthesis page 16 Bios page 33 Mini-Twin page 18 Orthos AP page 36 Mini-Twin VS page 19 Insignia page 37 Twin page 20 Mini Diamond Twin page 39 Attract page 22 Mini Diamond VS page 23 Diamond Full-Size Twin 1 2 APPLIANCE SYSTEMS SECTION PAGE Damon System It Begins With The Face The Damon philosophy recognizes that to limit diagnosis exclusively to hard-tissue cephalometric criteria ignores soft-tissue symmetry. Of course, achieving the best facial balance possible must be done in conjunction with conven- tional treatment goals. The Damon System offers a unique mechanical system – a passive conduit – that permits low forces to work in conjunction with the muscles of the face, tongue, bone and tissue. Low forces minimize discomfort and greatly increase the types of cases that can be treated to a symmetrical facial result without high-force expansion or extractions. Pretreatment Posttreatment – 14 months, 2 weeks APPLIANCE SYSTEMS 1 3 SECTION PAGE A biologically sensible way of moving teeth for improved tooth position and facial aesthetics. The Damon System is more than exceptional self-ligating brackets. It’s the proven combination of passive self-ligating brack- ets, high-tech archwires and minimally invasive treatment protocols that work together in a low-friction, low-force system. Research indicates that optimum orthodontic forces should be just high enough to stimulate tooth movement without cut- ting off the vascular supply to the periodontal ligament.* The Damon System is designed to allow the clinician to optimize these low forces throughout all phases of treatment, providing remarkable advantages over traditional orthodontic approaches – faster treatment time, very few auxiliary appliances, and greater patient comfort. * Profitt, W. R. and Field, H. W. : The Biological Basis of Orthodontic Therapy, Contemporary Orthodontics, pp. 266-288, 1993 The Damon Difference Appliances with ligatures Damon self-ligating system Elastic ligatures create friction and Damon passive self-ligating brackets allow freedom of movement and thus binding and require more force and faster results with gentler forces. It’s the biologically sensible way to more-frequent adjustments. improve tooth position and facial aesthetics. Clinically Proven Advantages Damon patient models and CT image • Up to 7 months’ faster treatment time 41mm • Significantly fewer appointments • Significantly greater patient comfort • Significantly higher quality results 55mm Average Arch Leveling and Total Treatment Times 6.0 Leveling 27.5 Total Time 3.2 Leveling Expanding the Possibilities...without 20.3 Total Time RPEs or Surgery 0 5 10 15 20 25 30 Months With a reduced need for auxiliary appliances or invasive procedures, the Damon System benefits both you and your patients. In this featured Conventional Damon Damon case, the patient gained 14 mm of posterior arch width without rapid palatal expansion or surgery. The posttreatment CT image shows transverse arch development and normal alveolar bone on lingual and buccal surfaces. Ormco • 800-854-1741 • 714-516-7400 • www.ormco.com 1 4 APPLIANCE SYSTEMS SECTION PAGE The Damon System Phases of Treatment Initial Phase Working Phase Final Phase •Begin Leveling •Complete Leveling and Alignment •Complete Torque Control •Begin Alignment •Complete Rotational Control •Complete Space Consolidation •Begin Rotational Control •Begin Torque Control •Develop Patient-Specific Arch Form •Begin Arch Development •Begin Space Consolidation •Conduct Final Detailing •Continue Arch Development Damon cases are begun with a small- By filling the slot in a passive self- dimension archwire in a large bracket Gaining rotational control and ligating appliance, complete torque lumen. By removing friction and beginning torque control is achieved control is achieved while low-friction binding from the system, crowded by using full-depth archwires. Passive sliding mechanics completes space teeth unravel gently and comfortably self-ligation facilitates rapid space consolidation. The final arch form is with extremely light forces. closure and fosters arch-form develop- determined by each patient’s unique ment via the low-force archwires physiological tooth position. operating in a low-friction environment. The Clinical Experience “What is so striking about the Damon System is that I can start my cases with an .014 Ni-Ti and the teeth will level and align far quicker than I have ever seen with conventional braces and with much less discomfort. I am amazed how passive self-ligation combined with light, constant forces throughout treatment work with the muscles of the face to produce a lip-bumpering effect on the upper and lower incisors. Instead of incisors dumping labially, posterior expansion is produced.” – Alan Bagden, DDS, MSD, Springfield, Virginia “Rotations and torque control are easily achieved when full-depth archwires are introduced. When closing space in a nearly friction-free system, teeth slide along the wire and the Damon appliance really comes into a class of its own. We are absolutely convinced that these brackets not only align teeth faster but also keep teeth aligned far better than ligature ties or active brackets during space closure. They eliminate the need to go back to Ni-Ti wires to realign teeth after spaces have been closed, thus ensuring an efficient final phase of treatment.” – Alan Pollard, MDSc, Melbourne, Australia “My finished tooth positioning has never been better than with the Damon appliance, and I finish with as much control of the teeth as I did with conventional appliances. I hear doctors question how it’s possible to detail final occlusions in a passive system. When you close the door on an .019 x .025 stainless steel archwire in an .022 x .0275 slot, the wire is fully engaged and expresses the desired bracket prescription. That means brackets need to be placed or replaced with accuracy. As with all appliance systems, proper bracket positioning is a must.” – Tom Pitts, DDS, Reno, Nevada Ormco • 800-854-1741 • 714-516-7400 • www.ormco.com APPLIANCE SYSTEMS 1 5 SECTION PAGE Pretreatment Initial Phase Working Phase Final Phase Posttreatment Treatment time: 14 months, 2 weeks/7 treatment appointments 1 6 APPLIANCE SYSTEMS SECTION PAGE Damon System (cont.) Damon 3MX Extraordinary Strength • Stainless steel 17-4 metal-injection molded (MIM) construction for exceptional strength and durability • Four solid walls for fast, low-friction tooth movement and superior control • Remarkably easy-to-use slide mechanism with deep funnel and backstop for quick wire changes • Smooth slot corners for reduced binding even in severe deflections • Vertical slot for removable drop-in hooks and other auxiliaries • Contoured base design and Optimesh®XRT pads for optimal bond retention Bracket Identification • Ultra-smooth contours and rounded edges for maximum Permanent ID marking molded patient comfort in the base of the slot (International System) Damon 3MX Marking System Central Lateral Cuspid 1st Bicuspid 2nd Bicuspid Upper* Dark Blue Pink Green Purple Purple High Torque** Red Red Red Low Torque** Green Green Lower* Yellow Yellow Light Blue White Red High Torque** Red Low Torque** Green Green *IDdots are distogingival on all brackets including high and low torques. **IDdots are located on center of slide. Ormco • 800-854-1741 • 714-516-7400 • www.ormco.com
Description: