Anton Paar ProveTec Product Lines Master of Standards Testing Instruments for the Hydrocarbon World. ASTM D 5 | ASTM D 36 | ASTM D 56 | ASTM D 70 | ASTM D 86 | ASTM D 92 | ASTM D 93-A | ASTM D 93-B | ASTM D 93-C ASTM D 97 | ASTM D 113 | ASTM D 130 | ASTM D 189 | ASTM D 217 | ASTM D 287 | ASTM D 323 | ASTM D 381 ASTM D 445 ASTM D 446 | ASTM D 473 | ASTM D 524 | ASTM D 525 | ASTM D 665 | ASTM D 850 | ASTM D 873 ASTM D 892 ASTM D 937 ASTM D 942 | ASTM D 943 | ASTM D 1078 | ASTM D 1298 | ASTM D 1319 | ASTM D 1321 ASTM D 1401 | ASTM D 1403 | ASTM D 1481 | ASTM D 2111 | ASTM D 2170 | ASTM D 2274 | ASTM D 2500 | ASTM D 3142 | ASTM D 3230 | ASTM D 3603 | ASTM D 3934 | ASTM D 3941 | ASTM D 4310 | ASTM D 5534 | ASTM D 5853 | ASTM D 6082 | ASTM D 6084 | ASTM D 6184 | ASTM D 6371 | ASTM D 7462 | ASTM D 7525 | ASTM D 7545 | ASTM E 28 | DIN 51 551-1 | DIN 51 562 | DIN 51 579 | DIN 51 580 | DIN 51 587 | DIN 51 755-1 | DIN 51 757 | DIN 51 784 | DIN 51 794 | DIN 51 808 | DIN 51 817 | DIN 52 004 | DIN 52 013 | EN 116 | EN 924 | EN 1238 | EN 1426 | EN 1427 | EN 12 593 | EN 12 595 | EN 13 179-1 | EN 13 398 | EN 13 589 | EN 13 703 | EN 14 112 EN 14 522 | EN 15 751 | EN 16 091 | EN 23 015 | FTM 141-4293 | FTM 791-201 | FTM 791-305 | FTM 791-313 | FTM 791-321 FTM 791-1101 | FTM 791-1102 FTM 791-1103 | FTM 791-3002 | FTM 791-3302 | FTM 791-3352 | FTM 791-3354 | FTM 791- 3453 | FTM 791-3703 | FTM 791-4011 | FTM 791-5001 | FTM 791-5002 | FTM 791-5308 | FTM 791-5315 | FTM 791-5325 | IP 13 IP 14 | IP 15 | IP 34 | IP 36 | IP 40 | IP 49 | IP 50 | IP 53 | IP 58 | IP 69 | IP 71 | IP 80 | IP 121 | IP 123 | IP 131 | IP 135 | IP 138 | IP 142 | IP 146 | IP 154 | IP 156 | IP 157 | IP 160 | IP 170 | IP 179 | IP 189 | IP 190 | IP 195 | IP 219 | IP 265 | IP 309 | IP 310 | IP 319 | IP 376 | IP 388 | IP 441 | IP 491 | IP 492 | IP 515 | IP 516 | IP 520 | IP 540 | ISO 1516 | ISO 1523 | ISO 2137 | ISO 2592 | ISO 2719 | ISO 3007 | ISO 3015 | ISO 3016 | ISO 3104 | ISO 3105 | ISO 3405 | ISO 3675 | ISO 3735 | ISO 3837 | ISO 3838 | ISO 4262 | ISO 4263 | ISO 4625 | ISO 6246 | ISO 6247 | ISO 6614 | ISO 6615 | ISO 7120 | ISO 7536 | ISO 12 205 | ISO 13 736 | ISO 15 267 JIS C2101 | JIS K2207 | JIS K2220 | JIS K2235 | JIS K2249 | JIS K2254 | JIS K2258 | JIS K2261 | JIS K2265-1 | JIS K2265-3 JIS K2265-4 | JIS K2269 | JIS K2270 | JIS K2276 | JIS K2283 | JIS K2287 | JIS K2288 | JIS K2510 | JIS K2513 | JIS K2514 | JIS K2518 | JIS K2536 | JIS K2601 | AASHTO T48 | AASHTO T51 | AASHTO T53 | AASHTO T73 | AASHTO T172 | AASHTO T300 79/831/EWG | CEI 79-4 | DAB 10-V.5.8.1 | NAC TM0172-2001 | SMS 658 | Superpave® | VV-L-791e-5314 Anton Paar Headquarters Sales Subsidiaries Sales Partners and Joint Ventures Competence in AASHTO American Association of State Highway & Standardized Transportation Officials Measurement ASTM American Society for Testing & Materials DIN Deutsches Institut für Normung EN Comité Européen de Normalisation Index Volatility 4 - 7 ``Flammability 4 - 6 Testing Instruments for the Hydrocarbon World. ``Distillation 7 ASTM D 5 | ASTM D 36 | ASTM D 56 | ASTM D 70 | ASTM D 86 | ASTM D 92 | ASTM D 93-A | ASTM D 93-B | ASTM D 93-C ``Vapor Pressure 7 ASTM D 97 | ASTM D 113 | ASTM D 130 | ASTM D 189 | ASTM D 217 | ASTM D 287 | ASTM D 323 | ASTM D 381 ASTM D 445 ASTM D 446 | ASTM D 473 | ASTM D 524 | ASTM D 525 | ASTM D 665 | ASTM D 850 | ASTM D 873 ASTM D 892 ASTM D 937 ASTM D 942 | ASTM D 943 | ASTM D 1078 | ASTM D 1298 | ASTM D 1319 | ASTM D 1321 ASTM D 1401 | ASTM D 1403 | ASTM Oxidation Stability 8 - 9 D 1481 | ASTM D 2111 | ASTM D 2170 | ASTM D 2274 | ASTM D 2500 | ASTM D 3142 | ASTM D 3230 | ASTM D 3603 | ASTM D 3934 | ASTM D 3941 | ASTM D 4310 | ASTM D 5534 | ASTM D 5853 | ASTM D 6082 | ASTM D 6084 | ASTM D 6184 | ASTM D 6371 | ASTM D 7462 | ASTM D 7525 | ASTM D 7545 | ASTM E 28 | DIN 51 551-1 | DIN 51 562 | DIN 51 579 | DIN 51 580 | DIN Cold Flow Properties 10 51 587 | DIN 51 755-1 | DIN 51 757 | DIN 51 784 | DIN 51 794 | DIN 51 808 | DIN 51 817 | DIN 52 004 | DIN 52 013 | EN 116 | EN 924 | EN 1238 | EN 1426 | EN 1427 | EN 12 593 | EN 12 595 | EN 13 179-1 | EN 13 398 | EN 13 589 | EN 13 703 | EN 14 112 EN 14 522 | EN 15 751 | EN 16 091 | EN 23 015 | FTM 141-4293 | FTM 791-201 | FTM 791-305 | FTM 791-313 | FTM 791-321 Consistency & Ductility 11 - 13 FTM 791-1101 | FTM 791-1102 FTM 791-1103 | FTM 791-3002 | FTM 791-3302 | FTM 791-3352 | FTM 791-3354 | FTM 791- 3453 | FTM 791-3703 | FTM 791-4011 | FTM 791-5001 | FTM 791-5002 | FTM 791-5308 | FTM 791-5315 | FTM 791-5325 | IP 13 IP 14 | IP 15 | IP 34 | IP 36 | IP 40 | IP 49 | IP 50 | IP 53 | IP 58 | IP 69 | IP 71 | IP 80 | IP 121 | IP 123 | IP 131 | IP 135 | IP 138 Various Petroleum Properties 14 - 18 | IP 142 | IP 146 | IP 154 | IP 156 | IP 157 | IP 160 | IP 170 | IP 179 | IP 189 | IP 190 | IP 195 | IP 219 | IP 265 | IP 309 | IP 310 | IP 319 | IP 376 | IP 388 | IP 441 | IP 491 | IP 492 | IP 515 | IP 516 | IP 520 | IP 540 | ISO 1516 | ISO 1523 | ISO 2137 | ISO 2592 | ISO ``Liquids 14 2719 | ISO 3007 | ISO 3015 | ISO 3016 | ISO 3104 | ISO 3105 | ISO 3405 | ISO 3675 | ISO 3735 | ISO 3837 | ISO 3838 | ISO 4262 ``Fuels 14 - 16 | ISO 4263 | ISO 4625 | ISO 6246 | ISO 6247 | ISO 6614 | ISO 6615 | ISO 7120 | ISO 7536 | ISO 12 205 | ISO 13 736 | ISO 15 267 JIS C2101 | JIS K2207 | JIS K2220 | JIS K2235 | JIS K2249 | JIS K2254 | JIS K2258 | JIS K2261 | JIS K2265-1 | JIS K2265-3 ``Lubricants 17 - 18 JIS K2265-4 | JIS K2269 | JIS K2270 | JIS K2276 | JIS K2283 | JIS K2287 | JIS K2288 | JIS K2510 | JIS K2513 | JIS K2514 | JIS ``Greases 18 K2518 | JIS K2536 | JIS K2601 | AASHTO T48 | AASHTO T51 | AASHTO T53 | AASHTO T73 | AASHTO T172 | AASHTO T300 79/831/EWG | CEI 79-4 | DAB 10-V.5.8.1 | NAC TM0172-2001 | SMS 658 | Superpave® | VV-L-791e-5314 Accessories 19 AASHTO American Association of State Highway & FTM Federal Test Method (US) Transportation Officials IEC International Electrotechnical Commission ASTM American Society for Testing & Materials IP Institute of Petroleum Standards DIN Deutsches Institut für Normung ISO International Standardization Organisation EN Comité Européen de Normalisation JIS Japanese Industrial Standards Committee Volatility - Flammability Pensky-Martens Flash Point Tester: PMA 5 Specifications The automatic closed cup flash point tester Datasheet: PMA 5 detects the flash point at the lowest 12-5770.pdf (PMA 5) temperature corrected to a barometric pressure of 101.3 kPa at which application Reference: of an ignition source causes the vapors 12-5770 / 107125 (115/230 V, EU) of a specimen of a sample to ignite under 12-5771 / 107126 (115/230 V, US) specified conditions of test. Suitable for biodiesel (FAME) & blends, Temperature range: distillate fuels (diesel, kerosine, heating ambient to +405 °C (+761 °F) oil, turbine fuels), lubricating oils and other homogeneous petroleum liquids. Standard methods: ASTM D 93-A+B+C, ISO 2719-A+B+C, JIS K2265-3, IP 34-A+B+C Pensky-Martens Flash Point Tester with Sample Changer: PMA 4 SC Datasheet: PMA 4 SC is an exceptionally time and 12-2772.pdf (PMA 4 SC) cost saving alternative. The PMA 4 with sample changer carrousel can carrying up Reference: to 12 test cups. 12-2772 / 107121 (115/230 V, EU) The instrument is equipped with a fire 12-2773 / 108322 (115/230 V, US) extinguishing system. It is still small enough to fit into a fume-hood. Temperature range: ambient to +405 °C (+761 °F) Standard methods: ASTM D 93-A+B+C, ISO 2719-A+B+C, JIS K2265-3, IP 34-A+B+C Cleveland Flash & Fire Point Tester: CLA 5 The automatic open cup flash & fire point Datasheet: tester CLA 5 measures the flash point and 12-5700.pdf (CLA 5) fire point of petroleum products. It is applicable to all petroleum products Reference: with flash point above 79 °C (175 °F) and 12-5700 / 107122 (115/230 V, EU) below 400 °C (752 °F) including bitumen. 12-5701 / 107123 (115/230 V, US) Except fuel oils. Temperature range: Standard methods: +79 °C to +400 °C (+175 to +752 °F) ASTM D 92, ISO 2592, EN 22592, JIS K2265-4, AASHTO T48, FTM 791-1103, IP 36 4 Volatility - Flammability Abel Flash Point Tester: Specifications ABA 4 Datasheet: The automatic closed cup flash point 12-0501.pdf (ABA 4) tester ABA 4 measures the flash point of petroleum liquid products and other liquids Reference: internal air cooling having flash points between -30 °C and 12-0501 / 107097 (115/230 V, EU) +110 °C. 12-0502 / 108319 (115/230 V, US) The equilibrium-method measures the Reference: external liquid cooling flash/no flash temperature of paints, 12-0503 / 107098 (115/230 V, EU) varnishes, paint binders, solvents, 12-0504 / 108320 (115/230 V, US) adhesives, petroleum & related products between -30 °C and +110 °C. Temp. range: internal air cooling +10 °C to +110 °C (+50 to +230 °F) Standard methods: Temp. range: external liquid cooling ISO 13 736, ISO 1516, ISO 1523, EN 924, -30 °C to +110 °C (-22 to +230 °F) DIN 51 755-1, IP 170, IP 491, IP 492 TAG Flash Point Tester: TAG 4 The automatic closed cup flash point Datasheet: tester TAG 4 measures the flash point of 12-0540.pdf (TAG 4) petroleum liquids and other liquids having flash points between -30 °C and +110 °C. Reference: internal air cooling Suitable for kerosine, jet fuel, solvent, 12-0540 / 107099 (115/230 V, EU) chemicals. 12-0541 / 107100 (115/230 V, US) Reference: external liquid cooling Standard methods: 12-0542 / 107101 (115/230 V, EU) ASTM D 56, ASTM D 3934, ASTM D 3941, 12-0543 / 108321 (115/230 V, US) ISO 1516, ISO 1523, EN 924, JIS K2265-1, FTM 791-1101, IP 304, IP 491, IP 492 Temp. range: internal air cooling 0 °C to +110 °C (+32 to +230 °F) Temp. range: external liquid cooling -30 °C to +110 °C (-22 to +230 °F) Pensky-Martens Flash Point Tester: PM 4 Datasheet: The semi-automatic closed cup flash point 12-1650.pdf (PM 4) tester PM 4 measures the flash point at the lowest temperature at which application Reference: of an ignition source causes the vapors 12-1650 / 107149 (230 V) of a specimen of a sample to ignite under 12-1651 / 107150 (115 V) specified conditions of test. Temperature range: Standard methods: +40 °C to +350 °C (+104 to +662 °F) ASTM D 93-A+B, ISO 15 267, ISO 2719-A+B, JIS K2265-3, AASHTO T73, AASHTO T172, FTM 141-4293, FTM 791-1102, IP 34-A+B 5 Volatility - Flammability Cleveland Flash & Fire Point Tester: CL 5 Specifications The semi-automatic open cup flash and Datasheet: fire point tester CL 5 can measure the 12-2730.pdf (CL 5) flash and fire point acc. to the Cleveland method. It is suitable for petroleum Reference: products and other liquids including 12-2730 / 107152 (230 V) bitumen with an expected flash & fire point 12-2731 / 107153 (115 V) in the range of +79 °C to +400 °C (+175 °F to +752 °F). Temperature range: +79 °C to +400 °C (+175 to +752 °F) Standard methods: ASTM D 92, ISO 2592, JIS K2265-4, AASHTO T48, FTM 791-1103, IP 36 Abel Flash Point Tester: AB 5 Datasheet: The semi-automatic closed cup flash point 12-2270.pdf (AB 5) tester AB 5 can measure the flash point of petroleum products and other liquids with Reference: flash points up to +70 °C (up to +158 °F). 12-2270 / 107151 (230 V) Standard methods: Measuring range: ISO 13 736, IP 170 up to +70 °C (up to +158 °F) Auto-Ignition Temperature Tester: ZPA 3 The ZPA 3 enables automatically a Datasheet: classification to safety aspects by 12-1822.pdf (ZPA 3) measuring the tendency of substances to ignite themselves when getting contact Reference: with sample-feeder with hot objects. 12-1822 / 107115 (230 V) Suitable for liquids. A special program 12-1823 / 110237 (115 V) allows to examine pasty or solid matter, too. Reference: without sample-feeder Available with or without heated sample- 12-1800 / 130641 (230 V) feeding device. 12-1801 / 130642 (115 V) Standard methods: Temperature range: EN 14 522, EN 60 079, CEI 79-4, DIN 51 794, ambient to +650 °C (+1202 °F) IEC 60079, VDE 0170, 79/831/EWG 6 Volatility - Distillation & Vapor Pressure Distillation at Atmospheric Specifications Pressure: ADU 4+ Datasheet: The ADU 4+ automatically performs 11-5580.pdf (ADU 4+) distillation tests of petroleum products as well as aromatic hydrocarbons and Reference: other volatile organic liquids featuring an 11-5580 / 106515 (230 V) automated fire extinguishing system. 11-5582 / 106516 (230V, Dry Point) Options: Working range: ADU 4+ Dry Point with automatic dry point 0 °C to +450 °C (+32 °F to +842 °F) detection. Distillation groups: Standard methods: 1 to 4, solvents ASTM D 86, ASTM D 850, ASTM D 1078, ISO 3405, JIS K2254, IP 123, IP 195 Distillation at Atmospheric Pressure: DU 4 Eco & Pro For the manual distillation of petroleum Datasheet: products as well as aromatic hydrocarbons 11-0904.pdf (DU 4 Eco) and other volatile organic liquids. 11-0910.pdf (DU 4 Pro) Options: Reference: ``DU 4 EcoPlus 11-0904 / 106509 (230 V, Eco+) ``DU 4 EcoThermoPlus 11-0905 / 108315 (115 V, Eco+) ``DU 4 Pro 11-0906 / 106510 (230 V, EcoThermo+) ``DU 4 ProThermo 11-0907 / 106511 (115 V, EcoThermo+) 11-0910 / 106512 (230 V, Pro) Standard methods: 11-0911 / 106513 (115 V, Pro) ASTM D 86, ASTM D 850, ASTM D 1078, 11-0912 / 106514 (230 V, ProThermo) ISO 3405, JIS K2254, IP 123, IP 195 11-0913 / 108316 (115 V, ProThermo) Distillation groups: 1 to 4, solvents (up to 400 °C) REID Vapor Pressure: RVP Datasheet: The RVP is used for the determination of 13-0201_digital.pdf (RVP) vapor pressure of gasoline, volatile crude 13-0201_analog.pdf (RVP) oil and other volatile petroleum products. It is a modular system to be composed of Reference: RElD-Vapor Pressure Vessels (with 2 valves 13-0201 / 107034 (vessel <180 bar) or valveless), analog or digital PA-REID 13-0202 / 107035 (vessel >180 bar) manometers and a liquid bath. 13-2250 / 107021 (manometer) 17-0210 / 106583 (230 V, 6-place bath) Standard methods: 13-0215 / 106542 (230 V, 3-place bath) ASTM D 323-A+C+D, ISO 3007-A+C+D, JIS K2258, IP 69-A+C+D Temperature range: +79 °C to +400 °C (+175 to +752 °F) 7 Oxidation Stability Rapid Small Scale Oxidation Test (RSSOT): PetroOxy Specifications The automatic PetroOxy initiates a very Datasheet: fast artificial aging process to evaluate the 13-3002.pdf (PetroOxy Block) oxidation stability of liquid fuels (gasoline, 13-3006.pdf (PetroOxy Peltier) diesel, biodiesel/FAME & blends). The results include all volatile & non-volatile Reference: oxidation products, thereby provide 13-3002 / 107131 (115/230 V, EU) a complete analysis of the sample's 13-3003 / 107132 (115/230 V, US) oxidation stability in a short time period. Reference: Active Cool Standard methods: 13-3006 / 107133 (115/230 V, EU, Peltier) ASTM D 7525 (Gasoline) 13-3007 / 107134 (115/230 V, US, Peltier) ASTM D 7545 (Diesel, Biodiesel & Blends) EN 16 091 (Diesel, Biodiesel (FAME) & Blends) Rapid Small Scale Oxidation Test (RSSOT): PetroOxy Steel Datasheet: The automatic PetroOxy with stainless 13-3008.pdf (PetroOxy S Block) steel chamber initiates a very fast artificial 13-3016.pdf (PetroOxy S Peltier) aging process to evaluate the oxidation stability of natural oils/fats, food & Reference: cosmetics and water containing products. 13-3008 / 107135 (115/230 V, EU) The PetroOxy is cost saving due to a 13-3009 / 107136 (115/230 V, US) massive reduction of test time, improved repeatability and small sample volumen. Reference: Active Cool The PetroOxy requires manual re-cooling 13-3016 / 108338 (115/230 V, EU, Peltier) between tests by an externally chilled 13-3017 / 108339 (115/230 V, US, Peltier) cooling block. While the PetroOxy Active Cool with Peltier elements will re-cool automatically. Especially recommended for low boiling liquids. Oxidation Stability of Gasoline and Aviation Fuels: OBA 1 The semi-automatic OBA 1 is used for fuels Datasheet: to determine the stability (induction period) 13-1660.pdf (OBA 1) and the tendency to form gum (potential residue) under accelerated oxidation Reference: OBA 1 conditions. 13-1660 / 107052 (230 V, liquid) Programmable PA 5-OBA manometers on 13-1661 / 107053 (115 V, liquid) stainless steel oxidation vessels are available in combination with a liquid bath as OBA 1 Reference: OBA 1/T or as OBA 1/T with a dry heat bath. 13-1662 / 107054 (230 V, dry heat) 13-1663 / 107055 (115 V, dry heat) Standard methods: ASTM D 525, ASTM D 873, ISO 7536, Test places: JIS K2276, JIS K2287, FTM 791-3352, 1 - 4 FTM 791-3354, IP 40, IP 138 8 Oxidation Stability Oxidation Stability of Gasoline and Specifications Aviation Fuels: OBA 2 Datasheet: The semi-automatic OBA 2 safety arrange- 13-1664.pdf (OBA 2) ment has special features to comply with German safety regulations to avoid health- Reference: OBA 2 hazards caused by unexpected explosions 13-1664 / 108333 (230 V, liquid) as much as possible and also protect the 13-1665 / 108334 (115 V, liquid) expensive pressure sensors. The programmable PA 5-OBA manometers Reference: OBA 2/T on the stainless steel oxidation vessels are 13-1666 / 107056 (230 V, dry heat) available with a liquid bath as OBA 2 or as 13-1667 / 108335 (115 V, dry heat) OBA 2/T with a dry heat bath. Test places: Standard methods: 1 - 4 ASTM D 525, ASTM D 873, ISO 7536, JIS K2276, JIS K2287, FTM 791-3352, FTM 791-3354, IP 40, IP 138 Oxidation Characteristics: TOST/TOO The modular TOST liquid bath is used for Datasheets: testing the oxidation characteristics of 16-0586_ASTM943.pdf (TOST) various petroleum products. 16-0586_ASTM2274.pdf (TOST) Standardized glassware sets and 16-0586_ASTM4310.pdf (TOST) accessories are available. 16-0586_ISO4263.pdf (TOST) 16-0586_ISO12205.pdf (TOST) Standard methods: 16-0586_DIN51587.pdf (TOST) ASTM D 943, ASTM D 2274, ASTM D 4310, 16-0545.pdf (TOO) ASTM D 7462, ISO 12 205, ISO 4263-1, ISO 4263-2, ISO 4263-3, JIS C2101, Reference: JIS K2514, DIN 51 587, FTM 791-5308, IP 157, 16-0583 / 106563 (230 V) IP 388 16-0584 / 106564 (115 V) Test places: 1 - 4 Oxidation Stability of Lubricating Greases: OFA 2 Datasheet: The semi-automatic OFA 2 arrangement 17-0212.pdf (OFA 2) may be used for quality control to indicate batch-to-batch conformity of lubricating Reference: greases stored in an oxygen atmosphere 17-0212 / 107088 (oxidation vessel) in a sealed system at an elevated 17-1210 / 107030 (manometer) temperature. 17-0210 / 106583 (230 V, liquid bath) The programmable PA 5-OFA manometer 13-1672 / 106555 (230 V, dry heat bath) shall be combined with the stainless steel oxidation vessel and a liquid bath or dry Test places: heat bath. 1 - 4 Standard methods: ASTM D 942, JIS K2220, DIN 51 808, FTM 791-3453, IP 142, VV-L-791e-5314 9 Cold Flow Properties Cold Filter Plugging Point: CFPP I Specifications The cold filter plugging point test Datasheet: determinates the lowest temperature at 13-2418.pdf (CFPP I) which a fuel will give trouble free flow in certain fuel systems. It is defined as Reference: highest temperature at which a given 13-2418 / 107162 (230 V) volume of fuel fails to pass through a standardized filtration device in a specified Working range: time when cooled under the conditions down to -34 °C prescribed in the test method. A system of a metal-block cryostat with Test places: a 4-place cooling chamber provides the 1 chamber (4 places) required cooling temperature. Standard methods: ASTM D 6371, EN 116, JIS K2288, IP 309 Cloud & Pour Point: CAPP I Datasheet: The CAPP I is a metal-block cryostat 16-2372.pdf (CAPP I) designed to perform the cloud point test. It is the temperature at which a fuel starts Reference: becoming cloudy or begins to precipitate 16-2372 / 106533 (230 V, 1 bath) paraffin. The pour point is the lowest temperature at which movement of the test Working range: sample is observed. +20 °C to -69 °C Suitable for any petroleum products. Chamber temperatures: Standard methods: 0 °C to -69 °C ASTM D 97, ASTM D 2500, ASTM D 5853, ISO 3015, ISO 3016, EN 23 015, JIS K2269, Test places: JIS K2601, FTM 791-201, IP 15, IP 219, IP 441 1 chamber (4 places) Cloud & Pour Point: Datasheet: CAPP IV & V 16-2378.pdf (CAPP IV) 16-2360.pdf (CAPP V) Designed for an easy workflow, the CAPP IV & V with independently set Reference: of cooling chambers allows an instant 16-2378 / 107029 (230 V, 4 bath) transfer of the sample jar to the next lower 16-2360 / 106532 (230 V, 5 bath) chamber temperature. Suitable for any petroleum products. Working range: +20 °C to -69 °C Standard methods: ASTM D 97, ASTM D 2500, ASTM D 5853, Chamber temperatures: ISO 3015, ISO 3016, EN 23 015, JIS K2269, 0 °C, -18 °C, -33 °C, -51 °C, -69 °C JIS K2601, FTM 791-201, IP 15, IP 219, IP 441 Test places: 4 or 5 chambers (4 places each) 10
Description: