ebook img

Anton Paar ProveTec Product Lines PDF

24 Pages·2013·3.57 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Anton Paar ProveTec Product Lines

Anton Paar ProveTec Product Lines Master of Standards Testing Instruments for the Hydrocarbon World. ASTM D 5 | ASTM D 36 | ASTM D 56 | ASTM D 70 | ASTM D 86 | ASTM D 92 | ASTM D 93-A | ASTM D 93-B | ASTM D 93-C ASTM D 97 | ASTM D 113 | ASTM D 130 | ASTM D 189 | ASTM D 217 | ASTM D 287 | ASTM D 323 | ASTM D 381 ASTM D 445 ASTM D 446 | ASTM D 473 | ASTM D 524 | ASTM D 525 | ASTM D 665 | ASTM D 850 | ASTM D 873 ASTM D 892 ASTM D 937 ASTM D 942 | ASTM D 943 | ASTM D 1078 | ASTM D 1298 | ASTM D 1319 | ASTM D 1321 ASTM D 1401 | ASTM D 1403 | ASTM D 1481 | ASTM D 2111 | ASTM D 2170 | ASTM D 2274 | ASTM D 2500 | ASTM D 3142 | ASTM D 3230 | ASTM D 3603 | ASTM D 3934 | ASTM D 3941 | ASTM D 4310 | ASTM D 5534 | ASTM D 5853 | ASTM D 6082 | ASTM D 6084 | ASTM D 6184 | ASTM D 6371 | ASTM D 7462 | ASTM D 7525 | ASTM D 7545 | ASTM E 28 | DIN 51 551-1 | DIN 51 562 | DIN 51 579 | DIN 51 580 | DIN 51 587 | DIN 51 755-1 | DIN 51 757 | DIN 51 784 | DIN 51 794 | DIN 51 808 | DIN 51 817 | DIN 52 004 | DIN 52 013 | EN 116 | EN 924 | EN 1238 | EN 1426 | EN 1427 | EN 12 593 | EN 12 595 | EN 13 179-1 | EN 13 398 | EN 13 589 | EN 13 703 | EN 14 112 EN 14 522 | EN 15 751 | EN 16 091 | EN 23 015 | FTM 141-4293 | FTM 791-201 | FTM 791-305 | FTM 791-313 | FTM 791-321 FTM 791-1101 | FTM 791-1102 FTM 791-1103 | FTM 791-3002 | FTM 791-3302 | FTM 791-3352 | FTM 791-3354 | FTM 791- 3453 | FTM 791-3703 | FTM 791-4011 | FTM 791-5001 | FTM 791-5002 | FTM 791-5308 | FTM 791-5315 | FTM 791-5325 | IP 13 IP 14 | IP 15 | IP 34 | IP 36 | IP 40 | IP 49 | IP 50 | IP 53 | IP 58 | IP 69 | IP 71 | IP 80 | IP 121 | IP 123 | IP 131 | IP 135 | IP 138 | IP 142 | IP 146 | IP 154 | IP 156 | IP 157 | IP 160 | IP 170 | IP 179 | IP 189 | IP 190 | IP 195 | IP 219 | IP 265 | IP 309 | IP 310 | IP 319 | IP 376 | IP 388 | IP 441 | IP 491 | IP 492 | IP 515 | IP 516 | IP 520 | IP 540 | ISO 1516 | ISO 1523 | ISO 2137 | ISO 2592 | ISO 2719 | ISO 3007 | ISO 3015 | ISO 3016 | ISO 3104 | ISO 3105 | ISO 3405 | ISO 3675 | ISO 3735 | ISO 3837 | ISO 3838 | ISO 4262 | ISO 4263 | ISO 4625 | ISO 6246 | ISO 6247 | ISO 6614 | ISO 6615 | ISO 7120 | ISO 7536 | ISO 12 205 | ISO 13 736 | ISO 15 267 JIS C2101 | JIS K2207 | JIS K2220 | JIS K2235 | JIS K2249 | JIS K2254 | JIS K2258 | JIS K2261 | JIS K2265-1 | JIS K2265-3 JIS K2265-4 | JIS K2269 | JIS K2270 | JIS K2276 | JIS K2283 | JIS K2287 | JIS K2288 | JIS K2510 | JIS K2513 | JIS K2514 | JIS K2518 | JIS K2536 | JIS K2601 | AASHTO T48 | AASHTO T51 | AASHTO T53 | AASHTO T73 | AASHTO T172 | AASHTO T300 79/831/EWG | CEI 79-4 | DAB 10-V.5.8.1 | NAC TM0172-2001 | SMS 658 | Superpave® | VV-L-791e-5314 Anton Paar Headquarters Sales Subsidiaries Sales Partners and Joint Ventures Competence in AASHTO American Association of State Highway & Standardized Transportation Officials Measurement ASTM American Society for Testing & Materials DIN Deutsches Institut für Normung EN Comité Européen de Normalisation Index Volatility 4 - 7 ``Flammability 4 - 6 Testing Instruments for the Hydrocarbon World. ``Distillation 7 ASTM D 5 | ASTM D 36 | ASTM D 56 | ASTM D 70 | ASTM D 86 | ASTM D 92 | ASTM D 93-A | ASTM D 93-B | ASTM D 93-C ``Vapor Pressure 7 ASTM D 97 | ASTM D 113 | ASTM D 130 | ASTM D 189 | ASTM D 217 | ASTM D 287 | ASTM D 323 | ASTM D 381 ASTM D 445 ASTM D 446 | ASTM D 473 | ASTM D 524 | ASTM D 525 | ASTM D 665 | ASTM D 850 | ASTM D 873 ASTM D 892 ASTM D 937 ASTM D 942 | ASTM D 943 | ASTM D 1078 | ASTM D 1298 | ASTM D 1319 | ASTM D 1321 ASTM D 1401 | ASTM D 1403 | ASTM Oxidation Stability 8 - 9 D 1481 | ASTM D 2111 | ASTM D 2170 | ASTM D 2274 | ASTM D 2500 | ASTM D 3142 | ASTM D 3230 | ASTM D 3603 | ASTM D 3934 | ASTM D 3941 | ASTM D 4310 | ASTM D 5534 | ASTM D 5853 | ASTM D 6082 | ASTM D 6084 | ASTM D 6184 | ASTM D 6371 | ASTM D 7462 | ASTM D 7525 | ASTM D 7545 | ASTM E 28 | DIN 51 551-1 | DIN 51 562 | DIN 51 579 | DIN 51 580 | DIN Cold Flow Properties 10 51 587 | DIN 51 755-1 | DIN 51 757 | DIN 51 784 | DIN 51 794 | DIN 51 808 | DIN 51 817 | DIN 52 004 | DIN 52 013 | EN 116 | EN 924 | EN 1238 | EN 1426 | EN 1427 | EN 12 593 | EN 12 595 | EN 13 179-1 | EN 13 398 | EN 13 589 | EN 13 703 | EN 14 112 EN 14 522 | EN 15 751 | EN 16 091 | EN 23 015 | FTM 141-4293 | FTM 791-201 | FTM 791-305 | FTM 791-313 | FTM 791-321 Consistency & Ductility 11 - 13 FTM 791-1101 | FTM 791-1102 FTM 791-1103 | FTM 791-3002 | FTM 791-3302 | FTM 791-3352 | FTM 791-3354 | FTM 791- 3453 | FTM 791-3703 | FTM 791-4011 | FTM 791-5001 | FTM 791-5002 | FTM 791-5308 | FTM 791-5315 | FTM 791-5325 | IP 13 IP 14 | IP 15 | IP 34 | IP 36 | IP 40 | IP 49 | IP 50 | IP 53 | IP 58 | IP 69 | IP 71 | IP 80 | IP 121 | IP 123 | IP 131 | IP 135 | IP 138 Various Petroleum Properties 14 - 18 | IP 142 | IP 146 | IP 154 | IP 156 | IP 157 | IP 160 | IP 170 | IP 179 | IP 189 | IP 190 | IP 195 | IP 219 | IP 265 | IP 309 | IP 310 | IP 319 | IP 376 | IP 388 | IP 441 | IP 491 | IP 492 | IP 515 | IP 516 | IP 520 | IP 540 | ISO 1516 | ISO 1523 | ISO 2137 | ISO 2592 | ISO ``Liquids 14 2719 | ISO 3007 | ISO 3015 | ISO 3016 | ISO 3104 | ISO 3105 | ISO 3405 | ISO 3675 | ISO 3735 | ISO 3837 | ISO 3838 | ISO 4262 ``Fuels 14 - 16 | ISO 4263 | ISO 4625 | ISO 6246 | ISO 6247 | ISO 6614 | ISO 6615 | ISO 7120 | ISO 7536 | ISO 12 205 | ISO 13 736 | ISO 15 267 JIS C2101 | JIS K2207 | JIS K2220 | JIS K2235 | JIS K2249 | JIS K2254 | JIS K2258 | JIS K2261 | JIS K2265-1 | JIS K2265-3 ``Lubricants 17 - 18 JIS K2265-4 | JIS K2269 | JIS K2270 | JIS K2276 | JIS K2283 | JIS K2287 | JIS K2288 | JIS K2510 | JIS K2513 | JIS K2514 | JIS ``Greases 18 K2518 | JIS K2536 | JIS K2601 | AASHTO T48 | AASHTO T51 | AASHTO T53 | AASHTO T73 | AASHTO T172 | AASHTO T300 79/831/EWG | CEI 79-4 | DAB 10-V.5.8.1 | NAC TM0172-2001 | SMS 658 | Superpave® | VV-L-791e-5314 Accessories 19 AASHTO American Association of State Highway & FTM Federal Test Method (US) Transportation Officials IEC International Electrotechnical Commission ASTM American Society for Testing & Materials IP Institute of Petroleum Standards DIN Deutsches Institut für Normung ISO International Standardization Organisation EN Comité Européen de Normalisation JIS Japanese Industrial Standards Committee Volatility - Flammability Pensky-Martens Flash Point Tester: PMA 5 Specifications The automatic closed cup flash point tester Datasheet: PMA 5 detects the flash point at the lowest 12-5770.pdf (PMA 5) temperature corrected to a barometric pressure of 101.3 kPa at which application Reference: of an ignition source causes the vapors 12-5770 / 107125 (115/230 V, EU) of a specimen of a sample to ignite under 12-5771 / 107126 (115/230 V, US) specified conditions of test. Suitable for biodiesel (FAME) & blends, Temperature range: distillate fuels (diesel, kerosine, heating ambient to +405 °C (+761 °F) oil, turbine fuels), lubricating oils and other homogeneous petroleum liquids. Standard methods: ASTM D 93-A+B+C, ISO 2719-A+B+C, JIS K2265-3, IP 34-A+B+C Pensky-Martens Flash Point Tester with Sample Changer: PMA 4 SC Datasheet: PMA 4 SC is an exceptionally time and 12-2772.pdf (PMA 4 SC) cost saving alternative. The PMA 4 with sample changer carrousel can carrying up Reference: to 12 test cups. 12-2772 / 107121 (115/230 V, EU) The instrument is equipped with a fire 12-2773 / 108322 (115/230 V, US) extinguishing system. It is still small enough to fit into a fume-hood. Temperature range: ambient to +405 °C (+761 °F) Standard methods: ASTM D 93-A+B+C, ISO 2719-A+B+C, JIS K2265-3, IP 34-A+B+C Cleveland Flash & Fire Point Tester: CLA 5 The automatic open cup flash & fire point Datasheet: tester CLA 5 measures the flash point and 12-5700.pdf (CLA 5) fire point of petroleum products. It is applicable to all petroleum products Reference: with flash point above 79 °C (175 °F) and 12-5700 / 107122 (115/230 V, EU) below 400 °C (752 °F) including bitumen. 12-5701 / 107123 (115/230 V, US) Except fuel oils. Temperature range: Standard methods: +79 °C to +400 °C (+175 to +752 °F) ASTM D 92, ISO 2592, EN 22592, JIS K2265-4, AASHTO T48, FTM 791-1103, IP 36 4 Volatility - Flammability Abel Flash Point Tester: Specifications ABA 4 Datasheet: The automatic closed cup flash point 12-0501.pdf (ABA 4) tester ABA 4 measures the flash point of petroleum liquid products and other liquids Reference: internal air cooling having flash points between -30 °C and 12-0501 / 107097 (115/230 V, EU) +110 °C. 12-0502 / 108319 (115/230 V, US) The equilibrium-method measures the Reference: external liquid cooling flash/no flash temperature of paints, 12-0503 / 107098 (115/230 V, EU) varnishes, paint binders, solvents, 12-0504 / 108320 (115/230 V, US) adhesives, petroleum & related products between -30 °C and +110 °C. Temp. range: internal air cooling +10 °C to +110 °C (+50 to +230 °F) Standard methods: Temp. range: external liquid cooling ISO 13 736, ISO 1516, ISO 1523, EN 924, -30 °C to +110 °C (-22 to +230 °F) DIN 51 755-1, IP 170, IP 491, IP 492 TAG Flash Point Tester: TAG 4 The automatic closed cup flash point Datasheet: tester TAG 4 measures the flash point of 12-0540.pdf (TAG 4) petroleum liquids and other liquids having flash points between -30 °C and +110 °C. Reference: internal air cooling Suitable for kerosine, jet fuel, solvent, 12-0540 / 107099 (115/230 V, EU) chemicals. 12-0541 / 107100 (115/230 V, US) Reference: external liquid cooling Standard methods: 12-0542 / 107101 (115/230 V, EU) ASTM D 56, ASTM D 3934, ASTM D 3941, 12-0543 / 108321 (115/230 V, US) ISO 1516, ISO 1523, EN 924, JIS K2265-1, FTM 791-1101, IP 304, IP 491, IP 492 Temp. range: internal air cooling 0 °C to +110 °C (+32 to +230 °F) Temp. range: external liquid cooling -30 °C to +110 °C (-22 to +230 °F) Pensky-Martens Flash Point Tester: PM 4 Datasheet: The semi-automatic closed cup flash point 12-1650.pdf (PM 4) tester PM 4 measures the flash point at the lowest temperature at which application Reference: of an ignition source causes the vapors 12-1650 / 107149 (230 V) of a specimen of a sample to ignite under 12-1651 / 107150 (115 V) specified conditions of test. Temperature range: Standard methods: +40 °C to +350 °C (+104 to +662 °F) ASTM D 93-A+B, ISO 15 267, ISO 2719-A+B, JIS K2265-3, AASHTO T73, AASHTO T172, FTM 141-4293, FTM 791-1102, IP 34-A+B 5 Volatility - Flammability Cleveland Flash & Fire Point Tester: CL 5 Specifications The semi-automatic open cup flash and Datasheet: fire point tester CL 5 can measure the 12-2730.pdf (CL 5) flash and fire point acc. to the Cleveland method. It is suitable for petroleum Reference: products and other liquids including 12-2730 / 107152 (230 V) bitumen with an expected flash & fire point 12-2731 / 107153 (115 V) in the range of +79 °C to +400 °C (+175 °F to +752 °F). Temperature range: +79 °C to +400 °C (+175 to +752 °F) Standard methods: ASTM D 92, ISO 2592, JIS K2265-4, AASHTO T48, FTM 791-1103, IP 36 Abel Flash Point Tester: AB 5 Datasheet: The semi-automatic closed cup flash point 12-2270.pdf (AB 5) tester AB 5 can measure the flash point of petroleum products and other liquids with Reference: flash points up to +70 °C (up to +158 °F). 12-2270 / 107151 (230 V) Standard methods: Measuring range: ISO 13 736, IP 170 up to +70 °C (up to +158 °F) Auto-Ignition Temperature Tester: ZPA 3 The ZPA 3 enables automatically a Datasheet: classification to safety aspects by 12-1822.pdf (ZPA 3) measuring the tendency of substances to ignite themselves when getting contact Reference: with sample-feeder with hot objects. 12-1822 / 107115 (230 V) Suitable for liquids. A special program 12-1823 / 110237 (115 V) allows to examine pasty or solid matter, too. Reference: without sample-feeder Available with or without heated sample- 12-1800 / 130641 (230 V) feeding device. 12-1801 / 130642 (115 V) Standard methods: Temperature range: EN 14 522, EN 60 079, CEI 79-4, DIN 51 794, ambient to +650 °C (+1202 °F) IEC 60079, VDE 0170, 79/831/EWG 6 Volatility - Distillation & Vapor Pressure Distillation at Atmospheric Specifications Pressure: ADU 4+ Datasheet: The ADU 4+ automatically performs 11-5580.pdf (ADU 4+) distillation tests of petroleum products as well as aromatic hydrocarbons and Reference: other volatile organic liquids featuring an 11-5580 / 106515 (230 V) automated fire extinguishing system. 11-5582 / 106516 (230V, Dry Point) Options: Working range: ADU 4+ Dry Point with automatic dry point 0 °C to +450 °C (+32 °F to +842 °F) detection. Distillation groups: Standard methods: 1 to 4, solvents ASTM D 86, ASTM D 850, ASTM D 1078, ISO 3405, JIS K2254, IP 123, IP 195 Distillation at Atmospheric Pressure: DU 4 Eco & Pro For the manual distillation of petroleum Datasheet: products as well as aromatic hydrocarbons 11-0904.pdf (DU 4 Eco) and other volatile organic liquids. 11-0910.pdf (DU 4 Pro) Options: Reference: ``DU 4 EcoPlus 11-0904 / 106509 (230 V, Eco+) ``DU 4 EcoThermoPlus 11-0905 / 108315 (115 V, Eco+) ``DU 4 Pro 11-0906 / 106510 (230 V, EcoThermo+) ``DU 4 ProThermo 11-0907 / 106511 (115 V, EcoThermo+) 11-0910 / 106512 (230 V, Pro) Standard methods: 11-0911 / 106513 (115 V, Pro) ASTM D 86, ASTM D 850, ASTM D 1078, 11-0912 / 106514 (230 V, ProThermo) ISO 3405, JIS K2254, IP 123, IP 195 11-0913 / 108316 (115 V, ProThermo) Distillation groups: 1 to 4, solvents (up to 400 °C) REID Vapor Pressure: RVP Datasheet: The RVP is used for the determination of 13-0201_digital.pdf (RVP) vapor pressure of gasoline, volatile crude 13-0201_analog.pdf (RVP) oil and other volatile petroleum products. It is a modular system to be composed of Reference: RElD-Vapor Pressure Vessels (with 2 valves 13-0201 / 107034 (vessel <180 bar) or valveless), analog or digital PA-REID 13-0202 / 107035 (vessel >180 bar) manometers and a liquid bath. 13-2250 / 107021 (manometer) 17-0210 / 106583 (230 V, 6-place bath) Standard methods: 13-0215 / 106542 (230 V, 3-place bath) ASTM D 323-A+C+D, ISO 3007-A+C+D, JIS K2258, IP 69-A+C+D Temperature range: +79 °C to +400 °C (+175 to +752 °F) 7 Oxidation Stability Rapid Small Scale Oxidation Test (RSSOT): PetroOxy Specifications The automatic PetroOxy initiates a very Datasheet: fast artificial aging process to evaluate the 13-3002.pdf (PetroOxy Block) oxidation stability of liquid fuels (gasoline, 13-3006.pdf (PetroOxy Peltier) diesel, biodiesel/FAME & blends). The results include all volatile & non-volatile Reference: oxidation products, thereby provide 13-3002 / 107131 (115/230 V, EU) a complete analysis of the sample's 13-3003 / 107132 (115/230 V, US) oxidation stability in a short time period. Reference: Active Cool Standard methods: 13-3006 / 107133 (115/230 V, EU, Peltier) ASTM D 7525 (Gasoline) 13-3007 / 107134 (115/230 V, US, Peltier) ASTM D 7545 (Diesel, Biodiesel & Blends) EN 16 091 (Diesel, Biodiesel (FAME) & Blends) Rapid Small Scale Oxidation Test (RSSOT): PetroOxy Steel Datasheet: The automatic PetroOxy with stainless 13-3008.pdf (PetroOxy S Block) steel chamber initiates a very fast artificial 13-3016.pdf (PetroOxy S Peltier) aging process to evaluate the oxidation stability of natural oils/fats, food & Reference: cosmetics and water containing products. 13-3008 / 107135 (115/230 V, EU) The PetroOxy is cost saving due to a 13-3009 / 107136 (115/230 V, US) massive reduction of test time, improved repeatability and small sample volumen. Reference: Active Cool The PetroOxy requires manual re-cooling 13-3016 / 108338 (115/230 V, EU, Peltier) between tests by an externally chilled 13-3017 / 108339 (115/230 V, US, Peltier) cooling block. While the PetroOxy Active Cool with Peltier elements will re-cool automatically. Especially recommended for low boiling liquids. Oxidation Stability of Gasoline and Aviation Fuels: OBA 1 The semi-automatic OBA 1 is used for fuels Datasheet: to determine the stability (induction period) 13-1660.pdf (OBA 1) and the tendency to form gum (potential residue) under accelerated oxidation Reference: OBA 1 conditions. 13-1660 / 107052 (230 V, liquid) Programmable PA 5-OBA manometers on 13-1661 / 107053 (115 V, liquid) stainless steel oxidation vessels are available in combination with a liquid bath as OBA 1 Reference: OBA 1/T or as OBA 1/T with a dry heat bath. 13-1662 / 107054 (230 V, dry heat) 13-1663 / 107055 (115 V, dry heat) Standard methods: ASTM D 525, ASTM D 873, ISO 7536, Test places: JIS K2276, JIS K2287, FTM 791-3352, 1 - 4 FTM 791-3354, IP 40, IP 138 8 Oxidation Stability Oxidation Stability of Gasoline and Specifications Aviation Fuels: OBA 2 Datasheet: The semi-automatic OBA 2 safety arrange- 13-1664.pdf (OBA 2) ment has special features to comply with German safety regulations to avoid health- Reference: OBA 2 hazards caused by unexpected explosions 13-1664 / 108333 (230 V, liquid) as much as possible and also protect the 13-1665 / 108334 (115 V, liquid) expensive pressure sensors. The programmable PA 5-OBA manometers Reference: OBA 2/T on the stainless steel oxidation vessels are 13-1666 / 107056 (230 V, dry heat) available with a liquid bath as OBA 2 or as 13-1667 / 108335 (115 V, dry heat) OBA 2/T with a dry heat bath. Test places: Standard methods: 1 - 4 ASTM D 525, ASTM D 873, ISO 7536, JIS K2276, JIS K2287, FTM 791-3352, FTM 791-3354, IP 40, IP 138 Oxidation Characteristics: TOST/TOO The modular TOST liquid bath is used for Datasheets: testing the oxidation characteristics of 16-0586_ASTM943.pdf (TOST) various petroleum products. 16-0586_ASTM2274.pdf (TOST) Standardized glassware sets and 16-0586_ASTM4310.pdf (TOST) accessories are available. 16-0586_ISO4263.pdf (TOST) 16-0586_ISO12205.pdf (TOST) Standard methods: 16-0586_DIN51587.pdf (TOST) ASTM D 943, ASTM D 2274, ASTM D 4310, 16-0545.pdf (TOO) ASTM D 7462, ISO 12 205, ISO 4263-1, ISO 4263-2, ISO 4263-3, JIS C2101, Reference: JIS K2514, DIN 51 587, FTM 791-5308, IP 157, 16-0583 / 106563 (230 V) IP 388 16-0584 / 106564 (115 V) Test places: 1 - 4 Oxidation Stability of Lubricating Greases: OFA 2 Datasheet: The semi-automatic OFA 2 arrangement 17-0212.pdf (OFA 2) may be used for quality control to indicate batch-to-batch conformity of lubricating Reference: greases stored in an oxygen atmosphere 17-0212 / 107088 (oxidation vessel) in a sealed system at an elevated 17-1210 / 107030 (manometer) temperature. 17-0210 / 106583 (230 V, liquid bath) The programmable PA 5-OFA manometer 13-1672 / 106555 (230 V, dry heat bath) shall be combined with the stainless steel oxidation vessel and a liquid bath or dry Test places: heat bath. 1 - 4 Standard methods: ASTM D 942, JIS K2220, DIN 51 808, FTM 791-3453, IP 142, VV-L-791e-5314 9 Cold Flow Properties Cold Filter Plugging Point: CFPP I Specifications The cold filter plugging point test Datasheet: determinates the lowest temperature at 13-2418.pdf (CFPP I) which a fuel will give trouble free flow in certain fuel systems. It is defined as Reference: highest temperature at which a given 13-2418 / 107162 (230 V) volume of fuel fails to pass through a standardized filtration device in a specified Working range: time when cooled under the conditions down to -34 °C prescribed in the test method. A system of a metal-block cryostat with Test places: a 4-place cooling chamber provides the 1 chamber (4 places) required cooling temperature. Standard methods: ASTM D 6371, EN 116, JIS K2288, IP 309 Cloud & Pour Point: CAPP I Datasheet: The CAPP I is a metal-block cryostat 16-2372.pdf (CAPP I) designed to perform the cloud point test. It is the temperature at which a fuel starts Reference: becoming cloudy or begins to precipitate 16-2372 / 106533 (230 V, 1 bath) paraffin. The pour point is the lowest temperature at which movement of the test Working range: sample is observed. +20 °C to -69 °C Suitable for any petroleum products. Chamber temperatures: Standard methods: 0 °C to -69 °C ASTM D 97, ASTM D 2500, ASTM D 5853, ISO 3015, ISO 3016, EN 23 015, JIS K2269, Test places: JIS K2601, FTM 791-201, IP 15, IP 219, IP 441 1 chamber (4 places) Cloud & Pour Point: Datasheet: CAPP IV & V 16-2378.pdf (CAPP IV) 16-2360.pdf (CAPP V) Designed for an easy workflow, the CAPP IV & V with independently set Reference: of cooling chambers allows an instant 16-2378 / 107029 (230 V, 4 bath) transfer of the sample jar to the next lower 16-2360 / 106532 (230 V, 5 bath) chamber temperature. Suitable for any petroleum products. Working range: +20 °C to -69 °C Standard methods: ASTM D 97, ASTM D 2500, ASTM D 5853, Chamber temperatures: ISO 3015, ISO 3016, EN 23 015, JIS K2269, 0 °C, -18 °C, -33 °C, -51 °C, -69 °C JIS K2601, FTM 791-201, IP 15, IP 219, IP 441 Test places: 4 or 5 chambers (4 places each) 10

Description:
SMS 658 | Superpave® | VV-L-791e-5314 Suitable for biodiesel (FAME) & blends, distillate fuels . ASTM D 7545 (Diesel, Biodiesel & Blends).
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.