Tomás Caldeira Lourenço Licenciado em Ciências de Engenharia Civil Anomalies detection in adhesive wall tiling systems by infrared thermography Dissertação para obtenção do Grau de Mestre em Engenharia Civil – Perfil de Construção Orientador: Luís Manuel Cordeiro Matias, Investigador Auxiliar, Laboratório Nacional de Engenharia Civil Co-orientadora: Maria Paulina Faria Rodrigues, Professora Associada, Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa Júri: Presidente: Prof. Doutor Carlos Manuel Chastre Rodrigues Arguente: Prof. Doutor Fernando Manuel Anjos Henriques Vogal: Doutor Luís Manuel Cordeiro Matias Dezembro 2016 Anomalies detection in adhesive wall tiling systems by infrared thermography “Copyright” Tomás Caldeira Lourenço, FCT/UNL e UNL A Faculdade de Ciências e Tecnologia e a Universidade Nova de Lisboa têm o direito, perpétuo e sem limites geográficos, de arquivar e publicar esta dissertação através de exemplares impressos reproduzidos em papel ou de forma digital, ou por qualquer outro meio conhecido ou que venha a ser inventado, e de a divulgar através de repositórios científicos e de admitir a sua cópia e distribuição com objetivos educacionais ou de investigação, não comerciais, desde que seja dado crédito ao autor e editor. I II Acknowledgements I would like to thank some persons and organizations to whom I owe the possibility of bringing forth this masters dissertation. Firstly I would like to express my gratitude to Doctor Luís Matias (LNEC) and Prof. Doctor Paulina Faria (FCT/UNL) for the orientation and co-orientation of this work respectively, for the help and engagement through the learning process of this thesis and useful comments. I would also like to acknowledge Doctor Luís Silva and Mr. Miguel Mendes from Weber Saint- Gobain, for supporting this work not only by providing material and applying it on the external panels but also to the suggestions and interest shown during the process. To Eng. Helena Afonso from Revigrés, for providing the tiles used in this study. To Mr. José Carlos Matos and to Mr. Manuel Sadio to all the help with the measuring equipment. To Mr. José Fernandes Costa for the help and transmittance of practical knowledge on the specimens’ preparation. To all the staff from LNEC’s Buildings Department who participated in the project by wittingly supporting me, sharing their time and knowledge: Doctor Carlos Pina dos Santos, Engª. Maria Alexandra Costa, Engª. Sofia Malanho, Mrs. Vanda Cardoso, Mr. Acácio Monteiro, Mr. Bento Sabala and Mr. Carlos Raposo Saldanha. I would like to thank Eng. Vitor Silva for the valuable help to this dissertation’s presentation. I am also very grateful to all my friends and colleagues for the good moments, friendship and cooperation though out this course. A special thanks to my mother, father and brother for all the love, support, encouragement, care, trust and teaching through all the stages of my life. This work is dedicated to them. III IV Abstract Tiling systems for building facade coatings are widely used all over the world. Despite very common, mainly due to its aesthetic characteristics, this kind of cladding is characterised by a complex application, given the fact that it is a system in direct contact with a support (the rendered wall) and composed by three different components with specific characteristics and technical requirements: the tiles, the adhesive grout, and the joint grout. This complexity can result in several possible anomalies, as it is the case of detachment, the most common onerous one and probably the most difficult anomaly to early diagnosis in this type of cladding. Infrared thermography is a non-destructive testing method with a broad applicability in buildings’ inspection. The method consists in using a thermal camera that, by detecting thermal radiation, reads thermal variations that can indicate the presence of anomalies. Taking into account this diagnosis method’s potential, it was developed in LNEC a wide study where the results of thermographic surveys on laboratory specimens, exterior panels cladded with tiles with controlled anomalies and case studies of real situations are presented. In order to characterize the claddings behaviour and the anomalies’ detectability using this method, in a first phase eight specimens were studied in laboratory with differences in terms of: colour, thickness, kind of support, finishing and presence of anomaly. In a second phase, four panels divided into two experimental cells, located in LNEC’s campus, aiming to evaluate the diagnostic technique in exterior facades with differences in terms of tiles’ colour and support of application. As a complement of the laboratory surveys (indoors and outdoors) certain features of this kind of cladding were characterized, such as their emittance and reflectance. In order to evaluate infrared thermography’s diagnosis capability in real and unfamiliar situations, two real cases of buildings in Lisbon, cladded with ceramic tiles, were studied. The results obtained in the form of thermal differentials between “normal” and “anomalous” zones in a tiled facade or specimen proved that Infrared Thermography can be a valuable tool to early identification of anomalies, mainly detachments, in this kind of coating systems. Keywords: Non-destructive testing method, Anomaly, Tile, Detachment, Infrared Thermography, Facade. V VI Resumo O revestimento de fachadas de edifícios com ladrilhos é uma técnica bastante usada em todo mundo. Apesar de bastante comum, principalmente devido às suas características estéticas, este tipo de revestimento tem uma aplicação complexa, dado ser um sistema em contacto direto com o suporte (parede) e composto por três diferentes componentes com características e requisitos técnicos específicos. Esta complexidade pode resultar em diversas anomalias, como é o caso do destacamento, a anomalia mais comum e mais gravosa neste tipo de revestimentos e, provavelmente, a mais difícil de identificar precocemente. A termografia de infravermelhos é um método de diagnóstico não destrutivo com uma vasta aplicação na inspeção de edifícios. Este método baseia-se na leitura de temperaturas através da deteção de radiação térmica, cujas diferenças podem ser indício de anomalia. Tendo em conta o potencial deste método foi desenvolvido no LNEC um estudo amplo do qual se apresentam os resultados obtidos em ensaios termográficos realizados em provetes e painéis exteriores revestidos com ladrilhos, com anomalias controladas e em casos reais com anomalias desconhecidas. Para uma caracterização do comportamento do revestimento e da detetabilidade das anomalias com termografia foram em primeiro lugar executados e estudados em laboratório oito provetes, com diferenças em termos de: cor, espessura, acabamento, tipo de suporte e presença de anomalia. Numa segunda fase foram estudados quatro painéis divididos em duas fachadas de células experimentais localizadas no campus do LNEC, com o objetivo de avaliar a técnica de diagnóstico em fachadas exteriores com ladrilhos de diferentes cores e diferentes suportes de aplicação. Como complemento ao estudo dos sistemas (realizado no interior e no exterior) foram caracterizadas os parâmetros emitância e refletância dos ladrilhos de revestimento utilizados. Para validar a capacidade de diagnóstico da termografia em situações reais foram estudados três edifícios com revestimentos cerâmicos em Lisboa. Os resultados obtidos, sobre a forma de diferenciais de temperatura entre zonas “normais/sãs” e “anómalas” de uma parede revestida com ladrilhos, mostram que a termografia de infravermelhos é uma ferramenta capaz de identificar anomalias, sobretudo destacamentos, neste tipo de revestimento. Termos-chave: Método não destrutivo de diagnóstico, Anomalia, Ladrilho, Destacamento, Termografia de infravermelhos, Fachada. VII VIII
Description: