ebook img

Analyzing Sound Quality of Advanced Bone Anchored Hearing Aids PDF

57 Pages·2012·3.07 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Analyzing Sound Quality of Advanced Bone Anchored Hearing Aids

University of Alberta Analyzing Sound Quality of Advanced Bone Anchored Hearing Aids by Tyler Wetter A thesis submitted to the Faculty of Graduate Studies and Research in partial fulfillment of the requirements for the degree of Master of Science �in Speech Language Pathology Department of Speech Pathology and Audiology ©Tyler Wetter Spring 2013 Edmonton, Alberta Permission is hereby granted to the University of Alberta Libraries to reproduce single copies of this thesis and to lend or sell such copies for private, scholarly or scientific research purposes only. Where the thesis is converted to, or otherwise made available in digital form, the University of Alberta will advise potential users of the thesis of these terms. The author reserves all other publication and other rights in association with the copyright in the thesis and, except as herein before provided, neither the thesis nor any substantial portion thereof may be printed or otherwise reproduced in any material form whatsoever without the author's prior written permission Abstract In this study we explored whether differences in sound quality existed between new advanced Bone Anchored Hearing Aids (BAHA). Three groups of subjects were tested. Two groups, those with normal hearing and those with sufficient residual cochlear hearing, were tested with Oticon’s Ponto Pro to Cochlear’s BP100. The third group had either mixed hearing loss or single-sided deafness and they compared the more powerful devices (Oticon’s Ponto Pro Power and Cochlear’s BP110). Some differences emerged within the normal hearing listeners and the power user’s. However, no significant differences in sound quality were revealed in the non-power users of the Ponto Pro and BP100. These limited results most likely reflect a lack of power in the data due to the limited number of subjects per group. Continued data collection is warranted. Acknowledgements First and foremost I would like to thank my supervisor, Dr. Hodgetts. Thank you for your patience and support throughout this process. You told me early on that a great supervisor is one who will be there come crunch time. You most definitely were and I know this project could not have been successful without all your contributions. I also experienced a huge learning curve with this thesis and you were always there to answer any questions or concerns that I had. It was a pleasure working with you and getting to know you. I would also like to thank Amberley Ostevik. You were so patient with me and willing to answer questions I had about the project. I thank you for all your hard work with data collection and teaching me what it means to do research. You were such a pleasure to work with and I feel fortunate and grateful that I had the opportunity to work with you. In addition, I have to thank Herman Lundgren and Dylan Scott. I know this project would not have been possible without all the hard work and dedication you put into it. Thank you so much for answering my questions with diagrams. You both were very supportive and were always good for a few laughs. Thanks to both of you. I also want to thank my committee for the time and effort they put into this project. Your guidance and suggestions are greatly appreciated. Lastly, I would like to thank my family and my girlfriend for always encouraging me to keep going when times were tough. I know that this journey would not have been possible without all your support. I’m very fortunate to have such wonderful people in my life. Table of Contents Introduction  ..........................................................................................................................................  1   Research  Question(s)  ...................................................................................................................................  8   Method  ....................................................................................................................................................  9   Subjects  .............................................................................................................................................................  9   Group  1  –  Normal  Hearing  Subjects  ......................................................................................................................  9   Groups  2  and  3  –  BAHA  Users.  .................................................................................................................................  9   Procedure  .......................................................................................................................................................  10   Phase  1  -­‐  Hearing  Testing,  Device  Setting  and  Recording  ........................................................................  10   Recordings  .....................................................................................................................................................................  12   De-­‐convolution  Process  ...........................................................................................................................................  17   Phase  2  –  Sound  Quality  Assessment  .................................................................................................................  21   Results  ..................................................................................................................................................  26   Normal  Hearing  Subjects  ..........................................................................................................................  26   Non-­‐Power  Users:  Ponto  Pro  and  BP100  .............................................................................................  32   Power  Users  –  Ponto  Pro  Power  and  BP110  ......................................................................................  36   Discussion  ...........................................................................................................................................  44   Normal  Hearing  Subjects  ..........................................................................................................................  44   Non-­‐power  users  ..........................................................................................................................................  45   Power  Users  ...................................................................................................................................................  47   Conclusion  ..........................................................................................................................................  48 List of Tables Table  1.  Subject  Details.  .....................................................................................................................................  10   Table  2  Correlations  between  scores  with  the  different  transducers  (Ponto  Pro  and  BP100)   for  the  non  Power  BAHA  users.  Bolded  rows  reached  significance  .....................................  34   Table  3.  Correlations between scores with the different transducers (Ponto Pro Power and BP110) for the Power BAHA users. Bolded rows reached significance.  ..................................  38 List of Figures Figure  1.  Bone  anchored  hearing  aid  and  titanium  implant  in  the  skull.  ........................................  2   Figure  2.  Devices  used  in  the  study.  The  top  two  are  from  Cochlear  Corporation  and  the   bottom  two  are  from  Oticon  Medical  ....................................................................................................  8   Figure  3.  Mean  force  level  thresholds  on  a  skull  simulator  for  each  subject  group  (non-­‐ power  and  power  users)  obtained  with  each  of  the  manufacturer’s  devices.  .................  11   Figure  4.  National  Instruments  data  acquisition  system  (this  is  the  same  DAQ  that  has  been   integrated  into  the  test  box)  ..................................................................................................................  13   Figure  5.  (a)  Skull  simulator  and  (b)  internal  components  of  skull  simulator  consisting  of   an  abutment,  mass  and  accelerometer  ..............................................................................................  13   Figure  6. SoundQual.vi recording software, designed using Labview  ................................................  14   Figure  7.  Audioscan  Verifit,  Skull  Simulator  and  Sound  Proofed  Test  Box  .................................  15   Figure  8.  DecovoluteMe.vi software program  .............................................................................................  16   Figure  9.  Schematic  of  de-­‐convolution  process  .......................................................................................  18   Figure  10.  Comparisons  of  the  original  music  .wav  file  to  the  recorded  and  the  de-­‐ convoluted  music  .wav  file  for  each  processor.  In  addition,  a  difference  waveform   between  the  original  file  and  the  final  de-­‐convoluted  file.  (a)  BP100,  (b)  Ponto  Pro,  (c)   BP110  and  the  (d)  Ponto  Pro  Power.  .................................................................................................  20   Figure  11.  Normalized,  de-­‐convoluted  spectra  of  each  BAHA  device  compared  to  the   original  music  sample  ...............................................................................................................................  21   Figure  12.  SoundQualTestv2.vi  software  ...................................................................................................  22   Figure  13.  Visual  analog  scale  used  to  judge  sound  quality  ...............................................................  22   Figure  14.  Isolated  (i.e.  ,“naked”)  Ponto  Pro  and  BP100  transducers  ...........................................  24   Figure  15.  Frequency/Output  responses  of  the  4  naked  BAHA  transducers  used  in  the   study.  ................................................................................................................................................................  25   Figure  16.  Main  effect  of  mode  of  stimulation.  Condition  1  is  bone  conduction  and   condition  2  is  air  conduction.  ................................................................................................................  27   Figure  17.  Main  effect  of  device.  Device  1  is  the  Ponto  Pro;  device  2  is  the  BP100  .................  28   Figure  18.  Main  effect  of  level.  Level  1  is  75  dB  SPL  input  and  level  2  is  60  dB  SPL  input.  ..  29   Figure  19.  Main  effect  of  stimulus  type.  Type  1  was  male  speech;  type  2  was  female  speech   and  type  3  was  music.  ...............................................................................................................................  30   Figure  20.  Overall  contrasts  from  the  4-­‐way  significant  interaction  from  normal  hearing   listeners.  Error  bars  represent  the  95%  confidence  interval  around  the  mean.  ............  32   Figure  21.  Frequency  response/audibility  curves  for  the  60  dB  SPL  male  speech  signals.  .  33   Figure  22.  Frequency  response/audibility  curves  for  the  75  dB  SPL  male  speech  signals..33   Figure  23.  Sound  quality  results  when  measured  using  the  Ponto  Pro  naked  transducer.  .  35   Figure  24.  Sound  quality  results  when  measured  using  the  BP100  naked  transducer.  ........  36   Figure  25.  Frequency  response/audibility  curves  for  the  60  dB  SPL  male  speech  signals..37   Figure  26.  Frequency  response/audibility  curves  for  the  75  dB  SPL  male  speech  signals.  .  37   Figure  27.  Main  effect  of  Device  for  the  Ponto  Pro  Power  transducer  condition.  Device  1  is   the  Ponto  Pro  Power  and  Device  2  in  the  BP110.  .........................................................................  39   Figure  28.  Interaction  between  Device  and  Level  for  the  Ponto  Pro  Power  transducer   condition.  Device  1  is  the  Ponto  Pro  Power  and  Device  2  is  the  BP110.  Level  1  is  75  dB   SPL  input  and  Level  2  is  the  60  dB  SPL  input.  ................................................................................  40 Figure  29.  Means  plus  the  95%  CI  for  each  of  the  twelve  conditions  under  test  with  the   naked  Ponto  Pro  Power  transducer.  ..................................................................................................  41   Figure  30.  Main  effect  of  Device  when  rated  using  the  naked  BP110  transducer.  Device  1  is   the  Ponto  Pro  Power  and  Device  2  is  the  BP110.  .........................................................................  42   Figure  31.  Means  plus  the  95%  CI  for  each  of  the  twelve  conditions  under  test  with  the   naked  BP110  transducer.  ........................................................................................................................  43   Figure  32.    Differences  in  2  non-­‐power  subjects  sound  quality  ratings.  ......................................  46 Introduction     Bone anchored hearing aids (BAHAs) have become increasingly popular for individuals who have chronic otitis media (ear infections), atresia (absence of the ear canal), and single sided deafness. BAHAs can be fitted for individuals with conductive or sensorineural hearing loss. Traditionally, bone conduction hearing aid devices (BCHAs) were fitted to headbands or eyeglasses. These techniques had limitations due to pressure, causing users to experience discomfort, pressure sores and headaches (Bance et al., 2002). Bance and colleagues (2002) also noted that even when these traditional devices had good skin contact, the skin and subcutaneous tissue could dampen the signal by as much as 20 dB. This dampening, accompanied with the need to continuously loosen the headband to avoid discomfort, resulted in significant sound quality limitations. Others (Hakansson et al., 1994) noted that the appearance of the BCHAs on a headband hindered these devices further and concluded they should be considered a last resort. In contrast, the BAHA uses direct bone conduction. In order to achieve this, a surgically implanted titanium screw is placed in the parietal/temporal region of the skull. Titanium has a unique ability to promote osseointegration when placed into bone (Hakansson et al., 1994). When enough time has passed (typically 6 weeks to 3 months) the screw will be stable and capable of anchoring a BAHA. The BAHA is connected to the screw via a titanium abutment. With this system, the BAHA delivers sound directly to the bone without any loss of energy to the skin and subcutaneous tissue (Hakansson, 1994). Although the BAHA device is a more expensive solution, Snik et al. (2005) claim that this can be justified by fewer trips to the clinic and ultimately, improved communication performance. Snik and colleagues (2005) also 1 indicated that implantation of the screw is achieved in 90 - 98% of cases, with high degrees of safety.   Figure 1. Bone anchored hearing aid and titanium implant in the skull. Image source: http://ent.uci.edu/BAHA.htm Reports indicate superior performance of BAHAs over conventional bone conduction hearing aids because sound quality remains steady even at higher volume settings (Snik et al., 2005). Snik and colleagues (2005) point to the fact that BAHAs are capable of more efficient sound transmission (especially in the high frequencies) through direct bone conduction, which ultimately results in better speech perception. Bance et al. (2002) conducted a study that compared the audiometric performance of BAHAs to air conduction hearing aids. They concluded that regardless of which hearing aid was used, it never restored or rehabilitated the patients to the level of normal listeners. In all cases aided hearing-impaired subjects performed worse than normal hearing individuals. In addition, they concluded that both hearing aids produced very similar audiometric results. Sink et al. (2005) echoed this finding, stating that ambiguous results were found for those individuals who switched from air conduction devices to bone anchored hearing aids. They concluded that BAHAs were not superior to air conduction aids. Mylanus et al. (1998) however, states that once the air-bone gap is greater then approximately 30 dB SPL, better results should be 2 expected with BAHA devices. This is because air conduction hearing aids require higher gains, which ultimately result in increased opportunities for feedback and poorer sound quality. Mylanus et al. (1998) also stated that the majority of the patients in the study preferred the BAHA device, when compared to their well-fitted air conduction aids. This appeared to be due to a decreased number of visits to the outpatient clinic and a reduction in ear infections. The study did indicate that neither type of hearing aid was preferred over the other when speech recognition in noisy environments was evaluated. Flynn et al. (2009) conducted a study that examined solutions available to those individuals with severe mixed hearing loss. Their results confirmed those of Mylanus et al (1998), concluding that BAHAs were superior devices once the air-bone gap exceeded 30 dB SPL. The researchers examined ten subjects with mixed hearing loss who had worn a BAHA device for at least a year. Mixed hearing loss was defined as an average sensorineural loss greater than 25 dB SPL, in addition to an air-bone gap exceeding 30 dB SPL. In the study a Baha Intenso was compared to an air conduction device, Oticon Sumo DM, which is a digital superpower hearing aid. The results of the study indicated that all subjects increased speech understanding in noise with the BAHA. Furthermore, all subjects reported that they preferred the sound quality of the BAHA to that of the air conduction hearing aid. Although this study indicates that BAHA users preferred the bone conduction device to an air conduction aid, it is important to remember that this was only for people with severe mixed hearing loss and only investigated one particular BAHA device. Further research is still needed in order to determine what sound quality differences exist between various BAHAs. Even though BAHA devices have been proven to be effective for individuals with chronic otitis media (COM) and external auditory canal malformations, limited research has 3

Description:
Permission is hereby granted to the University of Alberta Libraries to reproduce single copies of this thesis and to lend or sell such copies for private, scholarly or scientific research purposes only. Where the thesis is converted to, or otherwise made available in digital form, the University of
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.