01-B2 STOREFRONTS ALUMINUM Table of Contents Flush Front™ • Series FF450 • Series FF451 • Series FT451 • Series FF600 B • Series FF601 • Series FT601 SECTION B2 PAGE Series FF450, FF451, FT451, FF600, FF601, and FT601 SPECIFICATIONS..................................................................................................................................02-B2 and03-B2 TECHNICAL DATA....................................................................................................................................................04-B2 SPECIAL FEATURES................................................................................................................................................05-B2 Series FF450 TYPICAL DETAILS ................................................................................................................................06-B2 thru11-B2 WINDLOAD CHARTS ............................................................................................................................12-B2 and13-B2 DEADLOAD CHARTS ..............................................................................................................................................14-B2 Series FF451 and FT451 TYPICAL DETAILS ................................................................................................................................15-B2 thru21-B2 WINDLOAD CHARTS ............................................................................................................................22-B2 and23-B2 DEADLOAD CHARTS ..............................................................................................................................................24-B2 Series FF600 TYPICAL DETAILS ................................................................................................................................25-B2 thru29-B2 WINDLOAD CHARTS ............................................................................................................................30-B2 and31-B2 DEADLOAD CHARTS ..............................................................................................................................................32-B2 Series FF601 and FT601 TYPICAL DETAILS ................................................................................................................................33-B2 thru39-B2 WINDLOAD CHARTS ............................................................................................................................40-B2 and41-B2 DEADLOAD CHARTS ..............................................................................................................................................42-B2 ACCESSORIES AND GLAZING GASKETS (ALL SYSTEMS)................................................................43-B2 thru45-B2 MISCELLANEOUS FRAMING................................................................................................................46-B2 thru48-B2 Due to the diversity in state/provincial, local, and federal laws and codes that govern the design and application of architectural products, it is the responsibility of the individual architect, owner, and installer to ensure that products selected for use on projects comply with all applicable building codes and laws. U.S. Aluminum exercises no control over the use or application of its products, glazing materials, and operating hardware, and assumes no responsibility thereof. The rapidly changing technology within the architectural aluminum products industry demands that U.S. Aluminum reserve the right to revise, discontinue or change any product line, specification or electronic media without prior written notice. NOTE:Dimensions in parentheses ( ) are millimeters unless otherwise noted. Other metric units shown in this publication are: m - meter Kg - kilogram Pa - pascal KPa - kilopascal MPa - megapascal Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 02-B2 STOREFRONTS ALUMINUM Specifications Flush Front™ • Series FF450 SECTION 08 41 13 ALUMINUM FRAMED STOREFRONTS • Series FF451 • Series FF600 • Series FF601 B SERIES FACE WIDTH DEPTH GLAZING INFILL GLAZING METHOD FF450 1-3/4" (44.5) 4-1/2" (114.3) 1/4" (6) or 3/8" (10) FF451 2" (50.8) 4-1/2" (114.3) 1" (25) Exterior/Interior FF600 1-3/4" (44.5) 6" (152.4) 1/4" (6) or 3/8" (10) FF601 2" (50.8) 6" (152.4) 1" (25) I. GENERAL DESCRIPTION water penetration at test pressure of A Fluoropolymer paint coating Work Included: Furnish all necessary 8 psf (384 Pa) when tested with the conforming with the requirements of materials, labor, and equipment for the high performance subsill. AAMA 2605. Color shall be (Specify a complete installation of aluminum Structural Performance:shall be U.S. Aluminum standard color). framing as shown on the drawings and tested in accordance with ASTM E 330 specified herein. (Specifier Note: and based on: FABRICATION It is suggested that related items such • Maximum deflection of L/175 of the The framing system shall provide for as aluminum entrance doors, glass, span flush glazing on all sides with no and sealants be included whenever • Allowable stress with a safety factor projecting stops. Vertical and possible). of 1.65 horizontal framing members shall have Work Not Included: Structural support The system shall perform to this a nominal face dimension of (Specify). of the framing system, interior criteria under a windload of (Specify) Overall depth shall be (Specify). closures, trim. (Specifier list other psf. Entrance framing members shall be exclusions). Testing Procedures - compatible with glass framing in Related Work Specified Elsewhere: ASTM 283, E 331, and E 330 - appearance. Provide for internal (Specifier list). Laboratory performance testing. drainage of infiltrated water into an AAMA 503-08 - Newly installed extruded aluminum subsill channel QUALITY ASSURANCE storefronts. AAMA 511-08 - Installed where it is drained to the exterior Drawings and specifications are storefronts after six months. through weep slots. based on the Series (Specify) Flush Front™ System as manufactured by II. PRODUCTS MATERIALS III. EXECUTION INSTALLATION U.S. Aluminum. Whenever substitute Extrusions shall be 6063-T5 alloy and All glass framing shall be set in correct products are to be considered, temper (ASTM B221 alloy T5 temper). locations as shown in the details and supporting technical literature, Fasteners, where exposed, shall be shall be level, square, plumb, and in samples, drawings, and performance aluminum, stainless steel or zinc alignment with other work in data must be submitted 10 days plated steel in accordance with ASTM accordance with the manufacturer’s prior to bid in order to make a valid A 164. Perimeter anchors shall be installation instructions and approved comparison of the products involved. aluminum or steel, providing the steel shop drawings. All joints between Test reports certified by an is properly isolated from the aluminum. framing and the building structure shall independent test laboratory must be Glazing gaskets shall be E.P.D.M. be sealed in order to secure a made available upon request. elastomeric extrusions. watertight installation. PERFORMANCE REQUIREMENTS FINISH PROTECTION AND CLEANING Air Infiltration:shall be tested in All exposed framing surfaces shall be After installation the General accordance with ASTM E 283. free of scratches and other serious Contractor shall adequately protect Infiltration shall not exceed .06 cfm blemishes. Aluminum extrusions shall exposed portions of aluminum per square foot (.0003m3/sm2) of be given a caustic etch followed by surfaces from damage by grinding and fixed area when tested at 6.24 psf an anodic oxide treatment to obtain… polishing compounds, plaster, lime, (300 Pa). (Specify one of the following): acid, cement or other contaminants. Water Infiltration:shall be tested in _____#11 Clear anodic coating The General Contractor shall be accordance with ASTM E 331. No _____#22 Dark Bronze anodic coating responsible for final cleaning. _____#33 Black anodic coating Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 03-B2 STOREFRONTS ALUMINUM Specifications Thermal Flush Front™ • Series FT451 SECTION 08 41 13 ALUMINUM FRAMED STOREFRONTS • Series FT601 SERIES FACE WIDTH DEPTH GLAZING INFILL GLAZING METHOD B FT451 4-1/2" (114.3) 2" (50.8) 1" (25) Exterior/Interior FT601 6" (152.4) I. GENERAL DESCRIPTION • Allowable stress with a safety factor anodic oxide treatment to obtain… Work Included: Furnish all necessary of 1.65 (Specify one of the following): materials, labor, and equipment for the The system shall perform to this _____#11 Clear anodic coating complete installation of aluminum criteria under a windload of (Specify) _____#22 Dark Bronze anodic coating framing as shown on the drawings and psf. Structural Integrity - Manufacturer _____#33 Black anodic coating specified herein. (Specifier Note: It is shall provide a Two Year Warranty on A Fluoropolymer paint coating suggested that related items such as thermal framing against failure. conforming with the requirements of aluminum entrance doors, glass, and Thermal Performance - Series AAMA 2605. Color shall be (Specify sealants be included whenever FT451/FT601 shall be tested in a U.S. Aluminum standard color). possible). accordance with NFRC 100, 200, Work Not Included: Structural support and AAMA 1503. FABRICATION of the framing system, interior The system shall perform to this The framing system shall provide for closures, trim. (Specifier list other criteria under a windload of (Specify) flush glazing on all sides with no exclusions). psf. projecting stops. Vertical and Related Work Specified Elsewhere: Testing Procedures - horizontal framing members shall have (Specifier list). ASTM 283, E 331, and E 330 - a nominal face dimension of 2" (50.8). Laboratory performance testing. Overall depth shall be (Specify). QUALITY ASSURANCE AAMA 503-08 - Newly installed Entrance framing members shall be Drawings and specifications are based storefronts. AAMA 511-08 - Installed compatible with glass framing in on the Series (Specify)Thermal Flush storefronts after six months. appearance. Provide for internal Front™System as manufactured by drainage of infiltrated water into an U.S. Aluminum. Whenever substitute II. PRODUCTS MATERIALS extruded aluminum subsill channel products are to be considered, Extrusions shall be 6063-T5 alloy and where it is drained to the exterior supporting technical literature, temper (ASTM B221 alloy T5 temper), through weep slots. samples, drawings, and performance thermally broken by a two part data must be submitted 10 days chemically cured high density III. EXECUTION INSTALLATION prior to bid in order to make a valid polyurethane. To ensure that All glass framing shall be set in correct comparison of the products involved. composite strength remains unaltered locations as shown in the details and Test reports certified by an during thermal cycling, a mechanical shall be level, square, plumb, and in independent test laboratory must be bond between the aluminum and the alignment with other work in made available upon request. thermal filling shall be created by accordance with the manufacturer’s mechanically abrading the extrusion installation instructions and approved PERFORMANCE REQUIREMENTS thermal cavity prior to filling with the shop drawings. All joints between Air Infiltration:shall be tested in polyurethane polymer. Fasteners, framing and the building structure shall accordance with ASTM E 283. where exposed, shall be aluminum, be sealed in order to secure a Infiltration shall not exceed .06 cfm per stainless steel or zinc plated steel in watertight installation. square foot (.0003m3/sm2) of fixed area accordance with ASTM A 164. when tested at 6.24 psf (300 Pa). Perimeter anchors shall be aluminum Water Infiltration:shall be tested in or steel, providing the steel is properly PROTECTION AND CLEANING accordance with ASTM E 331. No isolated from the aluminum. Glazing After installation the General water penetration at test pressure of 8 gaskets shall be E.P.D.M. elastomeric Contractor shall adequately protect psf (384 Pa). When tested with the extrusions. exposed portions of aluminum high performance subsill. surfaces from damage by grinding and Structural Performance:shall be FINISH polishing compounds, plaster, lime, tested in accordance with ASTM E All exposed framing surfaces shall be acid, cement, or other contaminants. 330 and based on: free of scratches and other serious The General Contractor shall be • Maximum deflection of L/175 of the blemishes. Aluminum extrusions shall responsible for final cleaning. span be given a caustic etch followed by an Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 04-B2 STOREFRONTS ALUMINUM Technical Data Flush Front™ • Series FF450 • Series FF451 Flush Front™Systems feature screw race joinery and panel type installation, which allows for • Series FT451 shop or job site fabrication. Injection molded water deflectors at intermediate horizontals, and a • Series FF600 B continuous sill gutter with factory pre-punched weep slots, ensure control of any infiltrated water. • Series FF601 The plane of the glass may be reversed from exterior to interior or any combination to give these • Series FT601 standard systems a custom look. Flush Front™Series FT451 and FT601 offer improved thermal performance using the Poly-Aluminizer™thermal break technology as described on page 44-B1. All series may be glazed from the interior or exterior using a top load E.P.D.M. glazing gasket, see page 01-B3. This multi-purpose product was also designed and tested for use as a Window Wall System, and is an ideal choice for fixed horizontal ribbon window applications. Flush Front Systems accommodate most U.S. Aluminum Entrance Doors. FLUSH FRONT SERIES WIDTH DEPTH GLAZING INFILLS APPLICATION FF450 1-3/4" (44.5) 4-1/2" (114.3) 1/4" (6) or 3/8" (10) FF451 2" (50.8) 4-1/2" (114.3) 1" (25) Ground Floor to FT451 (Thermal) 2" (50.8) 4-1/2" (114.3) 1" (25) Mid-Rise Buildings. Ideal for Fixed FF600 1-3/4" (44.5) 6" (152.4) 1/4" (6) or 3/8" (10) Horizontal Ribbon Windows. FF601 2" (50.8) 6" (152.4) 1" (25) FT601 (Thermal) 2" (50.8) 6" (152.4) 1" (25) GLASS SIZES* Series FF450 and FF600 = Daylight Opening + 5/8" (15.9) for 1/4" (6) Glass Series FF451, FT451, FF601, and FT601 = Daylight Opening + 7/8" (22.2) for 1" (25) Glass * These formulae do not take into account glass tolerances. Consult glass manufacturer before ordering glass. Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 05-B2 STOREFRONTS ALUMINUM Special Features Flush Front™ • Series FF450 Flush Front™Systems allow the plane • Series FF451 of the glass to be reversed from exterior • Series FT451 to interior or any combination to give • Series FF600 B these standard systems a custom look. • Series FF601 Flush Front™is ideal for use in storefront • Series FT601 and punched opening or ribbon window applications. Flush Front™Systems accommodate most U.S. Aluminum Entrance Doors. System features screw race joinery with split vertical mullions which allows for framing to be shop fabricated and shipped to the job site partially or totally assembled into panels. The assembled panel units are then snapped together into long runs. Subsills with factory pre-punched weep slots must be used with these systems. Apply silicone to two sides of glazing pocket at vertical/horizontal joint and glazing reglets. Slide water deflector, down into position. Seal over top edges of water deflector, leaving a gap on outside edge allowing water to drain into subsill. Water Deflector Stretch "W" Block and slide it between glass and mullion into deep glazing pocket. Push it all "W" Edge Block the way until it clears glass and locks into place. These blocks are used to prevent glass from "walking" out of the pocket caused by extreme vibration or minor earthquakes. Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 06-B2 STOREFRONTS ALUMINUM Typical Details Flush Front™ • Series FF450 FLUSH OUT FOR 1/4" (6) OR 4 B 3/8" (10) GLAZING NOTE:NP225E.P.D.M. Glazing 1 2 3 Gaskets used on both sides 5 of 1/4" (6) glass throughout. NP238E.P.D.M. Glazing NOTE:Part numbers shown are Gaskets for 3/8" (10) glazing. available in 24' (7.3 m) stock lengths. Visit usalum.comfor more information. 6 TYPICAL ELEVATION EC480Subsill's SS452Optional SS469Optional End Closure (Typ.) Steel Stiffener Steel Stiffener FF452 FF452 FF469 4-1/2" PF100 (114.3) RF200 FF460 1-3/4" D.L.O. 1-3/4" D.L.O. 1-3/4" D.L.O. (44.5) (44.5) (44.5) 1/4" (6.4) FRAME WIDTH Min. ROUGH OPENING 1 2 3 1/2" (12.7) HC200 Optional Head Anchor 1-3/4" FF473 FF473 (44.5) M-473 M-473 O. 4 4 NG T D.L. NI GH PE EI FH463 M-875 FH453 O H 1-3/4" GH ME (44.5) U A RO FR M-473 5 5 O. L. D. FF482 6 FF483 6 1-3/4" M-875 FF400 FF400 (44.5) Weep Slot 1/4" (6.4) Min. Interior Glazing Exterior Glazing NOT TO SCALE Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 07-B2 STOREFRONTS ALUMINUM Typical Details Flush Front™ • Series FF450 FLUSH IN FOR 1/4" (6) OR 3/8" (10) GLAZING B 4 1 2 3 NOTE:NP225E.P.D.M. Glazing Gaskets used on both sides NOTE:Part numbers shown are 5 of 1/4" (6) glass throughout. available in 24' (7.3 m) stock lengths. NP238E.P.D.M. Glazing Visit usalum.comfor more information. Gaskets for 3/8" (10) glazing. 6 TYPICAL ELEVATION EC480Subsill's End Closure FF452 FF452 FF469 4-1/2" (114.3) PF100 RF200 FF460 SS452Optional SS469Optional 1-3/4" 1-3/4" Steel Stiffener 1-3/4" Steel Stiffener (44.5) D.L.O. (44.5) D.L.O. (44.5) D.L.O. 1/4" (6.4) FRAME WIDTH Min. ROUGH OPENING 1 2 3 1/2" HC200 (12.7) Optional Head Anchor FF473 1-3/4" (44.5) M-473 4 O. L. G D. N T NI GH OPE HEI 1-3/4" FH463 H E (44.5) G M U A O R M-473 5 R F O. L. D. 6 FF482 FF400 1-3/4" (44.5) 1/4" (6.4) Exterior Glazing Min. NOT TO SCALE Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 08-B2 STOREFRONTS ALUMINUM Typical Details Flush Front™ • Series FF450 FLUSH IN / FLUSH OUT FOR 1/4" (6) OR B 3/8" (10) GLAZING 5 8 1 2 3 2 4 NOTE:Part numbers 6 9 shown are available in 24' (7.3 m) stock lengths. NOTE:NP225E.P.D.M. Glazing Visit usalum.comfor Gaskets used on both sides more information. of 1/4" (6) glass throughout. 7 10 NP238E.P.D.M. Glazing Gaskets for 3/8" (10) glazing. TYPICAL ELEVATION EC480Subsill's End Closure FF452 FF452 FF452 4-1/2" FF469 PF100 (114.3) RF200 RF200 FF460 1-3/4" D.L.O. 1-3/4" D.L.O. 1-3/4" D.L.O. 1-3/4" (44.5) (44.5) (44.5) (44.5) 1/4" (6.4) FRAME WIDTH Min. ROUGH OPENING 1 2 3 4 1/2" HC200 (12.7) Optional Head Anchor 1-3/4" FF473 FF473 (44.5) M-473 M-473 5 8 O. L. G D. N T NI GH PE EI 1-3/4" FH453 FH463 O H H E (44.5) G M U A RO FR 6 M-473 9 O. L. D. FF483 7 FF482 10 1-3/4" FF400 FF400 (44.5) 1/4" (6.4) Min. Exterior Glazing NOT TO SCALE Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 09-B2 STOREFRONTS ALUMINUM Typical Details Flush Front™ • Series FF450 DOOR FRAMING 5 NOTE:Doors are available in stock to B accommodate 36" x 84" (914 x 2134) and 72" x 84" (1829 x 2134) door openings. 1 2 NOTE:NP225E.P.D.M. Glazing Visit usalum.comfor more information. Gaskets used on both sides 6 of 1/4" (6) glass throughout. 3 4 NP238E.P.D.M. Glazing Gaskets for 3/8" (10) glazing. 7 CENTER HUNG DOOR 1/2" (12.7) PF100Filler (Typ.) FF436 FF436 1-3/4" JS463 (44.5) RF200 5 M-453 20101M17 O. Center Hung L. Closer D. 3/16" 105° N.H.O. D.L.O. (4.8) M-122/ M-122/ M-123 M-123 1 2 2-1/2" (63.5) 1-3/4" (44.5) FF436/ FF436/ JC457/ Center J-450 P-050 P-050 P-427 Pivot Top T D-201 D-201 H Portion RF200 G EI M-550 H E M-550 M-550 D-300 M A R F 6 6 1/8" 1/8" (3.2) (3.2) 1-3/4" D.O. 1-3/4" O. (44.5) (44.5) D. FRAME WIDTH M-550 M-550 7 7 3 4 D-101 D-101 3/16" (4.8) TH014Threshold TH017Threshold 1/2" (Use With Floor Closers) (12.7) NOT TO SCALE Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2 10-B2 STOREFRONTS ALUMINUM Typical Details Flush Front™ • Series FF450 DOOR FRAMING 5 8 B NOTE:Doors are available 1 2 1 2 in stock to accommodate 36" x 84" (914 x 2134) and 6 9 72" x 84" (1829 x 2134) door openings. Visit 3 4 3 4 NOTE:NP225E.P.D.M. Glazing Gaskets used on both sides usalum.comfor of 1/4" (6) glass throughout. more information. NP238E.P.D.M. Glazing 7 7 Gaskets for 3/8" (10) glazing. OFFSET HUNG DOORS 1/2" (12.7) PF100Filler (Typ.) FF436 FF436 1-3/4" FF473 FF473 P-050 P-050 (44.5) RF200 I-425/ 5 M-473 M-473 I-459 O. L. D. 3/4" I-425/ I-425/ C2lo1s2e0r1 WUith D.L.O. (19.1) I-459 I-459 Offset Arm 105° N.H.O. 1 2 2-1/2" (63.5) 1-3/4" (44.5) T H FF436/ FF436/ G J-450 DS047 DS047 EI 1/8" DS037/ DA201 H (3.2) RF200 ME D-201 MC037 A R M-550 D-101 F M-550 M-550 DT550 6 3/32" 3/32" (2.4) (2.4) O. D. 1-3/4" D.O. 1-3/4" (44.5) (44.5) Door Sweep Door Sweep FRAME WIDTH 7 With With Concealed Concealed Fasteners Fasteners 3 4 D-101 D-101 3/16" 3/16" (4.8) BW200 (4.8) BW200 TH250 TH250 1/2" 1/2" (12.7) (12.7) NOT TO SCALE Online usalum.com By Phone (800) 262-5151 Online crlaurence.com By Phone (800) 421-6144 B2

Description:
Deadload charts are based on 1/8" (3.2) maximum allowable deflection at the center point of the horizontal mullion and on a glass weight of 3.25 psf (15.87
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.