a B-1 PPendix G i eotechnical nvestiGation UPDATED GEOTECHNICAL INVESTIGATION PROPOSED MIXED-USE DEVELOPMENT 5732, 5740, 5750, 5756, 5762, AND 5766 WEST HOLLYWOOD BOULEVARD LOS ANGELES, CALIFORNIA TRACT: GRIDER AND HAMILTON’S GRANT PLACE LOTS: 2, 3, 4, 5, 6, AND 15 FEET OF WEST END OF 7 PREPARED FOR CAMBRA REALTY BEVERLY HILLS, CALIFORNIA PROJECT NO. A8960-06-01 NOVEMBER 12, 2014 Project No. A8960-06-01 November 12, 2014 VIA E-MAIL Mr. Michael Schlesinger Cambra Realty 9601 Wilshire Boulevard, Penthouse Beverly Hills, California 90210 Subject: UPDATED GEOTECHNICAL INVESTIGATION PROPOSED MIXED-USE DEVELOPMENT 5732, 5740, 5750, 5756, 5762, AND 5766 WEST HOLLYWOOD BOULEVARD LOS ANGELES, CALIFORNIA TRACT: GRIDER AND HAMILTON’S GRANT PLACE LOTS: 2, 3, 4, 5, 6, AND 15 FEET OF WEST END OF 7 Dear Mr. Schlesinger: In accordance with your authorization of our proposal dated October 7, 2014, we have prepared this updated geotechnical investigation for the proposed mixed-use development to be located at 5732, 5740, 5750, 5756, 5762, and 5766 West Hollywood Boulevard in the City of Los Angeles, California. The accompanying report presents the findings of our study, and our conclusions and recommendations pertaining to the geotechnical aspects of proposed design and construction. Based on the results of our investigation, it is our opinion that the site can be developed as proposed provided the recommendations in this report are followed and implemented during design and construction. If you have any questions regarding this report, or if we may be of further service, please contact the undersigned. Very truly yours, GEOCON WEST, INC. Petrina Zen Susan F. Kirkgard Jelisa M. Thomas Staff Engineer CEG 1754 PE 74946 (EMAIL) Addressee TABLE OF CONTENTS 1.  PURPOSE AND SCOPE ................................................................................................................. 1  2.  SITE CONDITIONS & PROJECT DESCRIPTION ....................................................................... 1  3.  GEOLOGIC SETTING .................................................................................................................... 2  4.  GEOLOGIC MATERIALS .............................................................................................................. 2  4.1  Artificial Fill .......................................................................................................................... 3  4.2  Alluvial Fan Deposits ............................................................................................................ 3  5.  GROUNDWATER ........................................................................................................................... 3  6.  GEOLOGIC HAZARDS .................................................................................................................. 3  6.1  Surface Fault Rupture ............................................................................................................ 3  6.2  Seismicity ............................................................................................................................... 4  6.4  Seismic Design Parameters .................................................................................................... 5  6.5  Liquefaction Potential ............................................................................................................ 6  6.6  Slope Stability ........................................................................................................................ 7  6.7  Seismically-Induced Settlement ............................................................................................. 7  6.8  Earthquake-Induced Flooding ................................................................................................ 7  6.9  Tsunamis, Seiches and Flooding ............................................................................................ 8  6.10  Oil Fields & Methane Potential ............................................................................................. 8  6.11  Subsidence ............................................................................................................................. 8  7.  CONCLUSIONS AND RECOMMENDATIONS ........................................................................... 9  7.1  General ................................................................................................................................... 9  7.2  Soil and Excavation Characteristics ..................................................................................... 11  7.3  Minimum Resistivity, pH, Chloride and Water-Soluble Sulfate ......................................... 11  7.4  Grading ................................................................................................................................ 12  7.5  Controlled Low Strength Material (CLSM) ......................................................................... 14  7.6  Foundation Design - General ............................................................................................... 15  7.7  Conventional Foundation Design ........................................................................................ 16  7.8  Mat Foundation Design........................................................................................................ 16  7.9  Miscellaneous Foundations .................................................................................................. 17  7.10  Foundation Settlement ......................................................................................................... 18  7.11  Lateral Design ...................................................................................................................... 18  7.12  Concrete Slabs-on-Grade ..................................................................................................... 19  7.13  Retaining Walls .................................................................................................................... 20  7.14  Dynamic (Seismic) Lateral Forces ....................................................................................... 22  7.15  Retaining Wall Drainage ...................................................................................................... 23  7.16  Elevator Pit Design .............................................................................................................. 24  7.17  Elevator Piston ..................................................................................................................... 24  7.18  Temporary Excavations ....................................................................................................... 25  7.19  Shoring – Soldier Pile Design and Installation & Underpinning ......................................... 25  7.20  Tie-Back Anchors ................................................................................................................ 31  7.21  Anchor Installation............................................................................................................... 31  7.22  Anchor Testing .................................................................................................................... 32  7.23  Internal Bracing ................................................................................................................... 32  7.24  Stormwater Infiltration ......................................................................................................... 33  7.25  Surface Drainage .................................................................................................................. 33  7.26  Plan Review ......................................................................................................................... 34 TABLE OF CONTENTS (Continued) LIMITATIONS AND UNIFORMITY OF CONDITIONS LIST OF REFERENCES MAPS, TABLES, AND ILLUSTRATIONS Figure 1, Vicinity Map Figure 2, Site Plan Figure 3, Cross Sections Figure 4, Regional Fault Map Figure 5, Regional Seismicity Map Figure 6, Retaining Wall Pressure Calculation Figures 7 and 8, Retaining Wall Drain Details Figure 9, Shoring Pressure Calculation APPENDIX A FIELD INVESTIGATION Figures A1 through A3, Boring Logs APPENDIX B LABORATORY TESTING Figures B1 and B2, Direct Shear Test Results Figures B3 through B6, Consolidation Test Results Figure B7, Laboratory Test Results Figure B8, Corrosivity Test Results UPDATED GEOTECHNICAL INVESTIGATION 1. PURPOSE AND SCOPE This report presents the results of an updated geotechnical investigation for the proposed mixed-use development to be located at 5732, 5740, 5750, 5756, 5762, and 5766 West Hollywood Boulevard in the City of Los Angeles, California (see Vicinity Map, Figure 1). The purpose of the investigation was to evaluate subsurface soil and geologic conditions underlying the property and based on conditions encountered to provide conclusions and recommendations pertaining to the geotechnical aspects of proposed design and construction. The scope of our investigation included a site reconnaissance, field exploration, laboratory testing, engineering analysis, and the preparation of this report. The site was explored on August 31, 2012, by excavating three 8-inch diameter borings utilizing a hollow-stem auger drilling machine. The borings were advanced to depths between 30½ and 40½ feet below the existing ground surface. The approximate locations of the borings are depicted on Figure 2, Site Plan. A detailed discussion of the field exploration, including boring logs, is presented in Appendix A. Laboratory tests were performed on selected soil samples obtained during the investigation to determine pertinent physical and chemical soil properties. Appendix B presents a summary of the laboratory test results. The recommendations presented herein are based on analysis of the data obtained during the investigation and our experience with similar soil and geologic conditions. References reviewed to prepare this report are provided in the List of References section. If project details vary significantly from those described below, Geocon should be contacted to determine the necessity for review and possible revision of this report. 2. SITE CONDITIONS & PROJECT DESCRIPTION The subject site is located at located at 5732, 5740, 5750, 5756, 5762, and 5766 West Hollywood Boulevard in the City of Los Angeles, California. The property is an approximately 37,625 square-foot rectangular parcel and is currently occupied by a split level one- and two-story on-grade commercial structure, a single-story on-grade commercial structure, and an associated paved parking lot. The site is bound by West Hollywood Boulevard to the north, by an on-grade four-story mixed-use development to the east, by an approximately 11-foot-wide alley to the south, and by a single-story on-grade commercial structure and associated paved parking lot to the west. The subject property is roughly level with no significant highs or lows. Surface water drainage at the site appears to be by sheet flow along the existing ground contours to the city streets. Vegetation at the site consists of trees and shrubs located in isolated planter areas. Geocon Project No. A8960-06-01 - 1 - November 12, 2014 Information concerning the proposed development was furnished by the client is preliminary in nature. It is our understanding that the proposed development will consist of a new seven-story mixed-use structure to be constructed over two levels of subterranean parking. It is anticipated that the subterranean levels will extend to depths of approximately 30 feet below the existing ground surface and will encompass the majority of the property. A cross section depicting the proposed building profile and subterranean levels is provided as Figure 3. Due to the preliminary nature of the design at this time, wall and column loads were not made available. It is estimated that column loads for the proposed structure may be up to 900 kips. Wall loads are estimated to be up to 10 kips per linear foot. These assumed loading configurations should be confirmed by the project structural engineer as the design progresses. Once the design phase and foundation loading configuration proceed to a more finalized plan, the recommendations within this report should be reviewed and revised, if necessary. Any changes in the design, location, or elevation of any structure, as outlined in this report, should be reviewed by this office. Geocon West, Inc. should be contacted to determine the necessity for review and possible revision of this report. 3. GEOLOGIC SETTING The site is located along the northern edge of the Los Angeles Basin, a coastal plain between the Santa Monica Mountains to the north, the Puente Hills and Whittier fault to the east, the Palos Verdes Peninsula and Pacific Ocean on the west, and the Santa Ana Mountains and San Joaquin Hills on the south. The Los Angeles Basin is located in the northern portion of the Peninsular Ranges geomorphic province and is a northwest-trending alluviated lowland plain, sometimes called the Coastal Plain of Los Angeles. The basin is underlain by a deep structural depression which has been filled by both marine and continental sedimentary deposits, which are underlain by a basement complex of igneous and metamorphic composition (Yerkes, et al, 1965). Regionally, the site is located within the Peninsular Ranges geomorphic province, near the boundary of the Transverse Ranges geomorphic province. The Peninsular Ranges is characterized by northwest trending structures in contrast to the Transverse Ranges that is characterized by east-west trending structures. The Hollywood Fault Zone is located approximately 725 feet west and 870 feet north of the site and forms the boundary between the two geomorphic provinces. 4. GEOLOGIC MATERIALS Based on our field investigation and published geologic maps of the area, the soils underlying the site consist of undocumented fill over Holocene Age alluvial fan deposits generally consisting of sand, silt and gravel (California Department of Water Resources, 1961; California Division of Mines and Geology [CDMG], 1998). Detailed stratigraphic profiles are provided in the boring logs in Appendix A. The soil and geologic units encountered at the site are discussed below. Geocon Project No. A8960-06-01 - 2 - November 12, 2014 4.1 Artificial Fill Artificial fill was observed in our field explorations to a maximum depth of 3 feet below existing ground surface and generally consists of brown sand with silt, silty sand and sandy silt with varied amounts of construction debris. The artificial fill is characterized as slightly moist and loose to medium dense or firm. The fill is likely the result of past grading and/or construction activities at the site. Deeper fill may exist between excavations and in other portions of the site that were not directly explored. 4.2 Alluvial Fan Deposits The artificial fill materials are underlain by Holocene age alluvial fan deposits generally consisting of unconsolidated dark brown to brown sandy silt and silty sand with lesser amounts of sandy clay and sand. The soils are primarily slightly moist to moist and firm to hard or medium dense and become denser with increased depth. The alluvial fan deposits are derived from the nearby Santa Monica Mountains. 5. GROUNDWATER The historic high groundwater level beneath the site is approximately 85 feet below the existing ground surface (CDMG, 1998). Groundwater information presented in the CDMG document is generated from data collected in the early 1900’s to present. Groundwater was not encountered in our explorations, excavated to a maximum depth of 40½ feet beneath the existing ground surface. Based on these considerations, groundwater is neither expected to be encountered during construction, nor have a detrimental effect on the project. However, it is not uncommon for groundwater levels to vary seasonally or for groundwater seepage conditions to develop where none previously existed, especially in impermeable fine-grained soils which are heavily irrigated or after seasonal rainfall. In addition, recent requirements for stormwater infiltration could result in shallower seepage conditions in the immediate site vicinity. Proper surface drainage of irrigation and precipitation will be critical for future performance of the project. Recommendations for drainage are provided in the Surface Drainage section of this report (see Section 7.29). 6. GEOLOGIC HAZARDS 6.1 Surface Fault Rupture The numerous faults in Southern California include active, potentially active, and inactive faults. The criteria for these major groups are based on criteria developed by the California Geological Survey (CGS, formerly known as CDMG) for the Alquist-Priolo Earthquake Fault Zone Program (Hart, 2007). By definition, an active fault is one that has had surface displacement within Holocene time (about the last 11,000 years). A potentially active fault has demonstrated surface displacement during Quaternary time (approximately the last 1.6 million years), but has had no known Holocene movement. Faults that have not moved in the last 1.6 million years are considered inactive. Geocon Project No. A8960-06-01 - 3 - November 12, 2014 The site is not within a currently established Alquist-Priolo Earthquake Fault Zone for surface fault rupture hazards. The official Alquist-Priolo Earthquake Fault Zone Map for the Hollywood Quadrangle (CGS, 2014) indicates the closest boundary of the official Alquist-Priolo Earthquake Fault Zone is located approximately 725 feet west and 870 feet north of the site. No active or potentially active faults with the potential for surface fault rupture are known to pass directly beneath the site. Therefore, the potential for surface rupture due to faulting occurring beneath the site during the design life of the proposed development is considered low. The site, however, is located in the seismically active Southern California region, and could be subjected to moderate to strong ground shaking in the event of an earthquake on one of the many active Southern California faults. The faults in the vicinity of the site are shown in Figure 4, Regional Fault Map. The closest splay of the active Hollywood fault is located approximately 1,500 feet north of the site (CGS, 2014). Other nearby active faults are the Raymond Fault, the Verdugo Fault, the Newport-Inglewood Fault Zone and the Santa Monica Fault located approximately 4.2 miles east-northeast, 5.7 miles northeast, 6.1 miles southwest and 6.8 miles west-southwest of the site, respectively (Ziony and Jones, 1989). The active San Andreas Fault zone is located approximately 32 miles northeast of the site. The closest potentially active fault to the site is the MacArthur Park Fault located approximately 0.6 mile south of the site. Other nearby potentially active faults are the Coyote Pass Fault, the Overland Fault and the Charnock Fault located approximately 7.0 miles southeast, 7.4 miles southwest and 8.6 miles southwest of the site, respectively (Ziony and Jones, 1989). Several buried thrust faults, commonly referred to as blind thrusts, underlie the Los Angeles Basin at depth. These faults are not exposed at the ground surface and are typically identified at depths greater than 3.0 kilometers. The October 1, 1987 M 5.9 Whittier Narrows earthquake, and the January 17, 1994 M 6.7 w w Northridge earthquake were a result of movement on the Puente Hills Blind Thrust and the Northridge Thrust, respectively. These thrust faults are not exposed at the surface and do not present a potential surface fault rupture hazard; however, these active features are capable of generating future earthquakes. 6.2 Seismicity As with all of Southern California, the site has experienced historic earthquakes from various regional faults. The seismicity of the region surrounding the site was formulated based on research of an electronic database of earthquake data. The epicenters of recorded earthquakes with magnitudes equal to or greater than 5.0 in the Southern California area are depicted on Figure 5, Regional Seismicity Map. A partial list of moderate to major magnitude earthquakes that have occurred in Southern California within the last 100 years is included in the following table. Geocon Project No. A8960-06-01 - 4 - November 12, 2014

Description:
If project details vary significantly from those described below, of undocumented fill over Holocene Age alluvial fan deposits generally consisting 2014). Other nearby active faults are the Raymond Fault, the Verdugo Fault, the surrounding the site was formulated based on research of an electron
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.