ID:R01 Points:1.00 Difficulty: 0.00 LevelofKnowledge: Low Source: NEW Theplantisoperatingwiththefollowingindications: B21-R612JetPumpTotalFlowRecorder 87.4Mlbs/hr C51-R608ARxPowerAPRM1 100% B31-R621A/BRRMGSETSPEEDCONTROLLERs 73%(controllinginAUTO) Basedontheabovestartingconditionsandassumingnooperatoractioninresponsetothe transient,openingthefieldbreakerfor'A' ReactorRecircPumpwillcauseReactorPowerto lower.Thepowerreductionisdueto_______. A. 'A'ReactorRecircpumpcoastingdownONLY. B. 'A'ReactorRecircPumpcoastingdownPLUSaspeedreductionin'B'Reactor Recircpumpbecauseof#4limiter. C. 'A'ReactorRecircPumpcoastingdownPLUSaspeedreductionin'B'Reactor Recircpumpbecauseof#2and#3limiters. D. 'A'ReactorRecircPumpcoastingdownPLUSaspeedreductionin'B'Reactor Recircpumpbecauseoflimiter#1limiter. Answer: A ILO2015Written Page: 1of220 08September2015 AnswerExplanation: Limiter4istheonlyrunbackthatwouldactuate.Atasettingof75%,itwouldhavenoeffectonthe reductiononflow.ThereforethecoastdownofApumpistheonlythingloweringRxpower. DistractorExplanation: B. ThisanswerisincorrectbecausethesetpointofLimiter#4is75%,thisanswerisplausibleifthe examineeincorrectlythought#4limiterasalowersetpoint. C. ThisanswerisincorrectandbecauseLimiters#2and#3arecutout.Thisanswerisplausibleifthe examineeincorrectlybelieves#2limiterswillenforce. D. ThisanswerisincorrectbecauseLimiter#1isactuactedwhenRRpumpDischargeVlvisnotfull openortotalFW flowislessthan20%.Thisanswerisplausibleiftheexamineeincorrectlybelieves flowwouldlowerduetolimiterenforcement. ReferenceInformation: 23.138.01Section1.0Description(Limiter#2,#3,#4onpage8)-explainslimiters PlantProcedures 23.138.01 NUREG1123KACatalogRev.2 295001AK3. KnowledgeofthereasonsforthefollowingresponsesastheyapplytoPARTIALOR COMPLETELOSSOFFORCEDCOREFLOW CIRCULATION: 295001AK3.02 Reactorpowerresponse 10CFR55RO/SROWrittenExamContent 10CFR55.41(b)(10) Administrative,normal,abnormal,andemergencyoperatingproceduresfor thefacility. NRCExamUsage ILO2015Exam ILO2015Written Page: 2of220 08September2015 ID:R02 Points:1.00 Difficulty: 0.00 LevelofKnowledge: Low Source: NEW Followingalossof120kVandareactorSCRAM,thefollowingindicationsexistonpanelH11- P809: BreakerPositions • BUS64BPOSB8 CLOSED • BUS64BPOSB6 TRIPPED • BUS11EAPOSEA3 CLOSED • BUS12EBPOSEB3 OPEN • BUS64CPOSC8 CLOSED • BUS64CPOSC6 TRIPPED Basedontheseindications(1)whateventhasoccurred,and(2)whatactionsshouldthe operatingcrewtakeinadditiontoenteringAOP20.300.120kV? A. (1)BuslockoutonBUS64B (2)Perform20.300.72B,LossOfBus72BONLY. B. (1)BuslockoutonBUS64C (2)Perform20.300.72C,LossOfBus72CONLY. C. (1)EDG12failureduetoafaultwithEDG12 (2)Perform20.307.01,EmergencyDieselGeneratorFailureAND20.300.72C, LossOfBus72C. D. (1)EDG11failureduetoafaultwithEDG11 (2)Perform20.307.01,EmergencyDieselGeneratorFailureAND20.300.72B, LossOfBus72B. Answer: C ILO2015Written Page: 3of220 08September2015 AnswerExplanation: 20.300.120kVdirects20.307.01and20.300.72CiftheEDG12outputbreakerfailstoclose (ConditionK). Additionally,nobuslockoutisindicatedso20.307.01wouldbeeffectiveifthecauseoftheEDGfailureis correctable. DistracterExplanation: A. Isincorrectandplausiblebecausethereisnoindicationofa64BBUSLOCKOUT(indicatedbyBUS isolation).Iftherewasa64BBUSLOCKOUT,entering20.300.72Bwouldbecorrect. B. Isincorrectandplausiblebecausetherethereisnoindicationofa64CBUSLOCKOUT(indicatedby BUSisolation).Iftherewasa64CBUSLOCKOUT,entering20.300.72Cwouldbecorrect. D. IsincorrectandplausiblebecausetheBUS11EAPOSEA3isCLOSEDsoEDG11hasstartedand loaded.IfEDG11hadfailedthen20.307.01and20.300.72Bwouldbecorrect. ReferenceInformation: 20.300.120kv,page9,ConditionK. PlantProcedures 20.300.120kv NUREG1123KACatalogRev.2 295003AA1. Abilitytooperateand/ormonitorthefollowingastheyapplytoPARTIALOR COMPLETELOSSOFA.C.POWER: 295003AA1.02Emergencygenerators 10CFR55RO/SROWrittenExamContent 10CFR55.41(b)(10) Administrative,normal,abnormal,andemergencyoperatingproceduresfor thefacility. NRCExamUsage ILO2015Exam ILO2015Written Page: 4of220 08September2015 ID:R03 Points:1.00 Difficulty: 3.00 LevelofKnowledge: High Source: NEW-CONTRACT At1030,alossofoffsitepoweroccurred.AOP20.300.Offsite,LossofOffsitePower,isbeing implementedtomitigatetheelectricalsystemevent. At1145(currenttime),electricalsystemindicationsandconditionsareasfollows: • AllEDGsarerunningloaded. • 120kVand345kVswitchyardcomponentsaredamagedandarebeingevaluatedby personnelforrestoration. • 10D72BOP260/130VBATTERY2PCTROUBLEisinalarm. • 9D17DIVIESS130VBATTERY2PATROUBLEalarmedbutisnowclear. • 10D68DIVIIESS130VBATTERY2PBTROUBLEalarmedbutisnowclear. Iftheelectricalsystemisoperatingwithinitsdesignbases,basedontheindications,(1)whatis thestatusofthestationbatteriesand(2)whatistheirabilitytosupplyloadsduringtheevent? A. (1) Battery2PCisbelowminimumcellvoltage,BOPloadsarede-energized. (2) Batteries2PAand2PBareaboveminimumcellvoltage,ESFloadsare suppliedadequatepowertooperate. B. (1) Battery2PCisaboveminimumcellvoltage,BOPloadsaresupplied adequatepowertooperate. (2) Batteries2PAand2PBareaboveminimumcellvoltage,ESFloadsare suppliedadequatepowertooperate. C. (1) Battery2PCisaboveminimumcellvoltage,BOPloadsshouldbestripped inordertosupplyadequatepowertoremainingloads. (2) Batteries2PAand2PBareaboveminimumcellvoltage,ESFloadsare suppliedadequatepowertooperate. D. (1) Battery2PCisbelowminimumcellvoltage,BOPloadsshouldbestrippedin ordertosupplyadequatepowertoremainingloads. (2) Batteries2PAand2PBarebelowminimumcellvoltage,ESFloadsshould bestrippedinordertosupplyadequatepowertoremainingloads. Answer: C ILO2015Written Page: 5of220 08September2015 AnswerExplanation: BasedonthedesignoftheBOPbatteries,underloadedconditionsthebatteriescansupplyloadsforupto 90minutesbeforefallingbelowminimumcellvoltagewithnochargeravailable.Basedontheconditions ofthe120kvswitchyard,currentlynoBOPchargerisavailable.TheprocedurerequiresstrippingtheDC BOPbussesafteronehouriftheDCBOPchargersremainunavailable.Thisistoretainthebatteries availableforDCcontrolpoweruseupto4hours.ESFbatteriesarefullyavailablewithchargersenergized duetotheEDGpowerbeingavailable.AlarmsindicatebatterychargersareinservicefortheESF batteriesasdirectedbytheprocedure. DistracterExplanation: A. IsincorrectandplausiblebecausetheexamineecouldincorrectlyinterprettheBOPbatterytrouble alarmasalossofthebatteryvoltage.Thevoltagealarmisabovetheminimumcellvoltage.This wouldalsobesupportedbytheindicationthatoffsitepowercannotberestored.ESFchargersare energizedasindicatedbythealarmstatuswhichalsoenhancestheplausibilityofthedistracter. B. IsincorrectandplausiblebecausetheexamineecouldincorrectlyinterpretthatsinceEDGpoweris availableallavailablebatterychargersbothESFandBOPareenergized.ESFchargersareenergized asindicatedbythealarmstatuswhichalsoenhancestheplausibilityofthedistracter. D. Isincorrectandplausiblebecausetheexamineecouldincorrectlyinterprettheindicationand applicationoftheknowledgeofthedesignbasisof1.5hourstotheBOPbatteryandconcludethat sinceonehourhaspassedwithoutstrippingtheBOPbattery,thatthecellsarebelowminimum voltage. ReferenceInformation: R32-00DCELECTRICALSYSTEMDBDpages26-27CriteriaforBOPbatteries PlantProcedures 20.300.Offsite R32-00DESIGNBASISDOCUMENTFORDCELECTRICALSYSTEM NUREG1123KACatalogRev.2 295004AA2. Abilitytodetermineand/orinterpretthefollowingastheyapplytoPARTIALOR COMPLETELOSSOFD.C.POWER: 295004AA2.03 Batteryvoltage 10CFR55RO/SROWrittenExamContent 10CFR55.41(b)(10) Administrative,normal,abnormal,andemergencyoperatingproceduresfor thefacility. NRCExamUsage ILO2015Exam ILO2015Written Page: 6of220 08September2015 ID:R04 Points:1.00 Difficulty: 3.00 LevelofKnowledge: Low Source: BANK:802-2003-0006-008 Withtheplantoperatingat90%power,aFeedwaterControllerFailure-MaximumDemand occurs.Automaticprotectionfromthistransientisassuredbyascramgeneratedasaresultof ________. A. OPRM-Upscaledirectscram,whichpreventsexceedingtheMCPRSafety Limit B. ReactorWaterLevelHigh-Level8MainTurbineTripindirectscram,which preventsexceedingtheMCPRSafetyLimit C. ReactorVesselSteamDomePressure-Highdirectscram,whichprevents exceedingtheReactorCoolantSystemPressureSafetyLimit D. APRMSimulatedThermalPowerUpscaledirectscram,whichprevents exceedingtheReactorCoolantSystemPressureSafetyLimit Answer: B ILO2015Written Page: 7of220 08September2015 AnswerExplanation: Thefeedwaterandmainturbinehighwaterleveltripinstrumentationisassumedtobecapableof providingaturbinetripinthedesignbasistransientanalysisforafeedwatercontrollerfailure,maximum demandevent. TheLevel8tripindirectlyinitiatesareactorscram(above30%RTP)fromthemain turbinetripandtripsthefeedwaterpumps,therebyterminatingtheevent. Thereactorscrammitigatesthe reductioninMCPR. DistracterExplanation: A. Thisisplausibleandincorrectbecausethisprotectsagainstthermalhydraulicpoweroscillations. C. Thisisplausibleandincorrectbecausethisprotectsagainstanyeventthatresultinareactorpressure increase. D. Thisisplausibleandincorrectbecausethisprovidesprotectionagainstalossoffeedwaterheating andensurestheMCPRSLisnotexceeded. ReferenceInformation: ForthisquestiontheT.S.B.isusedasareferenceforsysteminformationthatistaughtinthesystems courseunderlessonplanLP-315-0127pertrainingobjectiveC013: C013. DescribetheReactorProtectionsystemtechnicalspecificationlimitingconditionsforoperation, theirbases,theassociatedsurveillancerequirement(s),andtheirrelationshiptooperability. T.S.B.3.3.2.2(pg3.3.2.2-2)APPLICABLESAFETYANALYSES NUREG1123KACatalogRev.2 G2.2.38 Knowledgeofconditionsandlimitationsinthefacilitylicense. 295005AK1 Knowledgeoftheoperationalimplicationsofthefollowingconceptsastheyapplyto MAINTURBINEGENERATORTRIP: 295005AK1.02 Corethermallimitconsiderations. TechnicalSpecifications 3.3.2.2 FeedwaterandMainTurbineHighWaterLevelTripInstrumentation 10CFR55RO/SROWrittenExamContent 10CFR55.41(b)(5) Facilityoperatingcharacteristicsduringsteadystateandtransientconditions, includingcoolantchemistry,causesandeffectsoftemperature,pressureand reactivitychanges,effectsofloadchanges,andoperatinglimitationsand reasonsfortheseoperatingcharacteristics. NRCExamUsage ILO2015Exam ILO2015Written Page: 8of220 08September2015 ID:R05 Points:1.00 Difficulty: 3.50 LevelofKnowledge: High Source: BANK:315-0048-A018-001 Theplantwasoperatingat15%powerduringastartup.Duetoanelectricalmalfunction,ALL TurbineControlValvesopened resultinginaReactorScram.Nooperatoractionshavebeen taken. InadditiontoSafetyReliefValves,whichoneofthefollowingliststhesystemsavailableforDecay HeatRemovalIMMEDIATELYfollowingthescram? A. ReactorWaterCleanupONLY. B. TurbineBypassValvesandReactorWaterCleanupONLY. C. MainSteamLineDrainValvesandTurbineBypassValvesONLY. D. MainSteamLineDrainValves,TurbineBypassValvesandReactorWater Cleanup. Answer: A ILO2015Written Page: 9of220 08September2015 AnswerExplanation: Withpowerat15%,theModeSwitchisinRUN.TCVsopeninglowersRPVPressure.Whenpressure reaches756psigwithModeSwitchinRUN,aGP1PCISisolationoccursandaScram.WithMSIVs closed,onlySRVsandRWCUareimmediatelyavailabletoremovedecayheat. DistracterExplanation: B. IsincorrectandplausiblebecauseTurbineBypassValvesarenotavailable. C. IsincorrectandplausiblebecauseTurbineBypassValvesandMSLDrainsarenotavailable. D. IsincorrectandplausiblebecauseTurbineBypassValvesandMSLDrainsarenotavailable. ReferenceInformation: 23.601MainSteamLinePressure-Low 23.601MainSteamLineIsolationValve-ClosureLimitSwitches 20.000.21BasesModeSwitchinterlocks PlantProcedures 20.000.21 20.000.21Bases NUREG1123KACatalogRev.2 295006AK1. Knowledgeoftheoperationalimplicationsofthefollowingconceptsastheyapplyto SCRAM: 295006AK1.01 Decayheatgenerationandremoval 10CFR55RO/SROWrittenExamContent 10CFR55.41(b)(10) Administrative,normal,abnormal,andemergencyoperatingproceduresfor thefacility. NRCExamUsage ILO2015Exam ILO2015Written Page: 10of220 08September2015
Description: