ebook img

technical specification sheet PDF

29 Pages·2016·4.01 MB·English
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview technical specification sheet

HALTON AHU TECHNICAL SPECIFICATION SHEET Software Version: HALTON-AHU 2.20.01 Page Number: 1 of 3 PROJECT SUMMARY Project Reference Client Unit Reference Unit Duty 26885 Rev A Blue Vent Design Ltd AHU 1 2.7 m3/s Project Number Date Unit Model Chelsea Arts Club 07/11/2016 Aerolys UNIT CONSTRUCTION Panel Thickness Panel Insulation Aluminium Framework Unit Location 47.00 mm High Density Infill - 50mm 50mm Aluminium Corner Internal Tube (B-Type) Panel External Sheet Panel Internal Sheet Base Frame Reinforced Floor Solent Blue Plastisol Steel Natural Galvanised Steel 20g 100mm High Channel Base - None 20g (1.0mm) (1.0mm) 3mm Sheet Steel Access Side Unit Size Roof Type Right Size 04 None SECTION DIMENSIONS & WEIGHTS Section No. Length Width Height Weight A 1300mm 1330mm 1450mm 304 kg B 275mm 1330mm 1450mm 84 kg C 940mm 1330mm 1450mm 176 kg D 275mm 1330mm 1450mm 87 kg E 1560mm 1330mm 1450mm 1229 kg OVERALL AHU DIMENSIONS & CENTRE OF GRAVITY Length Width Height Weight COG X 4350mm 1330mm 1450mm 1880 Kg 2417mm POLLUSTOP CONTAMINANT REMOVAL The following table highlights the airborne contamination that the POLLUSTOP AHU is designed to remove from the airstream. Please note: This table highlights the capability of the AHU only, and does not include for air treatment external to the unit, for example UV-C Equipped Canopies. SMOKE GREASE COOKING ODOURS SURPLUS OZONE VAPOUR / MOISTURE MODULE 001 SOUND ATTENUATOR (SA) AEROLYS Built-in attenuator modules are available for both Pollustop and Aerolys AHU’s, with the option of melinex lined splitters for polluted airstreams. The attenuator is intended for the reduction of in-duct noise transmission and is available in standard module lengths of 900mm, 1200mm or 1500mm. For specific sound power level requirements, consider seeking suitably qualified acoustic consultants. Type Splitter Thickness Air Velocity Length of Splitter AHU Mounted 200mm 5.23 1200 Air Pressure Drop Splitter Insulation Splitter Face 19.00 Mineral Wool Standard ATTENUATOR ACOUSTIC DATA AT INLET SPIGOT Combined Description 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Level Fan Sound Power (dBW) 80 77 74 73 69 66 66 Attenuator Noise Reduction -16 -25 -40 -54 -48 -45 -31 Resultant Spectrum At Spigot (dB) 64 52 34 19 21 21 35 HALTON AHU TECHNICAL SPECIFICATION SHEET Software Version: HALTON-AHU 2.20.01 Page Number: 2 of 3 PROJECT SUMMARY Project Reference Client Unit Reference Unit Duty 26885 Rev A Blue Vent Design Ltd AHU 1 2.7 m3/s Project Number Date Unit Model Chelsea Arts Club 07/11/2016 Aerolys MODULE 002 HOT WATER HEATING COIL (HW) AEROLYS A copper pipework coil complete with aluminium fins, this unit can be used as a frost and / or duty coil. Generally assumed that a suitable LPHW (low pressure hot water) supply is available on site. Matching 3-way modulating valve available if required as an additional extra. Coil manufactured in accordance with EN 1886:2007. Volume Air ON Coil Db Air OFF Coil Db Duty 2.7m3/s -5.0°C 2.0°C 22.91 kW Face Velocity Flow (Inlet) Temperature Return (Outlet) Temperature Fluid Medium 2.96m/s 80.0°C 70.0°C Water Flow Rate Fluid Pressure Drop Rows / Fins Number of Sections 0.56 l/s 13.96 KPa 1 Rows /4.00 Fins 1 Construction Air Pressure Drop Coil Connections (Inlet / Outlet) CU/AL-0.11 12 Pa ¾” / ¾” MODULE 002 ACCESS DOOR Dimension Type 175 x 1250mm Coil Panel MODULE 003 PANEL (PM) & BAG FILTER (BU) AEROLYS Panel (PM) Filter - a M5 (EU5) grade synthetic glass fibre, high efficiency pleated filter selected to remove medium / fine sized particles. Performance levels up to 97% efficiency for 5 micron particles and above. The filter is 100% incinerable. Bag (BU) Filter - a F7 (EU7) grade glass fibre and broad spectrum media bag filter complete with 10no long pockets. Filter is selected to remove fine particles with performance levels up to 88% efficient for 0.4 micron particles and above. All filters are manufactured in accordance with EN 1886:2007. Pressure Drop Velocity Type Grade Withdrawal Qty / Size 1 Qty / Size 2 Length (Clean/Mean/Dirty) 1.93m/s Panel (PM) Filter M5 Side 4 / 592x592 100mm 42/146/250 Pa 1.93m/s Bag (BU) Filter F7 Side 4 / 592x592 640mm 57/154/250 Pa MODULE 003 ACCESSORIES Fitted Touch Screen MODULE 003 ACCESS DOOR Dimension Type 430 x 1250mm Hinged door MODULE 004 HOT WATER HEATING COIL (HW) AEROLYS A copper pipework coil complete with aluminium fins, this unit can be used as a frost and / or duty coil. Generally assumed that a suitable LPHW (low pressure hot water) supply is available on site. Matching 3-way modulating valve available if required as an additional extra. Coil manufactured in accordance with EN 1886:2007. Volume Air ON Coil Db Air OFF Coil Db Duty 2.7m3/s -2.0°C 12.0°C 45.82 kW Face Velocity Flow (Inlet) Temperature Return (Outlet) Temperature Fluid Medium 2.96m/s 80.0°C 70.0°C Water Flow Rate Fluid Pressure Drop Rows / Fins Number of Sections 1.12 l/s 9.94 KPa 1 Rows /3.00 Fins 1 Construction Air Pressure Drop Coil Connections (Inlet / Outlet) CU/AL-0.11 16 Pa 1 ¼” / 1 ¼” MODULE 004 ACCESS DOOR Dimension Type 175 x 1250mm Coil Panel HALTON AHU TECHNICAL SPECIFICATION SHEET Software Version: HALTON-AHU 2.20.01 Page Number: 3 of 3 PROJECT SUMMARY Project Reference Client Unit Reference Unit Duty 26885 Rev A Blue Vent Design Ltd AHU 1 2.7 m3/s Project Number Date Unit Model Chelsea Arts Club 07/11/2016 Aerolys MODULE 005 PLENUM FAN (FS) AEROLYS A high efficiency direct drive fan unit manufactured with first class dynamic balancing (lowest vibrations) for the longest life cycle possible. Fan temperature rating up to 40°C, capable of a total system static pressure up to 2000 Pa. Fan supplied with variable frequency drive controls. Fan Type Wheel Type Drive Type Plenum Backward Curve DirectDrive Model Impeller Absolute Power Diameter ER56C-4DN.F7.CR- 560 mm 3.69 kW 130571/2Z01 Quantity Duty % Per Fan Poles 1 Single Fan 4 Air Flow Volume Outlet Velocity Motor Speed @ 50Hz 2.7 m3/s 1.8 m/s 1450 rpm External Static Fan & Motor Power Pressure Speed 500 Pa 1566 rpm @ 4.00 kW 54Hz Internal Static Static Efficiency Full Load Current Pressure 394 Pa 61.92% 8.30 A Fan Total Pressure VSD Volts / Ph / Hz 894 Pa Inverter 380/3/50 125 1k Frequency 250 Hz 500 Hz 2k Hz 4k Hz 8k Hz Hz Hz Inlet (1) 79.7 77.2 73.8 73.5 69.2 65.7 65.5 Outlet (2) 85.3 82.9 83.5 82.7 75.1 71.4 69.1 (1) SWL INSIDE The Inlet Duct (dB) (2) SWL INSIDE The Outlet Duct (dB) MODULE 005 ACCESS DOOR Dimension Type 780 x 1250mm Hinged door AHU ACOUSTIC DATA Combined Description 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Level Fan Sound Power (dBW) 85 83 84 83 75 71 69 Casework Attenuation -10 -13 -17 -31 -32 -33 -36 Reduction @ 3m Distance (dB) -14 -14 -14 -14 -14 -14 -14 Resultant Spectrum (dB) 61 56 53 38 29 24 19 A-Weighted Resultant Spectrum 45 47 49 38 30 25 18 (dBA) AHU SPECIFIC FAN POWER (SFP) Specific Fan Power (SFP) is a parameter that quantifies the energy-efficiency of fan air movement systems. It is a measure of the electric power that is needed to drive a fan (or collection of fans), relative to the amount of air that is circulated through the fan(s). It is not constant for a given fan, but changes with both air flow rate and fan pressure rise. Filter Conditions Absorbed Power Drive Efficiency Inverter Efficiency Motor Efficiency Air Volume Clean 2.83 Kw 100% 98% 100% 2.7 m3/s SPECIFIC FAN POWER 1.07 kW/m3/s • Up to 120°C medium temperature, continuous operation • Multi-functional use, e.g. for kitchen exhaust air • Modular system • Pre-assembled isolator is standard • Low sound level • Easy to maintain and reliable • High efficient IE2 motors • Speed-controllable via frequency converter • Motor outside the air stream All MUB/T fans have impellers with backward curved blades, manufactured from aluminium, and IEC standard motors outside the air stream with efficiency class IE2 for all 400V three phase motors from 0.75 kW. The MUB/T fans are suitable for medium temperatures up to 120°C continuously. Motor protection by cold conductors or thermal contact, to be connected to an external motor protection device. The casing consists of an aluminium frame with fibreglass reinforced plastic corners and double skin, galvanised steel panels with a 20 mm mineral wool insulation. Panels are removable, allowing flexible ventilation solutions - the air direction can easily be changed. With quick lock access door. The MUB bottom panel is shaped as a grease tray and incorporates a pre-mounted 1" drain plug. An isolator switch is mounted on the casing. Several filter modules like f.e. activated carbon- or aluminum filters are available, calculated individually on the working point. Please note: Speed controll by voltage, i.e. voltage transformers, is not possible! In accordance with Commission Regulation (EC) no 640/2009 of the European Parliament - eco-design requirements for electric motors - the new international efficiency classes are binding as of 16 June 2011. These guidelines defined by CEMEP and EPACT are regarded as international standard for energy-saving high-efficiency motors for frequencies of 50 or 60 Hz and make the use of IE2 motors mandatory. With this new and more efficient technology we offer our customers many advantages such as environmentally friendly operation, reduced energy consumption and hence lower emissions. IE2 motors have a higher efficiency even in part load operation and allow optimum adjustment to the operating point. In addition, the IE2 motors generate less noise and develop less heat, which has a positive influence on the efficiency and the cooling requirement of the motor. Please note: IE2 motors cannot be speed controlled by voltage, i.e. voltage transformers. QTY Check availability In stock Sent earliest Show availability Hide availability Date Qty Verify delivery possibility Enter the date and number on the right to check stock and delivery possibility of the product. MUB/T 025 355DV(/en-GB/UK/Products/fans--accessories/rectangular--square-duct- fans/thermo-multibox/mubt/MUBT-025-355DV/) MUB/T 025 355E4(/en-GB/UK/Products/fans--accessories/rectangular--square-duct- fans/thermo-multibox/mubt/MUBT-025-355E4/) MUB/T 042 400DV(/en-GB/UK/Products/fans--accessories/rectangular--square-duct- fans/thermo-multibox/mubt/MUBT-042-400DV/) MUB/T 042 400E4(/en-GB/UK/Products/fans--accessories/rectangular--square-duct- fans/thermo-multibox/mubt/MUBT-042-400E4/) Diagram Technical parameters Dimension Wiring Acoustics Specification Documents Accessories Products in the same series Technical parameters Diagram Input data Air flow 3 m³/s  Static pressure 600 Pa  Selection method System line  Diagrams Hydraulic data Required point Working point Q Ps Q Ps P n I SFP U [m³/s] [Pa] [m³/s] [Pa] [W] [r.p.m.] [A] [W/(l/s)] [V] Max efficiency 2,39 923 4426 1463 7,71 1,85 400 User 3 600 3,09 637 4472 1459 7,79 1,45 400 Dimension Wiring Acoustics

Description:
Software Version: HALTON-AHU 2.20.01 Built-in attenuator modules are available for both Pollustop and Aerolys AHU's, with the option of melinex lined splitters for polluted airstreams. If the Buyer fails to take delivery, or fails to give the Seller adequate delivery instructions, the Seller may i
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.