ebook img

Supplement No. 1 to AISC 358-16 Prequalified Connections for Special and Intermediate Steel ... PDF

63 Pages·2017·3.26 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview Supplement No. 1 to AISC 358-16 Prequalified Connections for Special and Intermediate Steel ...

1 1 DRAFT AISC 358-16s1 2 3 Supplement No. 1 4 to AISC 358-16 5 Prequalified Connections 6 for Special and Intermediate 7 Steel Moment Frames for 8 Seismic Applications 9 10 11 12 13 Draft Dated August 30, 2017 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 AMERICAN INSTITUTE OF STEEL CONSTRUCTION 34 130 East Randolph Street, Suite 2000 35 Chicago, Illinois 60601 36 Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 2 37 AISC © 201X 38 39 by 40 41 American Institute of Steel Construction 42 43 All rights reserved. This book or any part thereof 44 must not be reproduced in any form without the 45 written permission of the publisher. 46 47 The AISC logo is a registered trademark of AISC. 48 49 The information presented in this publication has been prepared by a balanced committee following American 50 National Standards Institute (ANSI) consensus procedures and recognized principles of design and construction. 51 While it is believed to be accurate, this information should not be used or relied upon for any specific application 52 without competent professional examination and verification of its accuracy, suitability and applicability by a 53 licensed engineer or architect. The publication of this information is not a representation or warranty on the part of 54 the American Institute of Steel Construction, its officers, agents, employees or committee members, or of any other 55 person named herein, that this information is suitable for any general or particular use, or of freedom from 56 infringement of any patent or patents. All representations or warranties, express or implied, other than as stated 57 above, are specifically disclaimed. Anyone making use of the information presented in this publication assumes all 58 liability arising from such use. 59 60 Caution must be exercised when relying upon standards and guidelines developed by other bodies and incorporated 61 by reference herein since such material may be modified or amended from time to time subsequent to the printing of 62 this edition. The American Institute of Steel Construction bears no responsibility for such material other than to refer 63 to it and incorporate it by reference at the time of the initial publication of this edition. 64 65 Printed in the United States of America 66 Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 3 67 68 Table of Contents 69 70 SYMBOLS ..................................................................................................................................................... 4 71 72 CHAPTER 11. SIDEPLATE MOMENT CONNECTION ....................................................................... 6 73 11.1. General ........................................................................................................................................ 6 74 11.2. Systems ..................................................................................................................................... 10 75 11.3. Prequalification Limits .............................................................................................................. 10 76 1. Beam Limitations ...................................................................................................................... 10 77 2. Column Limitations ................................................................................................................... 12 78 3. Connection Limitations ............................................................................................................. 14 79 11.4. Column-Beam Relationship Limitations ................................................................................... 14 80 11.5. Connection Welding Limitations .............................................................................................. 17 81 11.6. Connection Detailing ................................................................................................................. 18 82 1. Plates ......................................................................................................................................... 18 83 2. Welds ......................................................................................................................................... 18 84 3. Bolts .......................................................................................................................................... 23 85 11.7. Design Procedure ...................................................................................................................... 24 86 87 CHAPTER 14. SLOTTEDWEB MOMENT CONNECTION ................................................................ 28 88 89 14.1. General ...................................................................................................................................... 28 90 14.2. Systems ..................................................................................................................................... 29 91 14.3. Prequalification Limits .............................................................................................................. 29 92 1. Beam Limitations ............................................................................................................. 29 93 2. Column Limitations .......................................................................................................... 30 94 14.4. Column-Beam Relationship Limitations ................................................................................... 30 95 14.5. Beam Flange-to-Column Flange Weld Limitations .................................................................. 31 96 14.6. Beam Web and Shear Plate Connection Limitations ................................................................. 31 97 14.7. Fabrication of Beam Web Slots ................................................................................................. 32 98 14.8. Design Procedure ...................................................................................................................... 32 99 COMMENTARY ........................................................................................................................................ 36 100 REFERENCES ............................................................................................................................................ 62 101 102 Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 4 103 SYMBOLS 104 105 This Standard uses the following symbols in addition to the terms defined in the Specification for Structural Steel 106 Buildings (ANSI/AISC 360-16) and the Seismic Provisions for Structural Steel Buildings (ANSI/AISC 341-16). 107 Some definitions in the following list have been simplified in the interest of brevity. In all cases, the definitions given 108 in the body of the Standard govern. Symbols without text definitions, used in only one location and defined at that 109 location, are omitted in some cases. The section or table number on the right refers to where the symbol is first used. 110 111 Symbol Definition Section 112 113 A Perpendicular amplified seismic drag or chord forces transferred through the  114 SidePlate connection, resulting from applicable building code, kips (N) .......................... 11.7 115 A In-plane factored lateral drag or chord axial forces transferred along the frame beam || 116 through the SidePlate connection, resulting from load case 1.0E per applicable building Q 117 code, kips (N) .................................................................................................................... 11.7 118 C Factor to account for peak connection strength, including strain pr 119 hardening, local restraint, additional reinforcement, and other 120 connection conditions ........................................................................................................ 14.8 121 F Expected yield strength of steel beam, ksi (MPa) .............................................................. 14.8 ye 122 F Specified minimum yield stress of the yielding element, ksi (MPa) ................................. 14.8 y 123 H Distance along column height from ¼ of the column depth above the top edge of the lower- h 124 story side plates to ¼ of the column depth below the bottom edge of the upper-story side 125 plates, in. (mm) .................................................................................................................. 11.4 126 I Moment of inertia of the beam in the plane of bending, in.4 (mm4) .................... Figure 11.16 beam 127 I Approximation of moment of inertia due to beam hinge location and side plate stiffness, total 128 in.4 (mm4) ............................................................................................................ Figure 11.16 129 M Factored gravity moments from cantilever beams that are not in the plane of the moment cant 130 frame but are connected to the exterior face of the side plates, resulting from code- 131 applicable load combinations, kip-in. (N-mm). ................................................................. 11.7 132 M Probable maximum moment at face of the column, kip-in. (N-mm) ................................. 14.8 f 133 M Maximum probable moment demand at any connection element, kip-in. (N-mm) ........... 11.7 group 134 M Probable maximum moment at the plastic hinge, kip-in. (N-mm) ................................... 14.4 pr 135 M* Projection of the expected flexural strength of the beam as defined in the AISC Seismic pb 136 Provisions, kip-in. (N-mm)................................................................................................ 14.4 137 M Additional moment due to shear amplification from the plastic hinge, kip-in. (N-mm).... 14.4 uv 138 M Moment resisted by the shear plate, kip-in. (N-mm) ......................................................... 14.8 weld 139 R Ratio of the expected yield stress to the specified minimum yield stress, F, as specified in y y 140 the AISC Seismic Provisions ............................................................................................ 14.8 141 T Beam web height as given in the AISC Manual, in. (mm) ................................................ 14.8 142 V Shear at beam plastic hinge, kips (N) ................................................................................ 14.4 beam Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 5 143 V Factored gravity shear forces from cantilever beams that are not in the plane of the moment cant 144 frame but are connected to the exterior face of the side plates, resulting from code- 145 applicable load combinations, kips (N) ............................................................................. 11.7 146 V Beam shear force resulting from the load combination 1.2D + f L + 0.2S, kips (N) ......... 14.8 gravity 1 147 V Shear resisted by the shear plate, kips (N) ......................................................................... 14.8 weld 148 V , V Factored gravity shear forces from gravity beams that are not in the plane of the moment 1 2 149 frame but are connected to the exterior surfaces of the side plate, resulting from the load 150 combination of 1.2D + f L + 0.2S (where f is the load factor determined by the applicable 1 1 151 building code for live loads, but not less than 0.5), kips (N) ............................................. 11.7 152 Z Plastic section modulus of the beam, in.3 (mm3) ............................................................... 14.8 beam 153 Z Equivalent plastic section modulus of the column at a distance of ¼ the column depth ec 154 from the top and bottom edge of the side plates, projected to the beam centerline, 155 in.3 (mm3) ......................................................................................................................... 11.4 156 Z Plastic section modulus of the beam web, in.3 (mm3) ........................................................ 14.8 web 157 Z Plastic modulus of beam about the x-axis, in.3 (mm3) ....................................................... 11.7 xb 158 Z Plastic modulus of column about the x-axis, in.3 (mm3) .................................................... 11.7 xc 159 b Flange width, in. (mm) ...................................................................................................... 14.8 f 160 d Nominal beam depth, in. (mm) .......................................................................................... 14.8 161 d Depth of the column, in. (mm) .......................................................................................... 14.4 col 162 d , d Depth of column on each side of a bay in a moment frame, in. (mm) ............................... 11.3 c1 c2 163 e Eccentricity of the shear plate weld, in. (mm) ................................................................... 14.8 x 164 h Height of shear plate, in. (mm) .......................................................................................... 14.8 165 l Half the clear span length of beam, in. (mm) .................................................................... 14.8 b 166 l Width of shear plate, in. (mm) ........................................................................................... 14.4 p 167 l Beam slot length, in. (mm) ................................................................................................ 14.8 s 168 t Thickness of beam flange, in. (mm) .................................................................................. 14.8 bf 169 t Minimum required shear plate thickness, in. (mm) ........................................................... 14.8 p 170 t Thickness of beam web, in. (mm) ..................................................................................... 14.8 bw 171 x Distance from plastic hinge location to centroid of connection element, 172 in. (mm) ............................................................................................................................. 11.7 Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 6 173 CHAPTER 11 174 SIDEPLATE MOMENT CONNECTION 175 176 The user’s attention is called to the fact that compliance with this chapter of the standard requires 177 use of an invention covered by multiple U.S. and foreign patent rights.* By publication of this 178 standard, no position is taken with respect to the validity of any claim(s) or of any patent rights in 179 connection therewith. The patent holder has filed a statement of willingness to grant a license 180 under these rights on reasonable and nondiscriminatory terms and conditions to applicants 181 desiring to obtain such a license, and the statement may be obtained from the standard’s developer. 182 11.1. GENERAL 183 The SidePlate® moment connection utilizes interconnecting plates to connect beams 184 to columns. The connection features a physical separation, or gap, between the face 185 of the column flange and the end of the beam. Both field-welded and field-bolted 186 options are available. Beams may be either rolled or built-up wide-flange sections or 187 hollow structural sections (HSS). Columns may be either rolled or built-up wide- 188 flange sections, built-up box column sections or HSS for uniaxial configurations. 189 Built-up flanged cruciform sections consisting of rolled shapes or built-up from plates 190 may also be used as the columns for biaxial configurations. Figures 11.1, 11.2, and 191 11.3 show the various field-welded and field-bolted uniaxial connection 192 configurations. The field bolted option is available in two configurations, referred to 193 as Config. A (Standard) and Config. B (Narrow), as shown in Figure 11.3. 194 195 In the field-welded connection, top and bottom beam flange cover plates (rectangular 196 or U-shaped) are used at the end(s) of the beam, as applicable, which also serve to 197 bridge any difference between flange widths of the beam(s) and of the column. The 198 connection of the beam to the column is accomplished with parallel full-depth side 199 plates that sandwich and connect the beam(s) and the column together. In the field- 200 bolted connection, beam flanges are connected to the side plates with either a cover 201 plate or pair of angles and high strength pretensioned bolts as shown in Figures 11.2 202 and 11.3. Column horizontal shear plates and beam vertical shear elements (or shear 203 plates as applicable) are attached to the wide-flange shape column and beam webs, 204 respectively. 205   206 207 * The SidePlate® connection configurations and structures illustrated herein, including their described fabrication and erection methodologies, are protected by one or more of the following U.S. and foreign patents: U.S. Pat. Nos. 5,660,017; 6,138,427; 6,516,583; 6,591,573; 7,178,296; 8,122,671; 8,122,672; 8,146,322; 8,176,706; 8,205,408; Mexico Pat. No. 208,750; New Zealand Pat. No. 300,351; British Pat. No. 2497635; all held by MiTek Holdings LLC. Other U.S. and foreign patent protection are pending. Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 7 (a) (b) (c) (d) (e) (f) 208 Fig. 11.1. Assembled SidePlate uniaxial field-welded configurations: (a) one-sided wide-flange 209 beam and column construction;(b) two-sided wide-flange beam and column construction; (c) 210 wide-flange beam to either HSS or built-up box column; (d) HSS beam without cover plates to 211 wide-flange column; (e) HSS beam with cover plates to wide-flange column; and (f) HSS beam 212 with cover plates to either HSS or built-up box column. 213 214 (a) (b) (c) 215 (d) (e) (f) 216 Fig. 11.2. Assembled SidePlate uniaxial field-bolted Standard configurations (Config. A): (a) 217 one-sided wide-flange beam and column construction; (b) two-sided wide-flange beam and 218 column construction; (c) wide-flange beam to either HSS or built-up box column; (d) HSS beam 219 to wide-flange column; (e) HSS beam with cover plate to wide-flange column; and (f) HSS beam 220 with cover plates to either HSS or built-up box column. Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 8 221 (a) (b) (c) 222 Fig. 11.3. SidePlate field-welded and field bolted connection comparison: (a) a typical field- 223 welded connection; (b) a typical field-bolted Standard connection (Config. A); (c) A typical 224 field-bolted Narrow connection (Config. B). 225 Figure 11.4 shows the connection geometry and major connection components for 226 uniaxial field-welded configurations. Figure 11.5 shows the connection geometry and 227 major connection components for biaxial field-welded configurations, which permits 228 connecting up to four beams to a column. Field bolted connections are also permitted 229 in biaxial configurations. 230 Cover Plate Configurations Plan Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 9 Elevation (a) (b) (c) (d) 231 Fig. 11.4. SidePlate uniaxial configuration geometry and major components: (a) typical wide- 232 flange beam to wide-flange column, detail, plan and elevation views; (b) HSS beam without 233 cover plates to wide-flange column, plan view; (c) HSS beam with cover plates to wide-flange 234 column, plan view; and (d) wide-flange beam to built-up box column, plan view. 235 (a) (b) Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION 10 (c) (d) 236 237 Fig. 11.5. SidePlate biaxial dual-strong axis configurations in plan view: (a) full four-sided 238 wide-flange column configuration; (b) corner two-sided wide-flange column configuration with 239 single WT; (c) tee three-sided wide-flange column configuration with double WT (primary); and 240 (d) tee three-sided wide-flange column configuration with single WT. 241 The SidePlate moment connection is proportioned to develop the probable maximum 242 moment capacity of the connected beam. Plastic hinge formation is intended to occur 243 primarily in the beam beyond the end of the side plates away from the column face, 244 with limited yielding occurring in some of the connection elements. 245 User Note: Moment frames that utilize the SidePlate connection can be constructed 246 using one of three methods. These are the full-length beam erection method 247 (SidePlate FRAME configuration), the link-beam erection method (SidePlate Original 248 configuration), and the fully shop prefabricated method. These methods are described 249 in the commentary. 250 251 11.2. SYSTEMS 252 The SidePlate moment connection is prequalified for use in special moment frame 253 (SMF) and intermediate moment frame (IMF) systems within the limits of these 254 provisions. The SidePlate moment connections are prequalified for use in planar 255 moment-resisting frames and orthogonal intersecting moment-resisting frames 256 (biaxial configurations, capable of connecting up to four beams at a column), as 257 illustrated in Figure 11.5. 258 11.3. PREQUALIFICATION LIMITS 259 1. Beam Limitations 260 Beams shall satisfy the following limitations: 261 262 (1) Beams shall be rolled wide-flange, hollow structural section (HSS), or built-up I- 263 shaped beams conforming to the requirements of Section 2.3. Beam flange 264 thickness shall be limited to a maximum of 2.5 in. (63 mm). 265 (2) Rolled and built-up wide-flange beam depth shall be limited to W40 (W1000) 266 and W44 (W1100) for the field-welded and field-bolted connections, 267 respectively. 268 (3) Beam depths shall be limited as follows for HSS shapes: 269 (a) For SMF systems, HSS14 (HSS 356) or smaller. Draft Dated August 30, 2017 Supplement No. 1 to Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications AMERICAN INSTITUTE OF STEEL CONSTRUCTION

Description:
National Standards Institute (ANSI) consensus procedures and recognized principles of design and construction. 50 Anyone making use of the information presented in this publication assumes all. 57 plate or pair of angles and high strength pretensioned bolts as shown in Figures 11.2. 201.
See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.