CENTRIMASTER GT-1 DIRECT DRIVEN, SINGLE INLET CENTRIFUGAL FANS TECHNICAL CATALOGUE Centrimaster GT-1 - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION .....................................................................................4 ACCESSORIES Versions ...........................................................................................................4 GTLZ-11/GTLZ-12 Flexible connection, inlet ................................. 38 GTLZ-21/GTLZ-22 Flexible connection, outlet ...............................38 GENERAL SURVEY CHARTS ..........................................................................5 GTLZ-24 Counterflange, outlet ........................................................... 38 GTLZ-13/GTLZ-15 Protctive screen, inlet .........................................38 DESIGN DESCRIPTION ........................................................................................6 GTLZ-23/GTLZ-18 Protective screen, outlet ...................................39 GTLZ-32 Inspection cover .....................................................................39 MATERIALS AND FINISH ....................................................................................7 GTLZ-34 Drain .............................................................................................39 MOTOR .......................................................................................................................7 GTLZ-42 Anti vibration mountings, rubber ......................................39 QUALITY & ENVIRONMENT ................................................................................7 GTLZ-50/GTLZ-51 Flow measuring device ....................................39 TOLERANCES ..........................................................................................................7 GTLZ-60 Painted finish ...........................................................................39 GTLZ-77 Motor protection.......................................................................39 FAN CHART EXPLANATION AND DEFINITIONS .........................................8 ACOUSTIC DATA EXPLANATIONS .................................................................9 SPECIFICATION TEXT GTLB-1 ............................................................................................................40 TECHNICAL DATA INCL. DIMENSIONS, MOTOR DATA AND WEIGHTS GTLF-1 ............................................................................................................40 GTLB-1-022 ..................................................................................................10 High Temperature (GTLB-1) ...................................................................40 GTLB-1-025 ...................................................................................................12 ATEX (GTLB-1) .............................................................................................40 GTLB-1-028 ...................................................................................................14 GTLB-1-031 . ................................................................................................16 GTLB-1-035 ...................................................................................................18 IMPORTANT INFORMATION ATEX Directive 94/9/EC .........................................................................41 GTLB-1-040 . ................................................................................................20 GTLB-1-045 ..................................................................................................22 ORDERING CODES ..............................................................................................42 GTLB-1-050 ..................................................................................................24 Accessories ................................................................................................43 GTLB-1-056 ..................................................................................................26 GTLB-1-063 ..................................................................................................28 GTLB-1-071 ...................................................................................................30 GTLF-1-020 ..................................................................................................32 GTLF-1-022 ...................................................................................................34 GTLF-1-025 .................................................................................................36 FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice 4 Centrimaster GT-1 - Technical Catalogue GENERAL DESCRIPTION The CentriMaster GTLB-1 and GTLF-1 are direct driven, single inlet centrifugal fans. The range covers air flows up to 9 m3/s (32 400 m3/h) and pressure rises up to 3 000 Pa with GTLB-1 and up to 1.1 m3/s (3 960 m3/h) and pressure rises up to 1 600 Pa max with GTLF-1. The fan series consists of centrifugal fans available with two types of impeller: • Impeller with backward curved blades for the GTLB fans • Impeller with forward curved blades for the GTLF fans VERSIONS STANDARD VERSION The GTLB-1 and GTLF-1 fans are rated for continuous operation at temperatures up to +80° C if the inlet of the fan is connected to the ducting. If the motor is exposed to the air stream, i.e. on a free inlet fan, the ambient temperature must not exceed +40° C. HIGH TEMPERATURE VERSION The high temperature (HT) version is used for smoke extraction purposes. It has been tested and certified to withstand 400 °C for 2 hours by SP Technical Research Institute of Sweden, conform- ing with the standard EN 12101-3. Only GTLB-1 fans are available as high temperature version. See specification text on page 40. ATEX VERSION Backward curved impeller Forward curved impeller The ATEX version is used in potentially explosive atmospheres according to Directive 2014/34/EU using Ex de motors. Only GTLB-1 fans are available as ATEX version. See specification text on page 40. FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice Centrimaster GT-1 - Technical Catalogue 5 GENERAL SURVEY CHARTS GTLB-1 3500 3000 2500 a) P e ( 2000 ur s s e Pr al ot 1500 T 1000 071 050 056 063 500 035 040 045 031 022025 028 0 0 5000 10000 15000 20000 25000 30000 35000 (m3/h)40000 0 2 4 6 8 10 (m3/s) Volume flow rate GTLF-1 1800 1600 022 1400 1200 020 a) P e ( 1000 ur s s e Pr al 800 ot T 600 400 025 200 0 0 1000 2000 3000 (m3/h) 4000 0 0.2 0.4 0.6 0.8 1.0 (m3/s) Volume flow rate FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice 6 Centrimaster GT-1 - Technical Catalogue DESIGN DESCRIPTION FAN CASING FAN IMPELLERS The fan casing is made of Sendzimir galvanized sheet steel. The The fan impellers with backward curved blades (GTLB) are made casing side plates are deep drawn. Inlet cone for GTLF-1 is a part of welded sheet steel and coated with 60 μm thick epoxy powder of the side plate of the casing whereas the GTLB-1 fans have a (colour RAL 6029 green). separate inlet cone. The fan casing is jointed using Pittsburg fold- The fan impellers with forward curved blades (GTLF) are made of ing method, which produces tight and strong joints. This jointing Sendzimir galvanized sheet steel. method and the deep drawn inlet cone guarantee a stable design and high quality. The cut-off is designed to offer optimized aero- dynamic properties. Fan impeller of the type GTLB fans Fan impeller of the type GTLF fans FAN INLET The fan inlet of a GTLB-1 fan is specially designed to ensure high fan efficiency and low sound level generated by the fan. The inlet cone is deep drawn in one piece and fastened to the side plate of the fan casing. Inlet cone of the GTLF-1 fans is deep drawn in the fan casing. MOTOR BRACKET The ATEX version of GTLB-1 has an inlet cone made of copper. The motor bracket is made of Sendzimir galvanized sheet steel and fastened directly to the fan casing. FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice Centrimaster GT-1 - Technical Catalogue 7 MATERIAL AND FINISH, MOTOR, QUALITY & ENVIRONMENT, TOLERANCES MATERIAL AND FINISH ErP DIRECTIVE RELATED DATA The GT fans meet the environmental class C2 as standard. 250 μm All the product related data is available in the software. The fans painting gives a painting class C5. are ErP 2015 compliant. Fan casing: Sendzimir galvanized sheet steel TOLERANCES Inlet cone: Sendzimir galvanized sheet steel in standard version, copper in the ATEX version The particulars in the charts are given with the tolerance speci- fied in the DIN 24 166 Standard, Class 2 for complete fan. Impeller: GTLB: Welded sheet steel and coated with epoxy powder 60 μm Tolerance class DIN 24 166 1 2 3 GTLF: Sendzimir galvanized steel Air flow q ±2,5 % ±5 % ±10 % v Pressure rise, Δp ±2,5 % ±5 % ±10 % MOTOR f Shaft power1), Pr +3 % +5 % +16 % The motor used in standard and high temperatur (HT) version Efficiency2), ηf –2 % –5 % – is an IEC standard IE3 motor. It is equipped with thermistor as A-weighted sound standard. Motors are designed to be used with a frequency power level1), L +3 dB +4 dB +6 dB WA converter. Degree of protection for the standard motors is IP 54. 1) Negative tolerance permissible See specification text on page 40. 2) Positive tolerance permissible Motors in ATEX-version are flameproof Ex de IIB T4 motors equipped with a surface temperature sensor and can be driven with a speed controller. See specification text on page 40. QUALITY & ENVIRONMENT All components are designed and manufactured in accordance with applicable standards including the quality assurance system ISO 9001, the environmental management system ISO 14001 and the Energy Directive 2009/125/EC and all directives related to CE-marking. FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice 8 Centrimaster GT-1 - Technical Catalogue FAN AND POWER DEMAND CHART EXPLANATIONS, DEFINITIONS FAN CHART EXPLANATIONS SYMBOLS USED ❶ q m3/h The fan charts presented on the following pages are applicable to v 0 1000 2000 3000 4000 5000 air with a density of 1.2 kg/m³. 2800 2600 4500 r/min-3 kW ❸ 75 ❶ 78 ❹ qv Volume flow rate m3/s, m3/h 2400 4240-2,2 79% ❷ Δp Total pressure rise Pa f 2200 4000-ATEX max 78 ❸ Fan max speed curve and motor 2000 3740-1,5 75 nominal power with different motors 1800 ❷ using VSD or synchronous speed Pa)1600 3370-1,1 70 without VSD. p (f1400 Red line, max speed for ∆ 1200 2970-0,75 87 60 ATEX and HT version r/min, kW 1000 2825-2 pole ❹ η Fan total efficiency % 800 2520-0,55 84 ❺ 50 ❺ 2340-0,37 81 LwA Total A-weighted sound power level 600 2050-0,25 90 dB(A) at the discharge side dB(A) 93 400 96 200 3000-HT max 0 0 0,2 0,4 0,6❶ 0,8 1,0 1,2 1,4 1,6 q m3/s v FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice Centrimaster GT-1 - Technical Catalogue 9 ACOUSTIC DATA EXPLANATIONS The total A-weighted sound power level LWA on the outlet side SYMBOLS USED of a fan with ducted inlet and outlet is specified in the fan chart. L A-weighted sound power level emitted to WA Sound power levels at different octave bands and different sound the outlet duct, specified in the fan chart dB(A) paths can be calculated using the following formula: L A-weighted sound power level WA(s) equivalent to sound path s dB(A) L = L + K Woct(s) WA oct(s) L Total sound power level at each octave Woct(s) where K values can be obtained from the table. The following band (without A-weighting, corresponding oct formula can be used for calculating the A-weighted sound power to sound path s) dB level on each sound path: L Total sound power level (without A-weighting, Wt(s) corresponding to sound path s) dB L = L + ΔL WA(s) WA WA(s) K Correction figure for breaking down the oct(s) sound level at each octave (corresponding where the correction figure ΔL can be obtained from the WA(s) to sound path s) dB table. The table also includes correction figures ΔL that can Wt(s) s Sound path be used for obtaining the total sound power level on each sound L Distance m path: L = L + ΔL ΔL Distance absorption (applicable to ideal Wt(s) WA(s) Wt(s) conditions with hemispherical sound propagation) dB SOUND PATHS L A-weighted sound pressure level at pA(s) Sound paths used in the acoustic data tables distance L from fan (corresponding to sound path s) dB(A) Sound path DISTANCE ABSORPTION To outlet duct The following formula is used to obtain the sound pressure level LpA(s) on free sound emission to the surroundings (sound paths 3 and 4) at various distances L: To inlet duct L = L – ΔL pA(s) WA(s) Through the casing where the distance absorption ΔL can be obtained from the table below: L, m 1 3 5 10 15 20 25 30 40 50 75 100 ΔL, dB 8 17 22 28 31 34 36 37 40 42 45 48 To fan outlet (for open discharge fan) SOUND DATA EXAMPLE - GTLB-1-028 Sound path s Min r/min Max r/min Correction (dB) Koct in octave band mid frequency (Hz) LWA(s) – LWA LWt(s) – LWA(s) 63 125 250 500 1000 2000 4000 8000 dB dB 0 1928 1 2 3 –4 –7 –8 –13 –16 0 7.6 To outlet duct 1928 3857 –1 –1 –7 –1 –6 –8 –12 –16 0 4.9 3857 4500 –4 –3 –2 –8 –4 –7 –10 –14 0 3.9 0 1928 1 1 3 –2 –5 –10 –12 –17 0.6 6.9 To inlet duct 1928 3857 –2 –2 –8 0 –4 –10 –11 –17 0.7 4.1 3857 4500 –4 –3 –4 –5 –2 –9 –11 –16 0.5 3.4 0 1928 –7 –5 –4 –9 –12 –14 –21 –31 –6.1 6.7 Through the casing 1928 3857 –9 –8 –10 –8 –12 –15 –23 –35 –6.9 5.0 3857 4500 –13 –12 –8 –14 –8 –15 –21 –33 –6.0 3.1 0 1928 –14 –5 0 –5 –7 –8 –13 –16 –1.1 4.3 To fan outlet (for 1928 3857 –20 –9 –10 –2 –6 –8 –12 –16 –0.5 1.9 open discharge fan) 3857 4500 –24 –12 –5 –9 –4 –7 –10 –14 –0.4 1.4 For information how to calculate sound data, sound pressure level and distance absorption, see page 9. FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice 10 Centrimaster GT-1 - Technical Catalogue GTLB-1-022 - FAN CHARTS, MOTOR DATA DIRECT DRIVEN, SINGLE-INLET, BACKWARD-CURVED BLADES Impeller diameter: 220 mm q m3/h v 0 500 1000 1500 2000 2500 3000 2200 2000 70 5000 r/min-1,1 kW 75 1800 78% 1600 4500-0,75 1400 75 4060-0,55 p (Pa)f1200 70 ∆ 1000 3560-0,37 84 800 60 81 600 2730-2 pole 50 78 2500-0,25 87 dB(A) 400 90 93 200 ATEX: Max speed is 4000 r/min 4000-ATEX max HT: Not available for size 022 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 q m3/s v SOUND DATA Sound path s Min r/min Max r/min Correction (dB) Koct in octave band mid frequency (Hz) LWA(s) – LWA LWt(s) – LWA(s) 63 125 250 500 1000 2000 4000 8000 dB dB 0 1928 2 2 3 –4 –6 –9 –12 –16 0 7.8 To outlet duct 1928 3857 2 –1 –5 –1 –6 –8 –12 –16 0 5.9 3857 5000 –3 –3 –2 –6 –4 –8 –10 –14 0 4.2 0 1928 4 1 2 –4 –6 –9 –12 –16 –0.2 8.1 To inlet duct 1928 3857 1 –2 –6 0 –4 –9 –11 –16 0.9 4.9 3857 5000 –2 –4 –4 –6 –2 –9 –11 –16 0.4 3.6 0 1928 –6 –5 –3 –9 –11 –15 –20 –31 –5.7 6.9 Through the casing 1928 3857 –6 –8 –9 –7 –12 –15 –23 –35 –6.4 5.6 3857 5000 –12 –13 –8 –12 –8 –15 –21 –33 –5.8 3.1 0 1928 –15 –7 –2 –6 –6 –9 –12 –16 –1.4 3.4 To fan outlet 1928 3857 –19 –11 –10 –3 –6 –8 –12 –16 –0.9 1.7 3857 5000 –26 –14 –7 –8 –4 –8 –10 –14 –0.7 1.1 For information how to calculate sound data, sound pressure level and remote attenuation, see page 9. MOTOR DATA ATEX VERSION Nom Nom Nom Max Motor Total1) Motor Number Max Anti vibration Front Back Motor Code Power Speed current speed weight weight Hub Code IEC of Poles Hz mounting code ØA H5 * ØA H5 * kW r/min A r/min kg kg AXDE-2-00075-c-2-0 80 2 0,75 2877 1,5 4000 69,5 28 39 HULB-1-022-d8-19-1 GTLZ-44-1-022-1-0 30 36 A 30 36 A 1) Appr. total weight in kg for motor and fan (casing + impeller). FläktGroup DC_9993GB_20180629_R0 Specifications are subject to alteration without notice
Description: